• 제목/요약/키워드: Reinforced wall

검색결과 1,074건 처리시간 0.027초

Performance-based reliability assessment of RC shear walls using stochastic FE analysis

  • Nosoudi, Arina;Dabbagh, Hooshang;Yazdani, Azad
    • Structural Engineering and Mechanics
    • /
    • 제80권6호
    • /
    • pp.645-655
    • /
    • 2021
  • Performance-based reliability analysis is a practical approach to investigate the seismic performance and stochastic nonlinear response of structures considering a random process. This is significant due to the uncertainties involved in every aspect of the analysis. Therefore, the present study aims to evaluate the performance-based reliability within a stochastic finite element (FE) framework for reinforced concrete (RC) shear walls that are considered as one of the most essential elements of structures. To accomplish this purpose, deterministic FE analyses are conducted for both squat and slender shear walls to validate numerical models through experimental results. The presented numerical analysis is performed by using the ABAQUS FE program. Afterwards, a random-effects investigation is carried out to consider the influence of different random variables on the lateral load-top displacement behavior of RC members. Using these results and through utilizing the Monte-Carlo simulation method, stochastic nonlinear analyses are also performed to generate random FE models based on input parameters and their probabilistic distributions. In order to evaluate the reliability of RC walls, failure probabilities and corresponding reliability indices are calculated at life safety and collapse prevention levels of performance as suggested by FEMA 356. Moreover, based on reliability indices, capacity reduction factors are determined subjected to shear for all specimens that are designed according to the ACI 318 Building Code. Obtained results show that the lateral load and the compressive strength of concrete have the highest effects on load-displacement responses compared to those of other random variables. It is also found that the probability of shear failure for the squat wall is slightly lower than that for slender walls. This implies that 𝛽 values are higher in a non-ductile mode of failure. Besides, the reliability of both squat and slender shear walls does not change significantly in the case of varying capacity reduction factors.

Plastic hinge length for coupled and hybrid-coupled shear walls

  • Abouzar Jafari;Meysam Beheshti;Amir Ali Shahmansouri;Habib Akbarzadeh Bengar
    • Steel and Composite Structures
    • /
    • 제48권4호
    • /
    • pp.367-383
    • /
    • 2023
  • A coupled wall consists of two or more reinforced concrete (RC) shear walls (SWs) connected by RC coupling beams (CBs) or steel CBs (hybrid-coupled walls). To fill the gap in the literature on the plastic hinge length of coupled walls, including coupled and hybrid-coupled shear walls, a parametric study using experimentally validated numerical models was conducted considering the axial stress ratio (ASR) and coupling ratio (CR) as the study variables. A total of sixty numerical models, including both coupled and hybrid-coupled SWs, have been developed by varying the ASR and CR within the ranges of 0.027-0.25 and 0.2-0.5, respectively. A detailed analysis was conducted in order to estimate the ultimate drift, ultimate capacity, curvature profile, yielding height, and plastic hinge length of the models. Compared to hybrid-coupled SWs, coupled SWs possess a relatively higher capacity and curvature. Moreover, increasing the ASR changes the walls' behavior to a column-like member which decreases the walls' ultimate drift, ductility, curvature, and plastic hinge length. Increasing the CR of the coupled SWs increases the walls' capacity and the risk of abrupt shear failure but decreases the walls' ductility, ultimate drift and plastic hinge length. However, CR has a negligible effect on hybrid-coupled walls' ultimate drift and moment, curvature profile, yielding height and plastic hinge length. Lastly, using the obtained results two equations were derived as a function of CR and ASR for calculating the plastic hinge length of coupled and hybrid-coupled SWs.

광폭인장시험을 통한 지오그리드의 시간의존적 변형 거동 고찰 (Time-dependent Deformation Charateristics of Geogrid Using Wide Width Tensile Test)

  • 유충식;전한용;김선빈
    • 한국지반공학회논문집
    • /
    • 제24권1호
    • /
    • pp.71-80
    • /
    • 2008
  • 본 논문에서는 보강토 구조물에 보강재로 적용되는 지오그리드의 시간 의존적 변형거동 특성에 대한 광폭 인장시험 결과를 제시하였다. 먼저, 다양한 보강재의 종류에 대해 인장속도에 따른 파단강도 및 강성의 변화에 대해 알아보았다. 또한 보강토 구조물이 사용연한 동안 받게될 다양한 하중 조건, 즉 지속하중 및 반복하중을 작용시킬 수 있는 장비를 특수 제작하여 지오그리드의 시간의존적 변형거동을 분석하였다. 그 결과 지속하중 및 반복하중 작용시 잔류변형은 보강재의 점성(viscous) 특성의 형태로서 쌍곡선 특성 곡선으로 잘 모사되는 것으로 분석되었으며 이러한 잔류변형은 시간의존적 점성거동의 측면에서 다루어야 하는 것으로 나타났다.

