• 제목/요약/키워드: Reference Voltage Control

검색결과 594건 처리시간 0.022초

전력 품질 향상을 위한 배전용 STATCON의 AC전압, 직류결합 전압 및 고조파 보상 제어알고리즘 개발 (The Development of Control Algorithms of D-STATCON for Compensations of AC Voltage and DC Link Voltage and Harmonics Improve the Qeality of Electric Power)

  • 오관일;전영수;이기선;추진부
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.333-337
    • /
    • 1999
  • This paper presents the DQ transfomation space space vector modulation method to devel control algorithm of distribu STATCON(STATic CONdenser) for line volt regulation, dc link voltage regulation harmonics compensation. The Performance an of a PI with ramp comparision and synchro reference frame current controller is carried Based on these analysis, the control perform are desirable to compensate the harmonics a regulate dc link and line voltage of Distrib line.

  • PDF

오존발생장치용 정출력 전원장치의 개발 (Development of Constant Output Power Supply System for Ozonizer)

  • 우정인;우성훈;노인배;박지호;김동완
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.113-121
    • /
    • 2005
  • 본 논문에서는 오존발생장치의 전원측 파형에 포함되는 고주파수의 노이즈를 제거하고, 디지털 궤환 제어에 의해 오존 출력을 제어하기 위하여 전원장치의 출력측 LC 필터와 방전관 용량으로부터 커패시터 전압과 전류를 검출하여 2중의 제어루프를 설계하였다. 디지털 제어기의 연산지연시간을 보상하기 위하여 연산지연시간을 전원장치 플랜트의 고유한 파라미터로 가정하고, 플랜트 모델에 포함시켜 모델링 하였다. 오존발생장치의 부하변동에 따르는 과도상태 응답특성을 개선하고, 파라미터 변동에 강인한 특성을 얻기 위하여 내부 전류 모델 제어기를 제안하였다. 또한 오존발생장치용 전원장치에서 영 오차의 정상 상태를 얻기 위하여 외부 전압 제어루프를 구성하여 비례 제어기와 공진 제어기를 병렬로 연결한 비례-공진 전압제어기를 제안하였다.

UPS 인버터의 디지털 제어기 및 모니터링 시스템의 개발 (Development of Digital Controller and Monitoring System for UPS Inverter)

  • 박지호;황기현;김동완
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.1-11
    • /
    • 2007
  • 본 논문에서는 UPS 인버터의 성능 개선을 위하여 출력측 LC 필터의 커패시터 전압과 전류의 2중 제어루프를 구성하고, 2중 제어루프에 디지털 제어시스템을 설계하였다. 또한, 디지털 제어기의 연산지연시간을 보상하기 위하여 이러한 연산지연시간을 인버터 플랜트의 고유한 파라미터로 가정하고, 플랜트 모델에 포함시켜 모델링 하였다. UPS 인버터 출력전압의 과도상태 응답특성을 개선하고, 파라미터 변동에 강인한 특성을 얻기 위하여 2중 제어루프에서 내부 전류 제어루프는 내부 모델 제어기를 제안하였다. UPS 인버터 출력전압의 0의 정상상태 오차를 얻기 위하여 외부 전압 제어루프는 비례 제어기와 공진 제어기를 병렬로 연결한 비례-공진 전압제어기를 제안하였다. 또한, 사용자에게 쉽게 UPS의 동작 상태를 표시하기 위하여 그래픽 사용자 인터페이스를 이용한 UPS의 모니터링 시스템을 구현하였다.

Common-Mode Voltage and Current Harmonic Reduction for Five-Phase VSIs with Model Predictive Current Control

  • Vu, Huu-Cong;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1477-1485
    • /
    • 2019
  • This paper proposes an effective model predictive current control (MPCC) that involves using 10 virtual voltage vectors to reduce the current harmonics and common-mode voltage (CMV) for a two-level five-phase voltage source inverter (VSI). In the proposed scheme, 10 virtual voltage vectors are included to reduce the CMV and low-order current harmonics. These virtual voltage vectors are employed as the input control set for the MPCC. Among the 10 virtual voltage vectors, two are applied throughout the whole sampling period to reduce current ripples. The two selected virtual voltage vectors are based on location information of the reference voltage vector, and their duration times are calculated using a simple algorithm. This significantly reduces the computational burden. Simulation and experimental results are provided to verify the effectiveness of the proposed scheme.

저궤도 위성 자세제어용 자이로 고전압 발생기 설계 (The Gyro High Voltage Power Supply Design for Attitude Control in the Satellite)

  • 김의찬;이흥호
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.403-408
    • /
    • 2008
  • The gyroscope is the sensor for detecting the rotation in inertial reference frame and constitute the navigation system together an accelerometer. As the inertial reference equipment for attitude determination and control in the satellite, the mechanical gyroscope has been used but it bring the disturbance for mass unbalance so the disturbance give a bad influence to the observation satellite mission because the mechanical gyroscope has the rotation parts. During the launch. The mechanical gyroscope is weak in vibration, shock and has the defect of narrow operating temperature range so it need the special design in integration. Recently the low orbit observation satellite for seeking the high pointing accuracy of image camera payload accept the FOG(Fiber Optic Gyro) or RLG(Ring Laser Gyro) for the attitude determination and control. The Ring Laser Gyro makes use of the Sanac effect within a resonant ring cavity of a He-Ne laser and has more accuracy than the other gyros. It need the 1000V DC to create the He-Ne plasma in discharge tube. In this paper, the design process of the High Voltage Power Supply for RLG(Ring Laser Gyroscope) is described. The specification for High Voltage Power Supply (HVPS) is proposed. Also, The analysis of flyback converter topology is explained. The Design for the HVPS is composed of the inverter circuit, feedback control circuit, high frequency switching transformer design and voltage doubler circuit.

