• Title/Summary/Keyword: Rehabilitation Device

Search Result 430, Processing Time 0.027 seconds

A Study on Rehabilitation Treatment Using Radiofrequency Treatment (고주파 통증치료기를 이용한 재활 치료에 대한 연구)

  • Jo, Jae-Hyun;Lee, Sang-Yong;Lee, Geun-Yong;Yoon, Se-Jin;Cheong, Ha-Young;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.212-218
    • /
    • 2020
  • When Radiofrequency energy is applied to the human body, the vibration width is very short. Therefore, the electrolyte burn generated when using the direct current does not occur. Ion molecules, polarized molecules, etc., vibrate more than 40,000 times per second, converting them into frictional heat to generate deep heat. The blood flow of capillaries increases 4-5 times more than at rest, increasing the supply of oxygen, nutrients, antibodies, and white blood cells. In addition, the electrochemical reaction does not occur because the vibration width and the pulsation period are very short. It is a physical factor treatment method that does not stimulate the sensory nerves and motor nerves. In this study, an isotonic exercise is performed in a young normal adult using a Radiofrequency pain treatment device. The purpose of this study is to integrate rehabilitation therapy by measuring electromyography data during isotonic exercise and confirming the effect on changes in motor neuron response. The EMG data generated when isotonic exercise of the forearm biceps muscle and the EMG data measured after the use of a Radiofrequency pain treatment device after exercise were RMS, respectively, and verified through t-test. It was confirmed that there was a significant difference in both men and women because the t-value was smaller than the significance level p (<.05).

The Effects of Occupational Therapy Intervention Using Fully Immersive Virtual Reality Device on Upper Extremity Function of Patients With Chronic Stoke: Case Study (완전 몰입형 가상현실 기기를 이용한 작업치료 중재가 만성 뇌졸중 환자의 상지기능에 미치는 영향: 사례연구)

  • Han, Soul;Yoo, Eun-Young
    • Therapeutic Science for Rehabilitation
    • /
    • v.7 no.2
    • /
    • pp.17-27
    • /
    • 2018
  • Objective : The purpose of this study was to investigate the effect of occupational therapy intervention using a fully immersive virtual reality device on the upper extremity function of patients with chronic stroke. Methods : This study used a single subject (ABA) design. The study subjects was a chronic stroke patient with left lateral deviation. Four baseline periods, 12 intervention periods, and 4 baseline regression periods were performed for a total of 20 sessions for 10 weeks. OT intervention with a fully immersive virtual reality device was used every 30 minutes. BBT and WMFT evaluations were performed at each session and the results were displayed in a line graph. Results : The patient's upper limb function has improved. During baseline recurrence, efficacy of treatment was confirmed after removal of intervention, but no significant changes were observed. Conclusion : It has been found that OT intervention with a fully immersive virtual reality device for upper limb function in chronic stroke patients is an effective intervention. However, the effectiveness of maintaining treatment is not important, so we need to develop an easy-to-use home intervention program.

A study on Evaluation Methods for Safety and Performance of Electrical Stimulations for Home Use (개인용전기자극기 성능 및 안전성 평가 방법 연구)

  • Kim, San;Jang, Moo-Young;Hwang, Yoon Su;Lee, Ki-Hun;Hur, Chan-Hoi;Hong, Choongman
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.187-202
    • /
    • 2013
  • The electronic medical device industry and the relevant market have been greatly expanded owing to various factors, such as the advent of the aged society and the spread of the desire for well-being in developed countries, and rapid development of China, India and other emerging markets. The electrical stimulator is one of electronic medical devices most commonly used in homes. The electrical stimulator is widely used for pain relief, rehabilitation, muscle conditioning and others. Since it is mainly used in homes, it is very important to assure the safety and performance for protection of users. However, there is no guideline on evaluation of safety and performance of such electrical stimulator for home use. In this study, various local and foreign references were reviewed to develop the internationally harmonized procedures for safety and performance evaluation of the electrical stimulator and test items, specifications and methods are proposed. In addition, such proposed test items were validated to decide the internationally harmonized tests for safety and performance evaluation. This study will contribute to improvement of quality and safety of electrical stimulators for home use and help the Korean medical device industry have the international competitiveness.

