• Title/Summary/Keyword: Reference Spectrum

Search Result 327, Processing Time 0.011 seconds

A study on Optimization of Reference Spectrum for Improvement of Fixture Performance in Random Vibration Control (랜덤진동제어에서 치구성능향상을 위한 기준스펙트럼의 최적화에 대한 연구)

  • 김준엽;정의봉
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.284-291
    • /
    • 1995
  • This paper proposes a method for determination of optimal reference spectrum in random vibration control. The least square method is used to minimize the spectrum deviation between the specified reference spectrum and spectra at the specimen-mounted points. This method needs only the measured FRF's at the control point and specimen-mounted points in pre-vibration test. Using the proposed method as reference spectrum, it is possible to easily predict spectra at the specimen-mounted points, and also to reduce overtest resulting from dynamic characteristics of shaker and fixture. This method is shown through theoretical and experimental results to be an effective method.

STANDARIZING THE EXTRATERRESTRIAL SOLAR IRRADIANCE SPECTRUM FOR CAL/VAL OF GEOSTATIONARY OCEAN COLOR IMAGER (GOCI)

  • Shanmugam, Palanisamy;Ahn, Yu-Hwan
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.86-89
    • /
    • 2006
  • Ocean color remote sensing community currently uses the different solar irradiance spectra covering the visible and near-infrared in the calibration/validation and deriving products of ocean color instruments. These spectra derived from single and / or multiple measurements sets or models have significant discrepancies, primarily due to variation of the solar activity and uncertainties in the measurements from various instruments and their different calibration standards. Thus, it is prudent to examine model-to-model differences and select a standard reference spectrum that can be adopted in the future calibration and validation processes, particularly of the first Geostationary Ocean Color Imager (GOCI) onboard its Communication Ocean and Meterological Satellite (COMS) planned to be launched in 2008. From an exhaustive survey that reveals a variety of solar spectra in the literature, only eight spectra are considered here seeing as reference in many remote sensing applications. Several criteria are designed to define the reference spectrum: i.e., minimum spectral range of 350-1200nm, based completely or mostly on direct measurements, possible update of data and less errors. A careful analysis of these spectra reveals that the Thuillier 2004 spectrum seems to be very identical compared to other spectra, primarily because it represents very high spectral resolution and the current state of the art in solar irradiance spectra of exceptionally low uncertainty ${\sim}0.1%.$ This study also suggests use of the Gueymard 2004 spectrum as an alternative for applications of multispectral/multipurpose satellite sensors covering the terrestrial regions of interest, where it provides spectral converge beyond 2400nm of the Thuillier 2004 spectrum. Since the solar-activity induced spectral variation is about less than 0.1% and a large portion of this variability occurs particularly in the ultraviolet portion of the electromagnetic spectrum that is the region of less interest for the ocean color community, we disregard considering this variability in the analysis of solar irradiance spectra, although determine the solar constant 1366.1 $Wm^{-2}$ to be proposed for an improved approximation of the extraterrestrial solar spectrum in the visible and NIR region.

  • PDF

Experimental Structural Dynamic Modification of Fixture for Vibration Testing (진동시험용 치구의 실험적 구조변경 설계)

  • 정의봉;오영세;김준엽
    • Journal of KSNVE
    • /
    • v.8 no.1
    • /
    • pp.180-186
    • /
    • 1998
  • Vibration test fixture is used in random vibration control testing. The specified reference spectrum should be transmitted equally to the specimen attachment points on the fixture. In most practical cases, however, spectrum at each of specimen attachment points may be quite different from the specified reference spectrum because of the dynamic characteristics of vibration test fixture. This paper proposes the method of experimental dynamic modification of fixture system for vibration test so that the reference spectrum can be transmitted to the specimen attachment points without distortion. The stiffness of mounts of specimen and the thickness of fixture are considered as design variables. The frequency response functions of specimen used for input data are obtained from vibration testing, and the frequency response functions of fixture are obtained from finite element modeling. The sensitivities of frequency response functions at specimen attachment points to the mount stiffness are derived from synthesis method of transfer function. And the sensitivities to the thickness of fixture are also derived from finite element modeling. The presented method is verified by computer simulation and vibration testing.

  • PDF

Efficient Rotor Fault Detection of Induction Motors Using Stator Current Spectrum Monitoring (고정자 전류 스펙트럼 모니터링을 이용한 효과적인 유도전동기 회전자 고장 걸출)

  • 정춘호;우혁재;송명현;강의성;김경민
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.6
    • /
    • pp.873-878
    • /
    • 2002
  • Stator current spectrum by the fast Fourier transform (FFT) of current signals has been widely used for fault detection in induction motors. In this paper, we propose efficient rotor fault detection of Induction motors using stator current spectrum monitoring. The proposed method utilizes the mean absolute difference (MAD) between a Predetermined reference vector and a feature vector extracted from the stator current spectrum. Our proposed approach requires a smaller amount of computations when compared to fault detection algorithms based on neural networks, since it uses simple MAD criterion to detect rotor faults related broken rotor bars. Experimental results show that our proposed method can successively detect the rotor fault of the induction motor.

