• 제목/요약/키워드: Reference Spectrum

검색결과 327건 처리시간 0.025초

랜덤진동제어에서 치구성능향상을 위한 기준스펙트럼의 최적화에 대한 연구 (A study on Optimization of Reference Spectrum for Improvement of Fixture Performance in Random Vibration Control)

  • 김준엽;정의봉
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.284-291
    • /
    • 1995
  • This paper proposes a method for determination of optimal reference spectrum in random vibration control. The least square method is used to minimize the spectrum deviation between the specified reference spectrum and spectra at the specimen-mounted points. This method needs only the measured FRF's at the control point and specimen-mounted points in pre-vibration test. Using the proposed method as reference spectrum, it is possible to easily predict spectra at the specimen-mounted points, and also to reduce overtest resulting from dynamic characteristics of shaker and fixture. This method is shown through theoretical and experimental results to be an effective method.

STANDARIZING THE EXTRATERRESTRIAL SOLAR IRRADIANCE SPECTRUM FOR CAL/VAL OF GEOSTATIONARY OCEAN COLOR IMAGER (GOCI)

  • Shanmugam, Palanisamy;Ahn, Yu-Hwan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.86-89
    • /
    • 2006
  • Ocean color remote sensing community currently uses the different solar irradiance spectra covering the visible and near-infrared in the calibration/validation and deriving products of ocean color instruments. These spectra derived from single and / or multiple measurements sets or models have significant discrepancies, primarily due to variation of the solar activity and uncertainties in the measurements from various instruments and their different calibration standards. Thus, it is prudent to examine model-to-model differences and select a standard reference spectrum that can be adopted in the future calibration and validation processes, particularly of the first Geostationary Ocean Color Imager (GOCI) onboard its Communication Ocean and Meterological Satellite (COMS) planned to be launched in 2008. From an exhaustive survey that reveals a variety of solar spectra in the literature, only eight spectra are considered here seeing as reference in many remote sensing applications. Several criteria are designed to define the reference spectrum: i.e., minimum spectral range of 350-1200nm, based completely or mostly on direct measurements, possible update of data and less errors. A careful analysis of these spectra reveals that the Thuillier 2004 spectrum seems to be very identical compared to other spectra, primarily because it represents very high spectral resolution and the current state of the art in solar irradiance spectra of exceptionally low uncertainty ${\sim}0.1%.$ This study also suggests use of the Gueymard 2004 spectrum as an alternative for applications of multispectral/multipurpose satellite sensors covering the terrestrial regions of interest, where it provides spectral converge beyond 2400nm of the Thuillier 2004 spectrum. Since the solar-activity induced spectral variation is about less than 0.1% and a large portion of this variability occurs particularly in the ultraviolet portion of the electromagnetic spectrum that is the region of less interest for the ocean color community, we disregard considering this variability in the analysis of solar irradiance spectra, although determine the solar constant 1366.1 $Wm^{-2}$ to be proposed for an improved approximation of the extraterrestrial solar spectrum in the visible and NIR region.

  • PDF

진동시험용 치구의 실험적 구조변경 설계 (Experimental Structural Dynamic Modification of Fixture for Vibration Testing)

  • 정의봉;오영세;김준엽
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.180-186
    • /
    • 1998
  • Vibration test fixture is used in random vibration control testing. The specified reference spectrum should be transmitted equally to the specimen attachment points on the fixture. In most practical cases, however, spectrum at each of specimen attachment points may be quite different from the specified reference spectrum because of the dynamic characteristics of vibration test fixture. This paper proposes the method of experimental dynamic modification of fixture system for vibration test so that the reference spectrum can be transmitted to the specimen attachment points without distortion. The stiffness of mounts of specimen and the thickness of fixture are considered as design variables. The frequency response functions of specimen used for input data are obtained from vibration testing, and the frequency response functions of fixture are obtained from finite element modeling. The sensitivities of frequency response functions at specimen attachment points to the mount stiffness are derived from synthesis method of transfer function. And the sensitivities to the thickness of fixture are also derived from finite element modeling. The presented method is verified by computer simulation and vibration testing.

