• Title/Summary/Keyword: Real time injection

Search Result 198, Processing Time 0.023 seconds

Detecting SQL Injection Logs Leveraging ELK Stack (ELK Stack을 활용한 SQL Injection 로그 탐지)

  • Min, Song-ha;Yu, Hyun-jae;Lim, Moon-ju;Kim, Jong-min
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.337-340
    • /
    • 2022
  • SQL Injection attacks are one of the older attack techniques and are the dominant type of hacking attempts against web services. There have been many attempts to hack SQL injection attacks by exposing data or obtaining privileges. In this paper, we implement a log analysis system that can respond to SQL injection attacks in real time using the open source ELK Stack. did. By providing a visualization of SQL injection attack log data through the implemented system, it is expected that users will be able to easily grasp the degree of attack risk and quickly prepare for attacks.

  • PDF

A Dynamic Model of a Gas Engine-Driven Heat Pump in Cooling Mode for Real-Time Simulation

  • Shin, Young-Gy;Yang, Hoon-Cheul;Tae, Choon-Seob;Jang, Cheol-Yong;Cho, Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.3
    • /
    • pp.85-93
    • /
    • 2006
  • The present study has been conducted to simulate dynamics of a gas engine-driven heat pump (GHP) for the design of control algorithm. The dynamic model of a GHP was based on conservation laws of mass and energy. For the control of refrigerant pressures, actuators such as an engine throttle valve, outdoor fans, coolant three-way valves and liquid injection valves were controlled by P or PI algorithm. The simulation results were found to be realistic enough to be applied for the control algorithm design. The model could be applied to build a virtual real-time GHP system so that it interfaces with a real controller for the purpose of developing control algorithm.

Analysis of Inadvertent Intradiscal Injections during Lumbar Transforaminal Epidural Injection

  • Hong, Ji Hee;Lee, Sung Mun;Bae, Jin Hong
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.168-173
    • /
    • 2014
  • Background: Recently, there have been several case reports and retrospective studies about the incidence of intradiscal (ID) injection during transforaminal epidural steroid injection (TFESI). Inadvertent ID injection is not a rare complication, and it carries the risk of developing diskitis, although there has been no report of diskitis after TFESI. We prospectively evaluated the incidence of inadvertent ID injection during lumbar TFESI and analyzed the contributing factors. Methods: Ten patients received 2-level TFESI, and the remaining 229 patients received 1-level TFESI. When successful TFESI was performed, 2 ml of contrast dye was injected under real-time fluoroscopy to check for any inadvertent ID spread. A musculoskeletal radiologist analyzed all magnetic resonance images (MRIs) of patients who demonstrated inadvertent ID injection. When reviewing MRIs, the intervertebral foramen level where ID injection occurred was carefully examined, and any anatomical structure which narrowing the foramen was identified. Results: Among the 249 TFESI, we identified 6 ID injections; thus, there was an incidence of 2.4%. Four patients had isthmic spondylolisthesis, and the level of spondylolisthesis coincided with the level of ID injection. We further examined the right or left foramen of the spondylolisthesis level and identified the upward migrated disc material that was narrowing the foramen. Conclusions: Inadvertent ID injection during TFESI is not infrequent, and pain physicians must pay close attention to the type and location of disc herniation.

The prediction of the optimum injection conditions of aspherical lens by using FEM and Neural Network (비구면 광학렌즈 성형에 있어서 유한요소법과 신경회로망을 이용한 사출조건 예측 시스템의 개발)

  • 곽태수;스즈키토오루;오오모리히토시;배원병
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.168-171
    • /
    • 2002
  • A neural network model for predicting the quality or soundness of the injected plastic aspherical lens based on process parameters has been developed. The approach uses a Real Time Recurrent Neural Network 4-5-2 (RTRN) trained based on input/output data that were taken from FE analysis worts carried out through a CAE software. The system has been developed to search an optimum set of process parameters and reduce the time required for planning the conditions of plastic injection molding at the design stage.

  • PDF

Lunar ascent and orbit injection via locally-flat near-optimal guidance and nonlinear reduced-attitude control

  • Mauro, Pontani
    • Advances in aircraft and spacecraft science
    • /
    • v.9 no.5
    • /
    • pp.433-447
    • /
    • 2022
  • This work deals with an explicit guidance and control architecture for autonomous lunar ascent and orbit injection, i.e., the locally-flat near-optimal guidance, accompanied by nonlinear reduced-attitude control. This is a new explicit guidance scheme, based on the local projection of the position and velocity variables, in conjunction with the real-time solution of the associated minimum-time problem. A recently-introduced quaternion-based reduced-attitude control algorithm, which enjoys quasi-global stability properties, is employed to drive the longitudinal axis of the ascent vehicle toward the desired direction. Actuation, based on thrust vectoring, is modeled as well. Extensive Monte Carlo simulations prove the effectiveness of the guidance, control, and actuation architecture proposed in this study for precise lunar orbit insertion, in the presence of nonnominal flight conditions.

