• Title/Summary/Keyword: Reactive System

Search Result 2,076, Processing Time 0.043 seconds

Effects of Reactive Diluents on the Electrical Insulation Breakdown Strength and Mechanical Properties in an Epoxy System

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.199-202
    • /
    • 2013
  • In order to study the effect of reactive diluents on the electrical insulation breakdown strength and mechanical properties of, a polyglycol and an aliphatic epoxy were individually introduced to an epoxy system. Reactive diluents were used in order to decrease the viscosity of the epoxy system; polyglycol acted as a flexibilizer and 1,4-butanediol diglycidyl ether (BDGE) acted as an aliphatic epoxy, which then acted as a chain extender after curing reaction. The ac electrical breakdown strength was estimated in sphere-to-sphere electrodes and the electrical breakdown strength was estimated by Weibull statistical analysis. The scale parameters of the electrical breakdown strengths for the epoxy resin, epoxy-polyglycol, and epoxy-BDGE were 45.0, 46.2, and 45.1 kV/mm, respectively. The flexural and tensile strengths for epoxy-BDGE were lower than those of the epoxy resin and those for epoxy-polyglycol were lower than those of the epoxy resin.

EMTP Simulation for the Dynamic Analysis of a STATCOM-Shunts-OLTC Coordination in Substation (변전소 조상 설비간의 협조 제어를 위한 EMTP 과도해석모형 개발)

  • Jeong, Ki-Seok;Baek, Young-Sik;Park, Ji-Ho;Chang, Byung-Hoon;Lee, Hyun-Chul;Lee, Geun-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.237_238
    • /
    • 2009
  • This paper proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC. Voltage/Reactive power control has various difficult aspects to control because of analysis and system dynamics error. This coordinative control method suggests practical algorithm regarding system voltage and reactive power status which is easy to implement in substation basis. In normal status, STATCOM-Shunts-OLTC are in operation. The proposed algorithm is tested and verified in EMTP/RV. And this is expected to be applied to control multiple reactive power devices combined with SCADA/EMS system.

  • PDF

Intervening Firing Method and Passive Filter Design for Harmonic Elimination and Reactive Power Compensation in Three-Phase Thyristor Phase-Controlled Converters Supplying a DC Motor

  • Pattanapongchai, Artite;Wongtongdee, Surached W.;Laohasongkram, Piphat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.813-816
    • /
    • 2005
  • This paper presents a method for harmonic elimination and reactive power compensation using an intervening firing method and passive power filter with is suitable to compensate rapidly changing loads and reactive power. The proliferation of three-phase thyristor phase-controlled converter of DC motor drives into a power system has the potential to increase the harmonic levels in the power system. The design procedure of an intervening firing method and passive power filter capable of reducing the voltage and current harmonics produced by converter supplied from a source having internal large inductive impedance is offered. The analysis uses the or CAD PSpice to model three-phase thyristor phase-controlled converter of DC motor drives as well as the system.

  • PDF

Real and Reactive Power Control of Battery Energy Storage System (전지전력저장시스템의 유효 및 무효전력제어)

  • Kim, Dae-Won;Choi, Joon-Ho;Jung, Sung-Kyo;Kim, Jae-Chul;Choi, Byoung-Su
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1189-1191
    • /
    • 1999
  • This paper deals with the real and reactive power control of BESS(Battery Energy H Storage System) interconnected to power system. The real and reactive power control of proposed customer side BESS are performed by controlling the amplitude and the phase of inverter output voltage via power flow equation. Also in order to control the amplitude and phase of output voltage of proposed BESS, single-pulse width control method is used. The BESS and controller is implemented and the active and reactive power control is simulated by using the PSCAD/EMTDC simulation program.

  • PDF

Reactive Power Compensation of Load Adated STATCOM System (STATCOM 시스템을 적용한 부하의 무효전력 보상)

  • Lee, Hwa-Su;Lee, Eun-Woong;Kim, Yong-Heon;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1027-1029
    • /
    • 2003
  • STATCOM which is connected the load parrallel with capacitor. is the reactive power compensation device. In this paper. appling the PSIM(POWERSIM) software to STATCOM system. it is simulated the reactive power compensation of balancing load. And, setting a thoroughly going over it's results. we confirmed the function propriety of developed STATCOM system. So, it will be applied the reactive power compensation experimentation of the developing 30kVA STATCOM at our laboratory.

