• Title/Summary/Keyword: Real-time temperature monitoring

Search Result 366, Processing Time 0.023 seconds

Implementation and Performance Evaluation of Environmental Data Monitoring System for the Fish Farm (양식장 환경 데이터 모니터링 시스템의 구현 및 성능 평가)

  • Wahyutama, Aria Bisma;Hwang, Mintae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.5
    • /
    • pp.743-754
    • /
    • 2022
  • This paper contains the results of the development and performance evaluation of the environmental data monitoring system for the fish farm. For the hardware development, the analogue sensor is used to collect dissolved oxygen, pH, salinity, and temperature of the fish farm water, and the digital sensor is used for collecting ambient temperature, humidity, and location information via a GPS module to be sent to cloud-based Firebase DB. A set of LoRa transmitters and receivers is used as a communication module to upload the collected data. The data stored in Firebase is retrieved as a graph on a web and mobile application to monitor the environmental data changes in real-time. A notification will be delivered if the collected data is outside the determined optimal value. To evaluate the performance of the developed system, a response time from hardware modules to web and mobile applications is ranging from 6.2 to 6.85 seconds, which indicates satisfactory results.

Implementation of the Integrated Monitoring System for Improvement of Production Environment (생산환경 개선을 위한 통합 모니터링 시스템 구현)

  • Yoon, Jae-Hyeon;Jang, Sang-Gil;Jung, Jong-Mun;Ko, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.481-486
    • /
    • 2019
  • Smart Factory requires real-time monitoring and analysis of all process processes for optimal production environment. Monitoring system for data collection from various sensors is necessary to make all production processes automatic. By storing and analyzing the collected data, we can check whether there are any signs of abnormalities in any machine or equipment. Thus, in this paper, an integrated monitoring system for smart factory incorporating a working environment monitoring system and an automatic storage system of measurement values was implemented. By using the automatic storage system of measurement values, it is possible to carry out reliable inspection in any place without misentry. Also, through working environment monitoring system using LoRa, production environments such as temperature, humidity and atmospheric pressure can be monitored in real time.

Real-time condition assessment of railway tunnel deformation using an FBG-based monitoring system

  • Zhou, Lu;Zhang, Chao;Ni, Yi-Qing;Wang, Chung-Yue
    • Smart Structures and Systems
    • /
    • v.21 no.5
    • /
    • pp.537-548
    • /
    • 2018
  • A tunnel deformation monitoring system is developed with the use of fiber Bragg grating (FBG) sensing technique, aiming at providing continuous monitoring of railway tunnel deformation in the long term, and early warning for the rail service maintainers and authorities to avoid catastrophic consequences when significant deformation occurs. Specifically, a set of FBG bending gauges with the ability of angle measurement and temperature compensation is designed and manufactured for the purpose of online monitoring of tunnel deformation. An overall profile of lateral tunnel displacement along the longitudinal direction can be obtained by implementing an array of the FBG bending gauges interconnected by rigid rods, in conjunction with a proper algorithm. The devised system is verified in laboratory experiments with a test setup enabling to imitate various patterns of tunnel deformation before the implementation of this system in an in-service high-speed railway (HSR) tunnel.

Real-time Monitoring of Environmental Properties at Seaweed Farm and a Simple Model for CO2 Budget (해조양식장 수질환경 모니터링을 통한 이산화탄소 단순 수지모델)

  • Shim, Jeong Hee;Kang, Dong-Jin;Han, In Sung;Kwon, Jung No;Lee, Yong-Hwa
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.17 no.4
    • /
    • pp.243-251
    • /
    • 2012
  • Real-time monitoring for environmental factors(temperature, salinity, chlorophyll, etc.) and carbonate components( pH and $fCO_2$) was conducted during 5-6th of July, 2012 at a seaweeds farm in Gijang, Busan. Surface temperature and salinity were ranged from $12.5{\sim}17.6^{\circ}C$ and 33.7~34.0, respectively, with highly daily and inter-daily variations due to tide, light frequency(day and night) and currents. Surface $fCO_2$ and pH showed a range of $381{\sim}402{\mu}atm$ and 8.03~8.15, and chlorophyll-a concentration in surface seawater ranged 0.8~5.8 ${\mu}g\;L^{-1}$. Environmental and carbonate factors showed the highest/lowest values around 5 pm of 5th July when the lowest tidal height and strongest thermocline in the water column, suggesting that biological production resulted in decrease of $CO_2$ and increase of pH in the seaweed farm. Processes affecting the surface $fCO_2$ distribution were evaluated using a simple budget model. In day time, biological productions by phytoplankton and macro algae are the main factors for $CO_2$ drawdown and counteracted the amount of $CO_2$ increase by temperature and air-sea exchange. The model values were a little higher than observed values in night time due to the over-estimation of physical mixing. The model suggested that algal production accounted about 14-40% of total $CO_2$ variation in seaweed farm.

