• 제목/요약/키워드: Reference phase

검색결과 1,370건 처리시간 0.025초

Experimental Study of Two-step Phase-shifting Digital Holography based on the Calculated Intensity of a Reference Wave

  • Li, Jun;Pan, Yang Yang;Li, Jiao sheng;Li, Rong;Zheng, Tao
    • Journal of the Optical Society of Korea
    • /
    • 제18권3호
    • /
    • pp.230-235
    • /
    • 2014
  • Two-step quadrature phase-shifting digital holography based on the calculated intensity of a reference wave is proposed. In the Mach-Zehnder interferometer (MZI) architecture, the method only records two quadrature-phase holograms, without reference-wave intensity or object-wave intensity measurement, to perform object recoding and reconstruction. When the reference-wave intensity is calculated from the 2D correlation coefficient (CC) method that we presented, the clear reconstruction image can be obtained by some specific algorithm. Its feasibility and validity were verified by a series of experiments with 2D objects and 3D objects. The presented method will be widely used in real-time or dynamic digital holography applications.

소프트웨어 PLL 기반 소형 고속 BLDCM의 속도 제어 (Speed Control of High Speed Miniature BLDCM Based on Software PLL)

  • 이동희
    • 전력전자학회논문지
    • /
    • 제14권2호
    • /
    • pp.112-119
    • /
    • 2009
  • 본 논문은 홀센서를 사용하는 고속 소형 BLDCM의 속도제어를 위해 PLL 방식을 적용하였다. 제안된 방식은 기준펄스 신호와 홀센서 신호와의 위상차를 이용하는 PLL 기반의 속도제어 기법으로, 별도의 속도 계산이 요구되지 않고, 지령전류는 직접 두 신호의 위상차에 의해 결정된다. 전류 지령은 두 펄스 신호의 위상차에 따라서, 전동기의 속도를 일정하게 유지하기 위하여 변화된다. 제안된 방식은 매우 간단하지만 효과적인 속도 제어를 구현할 수 있다. 또한, 부드러운 토크를 발생하기 위하여 지령 전류는 가속 및 감속 패턴을 따라 변동하도록 설계되었다. 제안된 방식은 50W, 40,000[rpm]급의 소형 고속 BLDCM에 적용하여 실험하였다.

단상 부스트 PFC 컨버터용 가상 DQ 동기좌표계 기반 고성능 전류제어 알고리즘 (High Performance Current Control Algorithm Based on Virtual DQ Synchronous Reference Frame for Single-Phase Boost PFC Converter)

  • 김현근;진성민;이상희;이수형;김준석
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.496-503
    • /
    • 2017
  • This study proposes a high-performance current control algorithm for a diode-bridge-type single-phase boost power factor correction (PFC) converter. The conventional asynchronous single-phase current controllers that directly control AC-type current tend to be accompanied by steady-state errors due to their poor dynamic characteristics for the transient-state, which can be attributed to bandwidth limitations and phase delays. In the proposed algorithm, an ideal current control with minimal phase delays and steady-state errors can be achieved by using a virtual DQ synchronous reference frame and by controlling the synchronous reference frame excluding the frequency component in the single-phase system. The performance of the conventional asynchronous single-phase current controller is compared with that of the proposed algorithm through simulation and experiments, and the results have confirmed the superiority of the latter.

Ionospheric Storm Detection Method Using Multiple GNSS Reference Stations

  • Ahn, Jongsun;Lee, Sangwoo;Heo, Moonbeom;Son, Eunseong;Lee, Young Jae
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제8권3호
    • /
    • pp.129-138
    • /
    • 2019
  • In this work, we propose detection method for ionosphere storm that occurs locally using widespread GNSS reference stations. For ionosphere storm detection, we compare ionosphere condition with other reference stations and estimate direction of movement based on ionosphere time variation. The method use carrier phase measurement of dual frequency, for accuracy and precision of test statistics, are evaluated with multiple GNSS reference stations data.

