• Title/Summary/Keyword: Reference table

Search Result 302, Processing Time 0.023 seconds

The design and implementation of automatic translation system for hangul's romanization (국어 로마자 표기 자동 변환 시스템 설계 및 구현)

  • 김홍섭
    • KSCI Review
    • /
    • v.2 no.1
    • /
    • pp.45-54
    • /
    • 1995
  • This study is, by assigning ASCII codes hardly used to Bandaljum(ˇ) and making the fonts of Korean-English character mode, to design the way of converting automatically a word, a sentence or a document of korean into phonetic letters by applying the algorismized phonological principles inputted as a letter string, even though a user do not konw the basic principles of the usage of Korean-to-Romanization notation rule. This is designed so that it may be possible to turn into a mechanical code with reference to the corresponding character in the table of Korean-to-Romanization notation rule that is the currently used standard proposition of the government. Consequently this program makes it user more convenient in the manipulations of special case words, the assistance of colorful-screen or pull-down, pop-up menu and the adoptation of utilizable mouse works for a user convienency. This program could be installed in a single diskette of 5.25"(2HD) and be made in C programming language to mplement various font, expansion or condense of font, alternative printing.ting.

  • PDF

A Study on the Improvement of the Records Management Reference Table in the MND USFK Base Relocation Office (주한미군기지 이전사업단의 기록관리기준표 개선방안)

  • Kim, Yong-Chan
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.19 no.1
    • /
    • pp.95-115
    • /
    • 2019
  • The relocation project of the US military base in South Korea is a large-scale national project aimed at ensuring a stable presence of US troops stationed in South Korea and strengthening the future-oriented Korea-US Alliance by relocating the US military base scattered across the country to Pyeongtaek. The purpose of this study is to examine the classification of records produced by various agencies involved in the relocation project, including the MND USFK Base Relocation Office that is the main body of the project, and provide basic data for systematic records management in the future. This study aims to ensure the people's right to know and achieve the objective of the transmission of the military documentary heritage at a macro level.

Image Sensor Module for Detecting Spatial Color Temperature in Indoor Environment (실내 환경의 공간 색온도 검출을 위한 이미지센서 모듈)

  • Moon, Seong-Jae;Kim, Young-Woo;Lim, Yeong-Seog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.191-196
    • /
    • 2021
  • In this paper, we implemented an image sensor module possible of detecting color temperature in an indoor environment. The color temperature information in the video information acquired by the image sensor was matched with a color difference illuminometer to produce an LUT. An algorithm was developed so that color temperature information according to the received RGB values can be automatically calculated. As a result of measuring the color temperature with an image sensor indoors, an accurate result of less than 5.91% was obtained compared to the reference value. It was confirmed that the uniformity of 23.5% or more was excellent compared to the color temperature measurement result using a color sensor.

Efficiency Evaluation of CT Simulator QA Phantom (전산화 단층촬영 모의치료기 정도관리 팬텀의 유용성 평가)

  • Hwang, Se-Ha;Min, Je-Sun;Lee, Jae-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Purpose: The purpose is to evaluate efficiency of the CT simulator QA phantom manufactured for daily QA. Materials and Methods: We made holes ($1{\times}100{\times}1\;mm$) to verify accuracy between image and real measurement in polystyrene phantom and made 1 mm holes to verify table movement accuracy at superior and inferior 100 mm to the center of the phantom and inserted radiopacity material. To evaluate laser alignment, we made cross mark on the right and left side at phantom and to evaluate CT number accuracy we made 3 cylindrical holes and inserted equivalence material of bone, water, air in them. After CT scanning the phantom, We evaluated accuracy between image and real measurement, accuracy of table movement, laser, and CT number using exposed image. Results: It was measured that the accuracy between image and real measurement was ${\pm}0.3\;mm$, table movement accuracy was ${\pm}0.3\;mm$, laser accuracy was ${\pm}0.5\;mm$ from 7th January to 7th March in 2008 as within the reference point ${\pm}1\;mm$. In the CT number accuracy of bone was ${\pm}10\;HU$, air was ${\pm}5\;HU$, water was ${\pm}5\;HU$ as within the reference point is ${\pm}10\;HU$. Conclusion: We was able to perform CT simulator QA and laser equipment QA more conveniently and fast using manufactured phantom at the same time. We will be able to make more accurate treatment plan that added to QA procedures using images at previous daily QA.

  • PDF

Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System (전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가)

  • Yu, Minsun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.455-464
    • /
    • 2012
  • This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.

