• 제목/요약/키워드: Regenerative power control

검색결과 100건 처리시간 0.025초

전기철도 차량 내 변압기의 여자돌입전류 저감에 관한 연구 (A Study on the Reduction of Onboard Transformer Inrush Current of Electric Railway)

  • 허재선;강병욱;신희상;김재철
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2125-2130
    • /
    • 2010
  • The neutral section on electric railway system is significant sector in order to prevent short circuit of two electric powers. However, while electric trains pass the neutral section, those speed is decreased and the accident of AC electric traction system and the electric train would be occurred. So the countermeasures are urgently needed. The automatic power switching technology system that is current being research and development is system to improve these problems. Because main object of this system is power change using static switch in the neutral section, it's expected to cause a variety of transients. Especially, onboard transformer inrush current for electric railway train can be occurred more than rated current according to switching time. Therefore, the analysis and improvement are needed to ensure the stability of this system. In this paper, we analyze the operating characteristics of the automatic power switching technology system. Especially, it reviews inrush current according to the closing phase angle. And we propose control plan of inrush current considering the case that voltage is maintained due to counter electromotive force and regenerative braking operation of electric railway train. Finally, the proposed control scheme was reviewed using the transient analysis program.

수직순환식 입체주차설비용 인버터 제어시스템 (A Inverter Control System for Vertical Circulation Parking Facility)

  • 최철;이진하;김철우
    • 전력전자학회논문지
    • /
    • 제9권3호
    • /
    • pp.294-302
    • /
    • 2004
  • 본 연구에서는 수직순환식 입체주차설비용 유도전동기를 제어할 수 있는 인버터장치를 개발하였다 차량의 주차 공간인 파렛트를 호출하는 경우 종래 시스템에 있어서의 승강장 정위치 제어 불능 문제와 이동속도가 잔존한 상태에서의 강제 제동에 따른 제동장치계통의 급속한 마모현상을 근본적으로 해결하도록 하였다. 또한 전원회생기능을 구비한 컨버터제어기를 적용함으로써 수전단 전원용량의 축소와 동작빈도수의 증가에 따른 소비전력의 절감 효과를 기하도록 하였다. 본 연구를 통해 수직순환식 기계식 주차설비의 구동제어에 있어서 부하에 따른 위치 및 속도제어를 효과적으로 구현함으로써 정숙한 운전 특성을 확보하였고 역률제어에 따른 에너지 절감 효과를 기하였다. 실험은 55㎾급 유도전동기를 대상으로 하여 그 결과를 확인하였다.

SRG의 안정발전제동을 위한 기준전류 제한방식에 관한 연구 (Reference Current Limit Control for Stable Generative Breaking of SRG)

  • 김태형;박성준;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.69-71
    • /
    • 2003
  • Switched reluctance machine has much attention because of high efficiency, high power and DC series torque characteristics with a traction drive. But the motor has to have a regenerative mode when it is adopted in an electric vehicle. A current divergence during the regeneration makes difficulties in the control of SRM. This paper proposes a reference current limitation strategy for a stable regeneration based on simulations and experimental tests. The motor is operated with conventional current limit and switching angle control method in motoring mode. Simulations and experiments are executed to verify proposed method.

  • PDF

SRM의 최대 도통비를 갖는 여자전압 제어기법 (Excitation Voltage Control with a maximum Conduction Ratio of SRM)

  • 이상훈;박성준;안진우;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.977-979
    • /
    • 2001
  • The application of SRM(Switched Reluctance Motor) is dramatically increasing due to a simple mechanical structure, high efficiency and a good high speed characteristics. Generally, turn-off angle of power switch must be limited the demagnetization period. To control high conduction ratio in motor operation and regenerative voltage in the generator operation in the SRM, multi-level voltage control is effective. This paper proposes multi-level inverter to have a maximum conduction ratio of SRM. The proposed method is verified by experiment.

  • PDF

부하 특성에 따른 교류 급전시스템에서의 보호방식 연구 (A Study on Protection system to the Load Characteristics on the AC Feeder System)

  • 정호성;한문섭;이장무;김주락
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1370-1372
    • /
    • 2004
  • At present. distance relay and ${\Delta}I$ current increment relay are used as primary and secondary protection in the AC feeder system. However. electric railway vehicles according to power electronic's development had developed resistance control, thyristor phase control and PWM control system. and operation of train is increasing in a feeder section. Therefore this paper analyzes the load characteristics and situation of relay's maloperation caused by load current increase, harmonics, regenerative braking current and operation of the different vehicles in same feeder section. Based on this analysis. this paper proposes consideration items for relay correction and advanced adaptive relay that can change operation area according to load current.