  • PDF

Algorithm of Extended Current Synchronous Detection for Active Power Filters (능동전력필터를 위한 확장된 전류 동기 검출 알고리즘)

  • 정영국
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.111-114
    • /
    • 2000
  • Harmonics and fundamental reactive power of nonlinear loads in serious unbalanced power condition are compensated by current synchronous detection(CSD) theory which is also acceptable for single phase power system, but the CSD theory is not suitable any more in case of controlled independently harmonics and reactive component. Therefore a new algorithm the extended current synchronous detection (ECSD)theory for a three phase active power filter based on decomposition of fundamental reactive distorted components is proposed in this paper. The proposed ECSD theory is simulated and tested comparison with a few power theories under asymmtrical condition in power system.

  • PDF

Design Parameter Analysis for a Planar Type Reactive Ion Etcher (평판형 반응성 이온 식각기의 설계변수 분석)

  • 강봉구;박성호;전영진
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.11
    • /
    • pp.1658-1665
    • /
    • 1989
  • Reactor design considerations over several critical parameters for a planar type reactive ion etcher are given. The etch uniformity is taken as a principal design constraint. The characteristics of economicaly available vacuum pumping system are taken as practical design constraints. A set of theoretical conditions on the chamber geometry and on the gas delivery and vacuum system, that satisfy the design constraints, are derived from basic properties of RF glow discharge and gas dynamics. The theoretical results are applied to decide design parameters of a practical single-wafer-per-chamber planar type reactive ion etching machine.

  • PDF

Hydrogen Generation by Electrical Discharge through Metal/Water System

  • G. J. Kang;S. Y. Cha;Lee, W. M.;Park, Y. M.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.111-114
    • /
    • 1996
  • Hydrogen generation by dissociation of water is described. The major force for the dissociation comes from the oxidation potential of the reactive metal reacting with water whereas the minor role is played by electrical discharge which helps sustain the reaction. A premixed reactive metal/water system undergoes a fast hydrogen generation upon the ignition by an electrical pulse. In another method the reactive metal can be fed into the discharge. Some characteristics of the methods are discussed.

  • PDF

Effect of Reactive Diluents on the AC Electrical Treeing in Epoxy/Nanosilicate Systems

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.2
    • /
    • pp.77-80
    • /
    • 2014
  • The effect of reactive diluents on the ac electrical treeing in epoxy/nanosilicate systems was studied, in a needle-plate electrode geometry. Diglycidyl ether of bisphenol A (DGEBA) type epoxy was used as a base resin, and layered silicate was used as a nano-sized filler. Polyglycol (PG) or 1,4-butanediol diglycidyl ether (BDGE) was introduced as a reactive diluent to the DGEBA/nanosilicate system, in order to decrease the viscosity of the nanocomposite system. PG acted as a flexibilizer, and BDGE acted as a chain extender, after the curing reaction. To measure the treeing propagation rate, a constant alternating current (ac) of 10 kV/4.2 mm (60 Hz) was applied to the specimen, in a needle-plate electrode arrangement, at $30^{\circ}C$ of insulating oil bath. When 10 kV/4.2 mm (60 Hz) was applied, the treeing propagate rate in the DGEBA system was $1.10{\times}10^{-3}$ mm/min, and that in the DGEBA/PG system was $1.05{\times}10^{-3}$ mm/min. As 1.5 wt% of nanosilicate was added to the DGEGA/PG system, the propagation rate was $0.33{\times}10^{-3}$ mm/min. This meant that the nano-sized layered silicates would act as good barriers to treeing propagation. The effect of chlorine content was also studied, and it was found that chlorine had a bad effect on the electrical insulation property of the epoxy system.

A study for the system voltage and reactive power control (계통전압.무효전력 제어에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.14 no.3
    • /
    • pp.10-17
    • /
    • 1965
  • This paper presents a method of the voltage-reactive power control in the long and short range operations and introduces a conception, "optimum control pattern." The optimum control pattern, aiming at the over-all system control, is defined as the optimum voltage distribution which minimizes the system operating cost under the conditions that the specified power be supplied and the system voltage be kept within the specified bounds. The following procedure was adopted to obtain this optimum pattern. In the first place, a power system was divided into three blocks, namely, load, substation and generator. Lagrange's, multiplier method is applied to each block in turn, paying attention only at the operating voltage distribution. Phase angles at each bus are then modified so that the continuity of active power is maintained. This procedure may be called "block relaxation method with Lagrange's multipliers." In a long range operation, this control pattern determines the optimum installation capacity of reactive power sources. In a short range operation, it also gives the reference state of real time control and the optimum switching capacity of reactive power souces. The real time control problem is also studied from the standpoint of cooperation of control devices such as generators, shunt capacitors, shunt reactors and ratio load controllers. A proposal for the real time control will contribute to the automation of power system operation in the near future. in the near future.

  • PDF