• Title/Summary/Keyword: Recommended Substances

Search Result 92, Processing Time 0.03 seconds

Explosion Likelihood Investigation of Facility Using CVD Equipment Using SEMI S6 (SEMI S6를 적용한 CVD 설비의 폭발분위기 조성 가능성 분석)

  • Mi Jeong Lee;Dae Won Seo;Seong Hee Lee;Dong Geon Lee;Se Jong Bae;Jong-Bae Baek
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.62-67
    • /
    • 2023
  • Due to the prolonged impact of COVID-19, the demand for Information Technology (IT) products is increasing, and their production facilities are expanded. Consequently, the use of harmful and dangerous chemicals are increased, the risk of fire(s) and explosion(s) is also elevated. In order to mitigate these risks, the government sets standards, such as KS C IEC 60079-10-1, and manages explosion-prone hazardous facilities where flammable substances are manufactured, used, and handled. However, using the standards of KS, it is difficult to predict the actual possibility of an explosion in a facility, because ventilation (an important factor) is not considered when setting up a hazardous work environment. In this study, the SEMI S6, Tracer Gas Test was applied to the chemical vapor deposition (CVD) facility, a major part of the display industry, to evaluate ventilation performance and to confirm the possibility of creating a less explosive environment. Based on the results, it was confirmed that the ventilation performance in the assumed scenarios met the standards stipulated in SEMI S6, along with supporting the possibility of creating a less explosive working condition. Therefore, it is recommended to use the prediction tool using engineering techniques, as well as KS standards, in such hazardous environments to prevent accidents and/or reduce economic burden following accidents.

Detection and Measurement of Nuclear Medicine Workers' Internal Radioactive Contamination (핵의학과 종사자의 방사성동위원소 체내오염 측정)

  • Jeong, Gyu-Hwan;Kim, Yong-Jae;Jang, Jeong-Chan;Lee, Jai-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.123-131
    • /
    • 2009
  • Purpose: We tested a sample of nuclear medicine workers at Korean healthcare institutions for internal contamination with radioactive isotopes, measuring concentrations and evaluating doses of individual exposure. Materials and Methods: The detection and measurement was performed on urine samples collected from 25 nuclear medicine workers at three large hospitals located in Seoul. Urine samples were collected once a week, 100~200 mL samples were gathered up to 6~10 times weekly. A high-purity germanium detector was used to measure gamma radiations in urine samples for the presence of radioactive isotopes. Based on the detection results, we estimated the amounts of intake and committed effective doses using IMBA software. In cases where committed effective doses could not be adequately evaluated with IMBA software, we estimated individual committed effective doses for radionuclides with a very short half life such as $^{99m}Tc$ and $^{123}I$, using the methods recommended by International Atomic Energy Agency. Results: Radionuclides detected through the analysis of urine samples included $^{99m}Tc$, $^{123}I$, $^{131}I$ and $^{201}Tl$, as well as $^{18}F$, a nuclide used in Positron Emission Tomography examinations. The committed effective doses, calculated based on the radionuclide concentrations in urine samples, ranged from 0 to 5 mSv, but were, in the majority of cases, less than 1 mSv. The committed effective dose exceeded 1 mSv in three of the samples, and all three were workers directly handling radioactive sources. No nurses were found to have a committed effective dose in excess of 1 mSv. Conclusions: To improve the accuracy of results, it may be necessary to conduct a long-term study, performed over a time span wide enough to allow the clear determination of the influence of seasonal factors. A larger sample should also help increase the reliability of results. However, as most Korean nuclear medicine workers are currently not necessary to monitored routinely for internal contamination with radionuclides. Notwithstanding, a continuous effort is recommended to reduce any unnecessary exposure to radioactive substances, even if in inconsequential amounts, by regularly surveying workplace environments and frequently monitoring atmospheric concentrations of radionuclides.

