• Title/Summary/Keyword: Reference method

Search Result 6,861, Processing Time 0.032 seconds

Quantifying Uncertainty of Vitamin C Determination in Infant Formula by Indophenol Titration Method (인도페놀 적정법에 의한 성장기용조제식 중 비타민 C 함량분석의 측정불확도 산정)

  • Jun, Jang-Young;Kwak, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.352-359
    • /
    • 2005
  • Uncertainty involved during determination of vitamin C content in infant formula was quantified by indophenol titration method. Uncertainty sources in measurand, such as purity, weight, final volume of standard, volume of standard solution used for titration, sample weight, final volume of sample, extraction solution used for titration, titration of extraction solution and standard solution by indophenol solution were identified and used as parameters for combined standard uncertainty based on Guide to the expression of uncertainty in measurement (GUM) and Draft EURACHEM/CITAC Guide. Uncertainty parameters of each source in measurand were identified as resolution, reproducibility and stability of chemical balance, standard material purity, repeatability, reproducibility, end point of titration, 1 mL pipet, 5 mL autopipet, and 100 mL mass flask. Each uncertainty component was evaluated by types A and B and included to calculate combined uncertainty. Analytical test result for traceability under laboratorial conditions using Certified Reference Material (CRM) test was certified as $108.4{\pm}1.7mg/100g$, which was within CRM certification range of $114.6{\pm}6.6mg/100g$. Uncertainty test result of vitamin C content of 5 g sampling was $56.7{\pm}2.44mg/100g$. Uncertainty could be reduced by identification of uncertainty sources and components related with vitamin C determination by indophenol titration method and by decreasing uncertainty sources and components.

Suitability of Measuring a Kidney Depth with Assessment of Glomerular Filtration Rateusing 99mTc-DTPA in the Ectopic Kidney and Pediatric Patients (99mTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성)

  • Choi, Jae Min;Lee, Young Hee;Shim, Dong Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • A glomerular filtration rate (GFR) study is a test that uses radioactive materials or tracers (radiopharmaceuticals) and a computer to see how well the kidneys are working. Asan Medical Center analyzed and compared data between kidney depth, acquired from kidney donors' CT image and acquired from Gates method's GFR value that are calculated by Tonnesen equation. This study was able to confirm that kidney depth measured from CT image was higher than the Gates Method's GFR value, which was calculated by Tonnessen equation; the direct relationship among pathologic results is confirmed. Particularly, kidney donor whose kidney was at the pelvic area had direct relationship with other clinical results. During the GFR test, it is necessary to confirm the location of kidney has no change with reference of CT image. If kidney depth is manually corrected using CT image when we measures GFR of deformed or horse-shoe kidney, it would be possible to acquire the compatible value which is equivalent to clinical result. There would be a possible issue of appropriateness that whether the applied GFR using CT image's kidney depth has clinical validity. In case of a pediatric patient, the GFR derived from Tonnesen was quiet underestimated while manual method and Gordon stay in normal range. Which results may be correct among them? There have been many reports about kidney depth, to be an accurate index of GFR in children. As one of the study performers, we should contemplate what the best option for pediatric patients would be.

  • PDF

External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities (고체팬텀을 이용한 국내 방사선 치료시설의 흡수선량에 대한 조사)

