• Title/Summary/Keyword: Real-time control and monitoring

Search Result 949, Processing Time 0.032 seconds

Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map (서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발)

  • Lee, Eun-Sun;Park, Min-Bin;Lee, Tae-Jung;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

Recent Developments and Field Application of Foreign Waterworks Automatic Meter Reading (국외 상수도 원격검침시스템의 개발 동향 및 현장 적용 사례 고찰)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuk;Ko, Kyung-Rok;Oh, Hyun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.863-870
    • /
    • 2012
  • The market trends of automatic meter reading associated with smart water meters were investigated. Also, recent developments and field applications of key technology for automatic meter reading associated with smart water meters were analyzed. Smart water meters have been manufactured mostly in United States and Europe and have been expanded their business to Asia. Integrated water management system combining with the additional functions such as real-time consumption metering, cost notification, water conservation, leak detection, water quality monitoring, and flow control have been operated in automatic meter reading. Both water quality and quantity data measured from smart water meters and sensors were transferred to data concentration units through neighborhood area network, and then were transferred to integrated server through wide area network. The data transfer methods were determined by comprehensively considering urban scale, density of smart water meters, power supply and network topologies. Common data collection methods such as fixed network to data concentation units, vehicles drive by, people walk by, and drone fly by have been applied. The automatic meter reading associated with smart water meters are spread throughout the world, and both water and energy savings result in saving the money and reducing the greenhouse gases emission.

A Design and Implementation of Mobile Logistics Information System (모바일 물류정보시스템 설계 및 구현)

  • Lee, Won-Joo;Lee, Sang-Jun;Lim, Heon-Yong;Kim, Chang-Hyeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.7
    • /
    • pp.139-146
    • /
    • 2012
  • In this paper, we implement an m-LIS(Mobile-Logistics Information System) for an effective logistics management in consideration of logistics process and work environment. The m-LIS could perform the entire business process every minute and promote the work efficiency by tying up with ERP and POS system. Moreover, this system could enhance the management level of service and supply chain. Due to the reason that the existing logistics business was not computerized and automated, most of operation was accomplished by means of workers experience and convention. This problem brought about both the ineffective management and logistics quality deterioration by weakening the control power of the logistics site. In order to solve this problem, we put focus on providing the real-time operation monitoring environment on the spot, the satisfaction of the efficiency on the spot, and the optimized system by building up the logistics information system. Furthermore, we attest that the new logistics system could properly cope with the increase of the quantity of goods transported owing to stable logistics information support and the market expansion and growth caused by the firm interface between the new ERP and its related system.

Research on Communication and The Operating of Server System for Vehicle Diagnosis and Monitoring (차량진단 및 모니터링을 위한 통신과 서버시스템 운용에 관한 연구)

  • Ryoo, Hee-Soo;Won, Yong-Gwan;Park, Kwon-Chul
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.6
    • /
    • pp.41-50
    • /
    • 2011
  • This article is concerned with the technology to provide car driver the car's status which are composed of car trouble code in car engine and many sensors. In addition, it installs vehicle diagnostic programs on wireless communication's portable device, for example, Smart phone, PDA, PMP, UMPC. As a result, this is to provide car manager with many information of car sensors when we go to car maintenance. it can monitor relevant information on vehicle by portable device in real time, alert drivers with specific messages and also enable them to address abnormalities immediately. Moreover, the technology could help the drivers who perhaps don't know very well about their vehicles to drive safely and economically as well; the reason is because the whole system is composed of just Vehicle-information collecting device and personal wireless communication's portables and transfers the relating data to server computers through wireless network in order to handle information on vehicles. This technology make us monitor vehicle's running, failure and disorder by using wireless communication's portable device. Finally, this study system is composed of a lot of application to display us the car's status which get car's inner sensor information while driving a car.

A Study of Evacuation Route Guidance System using Location-based Information (위치기반 정보를 활용한 비상대피경로 안내 지원시스템 개발)

  • Kim, Ho-Kyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.18-23
    • /
    • 2017
  • The shipyard quay process struggles to control workers and maintain a secure working environment because of the presence of at least 1,000 people. Therefore, safety accidents such as an explosion or a fire are likely to occur. With the recent increase in safety accidents at shipyards, the requirements for safety and process monitoring have been strengthened. Major shipyards are conducting researchto monitor the process in real time and to detect the work environment for safety. In this paper, we propose a safe and accurate evacuation route based on the information of the dangerous area and the user's location based on a mobile application to reduce the casualty accidents in the presence of many personnel in a concentrated area. To do this, we analyze the trend of the fire escape system on the ground building, compare various algorithms for escape route calculation, select appropriate algorithms for this study, and perform programming. A basic experiment was conducted to confirm the results. The proposed method is expected to be used in large ship construction sites, passenger ships and large public facilities to reduce accidents in the case of a safety accident.