Measurement and Analysis of the Korean NDGPS Radiation Spectrum

  • Kim, Young-Wan;Jee, Suk-Kun
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.3
    • /
    • pp.225-230
    • /
    • 2012
  • The Korean nationwide differential global positioning system (NDGPS) reference station transmits a global positioning system (GPS) enhancement signal using minimum shift keying modulation with a 200 bps data rate. The ocean-based DGPS covers the service area of 100 NM with 300 W output power; on the other hand, the land-based DGPS transmits the output power of 500 W, which covers the service area of 100 km. The DGPS reference stations with high output power can radiate spurious signals, which may act as interference sources affecting the other DGPS reference stations or the wireless ground stations that utilize the medium frequency band. In this paper, the radiation spectrums of the DGPS reference stations are measured and analyzed in the spurious domain. The DGPS radiation spectrums are evaluated from the perspective of the interference effect.

Wavelength selection by loading vector analysis in determining total protein in human serum using near-infrared spectroscopy and Partial Least Squares Regression

  • Kim, Yoen-Joo;Yoon, Gil-Won
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4102-4102
    • /
    • 2001
  • In multivariate analysis, absorbance spectrum is measured over a band of wavelengths. One does not often pay attention to the size of this wavelength band. However, it is desirable that spectrum is measured at only necessary wavelengths as long as the acceptable accuracy of prediction can be met. In this paper, the method of selecting an optimal band of wavelengths based on the loading vector analysis was proposed and applied for determining total protein in human serum using near-infrared transmission spectroscopy and PLSR. Loading vectors in the full spectrum PLSR were used as reference in selecting wavelengths, but only the first loading vector was used since it explains the spectrum best. Absorbance spectra of sera from 97 outpatients were measured at 1530∼1850 nm with an interval of 2 nm. Total protein concentrations of sera were ranged from 5.1 to 7.7 g/㎗. Spectra were measured by Cary 5E spectrophotometer (Varian, Australia). Serum in the 5 mm-pathlength cuvette was put in the sample beam and air in the reference beam. Full spectrum PLSR was applied to determine total protein from sera. Next, the wavelength region of 1672∼1754 nm was selected based on the first loading vector analysis. Standard Error of Cross Validation (SECV) of full spectrum (1530∼l850 nm) PLSR and selected wavelength PLSR (1672∼1754 nm) was respectively 0.28 and 0.27 g/㎗. The prediction accuracy between the two bands was equal. Wavelength selection based on loading vector in PLSR seemed to be simple and robust in comparison to other methods based on correlation plot, regression vector and genetic algorithm. As a reference of wavelength selection for PLSR, the loading vector has the advantage over the correlation plot since the former is based on multivariate model whereas the latter, on univariate model. Wavelength selection by the first loading vector analysis requires shorter computation time than that by genetic algorithm and needs not smoothing.

  • PDF

Simulation of a Non-Directional Wave Spectrum Analysis with Welch's Method

  • Park, Soo-Hong
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.2
    • /
    • pp.146-149
    • /
    • 2008
  • Simulation and signal conditioning on the time domain surface elevation records are conducted to verify the proposed Welch's method in non-directional ocean wave spectrum analysis. These spectrum data are further conditioned to provide wave characteristic that better describe the sea states. Comparison of significant wave height and zero crossing period between the proposed method and a reference toolkit are presented.

Computation of Uniform Hazard Spectrum for Wolsong Nuclear Power Plants. (월성 원전 부지의 등재해도 스펙트럼 계산)

  • 신진수
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.297-303
    • /
    • 1998
  • The uniform hazard spectrum of Wolsong Nuclear Power plant Site is computed in order to estimate probabilistically the characteristics of spectral ground response. The spectral hazard values calculated from the seismic zoning maps proposed by eight seismologist are combined with equal weight to produce a uniform hazard spectrum. The uniform hazardd spectra corresponding to reference probabilities of 1.0 $\times$10-4/year and 1.0$\times$10-5/year are presented, which largely depend on the spectral attenuation relation. The computational results of this study contribute to verify the conservatism of the design ground spectrum of Wolsong Nuclear Power Plant.

  • PDF

A Detection Method of Position of ON/OFF-Switch (ON/OFF-스위치의 위치 인식 방법)

  • Cho, Byung-Mo;Lee, Kwon-Yeon;Son, Myung-Sik
    • Journal of IKEEE
    • /
    • v.11 no.1 s.20
    • /
    • pp.30-37
    • /
    • 2007
  • This paper proposes a detection method of position of OFF-switch. Each switch has the parallel path with a serial combination of passive element, its parallel path has each different frequency characteristics. Frequency characteristic of ON-switch reveals a flat spectrum irrelevant to frequency characteristic of passive element connected in parallel to its each terminal and frequency characteristic of OFF-switch reveals the same characteristic as one of passive element connected in parallel. Detection of position of OFF-switch is done by measuring the similarity of each spectrum corresponding to frequency characteristic of passive element connected in parallel to OFF-switch. The measure of their similarity is to calculate Euclidean distance between their test spectrum and reference spectrum. The spectrum with the smallest distance among reference spectrum is recognized as the spectrum of OFF-switch. The real time digital signal processing system is implemented to detect the position of OFF-switch by using spectrum matching.

  • PDF

Suppressing Harmonics in Delta Modulation by Synchronization Hysteresis with the Reference Signal

  • Aurasopon, Apinan;Kumhom, Pinit
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.409-412
    • /
    • 2002
  • The delta modulation used for controlling the speed of an induction motor has high peak of harmonic spectrum at low speed range causing acoustic noises in the induction motor. This paper proposes to suppress the harmonics by synchronizing the reference signal with the hysteresis windows for controlling the distribution of the switching frequency. As a result we can decrease the peak of harmonic spectrum. The simulation results show that the peak spectrum of harmonics can be reduced up to 60%.

  • PDF