  • Choi, Chang-Heon;Kim, Jung-In;Park, Jong-Min;Park, Yang-Kyun;Cho, Kun-Woo;Cho, Woon-Kap;Lim, Chun-Il;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.50-56
    • /
    • 2010
  • Purpose: We report the results of an external audit on the absorbed dose of radiotherapy beams independently performed by third parties. For this effort, we developed a method to measure the absorbed dose to water in an easy and convenient setup of solid water phantom. Materials and Methods: In 2008, 12 radiotherapy centers voluntarily participated in the external auditing program and 47 beams of X-ray and electron were independently calibrated by the third party’s American Association of Physicists in Medicine (AAPM) task group (TG)-51 protocol. Even though the AAPM TG-51 protocol recommended the use of water, water as a phantom has a few disadvantages, especially in a busy clinic. Instead, we used solid water phantom due to its reproducibility and convenience in terms of setup and transport. Dose conversion factors between solid water and water were determined for photon and electron beams of various energies by using a scaling method and experimental measurements. Results: Most of the beams (74%) were within ${\pm}2%$ of the deviation from the third party's protocol. However, two of 20 X-ray beams and three of 27 electron beams were out of the tolerance (${\pm}3%$), including two beams with a >10% deviation. X-ray beams of higher than 6 MV had no conversion factors, while a 6 MV absorbed dose to a solid water phantom was 0.4% less than the dose to water. The electron dose conversion factors between the solid water phantom and water were determined: The higher the electron energy, the less is the conversion factor. The total uncertainty of the TG-51 protocol measurement using a solid water phantom was determined to be ${\pm}1.5%$. Conclusion: The developed method was successfully applied for the external auditing program, which could be evolved into a credential program of multi-institutional clinical trials. This dosimetry saved time for measuring doses as well as decreased the uncertainty of measurement possibly resulting from the reference setup in water.

Comparison between Stimulus and Response AC/A Ratios for Each Phoria with Additional Spherical Power (사위별 가입렌즈에 따른 자극 AC/A비와 반응 AC/A비의 비교)

  • Lee, Se-Hee;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.345-351
    • /
    • 2014
  • Purpose: The accommodative response and the near horizontal phoria were examined with additional spherical power to analyze the stimulus and response AC/A ratios that suggest reference data for the binocular vision. Methods: The open-field autorefractometer (Nvision-K 5001, Shin nippon) and modified thorington method (MIM card; Muscle Imbalance Measure card, Bernell) at 40 cm were utilized to measure the accommodative response and the near horizontal phoria for 81 persons ($20.89{\pm}1.92$ years old) with additional spherical power. The stimulus and the response AC/A ratios were calculated by gradient AC/A method. Results: The exophoria group showed the highest accommodative response ($1.92{\pm}0.26D$) at 40 cm, followed by orthophoria group and esophoria group($1.72{\pm}0.26D$ and $1.62{\pm}0.42D$, respectively) Meanwhile, the esophoria group showed the biggest ocular deviation for the near ($23.24{\Delta}$) followed by the orthophoria group and exophoria group ($19.76{\Delta}$ and $15.14{\Delta}$, respectively). The biggest difference of the stimulus and the response AC/A ratios was $1.72{\Delta}$ for the exophoria group with -2.00 D, while the one was $3.43{\Delta}$ for the esophoria group with +1.00 D. There was a significant difference between AC/A ratios for the exophoria group with -2.00 D, -1.00 D and the esophoria group with +3.00 D, +2.00D, +1.00D and -1.00D. Conclusions: The difference between stimulus and response AC/A was greater when increased minus spherical power for the exophoria group, while it was greater when increased plus spherical power for the esophoria group. Furthermore, the difference for the esophoria group was a greater than the one for the exophoria group.

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF

Analysis of Urban Heat Island Intensity Among Administrative Districts Using GIS and MODIS Imagery (GIS 및 MODIS 영상을 활용한 행정구역별 도시열섬강도 분석)

