동물에서 자기 공명 영상 진단의 물리적 원리 (Physical Principles of Magnetic Resonance Imaging in Animal)

  • 김종규
    • 한국임상수의학회지
    • /
    • 제16권1호
    • /
    • pp.75-79
    • /
    • 1999
  • Magnetic resonance imaging (MRI) is an imaging technique used to produce high quality images of the inside of the animal body. MRI is based on the principles of nuclear magnetic resonance (NMR) and started out as a tomographic imaging technique, that is it produced an image of the NMR signal in a thin slice through the animal body. The animal body is primarily fat and water, Fat and water have many hydrogen atoms. Hydrogen nuclei have an NMR signal. For these reasons magnetic resonance imaging primarily images the NMR signal from the hydrogen nuclei. Hydrogen protons, within the body align with the magnetic field. By applying short radio frequency (RF) pulses to a specific anatomical slice, the protons in the slice absorb energy at this resonant frequency causing them to spin perpendicular to the magnetic field. As the protons relax back into alignment with the magnetic field, a signal is received by an RF coil that acts as an antennae. This signal is processed by a computer to produce diagnostic images of the anatomical area of interest.

  • PDF

자기유도를 이용한 조향각 센서의 특성 연구 (A Study on the Characteristics of Steering Angle Sensor using Magnetic Induction)

  • 김병우
    • 한국자동차공학회논문집
    • /
    • 제18권2호
    • /
    • pp.48-55
    • /
    • 2010
  • We have development the steering angle sensor using not only detecting parts but also integrating technique with semiconductors for automobile applications. The performance design and analysis of the steering angle sensor for intelligent vehicles is complicated due to variety of parameters. In this study, the performance characteristics of the angle sensor were analyzed using test rig. By means of magnetic induction technique, these new the steering angle sensors showed excellent magnetic characteristics. The detection range of steering angle sensor obtained was ${\pm}800^{\circ}$, the maximum non-linearity is 0.744% Full Span and the temperature range was $-40^{\circ}C{\sim}+125^{\circ}C$. With this conclusive, the inductive angle sensor was quite satisfactory for many applications in intelligent vehicles.

유도초음파를 이용한 대구경 배관 적용에 관한 연구 (Application of Thin-Walled Tubes Using Guided Wave)

  • 박상기;이영호
    • 동력기계공학회지
    • /
    • 제12권1호
    • /
    • pp.58-65
    • /
    • 2008
  • A method to test thin-walled tubes by guided ultrasonic wave is reported. The principle is that applicate two types of axially symmetric ultrasonic tube modes and "longitudinal" modes with particle displacement, which is coupled in axial and radial directions for transverse failures and torsional modes, oscillating in the circumferential direction only, for longitudinal failures. Both types of modes propagate along the tube in the axial direction. Therefore, a pulse-echo technique is possible. The pulses are excited and received at one end of the tube without contact electro-dynamic transducers. As soon as the tubes is put into a transducer coil at one end, the test of the whole tube can be accomplished in a few milliseconds. It is not necessary to rotate and transport the tubes during the test.

  • PDF

E-모빌리티 응용을 위한 6.78MHz 정전압 정전류 무선 충전기 (A 6.78 MHz Constant Current and Constant Voltage Wireless Charger for E-mobility Applications)

  • Tran, Manh Tuan;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.142-144
    • /
    • 2019
  • Nowadays, multi-MHz wireless power transfer (WPT) system has received a great concern of study due to its desirable characteristics such as user convenience, system compact and better safety as compared to the conventional DC-DC with cord. This paper presents a solution for WPT Lithium Batteries charger with Constant Current (CC) and Constant Voltage (CV) charging process. The proposed system consists of a high frequency class D power amplifier, a pair of PCB coil, transformable high-order resonant network and a full-bridge rectifier. The charger can be implemented CC /CV charging profile thanks to automatic reconfigurable resonant compensator. Therefore, the battery can be fully charged without the help of an additional DC/DC converter. The simulation and 50W-6.78-MHz hardware experimental results are presented to verify the feasibility of the proposed method and to evaluate the performance of the proposed wireless battery charger.

