Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground  

Kim, Won-Taek (Departments of Radiation Oncology, College of Medicine, Pusan National University)
Shin, Yong-Chul (Department of Occupational Health and Safety Engineering, Inje University)
Kang, Dong-Mug (Departments of Preventive Medicine, College of Medicine, Pusan National University)
Ki, Yong-Kan (Departments of Radiation Oncology, College of Medicine, Pusan National University)
Kim, Dong-Won (Departments of Radiation Oncology, College of Medicine, Pusan National University)
Kwon, Byung-Hyun (Departments of Radiation Oncology, College of Medicine, Pusan National University)
Publication Information
Radiation Oncology Journal / v.23, no.4, 2005 , pp. 243-252 More about this Journal
Abstract
Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.
Keywords
Indoor air qualify; Sick building syndrome; Radiation oncology; Underground;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Reynolds SJ, Black DW, Borin SS, et al. Indoor environmental quality in six commercial office building in the midwest United States. App Occ Env Hyg 2001;16:1065-1077   DOI   ScienceOn
2 Nordstrom K, Norback D, Akselsson R. Effect of air humidification on the sick building syndrome and perceived indoor air quality in hospitals: a four month longitudinal study. Occup Environ Med 1994;51:683-688   DOI   ScienceOn
3 Lee CM, Kim YS, No YM, Kim JC, Jeon HJ, Lee SD. Health risk assessment of exposure to indoor air pollutants in office building. J Korean Soc Occup Environ Hyg 2004;14: 251-263
4 Sisovic E, Fugas M, Sega K. Assessment of human inhalation exposure to polycyclic aromatic hydrocarbons. J Expo Anal Environ Epidemio 1996;6:439-447
5 Kim YS, Lee CM, Kim HT, Iida T. A survey of indoor and outdoor radon concentrations by alpha track detector in Korea. Kor J Env Hlth 2002;28:71-76
6 Boxer PA. Indoor air quality: a psychosocial perspective. J Occup Med 1990;32:425-428   DOI
7 Buemi M, Floccari F, Netto M, et al. Environmental air pollution in an intensive care unit for nephrology and dialysis. J Nephrol 2000;13:433-436
8 Molhave L. Indoor climate, air pollution, and human comfort. J Expo Anal Environ Epidemiol 1991;1:63-81   PUBMED
9 Daisey JM, Angell WJ, Apte MG. Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information. Indoor Air 2003;13:53-64   DOI   ScienceOn
10 Malkin R, Wilcox T, Sieber WK. The National Instiute for Occupational Safety and Health indoor environmental evaluation experience, part two: symptom prevalence. Appl Occup Environ Hyg 1996;11:540-545   DOI   ScienceOn
11 Roh YM, Lee CM, Kim SW, et al. A study on the characteristics of indoor air quality in office and subjective symptoms of office workers. J Korean Soc Occup Environ Hyg 2004;14: 270-282
12 Springston JP, Esposito WA, Cleversey KW. Baseline indoor air quality measurement collected from 136 metropolitan New York region commercial office building between 1997- 1999. Am Ind Hyg Associ J 2002;63:354-360   DOI   ScienceOn
13 Benesova V, Bencko V, Hoskins J. International conference on indoor environment quality in hospitals. Prague 10-11 October 2002. Cent Eur J Public Health 2003;11:115-116
14 Nordstrom K, Norback D, Akselsson R. Influence of indoor air quality and personal factors on the sick building syndrome (SBS) in Swedish geriatric hospitals. Occup Environ Med 1995; 52:170-176   DOI   ScienceOn
15 Clayton CA, Perritt RL, Pellizzari ED, et al. Particle total exposure assessment methodology (PTEAM) study: distributions of aerosol and elemental concentrations in personal, indoor and outdoor air samples in a Southern California community. J Expo Anal Environ Epidemio 1993;3:227-250