직렬형 단상 하이브리드 능동 전력필터의 새로운 제어법 (A New Control Method of Series Single-Phase Hybrid Active Power Filter)

  • 김진선;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.149-151
    • /
    • 2005
  • This paper deals with the novel control algorithm of single-phase hybrid active power filter for the compensation of harmonic current components in nonlinear R-L load with passive active power filters. To construct two-axes coordinate, an imaginary second phase was made by giving time delay to line current. In this proposed method, the new signal, which was the delayed through the filtering by the phase-delay property of low-pass filter, is used as the secondary phase. Because two phases have different phase, instantaneous calculation of harmonic current is possible. In this paper, a reference voltage is created by multiplying gain of filter by compensation current using the rotating reference frames that synchronizes with source-frequency, not applying to instantaneous reactive power theory which has been used with the existing fixed reference frames. This paper shows the experimental results, which provide a high accuracy and extremely fast response of single-phase hybrid active Bower filter under the operation with the proposed control method.

  • PDF

6상 영구자석 동기전동기의 고장대응운전을 위한 3상 구동시스템 전환 알고리즘 (Three Phase Drive Transfer Algorithm for Fault Tolerance Control of Six-Phase PMSM)

  • 김성훈;장원진;조관열;김학원
    • 전력전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.256-262
    • /
    • 2021
  • Six-phase motors can be used in industrial applications, such as an electric vehicle, due to their high reliability and low current magnitude per phase. An asymmetrical PMSM with two sets of three-phase windings is a commonly used structure for six-phase motors, with each winding set demonstrating a phase difference of 30°. Although the asymmetrical PMSM presents low torque ripples, its dynamic torque response deteriorates due to coupled components in the two three-phase windings. The decoupled VSD control is applied to eliminate the coupling effect. Load ratio control of two inverters for the six-phase PMSM is proposed in this study. DQ currents are controlled on the basis of two synchronous reference frames, and the six-phase drive system can be changed to a three-phase drive system when one inverter presents fault conditions. The operation and effectiveness of the proposed algorithm is verified through simulation and experiments. The six-phase drive system is transferred to a three-phase drive system by changing the current reference of the second DQ reference frame. Moreover, control of both torque and speed exhibits satisfactory performance before and after the mode change.

노이즈 영상으로부터 모아레 기준 위상의 강인 자동 생성 방법 (A Robust Method for Automatic Generation of Moire Reference Phase from Noisy Image)

  • 고국원;김민영
    • 한국산학기술학회논문지
    • /
    • 제10권5호
    • /
    • pp.909-916
    • /
    • 2009
  • 본 연구는 위상천이 영사식 모아레 측정기의 기준 위상 측정단계에서 기준 위상의 검출 정확도를 높이기 위한 방안으로, 일반적인 N-bucket 방법이 아닌, 줄무늬 패턴 투사 영상의 직접적인 영상처리를 기반으로, 노이즈가 포함된 영상으로부터 기준 위상을 자동으로 검출하고 보정하는 방법을 다룬다. 일반적으로 기준위상을 정확히 구하기 위해서는 상대적으로 노이즈가 원천적으로 적은 고정밀도의 교정 시편과 이에 맞는 세분화된 교정방법이 필요하다. 하지만, 고가의 시편 제작비용 절감과 고정도 교정을 위한 교정시간의 단축을 위해, 상대적으로 일반 정밀도등급의 제작된 시편으로부터 획득된 영상을 이용하여, 효율적인 기준위상 교정 방법을 제안한다. 투사된 평행 라인 띠가 시편에서 반사되어 카메라로 입력되는 영상으로부터, 영상처리 라인마스크를 이용하여 격자 라인들의 중심점을 정밀하게 추출하고, 각 라인들에서 추출된 샘플링점 기반의 최소자승법을 이용하여, 라인 특징치인 기울기와 절편을 추출함으로써 실제 관측되는 격자 라인의 중심선을 획득하였으며, 획득된 중심선들을 이용하여 N-bucket 알고리즘에 적용할 수 있도록 위상을 추출한 후, 기준위상을 자동으로 생성하였다. 본 연구를 통하여 고가의 시편 제작 없이 빠르게 자동으로 기준위상을 추출할 수 있었다.