IPMSM의 맥동하는 구형파 신호 주입 센서리스 제어를 위한 정지좌표계상에서의 새로운 위치 추정 기법 (A Novel Rotor Position Estimation Method using a Rotation Matrix for a Square-Wave Signal Injected Sensorless Control in IPMSM)

  • 김상일;김래영
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.215-223
    • /
    • 2016
  • In this study, a novel rotor position sensorless estimation method of an interior permanent-magnet synchronous motor is proposed. A square-wave pulsating voltage signal is injected in the estimated synchronous reference frame. This signal is interpreted in the stationary reference frame regardless of the estimated rotor position. Thus, assuming that the position error is nearly zero is unnecessary because the variables in the estimated synchronous reference frame are not used. The rotor position can be exactly calculated from two voltage references and three sampled current feedbacks in the stationary reference frame. The proposed method is easy to implement and helps enhance the bandwidth of the current controller. The validity of the proposed method is verified by simulations and experiments.

Adaline-Based Control of Capacitor Supported DVR for Distribution System

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.386-395
    • /
    • 2009
  • In this paper, a new control algorithm for the dynamic voltage restorer (DVR) is proposed to regulate the load terminal voltage during various power quality problems that include sag, swell, harmonics and unbalance in the voltage at the point of common coupling (PCC). The proposed control strategy is an Adaline (Adaptive linear element) Artificial Neural Network (ANN) and is used to control a capacitor supported DVR for power quality improvement. A capacitor supported DVR does not need any active power during steady state because the voltage injected is in quadrature with the feeder current. The control of the DVR is implemented through derived reference load terminal voltages. The proposed control strategy is validated through extensive simulation studies using the MATLAB software with its Simulink and SimPower System (SPS) toolboxes. The DVR is found suitable to support its dc bus voltage through the control under various disturbances.

Design of Simple Neuro-controller for Global Transient Control and Voltage Regulation of Power Systems

  • Jalili-Kharaajoo Mahdi;Mohammadi-Milasi Rasoul
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권spc2호
    • /
    • pp.302-307
    • /
    • 2005
  • A novel neuro controller based simple neuro-structure with modified error function is introduced in this paper. This controller consists of two independent controllers, known as the voltage regulator and the angular controller. The voltage regulator is used to modify terminal voltage for the purpose of tracking a reference voltage. The angular controller is utilized to guarantee the stability of the system. In this structure each neuron uses a linear hard limit activation function that depends on the controlled variable and its derivatives. There is no need for parameter identification or any off-line training data. Two proposed controllers are merged by a smooth switch to build a complete controller. The effectiveness of the proposed novel control action is demonstrated through some computer simulations on a Single-Machine Infinite-Bus (SMIB) power system.

평균 모델을 이용한 Z-소스 인버터의 제어 (Control of the Z-Source Inverter using Average Model)

  • 이광운
    • 전력전자학회논문지
    • /
    • 제19권3호
    • /
    • pp.290-296
    • /
    • 2014
  • This paper presents a design strategy for the control of the Z-source inverter (ZSI). For the Z-network capacitor voltage control, the average current model is derived to describe the dynamics of the voltage control and the controller outputs the average current command for the capacitor. Z-network inductor current reference is derived from the average current model of the Z-network capacitor. The inner current control loop outputs the average voltage command for the Z-network inductor and the shoot-through duty ratio of the ZSI is calculated from the output using the average voltage model of the Z-network inductor. The gain values of the current and voltage controllers are directly obtained by the Z-network parameters and desired bandwidth of each controller without a gain tuning process.

Implementation of a Non-Linear Adaptive Filter Based Sag Detection Method for Dynamic Voltage Restorers under Unbalanced Fault Conditions

  • Cuma, M. Ugras;Teke, Ahmet;Meral, M. Emin;Bayindir, K. Cagatay;Tumay, Mehmet
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.304-312
    • /
    • 2013
  • The most common power quality problems in distribution systems are related to unbalanced voltage sags. Voltage sags must be detected quickly and corrected in a minimum amount of time. One of the most widely used methods for sag detection is based on the d-q transformation. This method has the disadvantage of missing the detection of unbalanced faults, because this method uses a voltage sag level signal obtained from the average of 3 phases for sag detection. In this paper, an adaptive filter sag detection method is proposed for Dynamic Voltage Restorers (DVR) under unbalanced fault conditions. The proposed DVR controller is able to detect balanced, unbalanced and single phase voltage sags. A novel reference voltage generation method is also presented. To validate the proposed control methods, a 3-phase DSP controlling a DVR prototype with a power rating of 1.5-kVA has been developed. Finally, experimental results are presented to verify the performance of the proposed control methods.