The Effect of Smooth Pursuit Eye Movement Using Portable Device to Chronic Hemispatial Neglect: A Pilot Study (휴대용 디바이스를 이용한 완곡추적 안구운동이 만성 편측무시에 미치는 영향: 예비연구)

  • Shin, Jae-Yong
    • Therapeutic Science for Rehabilitation
    • /
    • v.6 no.1
    • /
    • pp.71-83
    • /
    • 2017
  • Objective : This study aim is to identify whether smooth pursuit eye movement(SPEM) using portable device can alleviate chronic hemispatial neglect. Methods : We applied smooth pursuit eye movement to one chronic hemispatial neglect patient. Experimental duration was total 4weeks - 1week baseline, 2weeks SPEM intervention, 1week 2nd. baseline. The intervention was 10 SPEM sessions (30min each, 1session daily, from Monday to Friday) over a period of 2weeks. The neglect test carried out 5 times a week. The SPEM was provided on the screen when patient sat in front of the screen(8.4 inch tablet pc, distance 40cm). The SPEM video that the 24 yellow squares moving coherently from the right to the left side. Patients were instructed to perform smooth pursuit eye movement without head and neck movement. Results : As a result of the SPEM for 2weeks, the degree of neglect tended to decrease compared to baseline A. The degree of the LBT tended to increase the at the baseline A'. In contrast, the SCT showed that tendency which the degree of the neglect maintained at the baseline A'. Conclusion : We identified that SPEM using portable device is effective intervention method for chronic hemispatial neglect.

An analysis on satisfaction level of clinicians on implant surgical guidance system based on computed tomography (컴퓨터 단층 촬영을 기반으로 한 임플란트 가이드 시스템에 대한 임상가의 만족도 분석)

  • Hong, Min-ho;Jin, Ming-Xu;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.178-185
    • /
    • 2015
  • Purpose: The purpose of this study was to conduct a comparative assessment on the satisfaction level for the two interfaces of surgical guide system (SimPlant and R2GATE), the design and convenience of manufactured surgical guides and the importance of using the surgical guides thereof by means of survey. Materials and Methods: Hereupon, they simulated the implant surgical process by mounting the two manufactured systems of surgical guide on a dental mold, respectively. The study subjects were instructed to complete the questionnaire as to the satisfaction level upon completion of the simulated surgery. This study summarized the data of each question after collecting the completed questionnaires. Then, this study analyzed the summarized data by utilizing statistical program SPSS 20.0 (IBM). Results: R2GATE had a higher value of the satisfaction level on the design and convenience of manufactures surgical guides. R2GATE group ($7.33{\pm}1.26$) was found to have a higher value in terms of the overall satisfaction level compared to SimPlant group ($6.67{\pm}1.26$) (${\alpha}$ = 0.05). Conclusion: The user satisfaction level on the surgical guide manufactured for R2GATE system was to such an extent as it can be widely used in clinical environment. Moreover, the surgical guide manufactured as R2GATE system can guide both the length and direction of a drill simultaneously. As a result, it is highly recommended for those beginners who do not have a lot of experience in implant placement.

Retrofit Yield Spectra-a practical device in seismic rehabilitation

  • Thermou, G.E.;Elnashai, A.S.;Pantazopoulou, S.J.
    • Earthquakes and Structures
    • /
    • v.3 no.2
    • /
    • pp.141-168
    • /
    • 2012
  • The Retrofit Yield Spectrum (RYS) is a new spectrum-based device that relates seismic demand of a retrofitted structure with the fundamental design parameters of the retrofit. This is obtained from superposition of Yield Point Spectra with design charts that summarize in pertinent spectrum-compatible coordinates the attributes of a number of alternative retrofit scenarios. Therefore, once the requirements for upgrading a given structure have been determined, the RYS enable direct insight of the sensitivity of the seismic response of the upgraded structure to the preliminary design decisions made while establishing the retrofit plan. By virtue of their spectrum-based origin, RYS are derived with reference to a single mode of structural vibration; a primary objective is to control the contribution of this mode in the retrofit design so as to produce a desirable distribution of damage at the ultimate limit state by removing soft storey formations and engaging the maximum number of structural members in deformation, in response to the input motion. Calculations are performed with reference to the yield-point, where secant stiffness is proportional to the flexural strength of reinforced concrete members. Derivation and use of the Retrofit Yield Spectra (RYS) refers to the seismic demand expressed either in terms of spectral acceleration, spectral displacement or interstory drift, at yield of the first storey. A reinforced concrete building that has been tested in full scale to a sequence of simulated earthquake excitations is used in the paper as a demonstration case study to examine the effectiveness of the proposed methodology.

Outcome of Extracorporeal Ventricular Assist Device for Cardiogenic Shock as a Bridge to Transplantation

  • Kim, Hyo-Hyun;Shin, Jung-Hoon;Kim, Jung-Hwan;Youn, Young-Nam
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.368-374
    • /
    • 2020
  • Background: The extracorporeal ventricular assist device (e-VAD) system is designed for left ventricular support using a permanent life support console. This study aimed to determine the impact of temporary e-VAD implantation bridging on posttransplant outcomes. Methods: We reviewed the clinical records of 6 patients with the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile 1, awaiting heart transplantation, who were provided with temporary e-VAD from 2018 to 2019. The circuit comprised a single centrifugal pump without an oxygenator. The e-VAD inflow cannula was inserted into the apex of the left ventricle, and the outflow cannula was positioned in the ascending aorta. The median follow-up duration was 8.4±6.9 months. Results: After e-VAD implantation, lactate dehydrogenase levels significantly decreased, and Sequential Organ Failure Assessment scores significantly improved. Bedside rehabilitation was possible in 5 patients. After a mean e-VAD support duration of 14.5±17.3 days, all patients were successfully bridged to transplantation. After transplantation, 5 patients survived for at least 6 months. Conclusion: e-VAD may reverse end-organ dysfunction and improve outcomes in INTERMACS I heart transplant patients.

