Development of infiltration facility by utilizing tree box for urban storm water runoff reduction (도시지역 우수유출 저감을 위한 식재박스형 침투시설의 개발)

  • Joo, Jin-Gul;Cho, Hye-Jin;Lee, Yu-Hwa;Kim, Lee-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5330-5336
    • /
    • 2011
  • It becomes more and more important to develop various infiltration facilities for healthy water cycle and reduction of urban storm water runoff. In this study, a infiltration facility by utilizing tree box was developed. The developed facility is capable of reducing storm water road runoff, improving urban water cycle, and performing other sustainable and environmental functions. Because the facility can be manufactured to a smaller size than an existing runoff reduction facility, it can be installed at various road types of not only existing urban areas, but new developed areas. If the facility is applied to four-lane roadways, it is expected to reduce 65% of rainfall runoff discharge. Urban flood control improvement can be accomplished by a wide application of the developed technique.

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Real-time large-scale hybrid testing for seismic performance evaluation of smart structures

  • Mercan, Oya;Ricles, James;Sause, Richard;Marullo, Thomas
    • Smart Structures and Systems
    • /
    • v.4 no.5
    • /
    • pp.667-684
    • /
    • 2008
  • Numerous devices exist for reducing or eliminating seismic damage to structures. These include passive dampers, semi-active dampers, and active control devices. The performance of structural systems with these devices has often been evaluated using numerical simulations. Experiments on structural systems with these devices, particularly at large-scale, are lacking. This paper describes a real-time hybrid testing facility that has been developed at the Lehigh University NEES Equipment Site. The facility enables real-time large-scale experiments to be performed on structural systems with rate-dependent devices, thereby permitting a more complete evaluation of the seismic performance of the devices and their effectiveness in seismic hazard reduction. The hardware and integrated control architecture for hybrid testing developed at the facility are presented. An application involving the use of passive elastomeric dampers in a three story moment resisting frame subjected to earthquake ground motions is presented. The experiment focused on a test structure consisting of the damper and diagonal bracing, which was coupled to a nonlinear analytical model of the remaining part of the structure (i.e., the moment resisting frame). A tracking indictor is used to track the actuator ability to achieve the command displacement during a test, enabling the quality of the test results to be assessed. An extension of the testbed to the real-time hybrid testing of smart structures with semi-active dampers is described.

Simulation Analysis for Multiple-Server Queueing Model with Advertising and Balking (선전과 이탈이 있는 복수 서비스 대기행렬모형에 대한 시뮬레이션 분석)

  • 권치명;김성연;정문상;황성원
    • Journal of the Korea Society for Simulation
    • /
    • v.13 no.1
    • /
    • pp.41-50
    • /
    • 2004
  • The purpose of this paper is to analyse the manager's policy to maximize the profit in a multiple-server queueing facility with a limited queue capacity. We assume that the level of advertizing effects on the arrival rate of customers to the facility. The model without ‘word of mouth effect’ is assumed that the arrival rate is independent on the qualify of service level. We estimate the service quality by the balking rate of customers from system. We extend this to the model with ‘word of mouth effect’. To achieve the maximum profit, the most important factor is the considerably high utilization of facility for both models. Given service rate, we should maintain an effective arrival rate to some extent. To this end, among the available options, an increase of advertizing effort is more desirable than reducing the fee if the service value of customers remains unchanged. We also investigate whether the variability of service time has a significant impact on determining the optimal policy. The cost of service variability is not so expensive as that in a single server model due to the reduced variability of service times in a multiple-server model.

  • PDF

The Behavior of Effluent Discharged from the Confined Dumping Facility (제한투기시설에서 배출되는 여수의 거동)

  • 정대득;이중우
    • Journal of Korean Port Research
    • /
    • v.14 no.4
    • /
    • pp.429-439
    • /
    • 2000
  • The primary purpose of dredging work is to maintain navigational readiness and to increase environmental amenity. Therefore the dredging project, which is composed of excavating, removing, transporting and storing or dumping dredged material, must be carefully managed to insure that dredging works are completed in a cost-effective and environmentally safe method. The most important point in dumping operations is evaluating and decreasing the impacts of dumping works at the dumping area. One of the most effective method for this purpose is using the schematic process composed of the sophisticate plan, precise work and predicting/reducing the impacts based on an numerical model being closely linked with field observation. In this study, a numerical model is used to predict the spatial transport and fate of the effluent discharged from the confined dumping facility(CDF) located at a coastal area. To achive this purpose, numerical models were used for reappearing the tidal current of concerned area. These models were then applied to Mokpo harbpr where capital dredging and maintenance dredging are being conducted simultaneously and the CDF is under construction. In series of model case study, we found that the effluent discharged from CDF was governed by the receiving water condition and outfall geometry, so that limit of near-field was 14∼500 meter down stream and 4∼150 meter in transverse direction. dilution ranged from 1.1 to 8.2 on the cases. Long-term diffusion characteristics was governed by the dilution rate during near-field behavior, ambient conditions and CDF operation modes.