수치해석을 통한 강합성 빔보강 지하 구조물의 거동분석 (Structural Analysis of CBS (Composite Basement Wall System)-RIB Underground Structures Using Numerical Modeling)

  • 유한규;김연성
    • 한국지반공학회논문집
    • /
    • 제26권6호
    • /
    • pp.39-44
    • /
    • 2010
  • 강합성 구조물의 설계절차는 파형강판구조물에 대한 현행 국내외 시방기준을 따르고 있는데, 시방기준이 2차원 해석 및 설계를 바탕으로 규정되어 있기 때문에 비등가 단면인 강합성 빔보강 공법에는 현행 시방기준을 적용할 수 없다. 그러므로 등가단면의 구조물로 환산하여 2차원 해석 및 설계를 수행하게 된다. 그러나 강합성 빔보강 공법은 종방향을 따라 일정한 간격을 두고 빔과 타입콘크리트를 이용하여 보강을 한 형태이기 때문에 3차원 해석에 기초한 설계과정이 요구된다. 따라서 본 연구에서는 수치해석을 통해 3차원 설계를 위한 해석적인 근거를 제시하고자 한다.

중층형 생활한옥 모델시안 연구 - 청주 서운동의 사례를 중심으로 - (The Tentative Plans of Middle-rise Traditional Houses (Han-ok) Located on Seoun-dong in Urban Area of Cheongju, Korea)

  • 김찬구;김태영
    • 한국농촌건축학회논문집
    • /
    • 제24권2호
    • /
    • pp.21-28
    • /
    • 2022
  • Focusing on the creation of a new han ok, especially a mid-rise hybrid-structured Han-ok, this study proposes a middle-rise (four-story) Han-ok on one and two lots located in Seoun-dong, the existing Han-ok intensive housing site in downtown Cheongju. 1) In terms of layout and function, according to the existing L-shaped Han-ok corresponding to the road and the direction, the parking lots and shops on the 1st floor, the business facility on the 2nd floor, the Han-ok on the 3rd and 4th floors are placed. There are yards, open roof yards, and semi-open Daecheong(大廳, main hall), which can be shared by residents. 2) In terms of structure and form, one or two floors (some 3 floors) are 5.4m square and 5.4×6.6m modules of the RC(Reinforced Concrete) group, and the upper floor reflects the 2.7m module, size and shape of the existing Han-ok. By extending the outer wall of the RC group in the lower floors (1st to 3rd floors) to the wooden exterior of the upper floors (2nd to 4th floors), it is attempted to avoid the awkward appearance of the RC group being exposed to wooden structures. And it is also attempted to reflect the wooden shape and design elements through the elevation elements such as horizontal windows, corner windows, picture frames, and vertical slits. 3) In environmental control and facilities, it is attempted to smooth the ventilation of the building by forming a vertical upward airflow from the dark space of the low floor to the positive of the upper floor. This doubles the effect through a vertical rise of cold air generated in a narrow alleyway, piloti parking lot, and the various voids. In addition to the Daecheong and Numaru(loft) of Han ok, the rooftop yard, the terrace, and the balcony, horizontal natural ventilation is generated through divided doors and transom windows.

실내모형실험을 통한 모래지반에서의 중공블록 보강효과 분석 (Analysis of Reinforcement Effect of Hollow Modular Concrete Block on Sand by Laboratory Model Tests)

