• Title/Summary/Keyword: Read Range

Search Result 158, Processing Time 0.029 seconds

Dual-Sensitivity Mode CMOS Image Sensor for Wide Dynamic Range Using Column Capacitors

  • Lee, Sanggwon;Bae, Myunghan;Choi, Byoung-Soo;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.85-90
    • /
    • 2017
  • A wide dynamic range (WDR) CMOS image sensor (CIS) was developed with a specialized readout architecture for realizing high-sensitivity (HS) and low-sensitivity (LS) reading modes. The proposed pixel is basically a three-transistor (3T) active pixel sensor (APS) structure with an additional transistor. In the developed WDR CIS, only one mode between the HS mode for relatively weak light intensity and the LS mode for the strong light intensity is activated by an external controlling signal, and then the selected signal is read through each column-parallel readout circuit. The LS mode is implemented with the column capacitors and a feedback structure for adjusting column capacitor size. In particular, the feedback circuit makes it possible to change the column node capacitance automatically by using the incident light intensity. As a result, the proposed CIS achieved a wide dynamic range of 94 dB by synthesizing output signals from both modes. The prototype CIS is implemented with $0.18-{\mu}m$ 1-poly 6-metal (1P6M) standard CMOS technology, and the number of effective pixels is 176 (H) ${\times}$ 144 (V).

Design of an EEPROM for a MCU with the Wide Voltage Range

  • Kim, Du-Hwi;Jang, Ji-Hye;Jin, Liyan;Ha, Pan-Bong;Kim, Young-Hee
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.4
    • /
    • pp.316-324
    • /
    • 2010
  • In this paper, we design a 256 kbits EEPROM for a MCU (Microcontroller unit) with the wide voltage range of 1.8 V to 5.5 V. The memory space of the EEPROM is separated into a program and data region. An option memory region is added for storing user IDs, serial numbers and so forth. By making HPWs (High-voltage P-wells) of EEPROM cell arrays with the same bias voltages in accordance with the operation modes shared in a double word unit, we can reduce the HPW-to-HPW space by a half and hence the area of the EEPROM cell arrays by 9.1 percent. Also, we propose a page buffer circuit reducing a test time, and a write-verify-read mode securing a reliability of the EEPROM. Furthermore, we propose a DC-DC converter that can be applied to a MCU with the wide voltage range. Finally, we come up with a method of obtaining the oscillation period of a charge pump. The layout size of the designed 256 kbits EEPROM IP with MagnaChip's 0.18 ${\mu}m$ EEPROM process is $1581.55{\mu}m{\times}792.00{\mu}m$.

A Study on the RF Shower System to Extend Interrogating Range for the Low Power RFID Reader System (저출력 RFID 시스템에서 인식거리 확대를 위한 전력 공급용 RF Shower 시스템)

  • Jung, Jin-Wook;Bae, Jae-Hyun;Oh, Ha-Ryoung;Seong, Yeong-Rak;Song, Ho-Jun;Jang, Byeong-Jun;Choi, Kyung;Lee, Jung-Suk;Lee, Hong-Bae;Lee, Hak-Yong;Kim, Jong-Min;Shin, Jae-Cheol;Park, Jun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.526-533
    • /
    • 2006
  • In this paper, we presented the synchronization module between RF shower system and RFID Reader to extend interrogating range on Mobile RFID system, Costas Loop and FPLL(Frequency/phase Lock Loop) were used. We achieved compromised range of 3MHz locking frequency, 1ms locking time and figured out remarkable Hopping frequency of the Reader. The prototype of the new designed RFID system has been tested with ISO18000-6 type-B Tag. The read range between designed RFID Reader and Tag has been measured, it increased triple times by adjusting the Shower system output level.