Optical Imaging Technology for Real-time Tumor Monitoring

  • Shin, Yoo-kyoung;Eom, Joo Beom
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.123-131
    • /
    • 2021
  • Optical imaging modalities with properties of real-time, non-invasive, in vivo, and high resolution for image-guided surgery have been widely studied. In this review, we introduce two optical imaging systems, that could be the core of image-guided surgery and introduce the system configuration, implementation, and operation methods. First, we introduce the optical coherence tomography (OCT) system implemented by our research group. This system is implemented based on a swept-source, and the system has an axial resolution of 11 ㎛ and a lateral resolution of 22 ㎛. Second, we introduce a fluorescence imaging system. The fluorescence imaging system was implemented based on the absorption and fluorescence wavelength of indocyanine green (ICG), with a light-emitting diode (LED) light source. To confirm the performance of the two imaging systems, human malignant melanoma cells were injected into BALB/c nude mice to create a xenograft model and using this, OCT images of cancer and pathological slide images were compared. In addition, in a mouse model, an intravenous injection of indocyanine green was used with a fluorescence imaging system to detect real-time images moving along blood vessels and to detect sentinel lymph nodes, which could be very important for cancer staging. Finally, polarization-sensitive OCT to find the boundaries of cancer in real-time and real-time image-guided surgery using a developed contrast agent and fluorescence imaging system were introduced.

Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval (초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법)

  • Lim, Jong Bum;Kim, Young Ki;Kim, Sung Woo;Sung, Kyu Wan;Jung, Il;Lee, Chung
    • The Korean Journal of Pain
    • /
    • v.21 no.1
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

A study on the micro pattern replication properties of large area in injection molding (대면적 미세패턴 사출성형에서의 전사 특성 실험)

  • Kim, T.H.;Yoo, Y.E.;Je, T.J.;Kim, C.W.;Park, Y.W.;Choi, D.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.05a
    • /
    • pp.205-208
    • /
    • 2007
  • We injection molded a thin plate with micro prism patterns on its surface and investigated the fidelity of replication of the micro pattern depending on the process parameter such as mold temperature, injection rate or packing pressure. The size of the $90^{\circ}$ prism pattern is $50{\mu}m$ and the size of the plate is $400mm{\times}400mm$. The thickness is 1mm. The fidelity of the replication turned out quite different according to the process parameters and location of the patterns of the plate. We measured the cavity pressure and temperature in real-time during the molding to analyze the effect of the local melt pressure and temperature on the micro pattern replication.

  • PDF

A study on the prizm pattern replication in injection molding (사출 도광판의 프리즘 패턴 전사성에 관한 실험적 연구)

  • Kim, Chang-Wan;Yoo, Yeong-Eun;Kim, Tae-Hoon;Je, Tae-Jin;Choi, Doo-Sun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1537-1541
    • /
    • 2007
  • We injection molded a wedge type of plate with micro prizm patterns on its surface and investigated the fidelity of replication of the micro pattern depending on the process parameter such as mold temperature, melt temperature, injection rate or packing pressure. The size of the size of the $90^{\circ}$ prizm pattern is $50{\mu}m$ and the size of the plate is about 300㎜${\times}$200㎜. The thicknesses are 2.6㎜. and 0.7mm at each edge of the wedge type of plate. The fidelity of the replication turned out quite different according to the process parameters and location of the patterns on the plate. We measured the cavity pressure and temperature in real-time during the molding to analyze the effect of the local melt pressure and temperature on the micro pattern replication.

  • PDF

A Study on the Filling Imbalance in a Geometrically Balanced Injection Mold (기하학적 균형을 갖춘 금형에서 발생하는 성형품의 충전 불균형에 관한 연구)

  • 구양;김병탁;정영득;한성렬;한규택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.931-937
    • /
    • 2004
  • Simultaneous filling is a goal in plastic injection mold that has multi cavities. The moldings which have not been filled at the same time have undesired faults such as dimension inaccuracy, residual stress, law mechanical strength, etc. The best way to simultaneous fill is to be injected in a geometrically balanced runner system. In a general processing, however, in balanced runner system mold, filling imbalance would be observed in cavities. These phenomena result from molten polymer's characteristics and circumstances in balanced runner. In this study, the degree of filling imbalance (DFI) was defined for showing rate of filling imbalance in geometrically balanced injection mold that has 8 cavities. Before the main experiment, an injection molding simulation was conducted to know a pattern of filling imbalance with Moldflow software. There were somewhat differences between results of experiment and simulation about the filling imbalance. The reason for the difference was that the software have not concerned about a situation in a real flow channel. It was also investigated how the injection speed affected on filling imbalance in the experiment.