A Study on the Energy Performance Evaluation of Building Evaporative Cooling System for Building Construction in Response to Climate Change  

Kwon, Ki-Uk (Glocal Industry-Academic Cooperation Foundation, Konkuk University)
Publication Information
Journal of Convergence for Information Technology / v.9, no.1, 2019 , pp. 54-60 More about this Journal
Abstract
The recent climate change is exacerbating the external thermal environment and increasing the amount of energy used in building. Energy Plus was used to evaluate low energy technology performance of buildings responding to climate change. The test types of basic building(control) and evaporative mist system + basic building(EMS), and the analysis results of each type are compared. Energy performance evaluation result, Cooling peak load were EMS reduction compared to control is about 9%. Annual cooling load per unit area were EMS reduction compared to control is about 17%. Annual energy use per unit area were EMS reduction compared to control is about 10%. Therefore, the effect of the evaporative cooling system is considered to be good through energy reduction technology of building, according to the amount and distance of the evaporative mist system in the future research on building energy performance evaluation should be carried out.
Keywords
Evaporative cooling Technology; Energy Plus; Energy performance evaluation; Climate change; Thermal environment;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 S. T. No & J. W. Jeong. (2011). A Study on Comparison of Heating Load by Energy Plus and Web-based Energy Performance Assessment Tool in an Apartment Housing. Journal of the Architectural Institute of Korea, 27(1), 245-252.
2 J. H. Kim, K. U. Kwon & Y. H. Yoon. (2015). Analysis of Building Energy Reduction Effect based on the Green Wall Planting Foundation Type Using a Simulation Program. Korea Society of Environment and Ecology, 29(6), 936-946.   DOI
3 J. H. Kim, K. U. Kwon, C. H. Joo & Y. H. Yoon. (2015). Comparative of Energy-Saving by Green Roof Type on Urban Office Building. Journal of Environmental Science International, 23(8), 1437-1446. DOI : 10.5322/JESI.2014.23.8.1437   DOI
4 H. Takebayashi & M. Moriyama. (2009). Study on the urban heat island mitigation effect achieved by converting to grass-covered parking. Solar Energy, 83(8), 1211-1223. DOI : 10.1016/j.solener.2009.01.019   DOI
5 N. H. Wong. et al. (2010). Thermal evaluation of vertical greenery systems for building walls. Building and environment, 45(3), 663-672. DOI : 10.1016/j.buildenv.2009.08.005   DOI
6 K. Y. Kim, S. H. Kim, H. D. Kim, S. J. Jo & S. M. Bang. (2011). A Study on the Effect temperature decrease of Green Wall in Daegu. Proceedings of the Korean Environmental Sciences Society Conference, Korea, 20, 124-126.
7 H. T. Seok, J. H. Yang & J. W. Jung. (2008). A Study on the Evaluation of Energy Performance According to Greenery Cover in Education Buildings. Journal of the Korean Solar Energy Society 28(6), 40-47.
8 K. C. Yoon, J. U. Jeon & K. S. Kim. (2011). Analysis on the Impact of Load Factors in Building Energy Simulation Affecting Building Energy Consumption. Journal of the Korea institute of ecological architecture and environment, 11(4), 71-78.
9 J. W. Jung, D. W. Kim, H. T. Seok & J. H. Yang. (2010). A Study on the Improvement Plans of Energy Performance in University Building through the Analysis of Energy. Journal of the Korean Solar Energy Society 30(1), 50-60.
10 H. S. Kim, J. S. Kim & O. Y. Im. (2004). Optimal Windows Transmittance by Energy Performance Analysis and Subjective Evaluation in office building. Journal of the Korean Solar Energy Society 24, 73-83.
11 Y. D. Park, E. C. Kang & E. J. Lee. (2007). Energy Performance Simulation Study of Building Energy Reducing Dynamic Insulation. Journal of the Architectural Institute of Korea, 1, 921-926.
12 J. K. Kim. (2012). An Experimental Study on Insulation Effects by the Installation Method of Reflector Type Insulator. Journal of the Architectural Institute of Korea, 14, 199-204.
13 H. Lee, J. S. Kim, M. S. O & H. S. Kim. (2012). A Study on Improvements of Envelope system for The Energy Saving in Curtain Wall Office Buildings. Korean Institute of Architectural Sustainable Environment and Building Systems, 6, 106-113.