  • 이철희;신은철;양태철
    • 한국지반공학회논문집
    • /
    • 제38권7호
    • /
    • pp.49-62
    • /
    • 2022
  • 중공블록 기초공법은 육각형의 벌집구조로 제작된 콘크리트 중공블록을 혼합쇄석과 함께 치환 설치하여 연약지반을 보강하고 인위적인 층상지반을 형성하여 얕은 기초의 지지력 증가와 침하량을 감소시키는 지반보강 기초공법이다. 벌집구조의 중공블록은 기하학적으로 경제적인 구조임과 동시에 힘을 균형 있게 배분하는 안정적인 구조로 기초와 쇄석치환 보강층 사이에서 보강재로써 보강효과를 유발하는 것을 단편적으로 확인하였으나, 거동특성 규명은 아직 미비한 상태이다. 본 연구에서는 실내모형실험을 통해 보강재로써 중공블록의 보강효과를 파악하기 위해 실내 평판재하시험을 수행하였다. 하중-침하 곡선에서 비채움 조건(A-1-N)에서는 관입전단파괴가 발생한 반면에 채움 조건(A-1-F)은 항복이 나타나지 않은 선형 곡선을 나타내며, 원지반 대비 3배의 보강효과를 확인하였다. 중공블록의 구속효과 모식도를 바탕으로 중공블록 콘크리트부의 접지응력과 중공부 구속효과에 의한 수직응력 그리고 수평응력이 작용한 내벽의 내주면마찰력에 대한 관계식을 제안하였다. 관계식 계산결과 중공블록의 콘크리트부의 접지력은 재하하중의 약 65%이고, 중공부 단면에 작용하는 구속 수직력은 약 16.5%이고, 내주면마찰력은 약 18.5%로 분담하는 것으로 나타났다. 본 연구를 통해 중공블록이 보강재로써 상재하중이 작용할 때, 중공블록의 중공부 하단에서는 구속효과로 수직응력이 발생하고, 수평방향이 구속상태인 내부 모래에서 수평응력이 내벽에 작용하여 내주면마찰력이 발생하여 중공블록 콘크리트의 관입을 억제하고 선단 응력이 감소하는 거동특성을 규명하였다.

고성토사면에 시공된 교대의 측방유동에 대한 수치해석적 연구 (Numerical Analysis of Laterally Displacing Abutment in High Landfill Slope)

  • 박민철;장서용;신백철;한희수
    • 한국지반환경공학회 논문집
    • /
    • 제13권2호
    • /
    • pp.27-39
    • /
    • 2012
  • 본 연구에서는 고성토사면 위에 시공된 교대가 강우 침투로 측방유동이 발생되었을 경우 이로 인한 교대의 상대변위를 파악하고 적절한 보강대책 및 설계기준을 제안하고자 한다. 먼저 성토사면의 정확한 수치해석을 위해 현장의 성토재인 화강풍화토를 채취하여 비배수 직접전단시험을 통해 함수비(포화도)변화에 따른 강도정수의 변화를 파악하고 표준관입시험 결과를 토대로 탄성계수와 포아송비 등의 지반정수를 산정하였다. 이후 유한요소법을 이용하여 강우 시 교대 교좌부의 측방유동, 말뚝기초의 부재력을 산정하였다. 산정 결과, 교대 교좌부의 측방변위는 8.98cm로 허용변위량 3.0cm보다 약 3배 정도 크게 산정되었다. 측방유동의 보강대책으로 보강토옹벽, 압성토, 말뚝 기초 자체보강(길이 5m 연장보강, 3열 보강, 3열 5m 연장보강) 등에 대해 검토하였다. 그 결과, 말뚝기초를 보강 (3열 5m 연장보강) 하였을 경우 측방유동으로 인한 교대 교좌부의 상대변위는 2.26cm로 허용변위량보다 적었다.

경량칸막이 벽체를 통한 다중구획공간에서의 화재위험성에 관한 연구 (A Study on Fire Hazards in Multiple Compartments with Lightweight Partition Walls)

  • 박상민;최수길;진세영;김시국
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.14-21
    • /
    • 2020
  • 본 논문은 ISO 9705 2/5축소모델 2개를 실내 공간구획에 사용되는 경량칸막이를 이용하여 구획 한 후 ISO 9705 시험을 재현하여 이면부로의 화재위험성에 관한 연구이다. 실험 시료는 시공 시 가장 많이 사용되고 있는 SGP 칸막이, 스터드 칸막이, 그라스울 패널, 우레탄폼 패널, 샌드위치 패널, 유리 칸막이를 선정 하였고, ISO 9705시험 기준에 따라 버너에 점화 전 측정 장치와 데이터의 기록을 시작하여 120 s간 유지시켜 안정화를 취하고, 점화 후 600 s 동안 100 kW, 이후 600 s 동안 300 kW까지 증가하였다가 종료 후 180 s동안 관찰하여 이면부로의 화재 위험성 및 벽체의 화재 패턴을 분석하였다. 점화원에서 발생된 열량으로 인한 최대 이면온도는 SGP 칸막이 67.7 ℃, 스터드 칸막이 55.1 ℃, 그라스울 패널 52.4 ℃, 샌드위치 패널 727.4 ℃, 우레탄폼 패널 561 ℃, 유리 칸막이 630.5 ℃로 측정되었다. 샌드위치 패널과 우레탄폼 패널의 경우 내장재에 용융으로 인한 가연성 가스의 폭발 현상이 발생하였고 강화유리는 수열부와 비수열부의 온도차이로 인하여 유리가 파열되며 인접구획실로의 화재 위험성이 높은 것으로 판단된다.

