• Title/Summary/Keyword: Reduction Unit

Search Result 1,343, Processing Time 0.034 seconds

Hydration Heat Properties of High Flowing Self-Compacting Concrete with Normal Strength (보통강도 고유동 자기충전 콘크리트의 수화발열 특성)

  • Choi, Yun-Wang;Kim, Byoung-Kwon;Lee, Jae-Nam;Ryu, Deug-Hyun;Song, Yong-Kyu;Jung, Woo-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.497-500
    • /
    • 2008
  • This research carries out experiments for hydration exothermic rate and adiabatic temperature rise of concrete to examine the characteristics of the hydration heat of high flowing self-compacting concrete with a normal strength. As a result of the hydration exothermic rate experiment, the high flowing self-compacting concrete that used Lime stone powder and fly ash as polymers shows that its hydration heat amount reduces due to the reduction of unit cement. The result measured the adiabatic temperature rise of concrete presents that high flowing self-compacting concrete having lots of binder contents has a good performance in temperature reduction due to the effect of polymer and that triple adding high flowing self-compacting concrete has a similar temperature rise speed with conventional concrete. As a result of the research, high flowing self-compacting concrete shows a better temperature reduction performance for the binder content per unit than conventional concrete. In addition, it is judged that triple adding high flowing self-compacting concrete with a specified concrete strength 30 MPa is more beneficial in temperature reduction and early hydration heat than double adding high flowing self-compacting concrete.

  • PDF

Effects of Washing and Storage Temperature on Quality and Safety of Washed Shell Eggs (세척 수 및 보관온도가 세척 식용란 품질과 안전에 미치는 영향)

  • Choi, Bum-Geun;Min, Ji-Hyeon;Yoon, Ki-Sun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.27 no.1
    • /
    • pp.78-87
    • /
    • 2017
  • The objective of this study was to investigate the effects of various washing waters on the quality and safety characteristics of eggs during storage. Eggs were washed with tap water, 100 ppm of sodium hypochlorite, or 30 ppm of slightly acidic electrolyzed water and stored at $10^{\circ}C$ and $20^{\circ}C$. Effects of various washing waters on reduction of Salmonella Enteritidis and aerobic plate counts and survival of S. Enteritidis on egg shells were also analyzed at $10^{\circ}C$ and $20^{\circ}C$ for 25 days. As an index of quality, haugh unit, weight reduction, and pHs of egg white and egg yolk were measured. Reduction percentages of haugh unit and weight were higher at $20^{\circ}C$ than at $10^{\circ}C$. Egg qualities were less affected by tap water, slightly acidic electrolyzed water, and sodium hypochlorite, regardless of storage temperature. The greatest reductions in aerobic plate counts and S. Enteritidis were observed with slightly acidic electrolyzed water. The level of S. Enteritidis on egg shells gradually decreased during 20 days of storage at both $10^{\circ}C$ and $20^{\circ}C$, whereas S. Enteritidis survived longer at $20^{\circ}C$ than at $10^{\circ}C$. S. Enteritidis was not detected in eggs at $10^{\circ}C$, 2.13 log CFU/g of S. Enteritidis was detected in eggs washed with sodium hypochlorite after 20 days of storage at $20^{\circ}C$, indicating that S. Enteritidis penetrated into the egg shell during storage at $20^{\circ}C$. In conclusion, slightly acidic electrolyzed water increased microbial reduction and least affected quality of washed eggs. Thus, slightly acidic electrolyzed water can be recommended for washing of graded eggs, at retail markets.

A Study on the Energy Performance Evaluation of Building Evaporative Cooling System for Building Construction in Response to Climate Change (기후변화 대응 저에너지 건축물 조성을 위한 건축물 기화냉각시스템 에너지성능평가 연구)

  • Kwon, Ki-Uk
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.1
    • /
    • pp.54-60
    • /
    • 2019
  • The recent climate change is exacerbating the external thermal environment and increasing the amount of energy used in building. Energy Plus was used to evaluate low energy technology performance of buildings responding to climate change. The test types of basic building(control) and evaporative mist system + basic building(EMS), and the analysis results of each type are compared. Energy performance evaluation result, Cooling peak load were EMS reduction compared to control is about 9%. Annual cooling load per unit area were EMS reduction compared to control is about 17%. Annual energy use per unit area were EMS reduction compared to control is about 10%. Therefore, the effect of the evaporative cooling system is considered to be good through energy reduction technology of building, according to the amount and distance of the evaporative mist system in the future research on building energy performance evaluation should be carried out.

