• Title/Summary/Keyword: Reduced field-of-view

Search Result 92, Processing Time 0.025 seconds

The design of the POCSAG decoder using FPGA (FPGA를 이용한 POCSAG 복호기의 설계)

  • Lim, Jae-Young;Kim, Geon;Kim, Young-Jin;Kim, Ho-Young;Cho, Joong-hwee
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.7
    • /
    • pp.269-277
    • /
    • 1996
  • This paper has been presented a design of a POCSAG decoder in RT-level VHDL and implemented in a FPGA chip, and tested. In a single clock of 76.8KHz, the decoder receives all the data of the rate of 512/1200/2400bps and has maximum 2-own frames for service enhancement. To improve decoder performance, the decoder uses a preamble detection cosidering 9% frequency tolerance, a SCW detction and a ICW detection at each 4 bit. The decoder also corrects a address data and a message data up to 2 bits and proposes the PF (preamble frequency) error for saving battery. The decoder increases a battery life owing to turn off RF circuits when the preamble signal is detected with nises. The chip has been designed in RT-level VHdL, synthesized into logic gates using power view$^{TM}$ of viewlogic software. The chip has been implemented in an ALTERA EPF81188GC232-3 FPGA chip with 98% usability, and fully tested in shield room and field room. The chip has been proved that the wrong detection numbers of preamble of noises are significantly reduced in the pager system using PDI 2400 through the real field test. The receiving performance is improved by 20% of aaverage, compared with other existing systems.

  • PDF

The Efficacy of Biofeedback in Reducing Cybersickness in Virtual Navigation (생체신호 피드백을 적용한 가상 주행환경에서 사이버멀미 감소 효과)

  • 김영윤;김은남;정찬용;고희동;김현택
    • Science of Emotion and Sensibility
    • /
    • v.5 no.2
    • /
    • pp.29-34
    • /
    • 2002
  • Our previous studies investigated that narrow field of view (FOV : 50˚) and slow navigation speed decreased the frequency of occurrence and severity of cybersickness during immersion in the virtual reality (VR). It would cause a significant reduction of cybersickness if it were provided cybersickness alleviating virtual environment (CAVE) using biofeedback method whenever subject underwent physiological agitation. For verifying the hypothesis, we constructed a real-time cybersickness detection and feedback system with artificial neural network whose inputs are electrophysiological parameters of blood pulse volume, skin conductance, eye blink, skin temperature, heart period, and EEG. The system temporary provided narrow FOV and decreased speed of navigation as feedback outputs whenever physiological measures signal the occurrence of cybersickness. We examined the frequency and severity of cybersickness from simulator sickness questionnaires and self-report in 36 subjects. All subjects experienced VR two times in CAVE and non-CAVE condition at one-month intervals. The frequency and severity of cybersickness were significantly reduced in CAVE than non-CAVE condition. Virtual environment of narrow FOV and slow navigation provided by electrophysiological features based artificial neural network caused a significant reduction of cybersickness symptoms. These results showed that efficiency of a cybersickness detection system we developed was relatively high and subjects expressed more comfortable in the virtual navigation environment.

  • PDF

The Detailed Design of the NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Park, Sung-Joon;Moon, Bongkon;Lee, Dae-Hee;Park, Won-Kee;Lee, Duk-Hang;Ko, Kyeongyeon;Pyo, Jeonghyun;Kim, Il-Joong;Park, Youngsik;Nam, Ukwon;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.39.3-40
    • /
    • 2015
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) onboard NEXTSat-1 is the near-infrared instrument optimized to the first small satellite of NEXTSat series. The capability of both imaging and low spectral resolution spectroscopy in the near-infrared range is a unique function of the NISS. The major scientific mission is to study the cosmic star formation history in local and distant universe. For those purposes, the main targets are nearby galaxies, galaxy clusters, star-forming regions and low background regions. The off-axis optical design of the NISS with two linear variable filters is optimized to have a wide field of view ($2deg.{\times}2deg.$) as well as the wide wavelength range from 0.95 to $3.8{\mu}m$. The mechanical structure is considered to endure the launching condition as well as the space environment. The dewar inside the telescope is designed to operate the infrared detector at 80K stage. From the thermal analysis, we confirmed that the telescope and the dewar can be cooled down to around 200K and 80K, respectively in order to reduce the large amount of thermal noise. The stray light analysis is shown that a light outside a field of view can be reduced below 1%. After the fabrications of the parts of engineering qualification model (EQM), the NSS EQM was successfully assembled and integrated into the satellite. To verify operations of the satellite in space, the space environment tests such as the vibration, shock and thermal-vacuum test were performed. Here, we report the results of the critical design review for the NISS.

