• Title/Summary/Keyword: Region of Interest (ROI)

Search Result 480, Processing Time 0.041 seconds

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact (Metal artifact 감소를 위한 CT simulator 영상 재구성의 유용성 평가)

  • Choi, Ji Hun;Park, Jin Hong;Choi, Byung Don;Won, Hui Su;Chang, Nam Jun;Goo, Jang Hyun;Hong, Joo Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.191-197
    • /
    • 2014
  • Purpose : This study presents the usefulness assessment of metal artifact reduction for orthopedic implants(O-MAR) to decrease metal artifacts from materials with high density when acquired CT images. Materials and Methods : By CT simulator, original CT images were acquired from Gammex and Rando phantom and those phantoms inserted with high density materials were scanned for other CT images with metal artifacts and then O-MAR was applied to those images, respectively. To evaluate CT images using Gammex phantom, 5 regions of interest(ROIs) were placed at 5 organs and 3 ROIs were set up at points affected by artifacts. The averages of standard deviation(SD) and CT numbers were compared with a plan using original image. For assessment of variations in dose of tissue around materials with high density, the volume of a cylindrical shape was designed at 3 places in images acquired from Rando phantom by Eclipse. With 6 MV, 7-fields, $15{\time}15cm2$ and 100 cGy per fraction, treatment planning was created and the mean dose were compared with a plan using original image. Results : In the test with the Gammex phantom, CT numbers had a few difference at established points and especially 3 points affected by artifacts had most of the same figures. In the case of O-MAR image, the more reduction in SD appeared at all of 8 points than non O-MAR image. In the test using the Rando Phantom, the variations in dose of tissue around high density materials had a few difference between original CT image and CT image with O-MAR. Conclusion : The CT images using O-MAR were acquired clearly at the boundary of tissue around high density materials and applying O-MAR was useful for correcting CT numbers.

Quantitative Evaluation of Regional Cerebral Blood Flow by Visual Stimulation in $^{99m}Tc-HMPAO$ Brain SPECT ($^{99m}Tc-HMPAO$ 뇌 SPECT에서 시각자극에 의한 국소 뇌 혈류변화의 정량적 검증)

  • Juh, Ra-Hyeong;Suh, Tae-Suk;Kwark, Chul-Eun;Choe, Bo-Young;Lee, Hyoung-Koo;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.166-176
    • /
    • 2002
  • Purpose: The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of $^{99m}Tc-HMPAO$ (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. Materials and Methods: The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and $^{99m}Tc-HMPAO$ SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the legion of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map (SPM99). Results: The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was $32.50{\pm}5.67%$. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Conclusion: Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann.

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

Evaluation of Glioma with Thallium-201 Brain SPECT: The Correlation with $^1H$ MR Spectroscopy and Pathology ($^{201}Tl$ 뇌 SPECT을 이용한 신경교종의 평가)

  • Sohn, Hyung-Sun;Kim, Euy-Neyng;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Yong-An;Chung, Soo-Kyo;Hong, Yong-Gil;Lee, Youn-Soo;Choe, Bo-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.465-477
    • /
    • 2000
  • Purpose: Thallim-201 ($^{201}Tl$) brain SPECT and proton ($^1H$) magnetic resonance spectroscopy (MRS) have been used to evaluate tumor grade and viability of glioma. We assessed the correlations between $^{201}Tl$ brain index or spectrum of metabolites of $^1H$ MRS and grade of glioma or histopathologic findings. Materials and Methods: We studied 17 patients (4 astrocytoma, 7 anaplastic astrocytoma and 6 glioblastoma). On $^{201}Tl$ Brain SPECT, $^{201}Tl$ index was measured as the ratio of average counts for region of interest to those for the contralateral normal brain. On $^1H$ MRS, we calculated choline (Cho) /creatine (Cr) ratio and N-acetylaspartate (NAA)/Cr ratio in ROI defined as tumor center. Histopathologic findings were graded by Ki-67 index, cellularity, mitosis, pleomorphism, necrosis and endothelial proliferation. An unpaired t test and statistical correlations were performed to evaluate these data. Results: Tl-index showed the best correlation with Ki-67 index (p<0.01), less correlations with cellularity, mitosis, and endothelial proliferation, but no correlation with results of MRS, pleomorphism, or necrosis. The findings of MRS did not correlate with all of the above. The cases of glioblastoma demonstrated a higher Tl-index, Cho/cr ratio, Ki-67 index and lower NAA/Cr ratio, albeit without statistical significance. Conclusion: Even though $^{201}Tl$ brain SPECT did not correlate directly with grade of malignancy, it may still be useful in determining biological aggressiveness of tumor and prognosis of patients because it correlated well with Ki-67 index, a growth fraction of glioma, cellularity, mitosis and endothelial proliferation.

  • PDF

Development of the Multi-Parametric Mapping Software Based on Functional Maps to Determine the Clinical Target Volumes (임상표적체적 결정을 위한 기능 영상 기반 생물학적 인자 맵핑 소프트웨어 개발)