  • PDF

고정자 전류 스펙트럼 모니터링을 이용한 효과적인 유도전동기 회전자 고장 걸출 (Efficient Rotor Fault Detection of Induction Motors Using Stator Current Spectrum Monitoring)

  • 정춘호;우혁재;송명현;강의성;김경민
    • 한국정보통신학회논문지
    • /
    • 제6권6호
    • /
    • pp.873-878
    • /
    • 2002
  • 고정자 전류 스펙트럼(stator current spectrum)은 유도전동기의 고장 검출에 널리 사용되어왔다. 본 논문에서는 고정자 전류 스펙트럼 중에서 회전자 고장에 의해서 큰 영향을 받는 주파수 성분들로 특징벡터(feature vector)를 구성하고, 특징벡터와 기준벡터(reference vector)와의 평균 절대치 차이(mean absolute difference)를 구함으로써, 회전자 고장을 검출하는 방법을 제안한다. 제안한 방법에서는 전류 스펙트럼 중에서 추출된 매우 작은 크기(dimension)의 특징 벡터에 대한 평균 절대치 차이를 이용하기 때문에 신경회로망에 의한 고장 검출 알고리즘 둥에 비해서 훨씬 적은 계산량만으로 모터의 고장을 효율적으로 검출할 수 있다

Measurement and Analysis of the Korean NDGPS Radiation Spectrum

  • Kim, Young-Wan;Jee, Suk-Kun
    • Journal of information and communication convergence engineering
    • /
    • 제10권3호
    • /
    • pp.225-230
    • /
    • 2012
  • The Korean nationwide differential global positioning system (NDGPS) reference station transmits a global positioning system (GPS) enhancement signal using minimum shift keying modulation with a 200 bps data rate. The ocean-based DGPS covers the service area of 100 NM with 300 W output power; on the other hand, the land-based DGPS transmits the output power of 500 W, which covers the service area of 100 km. The DGPS reference stations with high output power can radiate spurious signals, which may act as interference sources affecting the other DGPS reference stations or the wireless ground stations that utilize the medium frequency band. In this paper, the radiation spectrums of the DGPS reference stations are measured and analyzed in the spurious domain. The DGPS radiation spectrums are evaluated from the perspective of the interference effect.

Wavelength selection by loading vector analysis in determining total protein in human serum using near-infrared spectroscopy and Partial Least Squares Regression

  • Kim, Yoen-Joo;Yoon, Gil-Won
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.4102-4102
    • /
    • 2001
  • In multivariate analysis, absorbance spectrum is measured over a band of wavelengths. One does not often pay attention to the size of this wavelength band. However, it is desirable that spectrum is measured at only necessary wavelengths as long as the acceptable accuracy of prediction can be met. In this paper, the method of selecting an optimal band of wavelengths based on the loading vector analysis was proposed and applied for determining total protein in human serum using near-infrared transmission spectroscopy and PLSR. Loading vectors in the full spectrum PLSR were used as reference in selecting wavelengths, but only the first loading vector was used since it explains the spectrum best. Absorbance spectra of sera from 97 outpatients were measured at 1530∼1850 nm with an interval of 2 nm. Total protein concentrations of sera were ranged from 5.1 to 7.7 g/㎗. Spectra were measured by Cary 5E spectrophotometer (Varian, Australia). Serum in the 5 mm-pathlength cuvette was put in the sample beam and air in the reference beam. Full spectrum PLSR was applied to determine total protein from sera. Next, the wavelength region of 1672∼1754 nm was selected based on the first loading vector analysis. Standard Error of Cross Validation (SECV) of full spectrum (1530∼l850 nm) PLSR and selected wavelength PLSR (1672∼1754 nm) was respectively 0.28 and 0.27 g/㎗. The prediction accuracy between the two bands was equal. Wavelength selection based on loading vector in PLSR seemed to be simple and robust in comparison to other methods based on correlation plot, regression vector and genetic algorithm. As a reference of wavelength selection for PLSR, the loading vector has the advantage over the correlation plot since the former is based on multivariate model whereas the latter, on univariate model. Wavelength selection by the first loading vector analysis requires shorter computation time than that by genetic algorithm and needs not smoothing.