A Study on the Design of Case-based Reasoning Office Knowledge Recommender System for Office Professionals (사례기반추론을 이용한 사무지식 추천시스템)

  • Kim, Myong-Ok;Na, Jung-Ah
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.3
    • /
    • pp.131-146
    • /
    • 2011
  • It is becoming more essential than ever for office professionals to become competent in information collection/gathering and problem solving in today's global business society. In particular, office professionals do not only assist simple chores but are also forced to make decisions as quickly and efficiently as possible in problematic situations that can end in either profit or loss to their company. Since office professionals rely heavily on their tacit knowledge to solve problems that arise in everyday business situations, it is truly helpful and efficient to refer to similar business cases from the past and share or reuse such previous business knowledge for better performance results. Case-based reasoning(CBR) is a problem-solving method which utilizes previous similar cases to solve problems. Through CBR, the closest case to the current business situation can be searched and retrieved from the case or knowledge base and can be referred to for a new solution. This reduces the time and resources needed and increase success probability. The main purpose of this study is to design a system called COKRS(Case-based reasoning Office Knowledge Recommender System) and develop a prototype for it. COKRS manages cases and their meta data, accepts key words from the user and searches the casebase for the most similar past case to the input keyword, and communicates with users to collect information about the quality of the case provided and continuously apply the information to update values on the similarity table. Core concepts like system architecture, definition of a case, meta database, similarity table have been introduced, and also an algorithm to retrieve all similar cases from past work history has also been proposed. In this research, a case is best defined as a work experience in office administration. However, defining a case in office administration was not an easy task in reality. We surveyed 10 office professionals in order to get an idea of how to define a case in office administration and found out that in most cases any type of office work is to be recorded digitally and/or non-digitally. Therefore, we have defined a record or document case as for COKRS. Similarity table was composed of items of the result of job analysis for office professionals conducted in a previous research. Values between items of the similarity table were initially set to those from researchers' experiences and literature review. The results of this study could also be utilized in other areas of business for knowledge sharing wherever it is necessary and beneficial to share and learn from past experiences. We expect this research to be a reference for researchers and developers who are in this area or interested in office knowledge recommendation system based on CBR. Focus group interview(FGI) was conducted with ten administrative assistants carefully selected from various areas of business. They were given a chance to try out COKRS in an actual work setting and make some suggestions for future improvement. FGI has identified the user-interface for saving and searching cases for keywords as the most positive aspect of COKRS, and has identified the most urgently needed improvement as transforming tacit knowledge and knowhow into recorded documents more efficiently. Also, the focus group has mentioned that it is essential to secure enough support, encouragement, and reward from the company and promote positive attitude and atmosphere for knowledge sharing for everybody's benefit in the company.

An Alternative Method for a Rapid Urease Test Using Back-table Gastric Mucosal Biopsies from Gastrectomy Specimen for Making the Diagnosis of Helicobacter pylori Infection in Patients with Gastric Cancer (위암 환자의 헬리코박터 파이로리 감염 진단에 있어서 위절제술 직후 생검된 위점막 조직을 이용한 신속 요소 분해 효소 검사법 도입의 의의)

  • Kim, Sin-Ill;Jin, Sung-Ho;Lee, Jae-Hwan;Min, Jae-Seok;Bang, Ho-Yoon;Lee, Jong-Inn
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.172-176
    • /
    • 2009
  • Purpose: The rapid urease test is a rapid and reliable method for diagnosing Helicobacter pylori infection. However it requires gastric mucosal biopsies during endoscopy, and the test is not covered by national health insurance for patients with gastric cancer. So, we introduced an alternative method for a rapid urease test using back-table gastric mucosal biopsies from gastrectomy specimen. Materials and Methods: Ninety gastric cancer patients underwent an anti H. pylori IgG ELISA test and gastrectomy. Just after gastrectomy, two gastric mucosal biopsies from the prepyloric antrum and lower body of the gastrectomy specimen were taken from the back table in the operative room, and these were fixed immediately with the rapid urease test kit, and the color change was monitored for up to 24 hours. In this study, H. pylori infection was defined as positive when the serology or rapid urease test showed positive results. Results: The positive rate of the rapid urease test and serology was 91.1% and 77.8%, respectively. The sensitivity, specificity, positive predictive value and negative predictive value of the rapid urease test and serology were 94.3 and 80.5%, 100 and 100%, 100 and 100%, and 37.5 and 15%, respectively. The accuracy of the rapid urease test was higher than that of serology (94.4 vs. 81.1%, respectively). The rapid urease test showed a higher rate of detecting H. pylori infection than that of serology (McNemar's test, P=0.019). Conclusion: The result of the rapid urease test using back-table gastric mucosal biopsies from a gastrectomy specimen is comparable to the reference data of the conventional rapid urease test using gastric mucosal endoscopic biopsies. Therefore, it can be an alternative diagnostic method for H. pylori infection.