An aerodynamic and acoustic characteristics of Clear Speech in patients with Parkinson's disease (파킨슨 환자의 클리어 스피치 전후 음향학적 공기역학적 특성)

  • Shin, Hee Baek;Ko, Do-Heung
    • Phonetics and Speech Sciences
    • /
    • v.9 no.3
    • /
    • pp.67-74
    • /
    • 2017
  • An increase in speech intelligibility has been found in Clear Speech compared to conversational speech. Clear Speech is defined by decreased articulation rates and increased frequency and length of pauses. The objective of the present study was to investigate improvement in immediate speech intelligibility in 10 patients with Parkinson's disease (age range: 46 to 75 years) using Clear Speech. This experiment has been performed using the Phonatory Aerodynamic System 6600 after the participants read the first sentence of a Sanchaek passage and the "List for Adults 1" in the Sentence Recognition Test (SRT) using casual speech and Clear Speech. Acoustic and aerodynamic parameters that affect speech intelligibility were measured, including mean F0, F0 range, intensity, speaking rate, mean airflow rate, and respiratory rate. In the Sanchaek passage, use of Clear Speech resulted in significant differences in mean F0, F0 range, speaking rate, and respiratory rate, compared with the use of casual speech. In the SRT list, significant differences were seen in mean F0, F0 range, and speaking rate. Based on these findings, it is claimed that speech intelligibility can be affected by adjusting breathing and tone in Clear Speech. Future studies should identify the benefits of Clear Speech through auditory-perceptual studies and evaluate programs that use Clear Speech to increase intelligibility.

The relationship between fluency levels and suprasegmentals according to the sentence types in the English read speech by Korean middle school English learners (한국 중학생의 영어 읽기 발화에서 문장유형에 따른 유창성 등급과 초분절 요소의 관계)

  • Kim, Hwa-Young
    • Phonetics and Speech Sciences
    • /
    • v.14 no.3
    • /
    • pp.51-66
    • /
    • 2022
  • This study aims to help Korean English learners to learn English pronunciation by revealing which suprasegmentals affect the implementation of English sentences closer to native English speakers when they read English sentences. To this end, Korean middle school English learners were selected as subjects and research data were gathered through sentence types (declarative, interrogative, imperative, and exclamative), as well as syllables. Speech rate, pause frequency, pause duration, F0 range, and rhythm among suprasegmentals were used for analysis of these English sentence utterances. Mean analysis, correlation analysis, and regression analysis were performed. The results showed that speech rate, pause frequency, pause duration, and F0 range affected the evaluation of fluency levels. In the regression analysis between all suprasegmentals and fluency levels, the suprasegmentals that most affected fluency levels were speech rate and F0 range. Rhythm had no meaningful relation with fluency levels. Therefore, when teaching English pronunciation, it is necessary to teach students to increase their speech rate and F0 range. In addition, students should be trained to reduce both the number and the duration of pauses during utterance to improve their fluency. It is noteworthy that of the four sentence types, exclamative sentences were produced with faster speech rate, fewer pauses, shorter pause duration, and higher rhythm values.

LABORATORY TEST OF CCD #1 IN BOAO (보현산 천문대 1번 CCD카메라의 실험실 테스트)

  • Park, Byeong-Gon;Cheon, Mu-Yeong;Kim, Seung-Ri
    • Publications of The Korean Astronomical Society
    • /
    • v.10 no.1
    • /
    • pp.67-78
    • /
    • 1995
  • An introduction to the first CCD camera system in Bohyunsan Optica1 Astronomy Observatory(CCD#l) is presented. The CCD camera adopts modular dewar design of IfA(Institute for Astronomy at Hawaii University) and SDSU(San Diego State University) general purpose CCD controller. The user interface is based on IfA design of easy-to-use QUI program running on the NeXT workstation. The characteristics of the CCD#l including Gain, Charge Transfer Efficiency, rms Read-Out Noise, Linearity and Dynamic range is tested and discussed. The CCD#l shows 6.4 electrons RON and gain of 3.49 electrons per ADU, and the optimization resulted in about 27 seconds readout time guaranteeing charge transfer efficiency of 0.99999 for both direction. Linearity test shows that non-linear coefficient is $6{\times}10^{-7}$ in the range of 0 to 30,000 ADU.

