• Title/Summary/Keyword: Reduction Countermeasure

Search Result 156, Processing Time 0.026 seconds

Vibration Reduction Method for Discharge Line of Moisture Separator Reheater (습분분리재열기 배수관 진동저감방안)

  • 이준신;손석만;김태룡
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.688-694
    • /
    • 2001
  • The 84m discharge line of moisture separator reheater(MSR) in Kori-2 had been suffered by excessive vibration from the beginning of power generation. In 1993, a complementary measure was taken to reduce the vibration level by adding several supports in the MSR pipeline. However, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of MSR pipeline and the countermeasure for abnormal vibration was investigated. Among the several vibration reduction methods, piping layout change by smoothing the pipeline was applied to the MSR pipeline in Kori-2. Applying the countermeasure, the vibration level was found to dramatically reduce from 17cm/sec to l.0cm/sec at the full-power operation condition.

  • PDF

A Research on Process of Estimation about Frequency and Loss of Risk by distribution of Probability (확률분포에 의한 리스크 빈도수와 손실규모 추정 프로세스 연구)

  • Lee, Young-Jai;Lee, Seong-Il
    • Journal of Information Technology Applications and Management
    • /
    • v.15 no.2
    • /
    • pp.67-82
    • /
    • 2008
  • Risk that breed large size disaster is happening variously for cause at social. natural a management. Incidence and damage scale are trend that increase rapidly than past. In these circumstance, to keep operational continuity of organization, area, society, risk management action that establish systematic counter measure estimating and analyze occurrence possibility and expectation damage of risk is essential indispensable issue and the best countermeasure. Risk management action does by main purpose establish optimum disaster reduction countermeasure. To deduce various countermeasure, process that estimate and analyze occurrence possibility and expectation damage of risk is essential indispensable issue. Therefore, this paper studies process design that can presume risk occurrence frequency and damage scale through distribution of probability.

  • PDF

Parameter Estimation of Linear-FM with Modified sMLE for Radar Signal Active Cancelation Application

  • Choi, Seungkyu;Lee, Chungyong
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.6
    • /
    • pp.372-381
    • /
    • 2014
  • This study examined a radar signal active cancelation technique, which is a theoretical way of achieving stealth by employing a baseband process that involves sampling the incoming hostile radar signal, analyzing its characteristics, and generating countermeasure signals to cancel out the linear-FM signal of the hostile radar signal reflected from the airborne target. To successfully perform an active cancelation, the effects of errors in the countermeasure signal were first analyzed. To generate the countermeasure signal that requires very fast and accurate processing, the down-sampling technique with the suboptimal maximum likelihood estimation (sMLE) scheme was proposed to improve the speed of the estimation process while preserving the estimation accuracy. The simulation results showed that the proposed down-sampling technique using a 2048 FFT size yields substantial power reduction despite its small FFT size and exhibits similar performance to the sMLE scheme using the 32768 FFT size.

A Study on Application of Dimethoxy Methane and EGR Method for Simultaneous Reduction of Smoke and NOx Emission (매연과 NOx의 동기저감을 위한 Dimethoxy Methane과 EGR방법의 적용에 관한 연구)

  • Choi, Seung-Hun;Oh, Young-Taig;Hwang, Yun-Taig;Song, Ki-Hong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.448-453
    • /
    • 2003
  • In this study, the effects of oxygen component in fuel and exhaust gas recirculation(EGR) method on the exhaust emissions has been investigated for a D.I. diesel engine. It was tested to estimate change of exhaust emission characteristics for the commercial diesel fuel and oxygenate blended fuel which has five kinds of blending ratio. Dimethoxy methane(DMM) contains oxygen component 42.5% in itself. and it is a kind of effective oxygenated fuel for reduction of smoke emission. It was affirmed that smoke emission was decreased with increasing of DMM blending ratio. But, NOx emission was increased compared with commercial diesel fuel. It was needed a NOx reduction countermeasure that EGR method was used as a countermeasure for NOx reduction. It was found that simultaneous reduction of smoke and NOx emission was achieved with DMM blended fuel and cooled EGR method($10{\sim}15%$).

  • PDF

Numerical Analysis on Effective Countermeasure for Ground Subsidence due to Mining Hazard (광해로 인한 지반침하의 효율적인 보강방안에 관한 수치해석)

  • Hong, Won-Pyo;Lee, Jae-Ho;Hur, Se-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.4
    • /
    • pp.7-13
    • /
    • 2007
  • When the structure such as roadway, railway are constructed on abandoned coal mine area, the countermeasure to prevent settlements is necessary. In this study, numerical analyses are performed to evaluate the effect of the various countermeasures. As a results, the method which is filling the coal mine is more effective than that of reinforcing the ground above the coal mine. The ground settlement decreases hyperbolically with increasing the filling ratio of the coal mine. Also, the relationship between the filling ratio and the settlement reduction ratio is discussed precisely.