  • PDF

An Active Prefetch Filtering Schemes using Exclusive Prefetch Cache (선인출 전용 캐시를 이용한 적극적 선인출 필터링 기법)

  • Chon Young-Suk;Kim Suk-il;Jeon Joong-nam
    • The KIPS Transactions:PartA
    • /
    • v.12A no.1 s.91
    • /
    • pp.41-52
    • /
    • 2005
  • Memory reference instruction caused by cache miss is the critical factor that limits the processing power of processor. Cache prefetching technique is an effective way to reduce the latency due to memory access. However, excessively aggressive prefetch leads to cache pollution and finally to cancel out the advantage of prefetch. In this study, an active prefetch filtering scheme is introduced which dynamically decides whether to commence prefetching after referring a filtering table to reduce the cache pollution due to unnecessary prefetches. For the precision filtering, an evicted address referencing scheme has been proposed where the filter directly compares the current prefetch address with previous unnecessary prefetch addresses stored in filtering table. Moreover, a small sized exclusive prefetch cache has been introduced to increase the amount of eviction of unnecessarily prefetched addresses to enhance the accuracy of dynamic filtering. The exclusive prefetch cache also prevents useful demand data from being pushed out by prefetched data, while the evicted address direct referencing scheme enables the prefetch cache to keep most of useful prefetch data within its small size. Experimental results from commonly used general and multimedia benchmarks show that the average cache miss ratio has been decreased by $13.3{\%}$ by virtue of enhanced filtering accuracy compared with conventional schemes.

A Scheduling Algorithm using The Priority of Broker for Improving The Performance of Semantic Web-based Visual Media Retrieval Framework (분산시각 미디어 검색 프레임워크의 성능향상을 위한 브로커 서버 우선순위를 이용한 라운드 로빈 스케줄링 기법)

  • Shim, Jun-Yong;Won, Jae-Hoon;Kim, Se-Chang;Kim, Jung-Sun
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.1
    • /
    • pp.22-32
    • /
    • 2008
  • To overcome the weakness of the image retrieval system using the existing Ontology and the distributed image based on the database having a simple structure, HERMES was suggested to ensure the self-control of various image suppliers and support the image retrieval based on semantic, the mentioned framework could not solve the problems which are not considered the deterioration in the capacity and scalability when many users connect to broker server simultaneously. In this paper the tables are written which in the case numerous users connect at the same time to the supply analogous level of services without the deterioration in the capacity installs Broker servers and then measures the performance time of each inner Broker Component through Monitoring System and saved and decides the ranking in saved data. As many Query performances are dispersed into several Servers User inputted from the users Interface with reference to Broker Ranking Table, Load Balancing system improving reliability in capacity is proposed. Through the experiment, the scheduling technique has proved that this schedule is faster than existing techniques.

Human Engineering Approach to the Standardization of Shelving, Chairs, Tables and Card Cabinets for College and University Libraries In Korea (한국 대학도서관 가구의 표준화에 관한 인간공학적 연구 -서가${\cdot}$의자${\cdot}$책상${\cdot}$ 목록함을 중심으로-)

  • Sohn Jung Pyo
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.11
    • /
    • pp.3-42
    • /
    • 1984
  • This is to establish a model of the standardization of shelving, chairs, tables and card cabinets for college and university libraries in Korea. The size of furniture was measured on the base of the analysis of the human factors, such as the standard size of human bodies of the college students in Korea, the scope of work area, the moving degree of muscles, the limit of the visual field, etc. The results of this study are as follows: 1. It is desirable that the standard shelf length should be 800mm. and the maximum . shelving height should not exceed 1,803mm. And it is desirable that the bottom shelf has a ground clearance of about $210\~390mm$. 2. It is advisable that the sloped shelving has the slope from about 1,000mm, or 930mm, and the gradient should be $19^{\circ}$ from the above mentioned sloping position and the bottom of each shelf. And it is desirable that the slope height of each shelf should be 77mm. 3. It is advisable that the seat area for users should be $410\~420\times420mm$, and the seat height should be $390\~0400mm$. 4. It is desirable that the table size per user should exceed $490\times880\~890mm$, and the table height should be $680\~690mm$. 5. It is advisable that each tray of the card cabinet should hold about 740 cards, and the depth should exceed 430mm. And it is desirable that the maximum height of card cabinets should be as follows: 60du(drawer units)-$1,400\~1,460mm$, 30du-1, 300mm, 15du-1,100mm. In addition, it is advisable that the 30du cabinet should accomodate 5 trays vertically and 6 trays horizontally for avoiding the worst working position rather than 6 trays vertically and 5 trays horizontally. 6. It is desirable that the height of sliding reference shelves in card cabinets, or consultation tables should be 900mm. But in the case of the sliding shelves, it is desirable to be as follows: 15du-900mm when the card cabinet height is more than 1,100, mm, but unnecessary when less than 1,100mm high, 30du-1,000mm, or 1,100mm in the case of $5\times6du$, but 900mm in the case of $6\times5du$, $60du-900\~950mm$ when the card cabinet height is $1,400\~1,460mm$.

  • PDF