• Title/Summary/Keyword: Reactor safety

Search Result 1,268, Processing Time 0.028 seconds

The Construction Work Completion of the Fuel Test Loop (핵연료 노내조사시험설비 설치공사 완료)

  • Park, Kook-Nam;Lee, Chung-Young;Chi, Dae-Young;Park, Su-Ki;Shim, Bong-Sik;Ahn, Sung-Ho;Kim, Hark-Rho;Lee, Jong-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.291-295
    • /
    • 2007
  • FTL(Fuel Test Loop) is a facility that confirms performance of nuclear fuel at a similar irradiation condition with that of nuclear power plant. FTL consists of In-Pile Test Section (IPS) and Out-Pile System (OPS). FTL construction work began on August, 2006 and ended on March, 2007. During Construction, ensuring the worker's safety was the top priority and installation of the FTL without hampering the integrity of the HANARO was the next one. Task Force Team was organized to do a construction systematically and the communication between members of the task force team was done through the CoP(community of Practice) notice board provided by the Institute. The installation works were done successfully overcoming the difficulties such as on the limited space, on the radiation hazard inside the reactor pool, and finally on the shortening of the shut down period of the HANARO. Without a sweet of the workers of the participating company of HEC(Hyundae Engineering Co, Ltd), HDEC(HyunDai Engineering & Construction Co. Ltd), equipment manufacturer, and the task force team, it is not possible to install the FTL facility within the planned shutdown period. The Commissioning of the FTL is on due to check the function and the performance of the equipment and the overall system as well. The FTL shall start operation with high burn up test fuels in early 2008 if the commissioning and licensing progress on schedule.

  • PDF

Effects of Expanding Methods on Residual Stress of Expansion Transition Area in Steam Generator Tube of Nuclear Power Plants (원전 증기발생기 전열관 확관법이 확관부위 잔류응력에 미치는 영향)

  • Kim, Young Kyu;Song, Myung Ho
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.362-372
    • /
    • 2012
  • The steam generator tubes of nuclear power plants are pressure boundaries, and if tubes are leaked, the coolant with the radioactive materials was flowed out from the primary system to the secondary system and polluted the plant and the air. Recently most crack defects of tubes are stress corrosion cracks and these defects are located in expansion transition area, sludge pile-up region, and U-bend area. The most effective one of crack initiation factors in expansion transition area and U-bend area is the residual stress. According to the experiences of Korea standard nuclear plants(Optimized Power Reactor-1000), they had the stress corrosion cracks at the tube expansion transition area in early operating stage and especially lots of circumferential cracks were occurred. Therefore in this study, the distributions and conditions of residual stresses by tube expansion methods were compared and the dominant reason of a specific direction was examined.

Stress Analysis of Expansion Transition Area in Steam Generator Tube of Optimized Power Reactor-1000 (한국표준형원전 증기발생기 전열관 확관부위의 응력해석)

  • Kim, Young Kyu;Song, Myung Ho;Yoo, One
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.148-155
    • /
    • 2013
  • The steam generators of OPR-1000 plants have Alloy 600 and Alloy 690 as the tube material and its tube expansion method is the explosive expansion method. According to the experience of these plants, circumferential cracks were largely occurred in steam generator tubes expanded by the explosive expansion method and their locations were the outer surface of tube expansion transition region surrounding with piled-up sludge. But even though tubes have the same conditions, tubes with the hydraulic expansion method shows the prevail trend of axial cracks compared to circumferential cracks. Therefore in this study, in order to identify the difference of such phenomena as above, configurations of tube and tubesheet were modeled and at operating conditions, stress values applied in the tube expansion transition area in accordance with tube expansion methods were calculated by using computational program and the direction and the predominance of cracks were evaluated.

Design and Simulation of Fluidized Bed System for Waste Propellant Treatment by Computational Fluid Dynamics (폐 추진제 소각을 위한 유동층 반응기 설계 및 CFD 공정 모사)

  • Lee, Jiheon;Lee, Inkyu;Kim, Hyunsoo;Park, Jungsoo;Oh, Min;Moon, Il
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.84-89
    • /
    • 2018
  • Recently, many studies have focused on the explosive waste treatment in terms of the safety and environmental pollution. A combustion process using fluidized bed incinerator has several profits : continuous process, low pollutive gases such as NOx, and high process efficiency. This study focused on the design of the propellant combustion reactor by using computational fluid dynamics(CFD) simulation technique. As a result, the reactions are successfully simulated in cylindrical incinerator, and. The study will influence to the research about treatment of explosive wastes.

A Formal Verification Technique for PLC Programs Implemented with Function Block Diagrams (함수 블록 다이어그램으로 구현된 PLC 프로그램에 대한 정형 검증 기법)

  • Jee, Eun-Kyoung;Jeon, Seung-Jae;Cha, Sung-Deok
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.3
    • /
    • pp.211-215
    • /
    • 2009
  • As Programmable Logic Controllers (PLCs) are increasingly used to implement safety critical systems such as nuclear instrumentation & control system, formal verification for PLC based programs is becoming essential. This paper proposes a formal verification technique for PLC program implemented with function block diagram (FBD). In order to verify an FBD program, we translate an FBD program into a Verilog model and perform model checking using SMV model checker We developed a tool, FBD Verifier, which translates FBD programs into Verilog models automatically and supports efficient and intuitive visual analysis of a counterexample. With the proposed approach and the tool, we verified large FBD programs implementing reactor protection system of Korea Nuclear Instrumentation and Control System R&D Center (KNICS) successfully.