단상 계통연계형 인버터의 SRF-PLL 옵셋 오차로 인한 전류 맥동 저감에 관한 연구 (A Study on Current Ripple Reduction Due to Offset Error in SRF-PLL for Single-phase Grid-connected Inverters)

  • 황선환;황영기;권순걸
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.68-76
    • /
    • 2014
  • This paper presents an offset error compensation algorithm for the accurate phase angle of the grid voltage in single-phase grid-connected inverters. The offset error generated from the grid voltage measurement process cause the fundamental harmonic component with grid frequency in the synchronous reference frame phase lock loop (PLL). As a result, the grid angle is distorted and the power quality in power systems is degraded. In addition, the dq-axis currents in the synchronous reference frame and phase current have the dc component, first and second order ripples compared with the grid frequency under the distorted grid angle. In this paper, the effects of the offset and scaling errors are analyzed based on the synchronous reference frame PLL. Particularly, the offset error can be estimated from the integrator output of the synchronous reference frame PLL and compensated by using proportional-integral controller. Moreover, the RMS (Root Mean Square) function is proposed to detect the offset error component. The effectiveness of the proposed algorithm is verified through simulation and experiment results.

New Reference Generation for a Single-Phase Active Power Filter to Improve Steady State Performance

  • Lee, Ji-Heon;Jeong, Jong-Kyou;Han, Byung-Moon;Bae, Byung-Yeol
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.412-418
    • /
    • 2010
  • This paper proposes a new algorithm to generate a reference signal for an active power filter using a sliding-window FFT operation to improve the steady-state performance of the active power filter. In the proposed algorithm the sliding-window FFT operation is applied to the load current to generate the reference value for the compensating current. The magnitude and phase-angle for each order of harmonics are respectively averaged for 14 periods. Furthermore, the phase-angle delay for each order of harmonics passing through the controller is corrected in advance to improve the compensation performance. The steady-state and transient performance of the proposed algorithm was verified through computer simulations and experimental work with a hardware prototype. A single-phase active power filter with the proposed algorithm can offer a reduction in THD from 75% to 4% when it is applied to a non-linear load composed of a diode bridge and a RC circuit. The active power filter with the proposed reference generation method shows accurate harmonic compensation performance compared with previously developed methods, in which the THD of source current is higher than 5%.

평지 및 계단 환경에서 보행 속도 변화에 대응 가능한 웨어러블 로봇의 보행 위상 추정 방법 (Gait Phase Estimation Method Adaptable to Changes in Gait Speed on Level Ground and Stairs)

  • 김호빈;이종복;김선우;기인호;김상도;박신석;김강건;이종원
    • 로봇학회논문지
    • /
    • 제18권2호
    • /
    • pp.182-188
    • /
    • 2023
  • Due to the acceleration of an aging society, the need for lower limb exoskeletons to assist gait is increasing. And for use in daily life, it is essential to have technology that can accurately estimate gait phase even in the walking environment and walking speed of the wearer that changes frequently. In this paper, we implement an LSTM-based gait phase estimation learning model by collecting gait data according to changes in gait speed in outdoor level ground and stair environments. In addition, the results of the gait phase estimation error for each walking environment were compared after learning for both max hip extension (MHE) and max hip flexion (MHF), which are ground truth criteria in gait phase divided in previous studies. As a result, the average error rate of all walking environments using MHF reference data and MHE reference data was 2.97% and 4.36%, respectively, and the result of using MHF reference data was 1.39% lower than the result of using MHE reference data.