A New Root-Strengthening Technique for Acute Aortic Dissection with a Weakened Aortic Root: The Neo-Adventitia Technique

  • Kim, Ji Yong;Kim, In Ha;Heo, Woon;Min, Ho-Ki;Kang, Do Kyun;Hwang, Youn-Ho;Jun, Hee Jae
    • Journal of Chest Surgery
    • /
    • 제50권6호
    • /
    • pp.436-442
    • /
    • 2017
  • Background: Dissection flaps in acute type A aortic dissection typically extend into the root, most frequently into the non-coronary sinus (NCS). The weakened root can be susceptible not only to surgical trauma, but also to future dilatation because of its thinner layers. Herein, we describe a new technique that we named the "neo-adventitia" technique to strengthen the weakened aortic root. Methods: From 2012 to 2016, 27 patients with acute type A aortic dissection underwent supracommissural graft replacement using our neo-adventitia technique. After we applied biologic glue between the dissected layers, we wrapped the entire NCS and the partial left and right coronary sinuses on the outside using a rectangular Dacron tube graft that served as neo-adventitia to reinforce the dissected weakened wall. Then, fixation with subannular stitches stabilized the annulus of the NCS. Results: There were 4 cases of operative mortality, but all survivors were discharged with aortic regurgitation (AR) classified as mild or less. Follow-up echocardiograms were performed in 10 patients. Of these, 9 showed mild or less AR, and 1 had moderate AR without root dilatation. There were no significant differences in the size of the aortic annulus (p=0.57) or root (p=0.10) between before discharge and the last follow-up echocardiograms, and no reoperations on the aortic roots were required during the follow-up period. Conclusion: This technique is easy and efficient for reinforcing and stabilizing weakened roots. Furthermore, this technique may be an alternative for restoring and maintaining the geometry of the aortic root. An externally reinforced NCS could be expected to resist future dilatation.

RC 기둥과 RS 보로 이루어진 보-기둥 접합부의 비탄성 거동 (Inelastic Behavior of Beam-Column Joints Composed of RC Column and RS Beams)

  • 김욱종;윤성환;문정호;이리형
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.734-741
    • /
    • 2002
  • 중앙부 철골조와 단부 RC조로 이루어진 혼합구조보인 RS 보와 RC 기둥으로 이루어진 접합부의 비탄성 거동 및 내진성능을 구명하기 위하여 반복가력에 의한 접합부 실험을 진행하였다. 본 연구는 RC-RS 접합부의 모멘트비를 변수로 하여 두 개의 내부접합부와 한 개의 외부접합부 등 총 3개의 시험체를 제작하여 실험을 진행하였다. 실험결과, 강도와 연성능력은 충분히 발휘하였으나, 접합부의 강성은 부족한 결과를 나타내었다. 이는 RS 보를 구성하는 철골보와 RC 보를 연결하는 강재매입구간에서의 철골 보의 미끄러짐에 의한 변위의 증가로 인하여 강성의 저하가 발생한 것으로 판단된다. 또한 Hawkins의 제안안에 의한RC-RS 접합부의 내진성능을 평가해 본 결과, 접합부의 초기강성의 부족으로 부재각 0.5 %에서의 공칭강도의 발현은 만족하지 못하였으나, 그외의 내진성능 평가지표인 강도유지능력, 상대 에너지소산비 및 종국후 초기강성비나 초기강도비 등의 측면에서는 우수한 능력을 발휘하였다. 따라서 구조물에서 RC-RS 접합부를 적용할 경우, RC 코어 월과 같은 초기 횡 강성을 보완할 수 있는 적절한 구조시스템과 병행하여 적용하면 강진지역의 구조물에도 충분히 적용이 가능하다고 판단된다.