  • PDF

DC Superconducting fault current limiter characteristic test with a DC circuit breaker

  • So, Jooyeong;Choi, Kyeongdal;Lee, Ji-kwang;Kim, Woo-Seok
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권2호
    • /
    • pp.19-23
    • /
    • 2021
  • We have studied the breaking system that combines a resistive superconducting fault current limiter (SFCL) and a DC circuit breaker for DC fault current. To verify the design of the 15 kV DC SFCL, which was driven from the previous work, a 500 V DC system was built and a scale-down SFCL were manufactured. The manufactured SFCL module was designed as a bifilar coil which is a structure that minimizes inductive reactance. The manufactured SFCL module has been experiment to verify characteristics of the current-limiting performance in the DC 500 V system. Also, the manufactured FCL module was combined with the DC circuit breaker to be experimented to analyze the breaking performance. As a result of the experiment, when SFCL was combined to the DC circuit breaker, the energy dissipation received by the DC circuit breaker was reduced by up to 84% compared to when the DC circuit breaker operates alone. We are preparing methods and experiments for the optimal method for much higher performance as a future work.

Clopidogrel Response Variability in Unruptured Intracranial Aneurysm Patients Treated with Stent-Assisted Endovascular Coil Embolization : Is Follow-Up Clopidogrel Response Test Necessary?

  • Kim, Min Soo;Park, Eun Suk;Park, Jun Bum;Lyo, In Uk;Sim, Hong Bo;Kwon, Soon Chan
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권2호
    • /
    • pp.201-211
    • /
    • 2018
  • Objective : The purpose of this study was to analyze the variability of clopidogrel responses according to duration of a clopidogrel drug regimen after stent-assisted coil embolization (SAC), and to determine the correlation between the variability of clopidogrel responses and thromboembolic or hemorrhagic complications. Methods : A total of 47 patients who underwent SAC procedures to treat unruptured intracranial aneurysms were enrolled in the study. Preoperatively, patients received more than seven days of aspirin (100 mg) and clopidogrel (75 mg), daily. P2Y12 reaction unit (PRU) was checked with the VerifyNow test one day before the procedure (pre-PRU) and one month after the procedure (post-PRU). PRU variability was calculated as the difference between the initial response and the follow-up response. Patients were sorted into two groups based on their response to treatment : responsive and hypo-responsive. Results : PRU variability was significantly greater in the hypo-responsive group when compared to the responsive group (p=0.019). Pre-PRU and serum platelets counts were significantly correlated with PRU variation (p=0.005 and p=0.004, respectively). Although thromboembolic complication had no significant correlated factors, hemorrhagic complication was correlated with pre-PRU (p=0.033). Conclusion : In conclusion, variability of clopidogrel responses during clopidogrel medication was correlated to serum platelet counts and the initial clopidogrel response. Thromboembolic and hemorrhagic complications did not show correlation with the variability of clopidogrel response, or the clopidogrel response after one month of medication; however, hemorrhagic complication was associated with initial clopidogrel response. Therefore, it is recommended to test patients for an initial clopidogrel response only, as further tests would be insignificant.

Effects of surface-roughness and -oxidation of REBCO conductor on turn-to-turn contact resistance

  • Y.S., Chae;H.M., Kim;Y.S., Yoon;T.W., Kim;J.H., Kim;S.H., Lee
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권4호
    • /
    • pp.40-45
    • /
    • 2022
  • The electrical/thermal stabilities and magnetic field controllability of a no-insulation (NI) high-temperature superconducting magnet are characterized by contact resistance between turn-to-turn layers, and the contact resistance characteristics are determined by properties of conductor surface and winding tension. In order to accurately predict the electromagnetic characteristics of the NI coil in a design stage, it is necessary to control the contact resistance characteristics within the design target parameters. In this paper, the contact resistance and critical current characteristics of a rare-earth barium copper oxide (REBCO) conductor were measured to analyze the effects of surface treatment conditions (roughness and oxidation level) of the copper stabilizer layer in REBCO conductor. The test samples with different surface roughness and oxidation levels were fabricated and conductor surface analysis was performed using scanning electron microscope, alpha step surface profiler and energy dispersive X-ray spectroscopy. Moreover, the contact resistance and critical current characteristics of the samples were measured using the four-terminal method in a liquid nitrogen impregnated cooling environment. Compared with as-received REBCO conductor sample, the contact resistance values of the REBCO conductors, which were post-treated by the scratch and oxidation of the surface of the copper stabilizer layer, tended to increase, and the critical current values were decreased under certain roughness and oxidation conditions.