  • PDF

Simulation of a Non-Directional Wave Spectrum Analysis with Welch's Method

  • Park, Soo-Hong
    • Journal of information and communication convergence engineering
    • /
    • 제6권2호
    • /
    • pp.146-149
    • /
    • 2008
  • Simulation and signal conditioning on the time domain surface elevation records are conducted to verify the proposed Welch's method in non-directional ocean wave spectrum analysis. These spectrum data are further conditioned to provide wave characteristic that better describe the sea states. Comparison of significant wave height and zero crossing period between the proposed method and a reference toolkit are presented.

월성 원전 부지의 등재해도 스펙트럼 계산 (Computation of Uniform Hazard Spectrum for Wolsong Nuclear Power Plants.)

  • 신진수
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.297-303
    • /
    • 1998
  • The uniform hazard spectrum of Wolsong Nuclear Power plant Site is computed in order to estimate probabilistically the characteristics of spectral ground response. The spectral hazard values calculated from the seismic zoning maps proposed by eight seismologist are combined with equal weight to produce a uniform hazard spectrum. The uniform hazardd spectra corresponding to reference probabilities of 1.0 $\times$10-4/year and 1.0$\times$10-5/year are presented, which largely depend on the spectral attenuation relation. The computational results of this study contribute to verify the conservatism of the design ground spectrum of Wolsong Nuclear Power Plant.

  • PDF

ON/OFF-스위치의 위치 인식 방법 (A Detection Method of Position of ON/OFF-Switch)

  • 조병모;이권연;손명식
    • 전기전자학회논문지
    • /
    • 제11권1호통권20호
    • /
    • pp.30-37
    • /
    • 2007
  • 본 논문은 직렬로 연결된 스위치의 OFF-위치를 감지할 수 있는 방법을 제안한다. 각각의 스위치에는 병렬로 각기 다른 주파수 특성을 갖는 수동 소자가 병렬로 연결되어 있다. ON된 스위치에는 병렬로 연결된 수동 소자의 주파수 특성에 관계없이 평탄한 특성을 갖으며, OFF된 스위치의 경우에는 연결된 수동소자의 주파수 특성이 스위치의 양 단자에 나타난다. OFF된 스위치의 위치 인식은 직렬로 연결된 스위치의 양 단자에 백색 잡음(Maximum-Length Sequence)을 입력하고, 각각의 스위치를 OFF한 상태에서 출력 단자에서 스펙트럼을 계산하여 미리 참조 스펙트럼을 작성하고, 작성된 참조 스펙트럼과 입력 스펙트럼 간의 유사도를 계산하여 가장 근접한 참조 스펙트럼을 OFF된 스위치의 스펙트럼으로 인식한다. 이를 위한 디지털 신호처리 시스템을 설계하고, 설계된 시스템을 이용하여 스펙트럼 매칭으로 OFF-스위치의 위치를 감지한다.

  • PDF

Suppressing Harmonics in Delta Modulation by Synchronization Hysteresis with the Reference Signal

  • Aurasopon, Apinan;Kumhom, Pinit
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.409-412
    • /
    • 2002
  • The delta modulation used for controlling the speed of an induction motor has high peak of harmonic spectrum at low speed range causing acoustic noises in the induction motor. This paper proposes to suppress the harmonics by synchronizing the reference signal with the hysteresis windows for controlling the distribution of the switching frequency. As a result we can decrease the peak of harmonic spectrum. The simulation results show that the peak spectrum of harmonics can be reduced up to 60%.

  • PDF