Die Stress Reduction Design and Mechanical Properties Analysis of Warm Forging Process for the Application of Warm-Closed Forging of Automative Steering Unit Yoke (자동차 조향장치 부품 요크의 온간 밀폐 단조 적용을 위한 금형 응력 저감 설계 및 온간 단조품의 기계적 특성 분석)

  • Seong, S.G.;Kim, K.H.;Lee, Y.S.;Lee, S.Y.;Yoon, E.Y.
    • Transactions of Materials Processing
    • /
    • v.31 no.2
    • /
    • pp.51-56
    • /
    • 2022
  • In this study, finite element analyses were performed by applying a stress ring and split die design to relieve the tensile stress acting on the die due to high surface pressure during warm-closed forging. The applied material was a yield-ratio-control-steel (YRCS). It was used without quenching or tempering after forging. In the case of stress rings design, the number of stress rings and the tolerance for shrink fit were different. Vertical and horizontal splits were applied for insert die split design. Case 5 die with three stress rings, 0.2 % shrink fit tolerance, and vertical split was selected as an effective die design for tensile stress reduction. Based on die stress reduction analyses, Case 5 die for warm-closed forging was produced and smooth forgeability was secured, making it possible to manufacture forging product of yoke with the required geometry. In addition, controlled cooling using warm forging heat was applied to secure mechanical properties of yokes. When oil cooling was used for direct controlled cooling after warm-closed forging, a relatively uniform Rockwell hardness distribution and high mechanical properties could be obtained.

Fast HEVC Encoding based on CU-Depth First Decision (CU 깊이 우선 결정 기반의 HEVC 고속 부호화 방법)

  • Yoo, Sung-Eun;Ahn, Yong-Jo;Sim, Dong-Gyu
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.3
    • /
    • pp.40-50
    • /
    • 2012
  • In this paper we propose the fast CU (Coding Unit) mode decision method. To reduce computational complexity and save encoding time of HEVC, we divided CU, PU (Prediction Unit) and TU (Transform Unit) decision process into two stages. In the first stage, because $2N{\times}2N$ PU mode is mostly selected among $2N{\times}2N$, $N{\times}2N$, $2N{\times}N$, $N{\times}N$ PU modes, proposed algorithm uses only $2N{\times}2N$ PU mode deciding depth of each CU in the LCU (Largest CU). And then, proposed method decides exact PU and TU modes at the depth level which is decided in the first stage. In addition, early skip decision rule is applied to the proposed method to obtain more efficient computational complexity reduction. The proposed method reduces computational complexity of the HEVC encoder by simplifying a CU depth decision method. We could obtain about 50% computational complexity reduction in comparison with HM 3.3 HEVC reference software while bitrate compressed by the proposed algorithm increases only 2%.

Estimating Social Benefits According to Exhaust Gas Reduction Devices (DPF) (배출가스 저감장치(DPF) 부착에 따른 사회적 편익 추정)

  • Choi, Soungkyu;Kim, Yongdal;Kim, Hogyeong;Bae, Jinmin
    • Journal of Auto-vehicle Safety Association
    • /
    • v.10 no.3
    • /
    • pp.27-31
    • /
    • 2018
  • The People have a bad perception about diesel vehicle because of serious air pollution, increase fine dust and global vehicle company's diesel gate. Starting the project in 2005, Ministry of Environment has been supporting that is exhaust gas reduction devices (DPF) on diesel vehicles in the metropolitan area. During the period of 2017.01.01 to 2017.12.31, 10,030 diesel vehicles installed exhaust gas reduction devices (DPF). Among them, 9,921 diesel vehicles that they have sufficient data for analysis were analyzed amount of particulate matter reduction before and after exhaust gas reduction devices (DPF) was installed. Opacity smoke meter measures the concentration of particulate matter. So concentration of particulate matter was converted into a mass unit, and then calculated the total amount of reduced particulate matter. It was estimated that social benefits is costs required to remove it from the total amount of particulate matter.