  • PDF

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

Application of Westgard Multi-Rules for Improving Nuclear Medicine Blood Test Quality Control (핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용)

  • Jung, Heung-Soo;Bae, Jin-Soo;Shin, Yong-Hwan;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.115-118
    • /
    • 2012
  • Purpose: The Levey-Jennings chart controlled measurement values that deviated from the tolerance value (mean ${\pm}2SD$ or ${\pm}3SD$). On the other hand, the upgraded Westgard Multi-Rules are actively recommended as a more efficient, specialized form of hospital certification in relation to Internal Quality Control. To apply Westgard Multi-Rules in quality control, credible quality control substance and target value are required. However, as physical examinations commonly use quality control substances provided within the test kit, there are many difficulties presented in the calculation of target value in relation to frequent changes in concentration value and insufficient credibility of quality control substance. This study attempts to improve the professionalism and credibility of quality control by applying Westgard Multi-Rules and calculating credible target value by using a commercialized quality control substance. Materials and Methods : This study used Immunoassay Plus Control Level 1, 2, 3 of Company B as the quality control substance of Total T3, which is the thyroid test implemented at the relevant hospital. Target value was established as the mean value of 295 cases collected for 1 month, excluding values that deviated from ${\pm}2SD$. The hospital quality control calculation program was used to enter target value. 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T of Westgard Multi-Rules were applied in the Total T3 experiment, which was conducted 194 times for 20 days in August. Based on the applied rules, this study classified data into random error and systemic error for analysis. Results: Quality control substances 1, 2, and 3 were each established as 84.2 ng/$dl$, 156.7 ng/$dl$, 242.4 ng/$dl$ for target values of Total T3, with the standard deviation established as 11.22 ng/$dl$, 14.52 ng/$dl$, 14.52 ng/$dl$ respectively. According to error type analysis achieved after applying Westgard Multi-Rules based on established target values, the following results were obtained for Random error, 12s was analyzed 48 times, 13s was analyzed 13 times, R4s was analyzed 6 times, for Systemic error, 22s was analyzed 10 times, 41s was analyzed 11 times, 2 of 32s was analyzed 17 times, $10\bar{x}$ was analyzed 10 times, and 7T was not applied. For uncontrollable Random error types, the entire experimental process was rechecked and greater emphasis was placed on re-testing. For controllable Systemic error types, this study searched the cause of error, recorded the relevant cause in the action form and reported the information to the Internal Quality Control committee if necessary. Conclusions : This study applied Westgard Multi-Rules by using commercialized substance as quality control substance and establishing target values. In result, precise analysis of Random error and Systemic error was achieved through the analysis of 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T rules. Furthermore, ideal quality control was achieved through analysis conducted on all data presented within the range of ${\pm}3SD$. In this regard, it can be said that the quality control method formed based on the systematic application of Westgard Multi-Rules is more effective than the Levey-Jennings chart and can maximize error detection.

  • PDF

Effects of Feeding Eucommia ulmoides Leaves Substituted for Rice Straw on Growth Performance, Carcass Characteristics and Fatty Acid Composition of Muscle Tissues of Hanwoo Steers (볏짚을 두충잎으로 대체급여 시 거세한우의 생산성, 도체특성 및 육의 지방산 조성에 미치는 영향)