Implementation of the automatic standby power blocking socket outlet having a blocking power threshold per electronic device by the smart machine (스마트 기기에 의해 전자기기별 차단전력문턱치 설정기능이 장착된 자동대기전력 차단콘센트 구현)

  • Oh, Chang-Sun;Park, Chan-Young;Kim, Dong-Hoi;Kim, Gi-Taek
    • Journal of Digital Contents Society
    • /
    • v.15 no.4
    • /
    • pp.481-489
    • /
    • 2014
  • In this paper, the automatic standby power blocking socket outlet to reduce standby power by blocking power threshold is implemented. Where, the standby power means a flowing power when a disused power electronic is plugged into the socket outlet. The proposed socket outlet can cut off the standby power by establishing a proper block power threshold electronic device according to each electronic device because it can monitor the amount of power through the smart machines such as the real-time PC or mobile phone and directly control the blocking power threshold. The software is implemented by using Visual Studio software, code vision and SN8 C studio, and the hardware is embodied in ATmega128, SN8F27E93S, USB to UART, and relay etc. Through the simulation, we find that the standby power of the proposed method is similar to that of the conventional method in case of the cellular phone but the standby power of the proposed method is much less than that of the conventional method in case of the computer, air conditioning, and set-top box. Therefore, it is proved that the proposed socket outlet has a superior performance in terms of the standby power.

The Construction of QoS Integration Platform for Real-time Negotiation and Adaptation Stream Service in Distributed Object Computing Environments (분산 객체 컴퓨팅 환경에서 실시간 협약 및 적응 스트림 서비스를 위한 QoS 통합 플랫폼의 구축)

  • Jun, Byung-Taek;Kim, Myung-Hee;Joo, Su-Chong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.11S
    • /
    • pp.3651-3667
    • /
    • 2000
  • Recently, in the distributed multimedia environments based on internet, as radical growing technologies, the most of researchers focus on both streaming technology and distributed object thchnology, Specially, the studies which are tried to integrate the streaming services on the distributed object technology have been progressing. These technologies are applied to various stream service mamgements and protocols. However, the stream service management mexlels which are being proposed by the existing researches are insufficient for suporting the QoS of stream services. Besides, the existing models have the problems that cannot support the extensibility and the reusability, when the QoS-reiatedfunctions are being developed as a sub-module which is suited on the specific-purpose application services. For solving these problems, in this paper. we suggested a QoS Integrated platform which can extend and reuse using the distributed object technologies, and guarantee the QoS of the stream services. A structure of platform we suggested consists of three components such as User Control Module(UCM), QoS Management Module(QoSM) and Stream Object. Stream Object has Send/Receive operations for transmitting the RTP packets over TCP/IP. User Control ModuleI(UCM) controls Stream Objects via the COREA service objects. QoS Management Modulel(QoSM) has the functions which maintain the QoS of stream service between the UCMs in client and server. As QoS control methexlologies, procedures of resource monitoring, negotiation, and resource adaptation are executed via the interactions among these comiXments mentioned above. For constmcting this QoS integrated platform, we first implemented the modules mentioned above independently, and then, used IDL for defining interfaces among these mexlules so that can support platform independence, interoperability and portability base on COREA. This platform is constructed using OrbixWeb 3.1c following CORBA specification on Solaris 2.5/2.7, Java language, Java, Java Media Framework API 2.0, Mini-SQL1.0.16 and multimedia equipments. As results for verifying this platform functionally, we showed executing results of each module we mentioned above, and a numerical data obtained from QoS control procedures on client and server's GUI, while stream service is executing on our platform.

  • PDF

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Critical Pathway Development for the Hysterectomy Patients and its applied Effect (자궁적출술 환자를 위한 critical pathway 개발과 적용효과)