  • PDF

Thyristor전력변환기-전동기계의 무효전력의 처리에 관한 연구

  • 유철로
    • 전기의세계
    • /
    • 제31권1호
    • /
    • pp.50-58
    • /
    • 1982
  • As a method for improving the power factor and the waveform of ac line current drawn by ac to dc converters, converters of pulse-width control type with forced commutation circuits have been developed in recent years. However, these converters have rather complex commutation circuits which contain auxiliary thyristors in addition to the main thyristors, and their performance is not satisfactory. This paper proposes a new pulse-width controlled ac to dc converter, and analyses its commutation mechanism and its input and output characteristics. The proposed converter circuit consists of a usual thyristor bridge circuit with series diodes to which reactors and diodes are added. This circuit dose not contain auxiliary thyristors, and in this sense it is simpler than the previous converter circuits of pulse-width control type. Since the main thyristors of the converter can be forcedly turned off several times in a half cycle of source voltage, a pulse-width modulation control is possible in order to improve the current waveform as well as the power factor on ac line side. As to dc output side it is shown that the adjustable range of output voltage is wide and the voltage regulation is good due to a rapid reversal of voltage across the commutating capacitors by LC resonance during commutation period. It is also shown that the regenerative operation of the converter is possible.

  • PDF

DC/DC 전력 컨버터의 전류모드 PWM 제어기의 방사선 영향 (Effects of the Irradiated Current Mode PWM Controller of DC/DC Power Converter)

  • 노영환;황의성;노경수;푸파논;캄푸는;한창운
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.685-692
    • /
    • 2011
  • DC/DC switching power converters produce DC output voltages from different DC input sources. The converters can be used in regenerative braking of DC motors to return energy back in the supply, resulting in energy savings for the systems containing frequent stops. The current mode DC/DC converter is composed of a PWM (pulse width modulation) controller, a MOSFET, and inductor, etc. Pulse width modulation is applied to control and regulate the total output voltage. It is shown that the variation of threshold voltage at MOSFET and the offset voltage increase caused by radiation effects make the PWM pulse unstable. In the PWM operation, the missing pulses, the changes in pulse width, and a change in the period of the output waveform are studied by simulation program with integrated circuit emphasis (SPICE) and experiments.

  • PDF

전동차 주행성능평가를 위한 데이터취득 및 분석 (Data Acquisition and Analysis for Running Performance Evaluation of the Electric Train)

  • 이강원;김명룡;백광선;심재복;창상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1099-1100
    • /
    • 2006
  • The running of the electric train are done by powering, breaking and coasting. Powering to start and accelerate the rolling stock means driving the three-phase electric induction motors controlled by VVVF inverters which are connected to overhead power line directly(DC) or indirectly(AC, DC/AC). Breaking is achieved by blending control which is the proportional combination between regenerative breaking of VVVF inverter and air pressure control of breaking operating unit(BOU). Therefore, Data obtained during two operation are very important items to evaluate the running performance of RS. This paper has investigated in real time data acquired from VVVF inverter and measured by pressure sensor directly connected to air breaking line(motor car and trailer car). By analyzing data in the region of time and frequency, fundamental methods for eavaluating the running performance of RS quantitatively and objectively have been suggested.

  • PDF

철도차량용 IGBT Gate Driver Unit 기술 동향 분석 연구 (Research on Technical Trends of IGBT Gate Driver Unit for Railway Car)

  • 조인호;이재범;정신명;이병희
    • 한국철도학회논문집
    • /
    • 제20권3호
    • /
    • pp.339-348
    • /
    • 2017
  • 철도차량용 전원창치는 추진제어용 전원장치와 보조전원장치로 구분된다. 추진제어용 전원장치는 철도차량의 추진 및 회생제동 등의 동작을 위한 것이며, 보조전원장치는 추진제어용 전원을 제외한 공기압축기, 조명기기, 차량제어전원 등의 보조전원에 사용되는 것이다. 각 전원장치는 고전압, 고전류 사양 특성에 따라 일반적으로 insulated-gate bipolar transistor (IGBT)를 스위칭 소자로 사용하고 있다. 스위칭 소자를 사용하기 위해서는 적절한 스위칭 동작을 구현하기 위한 구동회로(Gate Driver Unit, GDU)가 필수적이다. 본 논문에서는 철도차량에 적용되고 있는 IGBT용 GDU에 적용되고 있는 기술 동향을 분석하고 철도차량용 IGBT GDU 설계 시 고려사항에 대해 알아보고자 한다.

MCV의 기능밸브를 고려한 굴삭기의 실시간 시뮬레이션 (Real-Time Simulation of an Excavator Considering the Functional Valves of the MCV)

  • 임용현;이상욱;조민기;신대영;황성호
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권4호
    • /
    • pp.38-47
    • /
    • 2019
  • In this paper, a real-time simulation model of an excavator using Amesim was proposed, considered the operation of functional valves with the main control valve (MCV). The hydraulic system models including the pump and MCV have been developed. The kinematic and dynamic models of the manipulator have also been developed, to confirm the behavior of the excavator. The MCV model includes various functional valves such as the regenerative valves, holding valves, swing and boom priority valves, and regen-cut valves so that simulations similar to real excavators can be performed. Additionally, to obtain the real-time calculation performance, the parts with no major influence on the dynamic behavior were simplified, high frequency factors were removed, and parameters were optimized. The models were compared with each other through the numerical analysis with variable time-step and fixed time-step, and the results were verified by comparison with the results of the actual vehicle tests.