  • Kim, J.H.;Kim, Y.M.;Lee, M.D.;Shin, J.H.;Ko, Y.D.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.963-974
    • /
    • 2005
  • This study was conducted to examine the growth performance, carcass characteristics, physico-chemical properties and fatty acid composition of muscle tissues of Hanwoo steers when they were fed diets containing four levels of E. ulmoides leaves. Steers were allotted to one of four dietary treatments, which were designed to progressively substitute Eucommia ulmoides for 0, 3, 5 and 10% of the rice straw in the basal diet. Seventy two Hanwoo steers (321±13kg) were used. Average daily gain (0.81-0.86kg) and feed conversion (10.05-10.59) were not changed by feeding E. ulmoides leaves. Emission of fecal ammonia gas was decreased by increasing substitution levels of E. ulmoides leaves. Emission of ammonia gas in feces of steers were significantly (p<0.05) decreased in the 5% and 10% treatments at 40℃ compared with in control (30.6ppm) and 3% treatment (29.8ppm), respectively 20.3 and 21.6ppm. Back fat thickness was higher (p<0.05) in steers fed control diet (15.0mm) than 5 and 10% E. ulmoides diets (10.2 and 10.5mm respectively). The grade ‘A’ appearances of meat yield of steers were increased up to 20% by the 3% substitution of E. ulmoides leaves, and the grades ‘1+’ and ‘1’ appearances of meat quality were significantly improved (p<0.05) by the 5 and 10% Eucommia ulmoides feeding. There was no statistical difference in meat color of loin and top round among all treatments. It appeared that the 5% and 10% E. ulmoides leaves feeding affected (p<0.05) a increase in oleic acid concentration in loin and top round muscles. The concentration of serum cholesterol was lower (p<0.05) in steers fed 10% E. ulmoides (53.3mg/100g) than that of the other treatments (55.7-57.0mg/100g). The diarrhea incidence was about 20.26% in control, while it was lower (p<0.05) in the 5 and 10% E. ulmoides leaves treatments (10.4-12.5%) than control. There was no statistical difference in the occurrences of respiratory disease among all treatments. It is concluded that E. ulmoides leaves should be a prospective feed additive because it contains various functional substances. It is likely that air-dried E. ulmoides leaves can reduce the back fat thickness of Hanwoo steers and the occurrences of diarrhea. Therefore, the 5 and 10% substitution of E. ulmoides for roughage are highly recommended to be used in practice.

OECD High Production Volume Chemicals Program: Ecological Risk Assessment of Copper Cyanide (대량생산화학물질 초기위해성평가: 시안화구리의 초기 생태위해성평가)

  • Baek, Yong-Wook;Kim, Eun-Ju;Yoo, Sun-Kyoung;Ro, Hee-Young;Kim, Hyun-Mi;Eom, Ig-Chun;Kim, Pil-Je
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.3
    • /
    • pp.272-279
    • /
    • 2011
  • Copper cyanide is a chemical produced in large quantities with 2,500 tonnes being produced in 2006. It is mainly used for electroplating copper, particularly alkali-Cu plate and brass plating. The purpose of this study is to reassess the physicochemical properties and environmental fate of copper cyanide based on reliable data and and to conduct an ecotoxicity test according to the OECD test guidelines as an initial environmental risk assessment (need to state where this was done). Metal containing inorganic substances are not subject to degradation, biodegradation or hydrolysis. Aquatic toxicity tests of copper cyanide were conducted according to OECD test guideline 201, 202 and 203 for green algae, daphnia, and fish, respectively. The following acute toxicity test results were obtained for aquatic species: 0.089 mg $L^{-1}$ (Algae, 72 Hr-$EC_{50}$); 0.21 mg $L^{-1}$ (flea, 48 Hr-$LC_{50}$); 0.62 mg $L^{-1}$ (Fish, 96 Hr-$ErC_{50}$). The chemical possesses properties indicating a hazard for the aquatic environment (acute toxicity in fish, daphnia and algae below 1.0 mg $L^{-1}$). As a result of this study, copper cyanide has become a candidate for detailed risk assessment. Countries that produce this chemical in significant quantities are recommended to perform specific assessments.

Quality and Shelf-Life of Vacuum Packed RTE (Ready-To-Eat) Hamburg Steak Depending on the Oxygen Permeability of Packaging Material and the Storage Temperature (포장재의 산소투과도와 저장온도에 따른 즉석섭취형 햄버그스테이크의 품질 및 저장성)