Arm Cortex S3C2440 Microcontroller Application for Transcranial Magnetic Stimulation's Pulse Forming on Bax Reactive Cells and Cell Death in Ischemia Induced Rats

  • Tac, Han-Ho;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.266-272
    • /
    • 2016
  • Transcranial magnetic stimulation devices has been used mainly for diagnostic purposes by measuring the functions of the nervous system rather than for treatment purposes, and has a problem of considerable energy fluctuations per repeated pulse. The majority of strokes are caused by ischemia and result in brain tissue damage, leading to problems of the central nervous system including hemiparesis, dysfunction of language and consciousness, and dysfunction of perception. Control is difficult and the size is large due to the difficulty of digitalizing the energy stored in a capacitor, and there are many heavy devices. In addition, there are many constraints when it is used for a range of purposes such as head and neck diagnosis, treatment and rehabilitation of nerve palsy, muscle strengthening, treatment of urinary incontinence etc. Output stabilization and minimization of the energy variation rate are required as the level of the transcranial magnetic stimulation device is dramatically improved and the demand for therapeutic purposes increases. This study developed a compact, low cost transcranial magnetic stimulation device with minimal energy variation of a high repeated pulse and output stabilization using a real time capacitor charge discharge voltage. Ischemia was induced in male SD rats by closing off the common carotid artery for 5 minutes, after which the blood was re-perfused. In the cerebrum, the number of PARP reactive cells after 24 hours significantly decreased (p < 0.05) in the TMS group compared to the GI group. As a result, TMS showed the greatest effect on necrosis-related PARP immuno-reactive cells 24 hours after ischemia, indicating necrosis inhibition, blocking of neural cell death, and protection of neural cells.

Proposal of finger splint design using design guidelines to reflect user requirements - Using FDM 3D printing technology - (사용자의 요구조건을 반영 할 수 있는 디자인 가이드라인을 이용한 손가락 보조기 디자인 제안 - FDM 방식의 3D 프린팅 기술을 이용하여 -)

  • Shin, I Yeol;Oh, Kwang Myung
    • Design Convergence Study
    • /
    • v.18 no.3
    • /
    • pp.1-14
    • /
    • 2019
  • General finger splint manufactured and sold domestically could have been of great help to patients with disabilities due to damage to the body's. However, it reminded the wearer of his disability that he wanted to hide. This has had a negative effect on the psychological side of self-absorption and depression. If this avoids or rejects wearing, the role of ancillary rehabilitation is lost. This does not meet the user's requirements. Thus, in this study, 3D printing was used to better reflect user requirements. Next, the study examined existing prior studies to identify the characteristics and criteria of each study. It also examined medical finger aids that were being sold in the auxiliary device market. The assessment criteria were derived by compiling and interpreting user surveys of each finger splint device. Based on the evaluation criteria derived, the design guidelines for finger splint were presented using FDM-style 3D printers. Finally, we proposed a finger splint design according to the proposed design guideline.

Full mouth rehabilitation of the patient with severely worn dentition using monolithic zirconia prosthesis: A clinical report (치아 마모 환자에서 단일 구조 지르코니아를 이용한 완전 구강 회복 증례)

  • Kim, Tae-Yeon;Han, Jung-Suk;Kim, Sung-Hun;Yeo, In-Sung;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.140-145
    • /
    • 2016
  • Excessive occlusal wear causes loss of tooth structure, occlusal plane disharmony, impaired function and esthetic problems. Although the decrease of occlusal vertical dimension may be compensated by the growth of alveolar bone and tooth eruption, minimal increase of occlusal vertical dimension may be required for esthetics and retention of prosthesis. In this case, a 44-year-old male patient visited Seoul National University Dental Hospital with chief complaint of severe tooth wear and shade disharmony. Based on assessment of diagnostic wax-up, 3 mm increase of occlusal vertical dimension was determined. Removable occlusal splint and interim prosthesis was used to ascertain patient's comfort and adaptation. After the adaptation period, definitive prosthesis fabricated with full-contour monolithic zirconia were delivered and the patient was recommended to wear a nightguard device for prosthesis protection. This report presents a case of full mouth rehabilitation with the elevation of patient's occlusal vertical height, resulting in satisfactory esthetics and functions.