• Title/Summary/Keyword: Regenerative system

Search Result 484, Processing Time 0.022 seconds

Regenerative Current Control Method of Bidirectional DC/DC Converter for EV/HEV Application

  • Lee, Jung-Hyo;Jung, Doo-Yong;Lee, Taek-Kie;Kim, Young-Ryul;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.97-105
    • /
    • 2013
  • The control method of the bidirectional DC/DC converter for instantaneous regenerative current control is described in this paper. The general method to control the DC/DC converter is the output voltage control. However, the regenerative current cannot be controlled to be constant with this control method. To improve the performance of the conventional control method, the DC-link voltage of the inverter is controlled within the tolerance range by the instantaneous boost and buck operations of the bidirectional DC/DC converter. By the proposed control method, the battery current can be controlled to be constant regardless of the motor speed variation. The improved performance of the DC/DC converter controlled by the proposed control method is verified by the experiment and simulation of the system with the inverter and IPMSM(Interior Permanent Magnet Synchronous Motor) which is operated by the reduced practical speed profile.

Analysis of Noise Characteristic of Uneven Pitch Regenerative Blower (부등피치를 적용한 재생 블로워의 소음특성 연구)

  • Lee, Kyoung-Yong;Jung, Uk-Hee;Kim, Jin-Hyuk;Kim, Cheol-Ho;Choi, Young-Seok;Ma, Jae-Hyun;Jeong, Kyung-Ho;Park, Woon-Jean
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.71-75
    • /
    • 2015
  • The flow and noise characteristics of the regenerative blower are evaluated experimentally. To decrease the noise of regenerative blower at a high frequency, we arrange the impeller vanes unevenly by special formula. The uneven pitch formular consists of the combination of trigonometric function. The magnitude of degree between each vanes and the control parameters of trigonometric functions are main design parameters for the uneven pitch. The flow characteristics of even and uneven impellers are tested by the fan tester and compared each results. The efficiency of a blower is calculated by the axial power using a dynamo system. The noise property of designed impeller is measured in an anechoic room. In this study, we certify that the uneven pitch impeller is effective in the noise reduction at a high frequency.

A Study on the Development of the Large Building Air-conditioning System with the Regenerative Ice-energy and its Computer Aided Design (빙축열을 이용한 대형빌딩 공기조화시스템 개발과 설계전산화에 관한 연구)

  • 권형정;김원영;김용모;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.5
    • /
    • pp.38-46
    • /
    • 1991
  • In the design of an electric power plant, the capacity to meet the peak load demand is one of the important factors to be considered. This peak load usually occurs when the most of the cooling air-conditioning systems are being operated during daytime in summer season. Therefore, it is necessary to construct an additional electric power plant and to develop the new air-conditioning system for relieving the peak load. This paper analysed the performance characteristics of this experimental regenerative ice energy system by means of a bundle of the heat-pipes. And the result of this analysis was applied to the simulation of an air-conditioning system model. Also, an operation program of moisture air was made according to air load and in order to computerize the air-conditioning system a CAD program was developed by the properties of moisture air.

  • PDF

Model Based Fault Detection for Advanced ESC System (지능형 ESC 시스템을 위한 모델 기반 결함검출)

  • Kim, Byeong-Woo;Hur, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2306-2313
    • /
    • 2010
  • This paper describes a model based fault detection algorithm for an Advanced ESC System which consists of Hydraulic Control Unit (HCU) with built-in wheel pressure sensors. Advanced ESC System can be used for various value-added functions such as Stop & Go Function and Regenerative Brake Function. Therefore, HCU must have a reliable fault detection. Due to the huge amount of sensor signals, existing specific sensor based fault detection of HCU cannot guarantee the safety of vehicle. However, proposed algorithm dose not require the sensors. When model based fault detection algorithm detects severe failures of the HCU, it warns the driver in advance to prevent accidents due to the failures. For this purpose, a mathematical model is developed and validated in comparison to actual data. Simulation results and data acquired from an actual system are compared with each other to obtain the information needed for the fault detection process.

The review of the safety for the development of insulated hanger in overhead contact line (전차선로 절연 행거 개발에 대한 안전성 검토)

  • Lee, Jae-Bong;Park, Weon-Chan
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1431-1440
    • /
    • 2009
  • A subway in Seoul has had a major role of public transportation after the opening of Seoul Subway Line 1 on August 15, 1974 and it has reached 34.7% of the transportation of Seoul citizens. The extended length of the subway system suppled with DC power in Korea is about 500km. In this system, the devices which are proper for regenerative power system are being required because of changeover from old braking and ATS signal system to regenerative braking and ATO signal system. In this paper, we reviewed the safety standards for the insulated hangers in overhead contact line. These hangers which have depended on foreign imports are being developed in Korea considering ease of demand and supply and economic effects.