  • Noh, Gi-Ok;Park, Kyung-Sook
    • Women's Health Nursing
    • /
    • v.6 no.2
    • /
    • pp.234-257
    • /
    • 2000
  • At present in the medical care, the study and effort for producing health service to consider efficiency, effectiveness, and quality are urgently called for because of the difficulty in the keen competition according to the inter- nationalization and opening, the operation in the medical institution service testing system, the change in the medical policy of KDRGs, and the lack of the health care cost increasing rate. As an alternative, the case management for the new management system is introduced in the U.S., and the Critical Pathway that is the method designing the contents of activity and its result has been developed and applied in order to anticipate and manage the patient-outcome for the realization of the cost-effective case-management. Thus, this study intended to analyze the effectiveness to obtain by developing the Critical Pathway presented as the method to improve the quality-betterment and cost effectiveness through the continuous and consistent patient management for the hysterectomy patient and applying it to the real practice. As a study method, this author formed a conceptual framework through considering five Critical Pathway used in the current U.S. and three Critical Pathway presented in the literature to develop the Critical Pathway for the hysterectomy patient, and made out the preliminary Critical Pathway through reviewing the old chart. This author made the verified the validity of the expert group about the developed Critical Pathway, and to confirm the possibility of practice application, completed and settled the final Critical Pathway after using the Critical Pathway to the hysterectomy patient from March 1st to 15th, 1997. Finally, to analyze the application-effect of the developed Critical Pathway, this author offered health care service applying the Critical Pathway to the hysterectomy patient from April 15th to August 31th, 1997. The guide for the Critical Pathway was carried out in advance by outpatient setting nurse for outpatient setting visit before the operation, and after hospitalization the primary nurse monitored the execution degree on the every duty. After discharge this author surveyed the complication through phone visiting, and one month after discharge surveyed the patient's reaction about the offered service when outpatient setting visit and analyzed the result. The source for health care cost was obtained by the statistics about the hospital charge which was offered by the General Business Department. The results were as follows. 1. It was decided that the vertical line of the Critical Pathway was made up of eight items such as monitoring/assessment, treatment, line/drains, activity, medication, lab test, diet, patient teaching, and the horizontal line of the Critical Pathway was made up of from hospitalization to discharge. 2. After the analysis of service contents through reviewing the old chart, it was decided that the horizontal line of the preliminary Critical Pathway was made up of from hopitalization to fourth postoperative day, and the vertical line of it was divided into eight items which were the contents to occur with the time frame of the horizontal line. 3. After the verifying the validity of the expert group about the preliminary Critical Pathway, the horizontal line was amended from hopitalization to third postoperative day, and taking their consensus, some contents of the horizontal line was amended and deleted. 4. From March 1st to 15th, 1997, to confirm the clinical suitability, this author offered eight hysterectomy patients the medical service through the Critical Pathway. The result was that three of them could be discharged at the expected discharge day, and the others later than that day. Supplementing the preliminary Critical Pathway through analyzing the cause of that delay- case, this author developed the final Critical Pathway. 5. There were no significant differences between the experimental and the control group in the incidence of complication(P > 0.05). 6. The 92.4% of experimental group was satisfied with the Critical Pathway service. 7. The length of hospital stay of the experimental group offered with the Critical Pathway service was 4.6 days and there was a significant difference that it was 1.3 days shorter than that of the control group(t=-29.514, P=0.000). 8. There wsa a significant difference that the mean medical charge per one patient of the experimental group offered the Critical Pathway service was cheaper \124,150 than that of the control group(t=-9.826, P=0.000). 9. The result that the author assumed and analyzed hospital income with the rate of turning bed was assumed that the increase of hospital income was \63,245,072 for that study, and the income increase was expected with \68,704,864 for a year. The result that this author applied the Critical Pathway to the hysterectomy patient have no differences in the incidence of complication, high satisfaction with that service, and the length of hospital stay decreased in the experimental group, and the mean hospital charge per one patient decreased, but hospital income increased. Suggestions for further study and nursing practice are as follows. 1. The study to apply the Critical Pathway for a year, verify the validity, and measure the effect repeatedly is needed. 2. To apply and manage the Critical Pathway effectively, the study to computerize it is needed. 3. The study to develop hospital-based Critical Pathway about other diseases or procedure, and measure the effect is needed.

  • PDF

Monitoring the Reoccurrence of Fire Blight and the Eradication Efficiency of Erwinia amylovora in Burial Sites of Infected Host Plants Using Sentinel Plants (미끼식물을 이용한 화상병 감염 기주 매몰지 내 화상병균 제거 효율 검증 및 병 재발 모니터링)

  • In Woong, Park;Yu-Rim, Song;Nguyen Trung, Vu;Eom-Ji, Oh;In Sun, Hwang;Hyeonheui, Ham;Seong Hwan, Kim;Duck Hwan, Park;Chang-Sik, Oh
    • Research in Plant Disease
    • /
    • v.28 no.4
    • /
    • pp.221-230
    • /
    • 2022
  • The fire blight caused by Erwinia amylovora (Ea) was first reported in 2015 in Korea, and the disease has rapidly spread to 22 regions until 2021. In Korea, all host plants in the apple and pear orchards where fire blight occurred should be eliminated and buried by the Plant Protection Act. To prevent the spread of the disease, all burial sites were prohibited from planting the new host plants for the next three years. To confirm the eradication efficiency of Ea and the reoccurrence of fire blight, the surveillance facilities were established on three burial sites from 2019 to 2020 in Anseong-si, Gyeonggi-do, and Chungju-si, Chungcheongbuk-do. As host plants, five apple trees of fire blight-susceptible cultivar 'Fuji', were planted in each facility. All facilities were enclosed with fences and nets and equipped with two CCTVs, motion sensors, and several other sensors for recording weather conditions to monitor the environment of the sentinel plants in real-time. The sentinel plants were checked for the reoccurrence of fire blight routinely. Suspicious plant parts were collected and analyzed for Ea detection by loop-mediated isothermal amplification polymerase chain reaction and conventional polymerase chain reaction. Until November 2022, Ea has not been detected in all sentinel plants. These results might support that the burial control of infected plants in soil works efficiently to remove Ea and support the possibility to shorten the prohibition period of host plant establishment in the burial sites.