A Thin Film Transistor LCD Module with Novel OverDriving Timing Controller

  • Yu, Hong-Tien;Huang, Juin-Ying;Tseng, Wen-Tse;Wen, Harchson
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1053-1056
    • /
    • 2004
  • Chunghwa Picture Tubes, LTD. (CPT) has developed a Novel TFT-LCD Driving Techniquel. This new technique is developed in combination with other state-of-the-art image processing solutions such as image compression / decompression, motion detection, and noise reduction. By applying the Novel Driving Technique to the high resolution TFT-LCD, it was found that the response time can be effectively reduced with a lower overall system cost by smaller frame memory requirement, lower EMI by less memory band-width. Likewise, higher display quality can also be achieved in that the unexpected noises generated by over-drive can be eliminated. The Novel TFT-LCD Driving Technique has been successfully implemented to the 30 inch WXGA (1280${\times}$768) resolution TFT LCD commercial TV module. It was found that the quality of moving picture was better improved compared with that of the conventional fast response driving method.

  • PDF

Detection and Control of Variation Source for a Production Unit

  • Xu, Jichao;Akpolat, Hasan
    • International Journal of Quality Innovation
    • /
    • v.4 no.1
    • /
    • pp.148-159
    • /
    • 2003
  • Variation is the archenemy of quality. To reduce or control the variation in a complex production unit, firstly we need to identify the location of the root cause of the variation. This paper discusses the detection of variability and the techniques used for reduction of variation for a production unit consisting of many processes. In the first part of this paper, the background of variability detection in production systems is introduced which is then followed by a weighted network corresponding to correlation matrix of all processes. Based on the network and clustering criterion of maximum spanning tree, a classification of all processes is derived. Furthermore, the variation of each process in a class is determined by residual analysis. In the last part, the use of methods of robust design for the processes with a larger variability is discussed.

Analysing System Marginal Price Reduction through Performing the Unit Commitment including ESS (ESS를 포함한 Unit Commitment 수행을 통한 System Marginal Price 감소효과 분석)

  • Park, Joon-Hyung;Jang, Young-Sik;Kwon, Gu-Min;Kim, Sun-Kyo;Yoon, Yong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.166-167
    • /
    • 2011
  • 본 논문에서는 전력 소비자 입장에서 전력가격에 큰 비중을 차지하는 System Marginal Cost(SMP)를 줄이는 방법으로 ESS를 포함하여 Unit Commitment(UC)를 수행하는 방법과 그에 따른 효과를 분석하였다. 먼저 본 논문에서는 일반적인 UC를 Lagrangian Relaxation(LR) 기법으로 얻은 최적의 결과 값을 토대로 ESS를 추가하였다. 기존의 LR알고리즘으로부터 얻은 결과 값에 ESS를 추가하는 방법으로는 Dynamic Programming 방법의 한 종류인 Label Correcting Methods[]를 사용하였다. 기존의 UC 알고리즘 결과 값을 토대로 ESS를 추가하여 SMP 감소효과 분석을 위해 실 계통에서 사용되는 종류별 발전기 10대와 임의적으로 설정한 24시간의 부하 값을 토대로 MATLAB을 이용해서 구현하였고, 결과 값을 통해 실질적인 SMP 감소효과 유무를 확인할 수 있었다.

  • PDF

Method of SSO Noise Reduction on FPGA of Digital Optical Units in Optical Communication

  • Kim, Jae Wan;Eom, Doo Seop
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.97-101
    • /
    • 2013
  • There is a growing need for optical communication systems that convert large volumes of data to optical signals and that accommodate and transmit the signals across long distances. Digital optical communication consists of a master unit (MU) and a slave unit (SU). The MU transmits data to SU using digital optical signals. However, digital optical units that are commercially available or are under development transmit data using two's complement representation. At low input levels, a large number of SSOs (simultaneous switching outputs) are required because of the high rate of bit switching in two's complement, which thereby increases the power noise. This problem reduces the overall system capability because a DSP (digital signal processor) chip (FPGA, CPLD, etc.) cannot be used efficiently and power noise increases. This paper proposes a change from two's complement to a more efficient method that produces less SSO noise and can be applied to existing digital optical units.