  • PDF

Development of Regenerative Inverter for Electric Railway Using Space Vector PWM (SVPWM을 이용한 전기철도용 회생 인버터 개발)

  • Jung M.G.;Baek B.S.;Kim T.W.;Ryu S.P.;Kim N.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.15-18
    • /
    • 2003
  • The electric power, regenerated while railway vehicles braking or running downhill, makes U line voltage rise and the feeding system may not be secure. In order to keep away from these kind of insecurity, the regenerative energy should be consumed by loads or transmitted to the AC side via certain devices such as DC/AC converters. This paper introduces the developed regenerative inverter for electric railway.

  • PDF

Thermal flow analysis in heat regenerator with spheres (구형축열체를 이용한 축열기내 열유동 해석)

  • 조한창;조길원;이용국
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.359-364
    • /
    • 2003
  • Heat regenerator occupied by regenerative materials improves thermal efficiency of regenerative combustion system through the recovery of sensible heat of exhaust gases. By using one-dimensional two-phase fluid dynamics model, the unsteady thermal flow of regenerator with spherical particles, were numerically analyzed to evaluate the heat transfer and pressure losses and to suggest the parameter for designing heat regenerator. It is confirmed that the computational results, such as air preheat temperature, exhausted gases outlet temperature, and pressure losses, agreed well with the experimental data conducted from Chugairo. The thermal flow in heat regenerator varies with porosity, configuration of regenerator and diameter of regenerative particle. Assuming a given exhaust gases temperature at the regenerator outlet, the regenerator length need to be linearly increased with inlet Reynolds number of exhaust gases. It is considered that inlet Reynolds number of exhaust gases should be introduced as a regenerator design parameter.

  • PDF

The Regenerative Drive of Induction Servo Motor by the Flux Acceleration Method (자계벡터 가속법에 의한 유도형 서보전동기의 전력회생 구동)

  • Hong, Soon-Ill;Hong, Jeng-Pyo;Jung, Seoung-Hwan
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2006.06a
    • /
    • pp.77-80
    • /
    • 2006
  • This paper based on spiral vector, three phase induction motor is described a detailed modeling by a phase segment methode. Based on this model, A torque control and the equation of regenerative power for the induction motor drive, based on the field acceleration method(FAM), is presented. The speed control system is designed to be applied voltage source inverters that is easy the current type feedback of power regeneration for motor drive. The ability of shaving power to be measured power regeneration has been investigated in speed acceleration and reduction. And it is change of stator resistance that the voltage commands include error, the ripple of exited voltage and torque occur from the results. The experimental tests verify the performance of the proposed regenerative drive for FAM, proving that good behavior of the drive is achieved in the transient and steady-state operating conditions.

  • PDF

Numerical Analysis of Fluid Flow in a Regenerative Cooling Passage (재생냉각 유로 내의 유동에 관한 수치해석)

  • 조원국
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.1
    • /
    • pp.46-52
    • /
    • 2000
  • A computational analysis has been made on fluid flow in a regenerative cooling Passage for a reduced size liquid rocket engine to predict pressure drop and heat transfer rate in it. The contraction/expansion of the cross sectional area of the passage turn out to increases both the pressure loss and the heat transfer rate of the duct. The changes of the cross sectional area near the nozzle throat are effective to protect the throat which suffers from severe thermal load. Also given is the qualitative characteristics of the performance of the regenerative cooling system due to the variation of coolant flow rate.

  • PDF

IPMSM Torque Control Method available CC-CV Charge Control (CC-CV충전제어가 가능한 IPMSM 토크제어기법)

  • Kim, Jun-Chan;Won, Il-Kuen;Choo, Kyung-Min;Hong, Sung-Woo;Kim, Woo-jae;Kim, Do-Yun;Kim, Young-Real;Won, Chung-yuen
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.407-408
    • /
    • 2017
  • In regenerative mode of an IPMSM control system without a bi-directional DC-DC converter, the 3-phase PWM inverter charges the battery. At this time, the regenerative torque reference for braking must output the proper torque reference to charge the battery. This paper proposed a regeneration control method that controls the voltage and current of the battery through CC-CV control at the regenerative braking torque corresponding to the driver's brake control.

  • PDF