• Title/Summary/Keyword: Real-Time monitoring

Search Result 3,612, Processing Time 0.033 seconds

Long-term Trend Analysis of Major Tributaries of Nakdong River Using Water Quality Index (수질지수를 이용한 낙동강 주요 지류지천의 장기 경향성 분석)

  • Park, Jaebeom;Kal, Byungseok;Kim, Sanghun
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.201-209
    • /
    • 2018
  • In this study, the water quality index was calculated using the water quality monitoring data of the major tributaries of the Nakdong River and long-term trend analysis was performed to identify the tributaries requiring priority management. We used a Real-Time Water Quality Index method implemented by the Ministry of Environment. Linear regression as a parametric method and Mann-Kendall Test and Sen Slope Test as a nonparametric method were applied for the trend analysis. The water quality index of major tributaries except for Migeon2 and Seokyo2 was in the range below Fair grade and there were no significant trends for the rest of the sites except Bukan, Chennae, Hogye, Yongdeok. Therefore, in order to improve the water quality of the main stream, management of the tributaries should be preceded.

Recent Development of Rapid and Automation Technology for Food Microbiological Examination

  • Hiroshi Kurata
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 1996.06a
    • /
    • pp.33-33
    • /
    • 1996
  • Interests in the field of rapid methods and automation in microbiology have been growing steadily on an international scale in recent years. International meetings concerned this problem have been held in elsewhere in the world countries since the past twenty years. But, unfortunately in the field of microbial examination in food hygiene, this problem have not yet been developed so much as in the field of clinical microbiology. Today, I would like to introduce you here present aspects of rapid and automation technologies, those which are manly carrying in milk and meats industries. My illustration will be given recent improved technologies using automatic apparatus and instruments along with process of microbial count procedure. Recent direct microbiological counting system (ChemeScan \ulcorner) as real time ultrasensitive analysis created by Cheminex Ltd., France is now most evolutional instrument to provide direct microbial counts, down to one cell, within 30 minutes. The results from these evaluations how a good correlation between the ChemScan system and the standard plate count method. This system will be successful application for not only in the field of pharmacology but also food microbiology. In addition, current identification of microbes by sophisticated instruments suitable for food microbiology, one of which Biology is manual system (BIOLOG\ulcorner), provides reference-level capability at a modes price. For the manual system, the color reactions in the microplate are read by eye and manually keyed into personal computer. Species identification appears on the computer screen within seconds, along with biotype patterns, a list of closely related species, and other useful statistics. In present this is useful application for microbial ecology and epidemiological survey. RiboPrinter system newly produced by DuPont is now focusing among microbiologists in the world, and is one of the biggest microbial characterization system using a DNA-based approach. The technology analyzer is bacterial culture for its genetic fingerprint or riboprint pattern. Finally Bio-cellTracer system for automatic measurement of fungal growth and Fukitori-Maseter, a Surface Hygiene Monitoring Kit by using swabe procedure in food processing environment are briefly illustrated in this presentation.

Fixed IP-port based Application-Level Internet Traffic Classification (고정 IP-port 기반 응용 레벨 인터넷 트래픽 분석에 관한 연구)

  • Yoon, Sung-Ho;Park, Jun-Sang;Park, Jin-Wan;Lee, Sang-Woo;Kim, Myung-Sup
    • The KIPS Transactions:PartC
    • /
    • v.17C no.2
    • /
    • pp.205-214
    • /
    • 2010
  • As network traffic is dramatically increasing due to the popularization of Internet, the need for application traffic classification becomes important for the effective use of network resources. In this paper, we present an application traffic classification method based on fixed IP-port information. A fixed IP-port is a {IP address, port number, transport protocol}triple dedicated to only one application, which is automatically collected from the behavior analysis of individual applications. We can classify the Internet traffic more accurately and quickly by simple packet header matching to the collected fixed IP-port information. Therefore, we can construct a lightweight, fast, and accurate real-time traffic classification system than other classification method. In this paper we propose a novel algorithm to extract the fixed IP-port information and the system architecture. Also we prove the feasibility and applicability of our proposed method by an acceptable experimental result.

Design and Implementation of High-Resolution Image Transmission Interface for Mobile Device (모바일 환경을 위한 맞춤형 서비스 유비쿼터스 영상전송 시스템의 설계)

  • Lee, Sang-Wook;Ahn, Yong-Beom;Kim, Eung-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.791-799
    • /
    • 2008
  • An image recognition for surrounding conditions is very important in image transmission. In recently rears, as the information infrastructure is more general, the user-centered demands in which they want to identify by object's states image using wire or wireless environment have increased. However, existing mobile solution could be hard to expect high quality mage, because limitation of software processing according as network based on mobile terminal which has low band width supports software codec. To solve this weak point, this paper describes on hardware codec design based on MPEG-4 which is international video compression standard. Implemented system contains the embedded CPU for optimized design and it works high quality service as transmission speed and resolution in mobile circumstance.

Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction (조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구)

  • Jeong, Cheol-Ki;Jang, Han;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

Development of Geostationary Ocean Color Imager (GOCI) (정지궤도 해색탑재체(GOCI)의 개발)

  • Cho, Seong-Ick;Ahn, Yu-Hwan;Ryu, Joo-Hyung;Kang, Gm-Sil;Youn, Heong-Sik
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.2
    • /
    • pp.157-165
    • /
    • 2010
  • In June 2010, Geostationary Ocean Color Imager (GOCI), the world's first ocean color observation satellite will be launched. GOCI is planned for use in real-time monitoring of the ocean environment around Korean Peninsula by daily analysis of ocean environment measurements of chlorophyll concentration, dissolved organic matter, and suspended sediments taken eight times per day for seven years. GOCI primary data will support a fishery information service and red tide forecasting, and ocean climate change research. In this paper, the development background of GOCI, user requirements, GOCI architecture, and the GOCI on-orbit operational concept are explained.

A Study of Simple Sleep Apnea Predictive Device Using SpO2 and Acceleration Sensor

  • Woo, Seong-In;Lee, Merry;Yeom, Hojun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.71-75
    • /
    • 2019
  • Sleep apnea is a disease that causes various complications, and the polysomnography is expensive and difficult to measure. The purpose of this study is to develop an unrestricted wearable monitoring system so that patients can be examined in a familiar environment. We used a method to detect sleep apnea events and to determine sleep satisfaction by non-constrained method using SpO2 measurement sensor and 3-axis acceleration sensor. Heart rate and SpO2 were measured at the finger using max30100. After acquiring the SpO2 data of the user in real time, the apnea measurement algorithm was used to transmit the number of apnea events of the user to the mobile phone using Bluetooth (HC-06) on the wrist. Using the three-axis acceleration sensor (mpu6050) attached to the upper body, the number of times of tossing and turning during sleep was measured. Based on this data, this algorithm evaluates the patient's tossing and turning during sleep and transmits the data to the mobile phone via Bluetooth. The power source used 9 volts battery to operate Arduino UNO and sensors for portability and stability, and the data received from each sensor can be used to check the various degree between sleep apnea and sleep tossing and turning on the mobile phone. Through thisstudy, we have developed a wearable sleep apnea measurement system that can be easily used at home for the problem of low sleep efficiency of sleep apnea patients.

Development of Language Rehabilitation Program Using the Smart Device-based Application (스마트 기기 기반 언어재활 프로그램 개발)

  • Hwang, Yu Mi;Park, Kinam;Jung, Young Hee;Pyun, Sung-Bom
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.321-327
    • /
    • 2019
  • The purpose of this study is to develop a smart device-based Language Rehabilitation Program (LRP) to improve communication ability for the patients with language disability. The content of the LRP includes a variety of semantic categories and grammatical elements and consists of 17 semantic categories, 29 tasks and 3780 items to improve comprehension/production ability at word level, semantic category level, sentence level and discourse level. We developed LRP as a Windows-base management program and an Android-base language rehabilitation application. LRP was developed into an application for smart devices, providing real-time delivery of training contents, measurement and database of training task results, and patient progress and monitoring. A follow-up study will be conducted on the verification of the language rehabilitation effect using LRP by patients with language disability.

Current State and Limit of Mobile-Based Mental Health Intervention Using Information & Communication Technology (정보통신기술(Information & Communication Technology)을활용한 모바일 기반 정신건강개입의 현황과 한계)

  • Lee, Sang Min;Kim, Seung-Jun;Im, Woo-Young;Paik, Jong-Woo
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.24 no.1
    • /
    • pp.61-65
    • /
    • 2016
  • Currently, a variety of Information and Communication Technology(ICT) is being broadly utilized for mental health. Especially, mobile application is one of the effective ICT, and several applications have been developed after the spread of smartphones. The mobile-based mental health has several strengths, such as better treatment accessibility and easier check-ups of symptoms or daily activities by real-time monitoring. Better follow-ups of treatment course, more customized feedback and better transportability enable patients to be more adherent. However, there are some limitations of mobile technology about the mental health, such as technical troubles of electric errors, data safety problems and personal information extrusion. Therefore, full considerations should be given during the development and provision of the technology. Most of all, mental health specialists should actively participate in the development process by incorporation of evidence-based experiences and assurance of good clinical qualities.

Development of a Portable and Disposable pH Sensor Based on Titanium Wire with High Electrochemical Sensing Performance (우수한 전기화학적 센싱 성능을 지닌 티타늄 와이어 기반의 휴대 및 일회용 pH 센서 개발)

  • Yoon, Eun Seop;Yoon, Jo Hee;Son, Seon Gyu;Kim, Seo Jin;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.700-705
    • /
    • 2021
  • A portable and disposable pH sensor based on Ti wire was successfully developed for monitoring hydronium ion concentrations. A sensing electrode was prepared by electrochemically depositing iridium oxide onto a Ti wire, while a reference electrode was fabricated by coating Ag/AgCl ink on a Ti wire. Combining the two electrodes in the pH sensor enabled the collection of open circuit potential signals when the sensor was immersed in solutions of various pH values. The pH sensor exhibited excellent electrochemical sensing performance in terms of sensitivity, response time, repeatability, selectivity, and stability. To demonstrate point-of-measurement applications, the pH sensor was integrated with a wireless electronic module that could communicate with a mobile application. The portable pH sensor accurately measured pH changes in real samples. The results obtained were consistent with those of using a commercial pH meter.