  • PDF

Beta Gamma Survey Meter (베타 및 감마선 계측용 서어베이 미터)

  • 박인용;이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 1971
  • A survey meter which is used a G-M counter sensitive to beta and gamma radiation is studied. This device is completely transistorized, operated with battery, and can be read directly the 3 full-scale meter range: 2.5, 25 and 250 MR/HR respectively. The collector-coupled monostabel multivibrator consisting of a counting-rate meter circuit, and the astable blocking oscillator consisting of a dc-de converter for power supply are analyzed and derived the design dquations. To improve the resolving time of the G-M counter the device is designed to be triggered by low pulse in the order of 0.5v.

  • PDF

Implementation of a portable telemetry system based on wavelet transform. (웨이블릿 알고리즘을 적용한 휴대용 텔레미트리 시스템)

  • 박차훈;서희돈
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.113-116
    • /
    • 2000
  • In this paper presents the portable wireless ECG data detection and diagnosis system based on discreet wavelet transform. An algorithm based on wavelet transform suitable for real time implementation has been developed in order to detect ECG characteristics. In particular, QRS complex, S and T waves may be distinguished form noise, baseline drift or artifacts. Proposed telemetry system that a transmitting media using radio frequency(RF) for the middle range measurement of the physiological signals and receiving media using optical for electromagnetic interference problem. A standard hi-directional serial communication interface between the telemetry system and a personal computer or laptop, allows read-time controlling, diagnosing and monitoring of system. A portable telemetry system within a size. of 65${\times}$125${\times}$45mm consists of three parts: a digital signal processing part for physiological signal detect or diagnose, RF transmitter for data transfer and a optical receiver for command receive. Advantages of proposed telemetry system is wireless middle range(50m) FM transmission, reduce electromagnetic interference to a minimum. which enables a comfortable diagnosis system at home.

  • PDF

Preference and Readability of Hangul Fonts in the Presbyopic Age (노안 연령에서 한글서체의 선호도와 가독성 평가)

  • Jeung, Shinhae;Son, Jeong-Sik;Hwang, Hae-Young;Kim, Seong Kun;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.149-156
    • /
    • 2013
  • Purpose: The aim of this study was to determine a suitable type and size of Hangul fonts for printed materials in the presbyopic age. Methods: Based on the most common Hangul fonts used today, three types of fonts were used Hamchrombatang, Sinmoonmyungjo and Sinmyungjo at small font sizes in the range 9-11 point (pt). Subjects were 101 volunteers aged 41 through 85 years. Near visual acuity (VA) was corrected to read VA 0.5 at 40 cm after distance correction. The subjects were asked to read words containing 88 characters in 10 pt after a question about preference. Readability was assessed by reading rate that was calculated as the number of words read correctly in one minute (words per minute, wpm). Results: The most preferred font type was Simmyungjo at small font sizes. Although preferred font sizes were different in each font type, Sinmyungjo was generally preferred at 10 pt more than other fonts. Hamchrombatang and Sinmyungjo were read significantly faster than Sinmoonmyungjo. There was a weak negative relationship between readability and age in Sinmyungjo. In comparing between the top 10% and the bottom 10% group sorted by reading rate, the top group showed lower average age and addition than the bottom group, however there were no significant differences in reading rate among the fonts. Conclusions: Although increasing age tends to be low in readability for Sinmyungjo, in the light of preferred font and readability, it is recommended to use a 10 pt Sinmyungjo font in printed materials for the presbyopic age.

A Range-Free Localization Method using an RFID System -Applied to a Library Book Location System- (RFID 시스템을 이용한 거리 비종속 위치추정기법 -도서위치추정을 중심으로-)

  • Choi, Jung-Wook;Oh, Dong-Ik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.559-569
    • /
    • 2010
  • We propose an RFID system based on range-free localization method. This method recognizes pre-determined reference tags first, and then checks within which reference tag the target tag is placed closest. It estimates target tag's position relative to the reference tag's position. We use Aging Counter to estimate the distance between reference and target tags using the read ratio of RFID tags. Practicality of the proposed method is verified by applying it to a library book locating system.