  • Lim, Ji Hoon;Lee, Sung Ki;Chung, Seung Hee;Lee, Keun Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.22 no.3
    • /
    • pp.95-102
    • /
    • 2016
  • This study investigated the effects of the oxygen permeability of vacuum packaging film and the storage temperature on the quality and shelf life of Hamburg steaks during storage for 14 days. Control samples (C) were packaged in a polyamide/polyethylene (PA/PE) film and stored at $5^{\circ}C$. Treatment samples were either packaged in an ethylene vinyl alcohol/polyethylene (EVOH/PE) copolymer film and stored at $5^{\circ}C$ (T1), and in a PA/PE film and stored at $-18^{\circ}C$ (T2). The initial total plate count (TPC) was 3.6 log cfu/g. In T1 samples, TPC and Brochothrix thermosphacta counts were increased, similar to those in C samples, whereas Pseudomonas spp. counts were significantly lower than those in C samples during storage. Over the storage period, the volatile basic nitrogen values increased most rapidly in C samples, followed by T1 and then T2 samples. The values of thiobarbituric acid reactive substances steadily increased in all samples during storage. The colour parameters were not significantly different among the samples during storage. T1 samples maintained sensory qualities in flavour and off-odour parameters for two days longer than C samples did. At day 12, T2 samples were evaluated as being below the marketability score of 5.0 for texture. In conclusion, using high oxygen barrier films like EVOH/PE copolymer for packaging Hamburg steaks could extend the sensory qualities in view of flavour and off-odour during chilled storage. However, frozen storage at $-18^{\circ}C$ is recommended when the storage period is extended beyond 14 days at $5^{\circ}C$.

Changes of Antioxidant Effects According to Greening Period of Astragalus membranaceus var. membranaceus, Senna occidentalis, Dianthus longicalyx, and Plantago asiatica Sprout Vegetables (녹화 처리기간에 따른 황기, 석결명, 술패랭이꽃 및 질경이 새싹채소의 항산화 효과 변화)

  • Lee, Cheol-Hee;Shin, So-Lim;Kim, Na-Rae;Yoon, Sung-Eun;Kim, Su-In;Baek, Seol-Hee;Hwang, Ju-Kwang
    • Korean Journal of Plant Resources
    • /
    • v.22 no.4
    • /
    • pp.349-358
    • /
    • 2009
  • The potential use of 4 plant species, Astragalus membranaceus var. membranaceus, Senna occidentalis, Dianthus longicalyx and Plantago asiatica, as new sprout vegetables with high antioxidant function was examined in the present experiments. Seeds of above plants were allowed to germinate under light condition, and seedlings were maintained under dark condition for shoot growth in length for contain period of time. Then the seedlings were put under light for photosynthesis (greening treatment) for the period of 0${\sim}$3 days. Samples were collected to analyze the changes in antioxidant levels and activity, and it was observed that antioxidant substances were affected by greening treatments, depending on plant species. In A. membranaceus, the contents of total polyphenol was highest with no greening, total flavonoids with 3 days greening, DPPH radical scavenging effects with no greening, ABTS scavenging with 1 day greening, $Fe^{2+}$ chelating effects with no greening, and inhibitory activity against linoleic acid peroxidation with 3 day greening. In S. occidentalis, highest levels of antioxidant activity and radical scavenging effects were obtained by 2 day greening, $Fe^{2+}$ chelating effects by no greening and inhibitory activity against linoleic acid peroxidation by 1 day greening. In D. longicalyx, highest levels of antioxidant activity and $Fe^{2+}$ chelating effects were obtained by 2 day greening, $Fe^{2+}$ chelating effects by no greening and inhibitory activity against linoleic acid peroxidation by 1 day greening. In D. longicalyx, highest levels antioxidant activity and $Fe^{2+}$ chelating effects were observed with 3 day greening, and highest radical scavenging effects and inhibitory activity against linoleic acid peroxidation with no greening treatment. In P. asiatica, antioxidant activity and radicals scavenging effects were highest with 2 day greening, whereas highest chelating effects was obtained with no greening and highset inhibitory activity against linoleic acid peroxidation with 3 day greening. As the length of greening treatments influenced the antioxidant levels and function in plant species tested in this experiments, different culture methods are recommended for different plant species to get maximum health benefits out of sprout vegetables.