  • SEO, Kyeong-Ho;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.2
    • /
    • pp.1-16
    • /
    • 2017
  • This study was conducted to analyze the urban heat island(UHI) intensity of South Korea by using Moderate Resolution Imaging Spectroradiometer(MODIS) satellite imagery. For this purpose, the metropolitan area was spatially divided according to land cover classification into urban and non-urban land. From the analysis of land surface temperature(LST) in South Korea in the summer of 2009 which was calculated from MODIS satellite imagery it was determined that the highest temperature recorded nationwide was $36.0^{\circ}C$, lowest $16.2^{\circ}C$, and that the mean was $24.3^{\circ}C$, with a standard deviation of $2.4^{\circ}C$. In order to analyze UHI by cities and counties, UHI intensity was defined as the difference in average temperature between urban and non-urban land, and was calculated through RST1 and RST2. The RST1 calculation showed scattered distribution in areas of high UHI intensity, whereas the RST2 calculation showed that areas of high UHI intensity were concentrated around major cities. In order to find an effective method for analyzing UHI by cities and counties, analysis was conducted of the correlation between the urbanization ratio, number of tropical heat nights, and number of heat-wave days. Although UHI intensity derived through RST1 showed barely any correlation, that derived through RST2 showed significant correlation. The RST2 method is deemed as a more suitable analytical method for measuring the UHI of urban land in cities and counties across the country. In cities and counties with an urbanization ratio of < 20%, the rate of increase for UHI intensity in proportion to increases in urbanization ratio, was very high; whereas this rate gradually declined when the urbanization ratio was > 20%. With an increase of $1^{\circ}C$ in RST2 UHI intensity, the number of tropical heat nights and heat wave days was predicted to increase by approximately five and 0.5, respectively. These results can be used for reference when predicting the effects of increased urbanization on UHI intensity.

The Current Status of Multidrug-resistant Tuberculosis in Korea (국내 다제내성 결핵의 실태)

  • Kim, Byoung-Ju;Lee, In-Hee;Lee, Duk-Hyung;Bai, Gill-Han;Kong, Suk-Jun;Lee, Sun-Hwa;Moon, Hae-Ran;Lee, Kyoung-Ryul;Lee, Jun-Young;Park, Seung-Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.4
    • /
    • pp.404-411
    • /
    • 2006
  • Purpose : Multidrug-resistant tuberculosis (MDR-TB) is an emerging threat to human beings. However, there is little data on the current status of MDR-TB in Korea. This study investigated the current status of MDR-TB in Korea using a survey of all the data from drug susceptibility tests (DST) performed across the country over the last three years. Method : The DST results between Jan. 2000 and Dec. 2002 from 7 laboratories, which were in charge of all antituberculous DSTs across the country as of March 2002, were collected and analyzed to determine the actual number of drug-resistant or MDR-TB patients, annual trend, degree and pattern of resistance against anti-TB drugs, etc. Results : Six laboratories used the absolute concentration method for DST and one used the proportional method. 59, 940 tests had been performed over the 3 year study period. The number of DST performed annually was 18,071, 19,950, and 21,919 in 2000-2002, respectively. The number of resistant tuberculosis patients (resistant against at least one anti-TB drug) had increased by 16.9% from 6,338 in 2000 to 7,409 in 2002. The rate of resistant tuberculosis among all DST results was 35.1% in 2000, 34.5% in 2001, and 33.8% in 2002. The number of MDR-TB patients (resistant against at least both isoniazid and rifampin) showed an increasing trend (14.5%) from 3,708 in 2000 to 4,245 in 2002. Conclusion : Approximately 4,000 MDR-TB cases are newly identified by DST annually and the number is showing an increasing trend. This study suggests that in order to cope with the current MDR-TB situation, the DST methods will need to be standardized and more aggressive measures will be required.

Normative data of penile length in Korean newborns (한국인 신생아 음경 길이에 대한 연구)