  • PDF

The Influences of Deteriorated Visuo-spatial Attention Allocation Ability Caused by Aging on Emotional Perception Bias (노화에 의해 저하된 시공간 주의배분능력이 정서지각 편향성에 미치는 영향)

  • Kim, Sang-Yub;Jung, Jae-Bum;Nam, Ki-Chun
    • Science of Emotion and Sensibility
    • /
    • v.23 no.4
    • /
    • pp.3-20
    • /
    • 2020
  • The purpose of this study was to investigate the effect of aging on visuo-spatial attention allocation ability and emotional perception bias. We used the useful field of view (UFOV) task to measure the visuo-spatial attention allocation ability and the emotional perception task to measure positive and negative emotional perception bias. A total of 48 participants took part in this study with 23 participants in the senior group and 25 in the junior group. The senior group showed slower response time and lower accuracy than the junior group in the UFOV task, indicating that the senior group had lower visuo-spatial attention allocation ability than the junior group. In the emotional perception task, the senior group showed both positive and negative emotional perception bias more than the junior group. The correlation analysis showed that the negative emotional perception bias for accuracy in the emotional perception task showed a positive correlation with the response time to the stimuli presented in the visual angle 30° in the UFOV task (r=.289). In addition, positive emotional perception bias for the accuracy in the emotional perception task showed a positive correlation with the accuracy of the stimuli presented in the visual angles 10°, 20°, and 30° in the UFOV task (r=.305, r=.322, and r=.299, respectively). However, it showed a negative correlation with the response time of the stimuli presented in the same location in the UFOV task (r=-.345, r=-.295, r=-.308). These results suggest that aging is associated with a decrease in the visuo-spatial attention allocation ability and perceptual bias toward positive and negative emotions. In addition, the positive and negative emotional perception biases associated with aging are potentially related to the reduced visuo-spatial attention allocation ability.

A Study on Transformation of iOS GUI Design in the view of Affordance (iOS GUI 디자인의 변화에 대한 어포던스 관점의 고찰)

  • Yang, Yun;Kim, Hyung Woo
    • Smart Media Journal
    • /
    • v.5 no.4
    • /
    • pp.96-102
    • /
    • 2016
  • The purpose of this study is to investigate the transformation of affordance in iOS GUI design and the relationship of affordances. We figured out variety kinds of Affordance concepts and choosed six Affordances(Visceral, Behavioral, Reflective, Explicit, Metaphorical, Pattern Affordance) Based on the previous studies. The result of investigating the transformation of iOS GUI design which based on the viewpoint of these 6 Affordance we have chosen is as follows. Firstly, the Visceral Affordance of iOS GUI design has already sufficiently become to the Reflective Affordance. So we can ignore or ellipsis the Visceral Affordance and the addition of specific Explicit Affordance can be possible. Secondly, due to the use experience of iOS, Behavioral Affordance and Pattern Affordance have already become to a kind of Reflective Affordance. Through this evolution, new kind of Pattern Affordance is formed. At the mean time, it also applied the basic field of Metaphorical Affordance. Thirdly, investigating the Flat Design of iOS based on the viewpoint of Affordance, we have figured out that Visceral Affordance has been reduced. So that the constrains of visual performance has also been reduced. This is the reason that there are more space remained in screen layout design, the color has become more natural and more Explicit Affordance has been provided, ect. Futhermore, in this thesis we have also figured out that there are some interactions and relationships between each Affordance. With the development of iOS, some Affordances have transformed to other Affordances. With the accumulation of use experience, Visceral Affordance has transformed to Reflective Affordance based on the field of Metaphorical Affordance. With the disappearance or reduction of Visceral Affordance, iOS provide Explicit Affordance instead. As a result of this kind of process, a new Pattern Affordance has been formed.

Improved Breast Irradiation Techniques Using Multistatic Fields or Three Dimensional Universal Compensators (Multistatic Field또는 3차원 공용보상체를 사용한 유방의 방사선 조사법의 평가)

  • Han Youngyih;Cho Jae Ho;Park Hee Chul;Chu Sung Sil;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Purpose : In order to improve dose homogeneity and to reduce acute toxicity in tangential whole breast radiotherapy, we evaluated two treatment techniques using multiple static fields or universal compensators. Materials and Methods : 1) Multistatic field technique : Using a three dimensional radiation treatment planning system, Adac Pinnacle 4.0, we accomplished a conventional wedged tangential plan. Examining the isodose distributions, a third field which blocked overdose regions was designed and an opposing field was created by using an automatic function of RTPS. Weighting of the beams was tuned until an ideal dose distribution was obtained. Another pair of beams were added when the dose homogeneity was not satisfactory. 2) Universal compensator technique : The breast shapes and sizes were obtained from the CT images of 20 patients who received whole breast radiation therapy at our institution. The data obtained were averaged and a pair of universal physical compensators were designed for the averaged data. DII (Dose Inhomogeneity Index : percentage volume of PTV outside $95\~105\%$ of the prescribed dose) $D_{max}$ (the maximum point dose in the PTV) and isodose distributions for each technique were compared. Results : The multistatic field technique was found to be superior to the conventional technique, reducing the mean value of DII by $14.6\%$ (p value<0.000) and the $D_{max}$ by $4.7\%$ (p value<0.000). The universal compensator was not significantly superior to the conventional technique since it decreased $D_{max}$ by $0.3\%$ (p value=0.867) and reduced DII by $3.7\%$ (p value=0.260). However, it decreased the value of DII by maximum $18\%$ when patients' breast shapes fitted in with the compensator geometry. Conclusion : The multistatic field technique is effective for improving dose homogeneity for whole breast radiation therapy and is applicable to all patients, whereas the use of universal compensators is effective only in patients whose breast shapes fit inwith the universal compensator geometry, and thus has limited applicability.