Comparison of Antioxidant Effects of Different Korean Pear Species (종에 따른 배나무 열매의 항산화 활성 비교)

  • Lee, Cheol-Hee;Shin, So-Lim;Kim, Na-Rae;Hwang, Ju-Kwang
    • Korean Journal of Plant Resources
    • /
    • v.24 no.2
    • /
    • pp.253-259
    • /
    • 2011
  • In this studies, contents and activities of antioxidative substances in the fruits of a pear cultivar and five Korean wild pear lines were investigated. The content of total phenolic compounds was highest with Pyrus pyrifolia var. culta "Shingo" (7.68 $mg{\cdot}g^{-1}$, D.W.) while total flavonoids was highest with P. ussuriensis var. acidula (5.66 $mg{\cdot}g^{-1}$, D.W.). The contents of total polyphenols and flavonoids varied according to plant species, but in general pyrifolia lines had higher total polyphenols than total flavonoids whereas in ussuriensis lines total flavonoid contents were higher than total polyphenols. The scavenging effects of DDPH radicals was highest with highest with P. ussuriensis var. seoulensis ($RC_{50}$=1.45 $mg{\cdot}mL^{-1}$) and that of ABTS radicals was highest with P. ussuriensis var. acidula ($RC_{50}$=0.69 $mg{\cdot}mL^{-1}$). A pear cultivar "Shingo" showed highest total polyphenol content, but scavenging activity of DDPH and ABTS radicals was lowest. The fruits of P. ussuriensis var. seoulensis contained low level of phenolic compounds, but their scavenging effects on two radicals was superior. Ferrous ion chelating effect was high in P. pyrifolia var. culta (98.93%), and in P. ussuriensis var. sinensis (68.71%), but two species had low scavenging activity. The content of phenolic compounds in wild pears was not always directly proportional to the radical scavenging activity. Neither radical scavenging activity was to ferrous ion chelating activity. In conclusion the fruits of P. ussuriensis var. acidula, P. ussuriensis var. seoulensis, and P. ussuriensis var. sinensis had great potential for the development of new antioxidative functional food because their antioxidative activity is higher or at least similar to P. pyrifolia var. culta. However, due to their different levels of antioxidative effects, the development of methods of using them jointly, not singly, to obtain maximum level of antioxidants is recommended.

Key Methodologies to Effective Site-specific Accessment in Contaminated Soils : A Review (오염토양의 효과적 현장조사에 대한 주요 방법론의 검토)

  • Chung, Doug-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.4
    • /
    • pp.383-397
    • /
    • 1999
  • For sites to be investigated, the results of such an investigation can be used in determining foals for cleanup, quantifying risks, determining acceptable and unacceptable risk, and developing cleanup plans t hat do not cause unnecessary delays in the redevelopment and reuse of the property. To do this, it is essential that an appropriately detailed study of the site be performed to identify the cause, nature, and extent of contamination and the possible threats to the environment or to any people living or working nearby through the analysis of samples of soil and soil gas, groundwater, surface water, and sediment. The migration pathways of contaminants also are examined during this phase. Key aspects of cost-effective site assessment to help standardize and accelerate the evaluation of contaminated soils at sites are to provide a simple step-by-step methodology for environmental science/engineering professionals to calculate risk-based, site-specific soil levels for contaminants in soil. Its use may significantly reduce the time it takes to complete soil investigations and cleanup actions at some sites, as well as improve the consistency of these actions across the nation. To achieve the effective site assessment, it requires the criteria for choosing the type of standard and setting the magnitude of the standard come from different sources, depending on many factors including the nature of the contamination. A general scheme for site-specific assessment consists of sequential Phase I, II, and III, which is defined by workplan and soil screening levels. Phase I are conducted to identify and confirm a site's recognized environmental conditions resulting from past actions. If a Phase 1 identifies potential hazardous substances, a Phase II is usually conducted to confirm the absence, or presence and extent, of contamination. Phase II involve the collection and analysis of samples. And Phase III is to remediate the contaminated soils determined by Phase I and Phase II. However, important factors in determining whether a assessment standard is site-specific and suitable are (1) the spatial extent of the sampling and the size of the sample area; (2) the number of samples taken: (3) the strategy of taking samples: and (4) the way the data are analyzed. Although selected methods are recommended, application of quantitative methods is directed by users having prior training or experience for the dynamic site investigation process.

  • PDF