  • PDF

A Study on Development of Crash Cushion (도로 충격흡수시설의 개발에 관한 연구)

  • Choi, Ki-Jun;Kwon, Yong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.7-12
    • /
    • 2011
  • The crash cushion has drawn a great attention because of its versatility, efficiency and simplicity in reducing the mortality and damages from traffic accidents. However, the existing cushion systems are high priced or have limited functions. The purpose of the study was to devise an improved crash cushion which can offer higher safety compared to the available ones at present. In addition, the conformity of the cushion with the facility standards was assessed through computer simulation for collision with vehicles. The novel cushion system adopts the used tires as shock absorber, which can not only secure cushioning effect but also reduce the production cost. Moreover, it is highly durable and easy to maintain and repair the damaged parts. According to the simulation using BARRIER VII program, the novel cushion system showed PHD of 17.4 g and 10.1 g for a frontal collision and a side collision, respectively. Based on the results, it could be concluded that the novel cushion system met the test standards in the guideline for road safety facility installation and management.

The Effect of Job Instability and Job Stress on Turnover Intention in the COVID-19 Situation: Focused on the Moderating Effect of Sports Facility Workers' Perceived Organizational Support (COVID-19 상황에서 직무불안정성, 직무스트레스가 이직의도에 미치는 영향: 체육시설 종사자의 조직지원인식 조절효과를 중심으로)

  • Choi, Seung Kook;Noh, Yonghwi
    • Journal of Korean Society for Quality Management
    • /
    • v.49 no.2
    • /
    • pp.183-200
    • /
    • 2021
  • Purpose: This study is to investigate the effects of job instability and job stress on the turnover intention of sports facility workers in the COVID-19 situation, considering the moderating effects of perceived organizational support. Methods: This study surveyed service workers working at public sports facilities in Seoul, Gyeonggi Province and North Chungcheong Province, South Korea. The multi-regression and hierarchical regression analysis were employed to analyze the collected data. Results: The results indicate that all of the factors constituting job instability (organizational, job, and personal factors) had a significant influence on the factors constituting job stress (job characteristic, roll-related, and human relationship factors), except for only the relationship between organizational factor and rol-related factor. Job characteristic and roll-related factors constituting job stress significantly affected turnover intention of sports facility workers. Also, it was found that the perceived organizational support moderated the relationship between job characteristic factors of job stress and turnover intention. Conclusion: Although the COVID-19 created an environment with very high job instability, the negative impacts of job instability and job stress can be minimized through consideration and support for service workers of the organization, reducing turnover intention.

A Study on the Developing Process and Future Trend in the U. S. Health Care Facilities (미국 의료시설의 발전과정과 최근 동향에 관한 연구)

  • Choi, Kwang-Seok;Park, Jae-Seung;Mann, George J.;Kim, Kwang-Moon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.5 no.8
    • /
    • pp.7-14
    • /
    • 1999
  • Current Korean healthcare facilities face on a difficult period as much as financial difficulty in Korean economy. Most of all the hospitals have difficulty in minus profit margin and hospital investments are also reducing rapidly. Probably, these seem to set in the period of re-organizing its structures and enhancing productivity from the rapidly growing period, which was to concentrate its resources and prefer large scaled structures. Analyzing the developing process and future trend in the U. S. health care facilities, already experienced in financial difficulty of current Korean health care facility in 70s thru. 80s, this paper is to present directions in future Korean health care policy and healthcare facility planning.

  • PDF

Reducing Effect of Traffic Noise Soundproof Facilities (방음시설의 소음저감효과에 관한 연구)

  • Jeon, Gi-Seong;Park, Young-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • In order to propose the design and installation information of vegetation belt, field investigation were carried out in the noise pollution control facilities of highway and the streets of a city for two years(1998~1999), and field tests were performed to analyze the noise attenuation effect of them. The noise pollution control facilities were generally classified into three types (noise barrier and vegetation belt type, mounding and vegetation belt type, vegetation belt type only). Most soundproof facilities were proved the noise reduction effects. But according to width, height, structure, auditory distance and planting forms of them, difference of noise reduction effects were investigated. The soundproof facility was suitable the mounding and vegetation belt type in the consideration of road environment, and the installation standard of vegetation was estimated that the width of vegetation was at least 20m and the length of that was 2 times in the distance from noise source.

  • PDF