  • Kim, Sang Yeob;Jun, Jae Sung;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.944-949
    • /
    • 2008
  • Purpose : As modern society has became more open, interest in healthy internal and external growth has increased, including that pertaining to penile length in children. A micropenis is defined as one where penile length is more than 2 SD (standard deviation) below the mean, and it can be traced back to chromosome and endocrine disorders. The authors executed this study to suggest guidelines for the study of the micropenis and standard information for penile length in Korean newborns. Methods : The subjects of this study were 168 male infants between 37 and 42 weeks of gestational age, none of whom had any complications during pregnancy or birth; each had been born in Daegu Fatima Hospital between February and June 2007. Penile length was measured using conventional stretched penile length measurement (CPLM) and syringe methods. Results : Penile length was $3.02{\pm}0.25cm$ (F=36.467, $R^2=0.180$, P<0.001) when measured with CPLM, and $3.29{\pm}0.26cm$ (F=9.149, $R^2=0.052$, P<0.001) with the syringe method. There was no statistically significant difference in the penile length of newborn infants as a result of taking measurements with the two methods, and both methods showed significance at 0.631 in terms of Pearson's correlation coefficient, at the level of P=0.01. Conclusion : In this study, penile length tended to be longer when gestational age was longer, and a micropenis can be assumed to be one less than 2.5 cm using CPLM and less than 2.8 cm using the syringe method. In the case of a concealed penis, the syringe method is helpful. When a micropenis is assumed, close observation by outpatient department personnel, and additional endocrine and chromosome studies should be undertaken after sufficiently consulting the parents.

Improvement of GPS positioning accuracy by static post-processing method (정적 후처리방식에 의한 GPS의 측위정도 개선)

  • 김민선;신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.251-261
    • /
    • 2003
  • To measure the GPS position accuracy and its distribution according to the length of the baseline, 30 minutes to 24 hours observations at the fixed location were conducted with two GPS receivers (Ll, 12 channels) on May 29 to June 2, 2002. The GPS data received at the reference station, the rover station and the ordinary times GPS observation station operated by the National Geography Institute in Korea were processed in kinematic and static post-processing methods with a post -processing software. The results obtained are summarized as follows: 1. The number of the satellite that could be observed continuously more than six hours was 16 and most of these satellites were positioned at east-west direction on May 31, 2002. The number of the satellite observed and the geometric dilution of precision (GDOP) determined by the average of every 10 minute for the day were 8 and 3.89, respectively. 2. Both the average GPS positions before and after post-processing were shifted (standalone: 1.17 m, post -processing: 0.43m) to the south and west. The twice distance root mean square (2drms) measured with standalone was 6.65m. The 2drms could be reduced to 33.8% (standard deviation 0=17.2) and 5.3% (0=2.2) of standalone by the kinematic and the static post-processing methods, respectively. 3. The relationship between the length of the baseline x (km) and the 2drms y (m) obtained by the static post-processing method was y=0.00l6x+0.006 $(R^2=0.87)$. In the case of the positioning with the static post-processing method using the GPS receiver, it was found that a positioning within 20cm 2drms was possible when the length of the baseline was less than 100km and the receiving time of the GPS is more than 30 minutes.

Comparision of Preparation Methods for Water Soluble Vitamin Analysis in Foods by Reversed-Phase High Performance Liquid Chromatography (역상 고속 액체 크로마토그래피에 의한 식품 중 수용성 비타민 분석을 위한 전처리법의 비교)

  • Kim, Hyung-Soo;Jang, Duck-Kyu;Woo, Dong-Kyun;Woo, Kang-Lyung
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.141-150
    • /
    • 2002
  • Owing to a need for simple extraction and purification for analysis of water soluble vitamins in food samples by RP-HPLC with UV-detector, the methods of bromelain and protease hydrolysis and $C_{18}$ Sep-Pak solid phase extraction were employed. The recoveries of standard water soluble vitamins by the bromelain and protease hydrolysis and $C_{18}$ Sep-Pak solid phase extraction were significantly high compared to AOAC methods in most of vitamins. The contents of pyridoxal determined with protest in the pork was similar, but in the bromelain hydrolysis and AOAC method, was high compared to the results of reference. The niacinamide, thiamin and riboflavin determined with bromelain and protease hydrolysis showed similar values to the results of references. In the potato, pyridoxamine was detected in the AOAC method, which was not detected in the bromelain and protease hydrolysis methods. Pyridoxal contents in the protease hydrolysis and AOAC methods were very similar to the results of references. The recoveries of fortified standard vitamins in food samples were significantly high and accurate compared to those of AOAC methods. The extraction and purification with $C_{18}$ Sep-Pak solid extractor might be considered superior method for the determination of water soluble vitamins in food samples.