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.

Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging (소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발)

  • Park, Jeong-Jin;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

The behavior of concrete filled steel tubular columns infilled with high-strength geopolymer recycled aggregate concrete

  • Rajai Z. Al-Rousan;Haneen M. Sawalha
    • Steel and Composite Structures
    • /
    • v.51 no.6
    • /
    • pp.661-678
    • /
    • 2024
  • The utilization of geopolymer recycled aggregate concrete (GRAC) as the infilled core of the concrete-filled steel tubular (CFST) columns provides superior economic and environmental benefits. However, limited research exists within the field of geopolymer recycled aggregate concrete considered a green and sustainable material, in addition to the limitation of the design guidelines to predict the behavior of such an innovative new material combination. Moreover, the behavior of high-strength concrete is different from the normal-strength one, especially when there is another material of high-strength properties, such as the steel tube. This paper aims to investigate the behavior of the axially loaded square high-strength GRACFST columns through the nonlinear finite element analysis (NLFEA). A total of thirty-two specimens were simulated using ABAQUS/Standard software with three main variables: recycled aggregate replacement ratio (0, 30, and 50) %, width-to-thickness ratios (52.0, 32.0, 23.4, and 18.7), and length-to-width ratio (3, 5, 9, and 12). During the analysis, the response in terms of the axial load versus the longitudinal strain was recorded and plotted. In addition, various mechanical properties were calculated and analyzed. In view of the results, it has been demonstrated that the mechanical properties of high-strength GRACFST columns such as ultimate load-bearing capacity, compressive stiffness, energy absorption capacity, and ductility increase with the increase of the steel tube thickness owing to the improvement of the confinement effect of the steel tube. In contrast, the incorporation of the recycled aggregate adversely affected the mentioned properties except the ductility, while the increase of the recycled aggregate replacement ratio improved the column's ductility. Moreover, it has been found that the increase in the length-to-width ratio significantly reduced both the failure strain and the energy absorption capacity. Finally, the obtained NLFEA results of the ultimate load-bearing capacity were compared with the corresponding predicted capacities by numerous codes. It has been concluded that AISC, ACI, and EC give conservative predictions for the ultimate load-bearing capacity since the confinement effect was not considered by these codes.

Dual Doppler Wind Retrieval Using a Three-dimensional Variational Method (3차원 변분법을 사용한 이중 도플러 바람장 분석)

  • Lee, SeonYong;Choi, Young-Jean;Chan, Dong-Eon
    • Atmosphere
    • /
    • v.17 no.1
    • /
    • pp.69-86
    • /
    • 2007
  • The characteristics of the dual-Doppler wind retrieval method based on a three dimensional variational (3DVAR) conception were investigated from the following four points of view; the sensitivity of the number of iteration, the effect of the weak constraint term, the effect of the smoothness term, and the sensitivity of the error mixing ratio of the radial velocities. In the experiment, the radial velocities relative to the Gosan and Jindo radar sites of the Korea Meteorological Administration (KMA) were calculated from the forecasting of the WRF (Weather Research and Forecast; Skamarock, 2004) model at 1330 UTC 30 June 2006, which is the one and half hour forecast from the initial time, 1200 UTC on that day. The results showed that the retrieval performance of the horizontal wind field was robust, but that of the vertical wind was sensitive to the external conditions, such as iteration number and the on/off of the weak constraint term. The sensitivity of error mixing ratio was so large that even the horizontal wind retrieval efficiency was reduced a lot. But the sensitivity of the smooth term was not so large. When we applied this method to the real mesoscale convective system (MCS) between the Gosan and Jindo radar pair at 1430 UTC 30 June 2006, the wind structure of the convective cells in the MCS was consistently retrieved relative to the reflectivity factor structure. By comparing the vertical wind structure of this case with that of 10 minutes after, 1440 UTC 30 June 2006, we got the physical consistency of our method.