14 Y. S. Yoon, W. K. Choi & M. H. Sim. (2013). A Study on the Characteristics of the Energy Performance in Curtain Wall Building - Focused on the Glazing Type, Window to Wall Ratio and Internal Gains. Journal of the Architectural Institute of Korea, 29, 255-263. DOI : 10.5659/JAIK_PD.2013.29.7.255
15 H. K. Chung, K. S. Chung, Y. J. Lee, S. C. Sin & Y. I. Kim. (2012). A Study on Analysis Method for Performance Evaluation of Double-leaf facade of Office Building. The Korea Society for Energy Engineering, 21(2), 168-178.
16 K. Harby, D. R. Gebaly, N. S. Koura & M. S. Hassan. (2016). Performance improvement of vapor compression cooling systems using evaporative condenser: An overview. Renewable and Sustainable Energy Reviews, 58, 347-360. DOI : 10.1016/j.rser.2015.12.313   DOI
17 S. G. Han. (2006). The Effect of the restored Choenggye stream on heat island intensity and building cooling load in the surrounding area. Master's Thesis. University of Seoul. Seoul.
18 K. N. Kang, K. H. Lee & Y. J. Choi. (2010). The Analysis of Energy-saving Effect by Application of Double skin Facaded in Standard Office building. Proceedings of the Journal of the Korean Solar Energy Society Conference, Korea, 275-280.
19 S. Y. Lee, J. S. Kang & K. S. Kim. (2010). Energy Performance Evaluation of a Double-skin Facade with a Venetian Blind in Residential Buildings. Journal of the Korean Solar Energy Society, 30, 1-9.
20 H. J. Lee, J. S. Han, Y. K. Jeong, I. W. Lee & S. H. Lee. (2012). A Technology of Context-aware based Building Management for Energy Efficiency. Journal of Convergence Society for SMB, 2(1), 69-75.
21 S. M. Kuehni, E. Bou-Zeid, C. Webb & N. Shokri. (2016). Roof cooling by direct evaporation from a porous roof layer. Energy and Buildings, 127(1), 521-528.   DOI
22 K. U. Kwon. (2017). Evaluation of the thermal environmental condition for green building through empirical analysis on environmental performance. Doctoral dissertation. Konkuk University, Chungju.
23 Y. S. Choi. (1999). Study on the building cooling Load Reduction by using Evaporative Cooling. Master's Thesis. Konkuk University, Seoul.
24 N. E. Lee, H. S. Han, B. L. Ahn, H. G. Jeong & C. Y. Jang. (2013). A Study on Cooling Energy Saving Measures using Simulation and Metered Data of Existing Building. Proceedings of the Architectural Institute of Korea Conferences, 29(4), 235-242.
25 H. K. Kim, K. H. An & Y. S. Choi. (2011). LCC Analysis for Optimized Application of Renewable Energy of Eco-friendly School. Journal of the Architectural Institute of Korea, 27(11), 83-90.
26 D. K. Kim & C. S. Park. (2010). Comparison of an EnergyPlus double-skin simulation results with measurement. Proceedings of the Korean Institute of Architectural Sustainable Environment and Building Systems, Korea, 2010(3), 123-127.
27 W. J. Suh & C. S. Park. (2012). Issues and Limitations on the Use of a Whole Building Simulation Tool for Energy Diagnosis of a Real-life Building. Proceedings of the Architectural Institute of Korea Conferences, Korea, 28(1), 273-283.
28 J. D. Choi & G. Y. Yun. (2011). Differences in Results between Two Building Energy Simulation Programs based on EnergyPlus. Proceedings of the Architectural Institute of Korea Conferences, Korea, 31(2), 371-372.
29 J. W. Sin. (2008). A Study on the Variations of Heating Energy Consumption due to the Solar shading by the Adjacent Building. Master's Thesis. Kyungwon University, Gyeonggi-do.
30 K. C. Yoon, J. U. Jeon & K. S. Kim. (2011). Analysis on the Impact of Load Factors in Building Energy Simulation Affecting Building Energy Consumption. Journal of the Korea institute of ecological architecture and environment, 11(4), 71-78.