  • PDF

A Study on the Evaluation for Reduction Effect of Hydraulic Turbine Dynamo Noise after Establishment of Soundproof Measure (방음대책 수립 후 수차발전기 소음의 저감효과 평가에 관한 연구)

  • Yun, Jae-Hyun;Ju, Duck-Hoon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.133-137
    • /
    • 2007
  • As the waterpower generation plant, the subject of this Study, is a facility that produces plenty of electricity corresponds to $196{\sim}240GWh$ annually, and in its generation process it creates a loud noise when the turbine related to the hydraulic turbine dynamo revolves, and since such loud noise must be transmitted to the dynamo room and amplified, it is effecting a lot of influences to the adjacent office and space. In such viewpoint, this Research, based on the soundproof measure presented at the preceding research, has attempted to evaluate about the effect of noise-reduction countermeasure against the hydraulic turbine dynamo using Auralizational Technique through Psycho-Acoustics Experiment. It deems that such result could be applied hereafter as the useful material when setting up a soundproof countermeasure for the hydraulic turbine dynamo room in dam.

  • PDF

Analysis and Countermeasure for Shock-proof Performance of Laptop Computers (노트북 컴퓨터의 충격성능 분석 및 대책)

  • 임경화;윤영한;안채헌;김진규;이승은
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.490-495
    • /
    • 2001
  • This paper deals with an analysis and countermeasure for improving the shock performance of laptop computers. The shock analysis is carried out by using the commercial program of LS-DYNA3D. Also the analysis is verified by the measurements from modal tests and shock tests. The available countermeasures are investigated theoretically and experimentally to find the effective methods of reducing the shock acceleration on hard disk driver during one side fall test. The hard disk drive is the most sensitive part in a laptop computer. This research shows the effects of the spring constant of rubber pad, the reinforcement of mechanical parts and the location of a hard disk driver, on the shock reduction.

  • PDF

A Case Study on Noise Effect Assessment and Countermeasure by Emergency Generators installed in an Exterior and interior Architecture (건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구)

  • Yun, Dae-Jin;Choi, Jae-Sung;Kim, Chang-Yeol;Hong, Chang-Wan;Kim, Han-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.88-93
    • /
    • 2012
  • Recently data centers are being established or expanded according to IT industry development. A data center must be to install emergency generator. In case of the data center located the densely populated urban area, the operating noise of an emergency generator can be the cause of complains. In this case, in order to establish an effective and economical measure and quantitative and thorough review is needed by noise & vibration specialists. To achieve this, in this study, it is suggested noise reduction measure using noise measurement data and 3D noise analysis method.

  • PDF

A Case Study on Noise Impact Assessments and Countermeasures for Emergency Generators of the Data Center Building (건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구)

  • Yun, Dae-Jin;Choi, Jae-Sung;Kim, Chang-Yeol;Kim, Han-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.932-939
    • /
    • 2012
  • Recently, data centers are being established because IT and telecommunication industries are growing. The data centers have to install emergency generators to prevent unexpected shutdown of the electrical power supply. When the data centers are located in the densely populated urban area, the operating noise of the emergency generators can be a cause of people's complaints. In this case, it is necessary to establish effective countermeasure by noise & vibration specialists. To achieve this, noise reduction measure using noise measurement data and 3D noise analysis method have been employed in this study.

The Prediction of Vibration Reduction due to Vibration Isolating Countermeasure at Railway Station (역사의 방진대책에 따른 진동 저감 예측)

  • Lee, Tae-Keun;Park, Won-Gi;Kim, Byoung-Sam
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.11-16
    • /
    • 2011
  • When the trains are passed the station, a serious force is applied to ground and the caused vibration is propagated to the area of the station by the ground and rocks. The caused vibration brings about the operation interruption of the equipment which is sensitive to the vibration, or will bring about the structural damage of the station. In this study, to investigate the vibrational evaluation of railway station by the train service, the vibration simulation was performed and analyzed the effect of the vibration isolating countermeasure. From the vibration measurement, all trains that passed through the station exceeded the vibration criteria. Therefore, the vibration isolating countermeasure was established and the vibration simulation was performed.