• 제목/요약/키워드: Reduced current harmonics

검색결과 91건 처리시간 0.033초

입력전류의 정현화에 의한 단상PFC정류회로의 토폴로지 (Topology of Single-Phase PFC Rectifier Circuit with Sinusoidal of Input Current)

  • 이상현;김영문;권순걸;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.290-293
    • /
    • 2002
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. However, most of these employ switching devices, such as FETs and the like. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor connection scheme using a LC resonant in commercial frequency without switching devices. In this method, It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and experimental implementations.

  • PDF

입력전류 파형 개선형 단상 정류기의 토폴로지 (Topology of input current waveform improvement type single-phase rectifier)

  • 이상현;박진민;문상필;서기영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.403-406
    • /
    • 2003
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. However, most of these employ switching devices, such as FET and the like. The absence of switching devices mattes systems more tolerant to over-load and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced The result are confirmed by the theoretical and experimental implementations.

  • PDF

전력변환장치의 직류 파형 개선을 통한 고조파 저감 (Harmonics reduction by accuracy of DC shaping of power converters)

  • 김종수;안재홍;김성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1131-1136
    • /
    • 2014
  • 현재 LNG 운반선, 쇄빙선 등의 특수선박과 해양플랜트에 설치되는 전력변환 장치에는 다이오드를 이용하는 정류기가 많이 사용된다. 하지만 정류에 의한 비선형 부하의 입력전류에 많은 고조파가 포함되어 공급 전압파형의 왜곡을 초래한다. 전압파형의 왜곡은 발전기, 변압기, 부하기기 등의 오동작과 전력품질을 저하시키게 된다. 본 논문에서는 정류기 사용시의 전류왜곡을 감소시키기 위해서 직류 파형 정형화 회로를 사용하여 개선함으로써 부하에 인가되는 교류 파형을 정확한 정현파로 만든다. 그 결과 전력계통의 전류와 전압 파형에 포함되는 고조파를 저감할 수 있으며 이를 시뮬레이션을 통해 입증한다.

고역률 제어를 위한 단산 전압원 PWM 컨버터에 관한 연구 (A study of Single-phase Voltage Source PWM Converter for High Power Factor)

  • 류성식;손진근;정을기;김형원;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.362-365
    • /
    • 1999
  • In this paper, the method of reducing harmonics and correcting of power factor in single PWM converter associated with diode rectifier and boos converter is studied. The ac-dc converter in which the harmonic distortion in the input current is reduced using a third harmonic injected PWM is proposed. A lower switching power loss and easy configuration o control circuit are obtained by adopting discontinuous current mode. Simulation and experimental results of ac-dc converter with 5[KHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

승강압초퍼와 부부공진 인버터를 이용한 계통연계형 태양광 발전시스템 (Utility interactive PV system using buck-boost chopper and partial resonant Inverter)

  • 고강훈;이현우;김영철;정명웅;홍두성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.278-281
    • /
    • 1999
  • In a utility interactive photovoltaic system, a PWM inverter is used for the connection between the photovoltaic arrays and the utility. The DC current becomes pulsated causes the distortion of the AC current waveform. This paper presents the reduced pulsation of DC input current by operating the inverter with buck-boost chopper in the discontinuous conduction mode. The DC current with contains harmonics component is analyzed by means of separating into two terms of a ripple component and a direct component. The constant DC current without pulsation is supplied from photovoltaic array to the inverter. The proposed inverter system provide a sinusoidal AC current for domestic loads and the utility line with unity power factor.

  • PDF

Bidirectional High-Frequency Link Inverter with Deadbeat Control

  • Salam, Zainal
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.726-735
    • /
    • 2009
  • This paper presents a Bidirectional High-Frequency Link (BHFL) inverter that utilizes the Deadbeat controller. The main features of this topology are the reduced size of the inverter and fewer power switches. On the secondary side of the transformer, the active rectifier employs only two power switches, thus reducing switching losses. Using this configuration, the inverter is capable of carrying a bidirectional power flow. The inverter is controlled by a Deadbeat controller, which consists of the inner current loop, outer voltage loop and a feedforward controller. Additional disturbance decoupling networks are employed to improve the system's robustness towards load variations. A 1-kVA prototype inverter has been constructed and the Deadbeat control algorithm is experimentally verified. The experimental results show that the inverter has high efficiency (91%) with low steady state output voltage total harmonics distortion (1.5%).