태양광 발전에 의한 비접촉 방식 저 전력 에너지 전송회로에 관한 연구 (A Study on Low Power Energy Transfer Circuits of the Non Contact Method by means of Solar Generation)

  • 황락훈;나승권;김종래;최기호;김진선
    • 한국항행학회논문지
    • /
    • 제18권1호
    • /
    • pp.35-43
    • /
    • 2014
  • 본 논문은 무선 전력 전송에 관한 이론을 토대로 송신부와 수신부의 두 개의 평면 코일 사이의 자기 유도 원리의 다양한 조건 변화에 따른 무 접촉 무선 전력 전송에 관한 연구이다. 실험은 무 접촉 방식으로 전력을 전송 할 수 있는 송신부인 1차 측 코일과 수신부인 2차 측 코일 및 하프브리지 직렬 공진 컨버터를 적용한 무선 전원 장치의 송신부 회로와 수신부회로의 출력 전압 및 전원을 계산할 수 있는 환경을 마련해 주었다. 송신부의 유도 결합 공진 컨버터의 주 전원은 태양광 전지 모듈과 대체 광원으로서 인공 광원(할로겐 램프)을 이용하여 전기 에너지로 변환 시켜 사용하였으며 태양광 발전으로부터 공급받은 24 V 전원을 무선 전력 전송 장치를 위한 입력 전원으로 사용하였다. 실험 결과, 전달 받은 전력은 수신부 회로에서 조명을 밝히거나 배터리를 충전하는데 사용된다. 그리고 송신부의 출력 측에서 측정을 통해 수신부의 입력 전력과 비교하여 무선 전력 전송 효율은 약 70~89%로 나타났다. 또한 이 논문을 위해서, 무선 전력 전송 시 이물질이 간섭하였을 때, ID 검증 방식과 전압의 위상차 비교 방법을 통해 효율성 실험을 하였다.

E급 증폭기의 바이어스 조정을 통한 LF-대역 무선 전력 전송시스템의 수신 전력 안정화 (Received Power Regulation of LF-Band Wireless Power Transfer System Using Bias Control of Class E Amplifier)

  • 손용호;한상규;장병준
    • 한국전자파학회논문지
    • /
    • 제24권9호
    • /
    • pp.883-891
    • /
    • 2013
  • 스마트폰 무선 충전 시나리오에서는 송신 패드에 비해 수신 패드의 크기가 작으므로 수신 패드의 위치에 상관없이 일정한 전력을 부하에 공급하는 것이 중요하다. 본 논문에서는 송신 패드와 수신 패드의 크기가 각각 $16cm{\times}18cm$$6cm{\times}8cm$의 직사각형 구조를 갖는 경우, 무선 전력 전송 송신부에 위치한 E급 증폭기의 Drain 바이어스 전압만을 조정하여 수신 패드의 위치에 상관없이 일정한 전력이 부하에 공급되는 방식을 제안하였다. 설계된 LF-대역 무선 전력 시스템의 구성은 PWM IC인 TL494로 제어되는 Buck converter 구조의 전원 회로, 저가의 IRF510 power MOSFET을 이용한 E급 증폭기, 송신 패드 및 수신 패드, 그리고 Schottky 다이오드를 이용한 풀 브릿지 정류기로 구성된다. 제작된 무선 전력 전송 시스템은 바이어스 조정을 하지 않는 경우 240 kHz에서 최대 4 W 출력과 67 % 이상의 시스템 효율을 가지며, 바이어스 조정을 하는 경우에는 수신 패드의 위치에 상관없이 수신 전력을 2 W로 일정하게 유지할 수 있다.

The Effects of Repetitive Transcranial Magnetic Stimulation on Balance Ability in Acute Stroke Patients

  • Ji, Sang-Goo;Shin, Young-Jun;Kim, Myoung-Kwon
    • 대한물리의학회지
    • /
    • 제11권3호
    • /
    • pp.11-17
    • /
    • 2016
  • PURPOSE: The aim of the present study was to determine whether high frequency repetitive transcranial magnetic stimulation (rTMS) can improve balance ability in acute stage stroke patients. METHODS: The study was conducted on 30 subjects diagnosed with hemiparesis caused by stroke. The experimental group consisted of 15 patients that underwent rTMS for 15 mins and the control group consisted of 15 patients that underwent sham rTMS (for 15 minutes). A 70-mm figure 8 coil and a Magstim Rapid stimulator was used in both groups. Patients in the experimental group received 10 Hz rTMS applied to the hotspot in the lesioned hemisphere in 10-second trains with 50-second intervals between trains, for 15 minutes (total 2,000 pulses). Both groups received conventional physical therapy for 30 minutes a day, 5 days a week, for 4 weeks. Static balance ability analysis was performed using the Gaitview system to measure pressure rate, postural sway, and total pressure, and dynamic balance ability analysis was performed to measure pressure variables using a balance system. RESULTS: A significant difference was observed in post-training gains for pressure rate, total pressure in static balance, and overall stability index in dynamic balance between the experimental group and the control group (p<.05). CONCLUSION: The results of this study indicate that high frequency rTMS may be beneficial for improving static and dynamic balance recovery in acute stroke patients.