Thermodynamic Analysis of Vapor Explosion Phenomena (증기폭발 현상의 열역학적 해석)

  • Bang, Kwang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.265-275
    • /
    • 1993
  • A vapor explosion has been a concern in nuclear reactor safety due to its potential for a destructive mechanical energy release. In order to properly assess the hazard of a vapor explosion, it is necessary to accurately estimate the conversion efficiency of the thermal energy to mechanical energy. In the absence of a complete model to determine the explosive energy yield, one may have to rely on a simpler upper bound estimate such as a thermodynamic model. This paper discusses various thermodynamic models and presents a clarification of each model in their mathematical formulation and the thermodynamic work conversion. It is shown that the work release in the shock adiabatic model of Board and Hall is essentially equal to that of Hicks-Menzies thermodynamic model. The effect of coolant void fraction on the explosion efficiency is also predicted based on these thermodynamic models. Finally, the Hicks-Menzies model is modified to account for the chemical reaction between a metallic fuel and water and the resultant effects on the explosion expansion work are discussed.

  • PDF

The Effect of Tributary Pipe Breaks on the Core Support Barrel Shell Responses (분기관파단이 노심지지배럴의 쉘응답에 미치는 영향)

  • Jhung, Myung-Jo;Hwan, Won-Gul
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.204-214
    • /
    • 1993
  • Work on fracture mechanics has provided a technical basis for elimination of main coolant loop double ended guillotine breaks from the structural design basis of reactor coolant system. Without main coolant loop pipe breaks, the tributary pipe breaks must be considered as design bases until further fracture mechanics work could eliminate some of these breaks from design consideration. This paper determines the core support barrel shell responses for the 3 inch pressurizer spray line nozzle break which is expected to be the only inlet break remaining in the primary side after leak-before-break evaluation is extended to smaller size pipes in the near future. The responses are compared with those due to 14 inch safety injection nozzle break and main coolant loop pipe break. The results show that, when the leak-before-break concept is applied to the primary side piping systems with a diameter of 10 inches or over, the core support barrel shell responses due to pipe breaks in the primary side are negligible for the faulted condition design.

  • PDF

Investigating the effects of confining pressure on graphite material failure modes and strength criteria

  • Yi, Yanan;Liu, Guangyan;Xing, Tongzhen;Lin, Guang;Sun, Libin;Shi, Li;Ma, Shaopeng
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1571-1578
    • /
    • 2020
  • As a critical material in very/high-temperature gas-cooled reactors, graphite material directly affects the safety of the reactor core structures. Owing to the complex structures of graphite material in reactors, the material typically undergoes complex stress states. It is, therefore, necessary to study its mechanical properties, failure modes, and strength criteria under complex stress states so as to provide guidance for the core structure design. In this study, compressive failure tests were performed for graphite material under the condition of different confining pressures, and the effects of confining pressure on the triaxial compressive strength and Young's modulus of graphite material were studied. More specifically, graphite material based on the fracture surfaces and fracture angles, the graphite specimens were found to exhibit four types of failure modes, i.e., tension failure, shear-tension failure, tension-shear failure and shear failure, with increasing confining pressure. In addition, the Mohr strength envelope of the graphite material was obtained, and different strength criteria were compared. It showed that the parabolic Mohr-Coulomb criterion is more suitable for the strength evaluation for the graphite material.

Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes (구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수)

  • Eem, Seung-Hyun;Choi, In-Kil;Jeon, Bub-Gyu;Kwag, Shinyoung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.

Assessment of Relative Importance to the Early Effect of Released Radionuclides During Nuclear Power Plant Accident (원전 사고시 방출핵종의 조기 영향에 대한 상대적 중요도 평가)

  • Moon, Kwang-Nam;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.78-87
    • /
    • 1988
  • This article suggests the radionuclides which should be considered more important to the offsite consequence assesment during a nuclear power plant accident. For this purpose, the relative importance to the early health effects of released radionuclides on the major organs during the accident is estimated under the assumption of the same release fraction. The inventories of the 25 elements, 54 nuclides selected in the Reactor Safety Study are calculated by ORIGEN 2 code. The organs of interest in the estimation are G. I. track, bone marrow, thyroid and lung. The result shows the relative potential importance of radionuclides as follows: For G.I. track, Np, Ce, Ru, Y, and Zr are of importance in sequence, Np, I, La, Sr, Ba for bone marrow, I and Te for thyroid, Cm, Ce, Ru, Pu, Zr for lung. In addition to iodine and noble gases, therefore, the potential contribution of those nuclides listed above to the offsite consequences should not be overlooked for some accidents of particular sequence.

  • PDF