Random PWM 기법을 이용한 무정전 전원장치의 노이즈 저감에 관한 연구 (A study on the Noise Reduction of Uninterruptible Power Supply using Random PWM Method)

  • 엄태욱;이병순;이재학
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.100-105
    • /
    • 2014
  • In this paper, Uninterruptible Power Supply(UPS) Inverter system using Carrier Frequency Modulated PWM (CFM-PWM) is proposed to reduced harmonics and electromagnetic noise. Power conversion of UPS system is executed by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI which deteriorate the reliability of the UPS system. This Problems improved by Random PWM switching method. The simulation results of the proposed system was compared with the system using conventional method using Matlab/Simulink. The results show that the output voltage and current harmonics of the proposed UPS system significantly decreased and spread into wide band area by the proposed Carrier Frequency Modulated PWM(CFM-PWM) method based on the Space Vector Modulation.

고속전철 보조전원 장치용 PWM컨버터의 4병렬 운전에 관한 연구 (A Study on The 4-Parallel Operation of PWM Converter for High Speed Train Auxiliary Block)

  • 오근우;김연충;원충연;최종묵;기상우;배기훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1230-1232
    • /
    • 2000
  • To reduce harmonics in the AC line and achieve a unit power factor, A 4 paralled single phase PWM AC/DC converter has been proposed. In this paper, the coupling components are derived analytically from PWM converter input transformer model and control scheme to solve this problem is proposed. Unit power factor was obtained and the AC-side current harmonics were reduced. Simulation results show the usefulness of the proposed method and applicability to PWM converter in auxiliary block of high speed train.

  • PDF

역률개선과 고조파 저감을 위한 전류공진 승압형 AC-DC 컨버터의 특성 해석 (Analysis of Characteristics for Current Resonant type Boost AC-DC Converter for PFC and Reducing Harmonics)

  • 라병훈;송대현;서기영;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.341-344
    • /
    • 2001
  • In this paper, the characteristics of the proposed converter are show by simulation. As a result, the power factor is improved and the results show the usefulness of the proposed circuit. To improve the hard switching at turn-off of the basic circuit, the circuit using a current resonant switch is proposed. In the proposed circuit, THD of the input current is reduced to 1.8 of the basic circuit. The mechanism of the THD reduction is clarified. That is because the on period becomes shorter at the peak of the source voltage. Using the simulation, the characteristics of the output voltage, current flowing the switch, and THD of the input current are investigated by changing the resonant circuit parameters. Criteria for choosing resonant parameters of smaller THD are obtained.

  • PDF

A New Space Vector Random PWM Scheme for Induction Motor Drives

  • Kim Hoe-Geun;Na Seok-Hwan;Lim Young-Cheol;Jung Young-Gook
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.160-168
    • /
    • 2001
  • The RPWM (Random· Pulse Width Modulation) is a switching technique to spread the voltage and current harmonics over a wide frequency area. By using randomly changing switching frequency of the inverter, the power spectrum of the electromagnetic acoustic noise can be spread to the wide-band area. The wide­band noise is much more comfortable and less annoying than the narrow-band one. So, the RPWM has been attracting interest as an excellent method for the reduction of acoustic noise on the inverter drive system. In this paper a new RPPWM (Random Position Space Vector PWM) is proposed and implemented. Each of three phase pulses is located randomly in each switching interval. Along with the randomization of PWM pulses, the space vector modulation is also executed in the C167 micro-controller. The experimental results show that the voltage and current harmonics are spread to a wide band area and that the audible switching noise is reduced by the proposed RPPWM method.

  • PDF