  • Park, Ji-Yeon;Jung, Won-Gyun;Lee, Jeong-Woo;Lee, Kyoung-Nam;Ahn, Kook-Jin;Hong, Se-Mie;Juh, Ra-Hyeong;Choe, Bo-Young;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.153-164
    • /
    • 2010
  • To determine the clinical target volumes considering vascularity and cellularity of tumors, the software was developed for mapping of the analyzed biological clinical target volumes on anatomical images using regional cerebral blood volume (rCBV) maps and apparent diffusion coefficient (ADC) maps. The program provides the functions for integrated registrations using mutual information, affine transform and non-rigid registration. The registration accuracy is evaluated by the calculation of the overlapped ratio of segmented bone regions and average distance difference of contours between reference and registered images. The performance of the developed software was tested using multimodal images of a patient who has the residual tumor of high grade gliomas. Registration accuracy of about 74% and average 2.3 mm distance difference were calculated by the evaluation method of bone segmentation and contour extraction. The registration accuracy can be improved as higher as 4% by the manual adjustment functions. Advanced MR images are analyzed using color maps for rCBV maps and quantitative calculation based on region of interest (ROI) for ADC maps. Then, multi-parameters on the same voxels are plotted on plane and constitute the multi-functional parametric maps of which x and y axis representing rCBV and ADC values. According to the distributions of functional parameters, tumor regions showing the higher vascularity and cellularity are categorized according to the criteria corresponding malignant gliomas. Determined volumes reflecting pathological and physiological characteristics of tumors are marked on anatomical images. By applying the multi-functional images, errors arising from using one type of image would be reduced and local regions representing higher probability as tumor cells would be determined for radiation treatment plan. Biological tumor characteristics can be expressed using image registration and multi-functional parametric maps in the developed software. The software can be considered to delineate clinical target volumes using advanced MR images with anatomical images.

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.

A Study on the Reduction of Kidney Uptake of 18F-FDG due to the Water Intake at the Time of Additional Examination in the PET/CT scan (PET/CT 검사에서 추가 검사 시 수분섭취에 따른 18F-FDG의 신장 섭취 감소에 대한 고찰)

  • Lee, Yi Lang;Kim, Sang Gyu;Ham, Jun Chul;Nam-Koong, Hyuk;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.47-51
    • /
    • 2016
  • Purpose By ingestion of 18F-FDG of kidney of PET/CT during the inspection, if additional examination is required, depending on whether you want to water intake, we want to confirm a change in the rate of decrease of F-18 FDG of the kidney. Materials and Methods The 80 patients without kidney disease were performed PET/CT examination. Device was analyzed after setting the kidney to a three-dimensional region of interest. In patients require additional examination, and inspection after 30 minutes, a PET/CT torso examination after the water of the 500 cc ingested at a time. After the addition of both water intake group and no hydration group of kidney of SUV, it was compared with PET/CT torso scan. Results High and low of the kidney SUV did not show a significant difference in the rate of decrease. Reduction rates of background (BKG) of additional examination was 2.8% and reduction rates of SUV was 49.7% (Hydration) : -6.8% (No hydration), so did show a significant difference. In the image blind test, the average point score of hydration and no hydration was 34.25 : 17.25. Conclusion An undercurrent of 18F-FDG in the kidney at the time of torso examination, it was confirmed that the reduction rate after the addition of water intake is high. It is considered that can be expected to improve the quality of an image due to a decrease in elongation through the kidneys examination with additional fluid intake as needed intake.

  • PDF

Relationship Between Insertion Torque, and Pullout Strength Depending on the Size of the Pilot Hole and Biodegradable Suture Anchor in Osteoporotic Humeral Head (골다공증이 있는 상완골 골두의 파일럿 홀 (Pilot Hole)과 흡수성 나사못의 크기에 따른 토크 (Torque)와 뽑힘 강도 (Pullout Strength) 간의 관계)

  • Chun, Yong-Min;Lee, Young-Han;Kim, Sung-Hwan;Park, Yoo-Jung;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.8-15
    • /
    • 2012
  • Purpose: The object of this study was to investigate the difference in torque and pullout strength between the standard anchor insertion (5.0 mm) with a small awl (3.7 mm) and larger anchor insertion (6.5 mm), with a standard awl (5.0 mm) in osteoporotic humeral head. Materials and Methods: The embalmed 24 paired cadaveric shoulders were assigned to either Group A or B. After measuring the bone mineral density (BMD) of the ROI (region of interest) in the humeral head, 5.0 mm suture anchors were inserted using a 3.7 mm awl in Group A1, and the same 5.0 mm anchors were inserted using a 5.0 mm awl in Group A2. The 5.0 mm anchors were inserted using a 5.0 mm awl in Group B1, and 6.5 mm anchors were inserted using a 5.0 mm awl in Group B2. We measured the torques at the time of the anchor insertion and pullout strengths. Results: There was no significant difference in the BMD between the groups. The torque of A1 (20.6 $cN{\cdot}m$) was significantly higher than that of A2 (13.2 $cN{\cdot}m$), and the torque of B2 (20.8 $cN{\cdot}m$) was significantly higher than that of B1(12.1 $cN{\cdot}m$). However, the difference in the increased torque between group A and B was not significant. The pullout strength of A1 (204.2 N) was significantly higher than that of A2 (152.9 N), and the pullout strength of B2 (210.9 N) was significantly higher than that of B1 (149.5 N). However, the difference in the increased pullout strength between Group A and B was not significant. Conclusion: In severe osteoporosis, the use of a larger suture anchor with a standard awl increased the torque and pullout strength significantly, in comparison to the use of the same sized suture anchor and awl. If there is an inadequate interval between the anchors on the greater tuberosity, the use of a 3.7 mm awl and 5.0 mm anchor will be beneficial compared to that of a 5.0 mm awl and 6.5 mm anchor, considering that an increase in the pullout strength does not depend on the awl size.

Consideration on the Satisfaction of Patients and SUV Variation According to Whether or not to Listen to Music after 18F-FDG Injection (PET/CT 검사에서 18F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰)

  • Park, Suyoung;Yun, Sunhee;Kim, Hwasan;Kim, Hyunki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of $^{18}F-FDG$ (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned $^{18}F-FDG$ PET/CT and also received care through the tracking test (mean age $55.61{\pm}12.41$ years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value=0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A. It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using $^{18}F-FDG$, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.