Temperature Detection and Monitoring System of Livestock Through Ear-Tag Based on IoT (IoT 기반의 이표를 통한 가축 온도 변화 감지 및 모니터링 시스템)

  • Park, Young-Soo;Park, Kyoung-Yong;Kim, Min-Sun;Park, Jun-Kyu;Kwon, Seong-Geun
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.3
    • /
    • pp.474-481
    • /
    • 2017
  • In Korea, foot-and-mouth disease has not been reported for several decades, but it began to develop again in 2000. For 2010~2011, when the worst occurred, 3.5 million animals were disposed of resulting in a loss of 2.8 trillion won. In order to prevent the harmful effects of foot-and-mouth disease, vaccination and housing management are being implemented. Despite these measures, foot-and-mouth disease is infected with air through the respiratory tract and accompanies fever after latency. Therefore, it is recognized that measuring and managing the body temperature of livestock at the early stage is the first step of managing this disease. In this paper, we propose a temperature monitoring system that can measure the body temperature by incorporating temperature sensor mounted in ear-tag of cattle and collect body temperature data of each individual cattle through BLE into the control server. The proposed body temperature monitoring system has various advantages such as easy installation without the help of livestock specialists and not damaging the organs of the livestock. So, it is possible to manage the abnormal symptom of cattle in real time and it is believed that the proposed monitoring system will revolutionize the prevention of foot-and-mouth disease.

Measurement of temperature profile in molter metal using a cod camera (ccd 카메라를 이용한 금속 용융면의 온도분포측정)

  • 노시표;정의창;임창환;김철중
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.1
    • /
    • pp.64-69
    • /
    • 2003
  • Using a high fewer electron beam gun (max. power 20 kW), Gadolinium (Gd, atomic number 64) metal was melted and the temperature distribution of melted surface was measured. With proper optical filters and the adjustment of aperture of lens, the radiation of melted surface was received by a ccd camera and its signal transferred to a computer. The real time monitoring of melted surface with a variation of electron beam Power was Possible and stable operation of electron beam was achieved. It was found that the max. temperature measured by a ccd camera with an assumption of blackbody radiation of melted Gd surface and adaption of Planet's law was above 100~$200^{\circ}C$ compared to that measured by a pyrometer in the same e-beam power.

Temperature Distribution Monitoring of Transformer Using IRR-Camera (적외선방사카메라를 이용한 변압기 온도분포 모니터링)

  • 이우선;정찬문;서용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.459-462
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of Power transformer is measured with partial temperature distribution in real time.

  • PDF

Temperature Distribution Monitoring of Transformer (변압기 온도 변화특성 모니터링)

  • Lee, Woo-Sun;Jung, Chan-Moon;Son, Dong-Min;Seo, Young-Jin;Lim, Jang-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.69-72
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of power transformer is measured with partial temperature distribution in real time.

  • PDF

A Study on Home's Emergency Monitoring System Using Embedded System (임베디드 시스템을 이용한 가택의 긴급상황 감시 시스템에 대한 연구)

  • 최재우;양승현;노방현;황희융
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.1
    • /
    • pp.60-64
    • /
    • 2004
  • In this paper, we implemented a real-time remote home monitoring system which we have ported the Linux OS and HTTP(Hypertext Transfer Protocol) web server. The GoAhead web server was ported using by ARM cross compiler. And then we used the analog to digital converter ADC0809 for sensing the vii able input signal at widely separated home. We have implemented linux device driver for ADC(Analog to Digital Convertor) and CGI-C(Common Gateway Interface - C language) application program using Client pull method for monitoring real-time changing data. The factor of monitoring is temperature, intensity of illumination and gas's existence. And this system has ability which check the status of out door and gas valve. We have designed the embedded web server system for home emergency monitoring in low cost.

  • PDF

Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers (보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법)

  • Jung, Jae-Jin;Song, Jung-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF