• Title/Summary/Keyword: Reactive Component

Search Result 281, Processing Time 0.023 seconds

능동전력필터를 위한 확장된 전류 동기 검출 알고리즘 (Algorithm of Extended Current Synchronous Detection for Active Power Filters)

  • 정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.111-114
    • /
    • 2000
  • Harmonics and fundamental reactive power of nonlinear loads in serious unbalanced power condition are compensated by current synchronous detection(CSD) theory which is also acceptable for single phase power system, but the CSD theory is not suitable any more in case of controlled independently harmonics and reactive component. Therefore a new algorithm the extended current synchronous detection (ECSD)theory for a three phase active power filter based on decomposition of fundamental reactive distorted components is proposed in this paper. The proposed ECSD theory is simulated and tested comparison with a few power theories under asymmtrical condition in power system.

  • PDF

전력용 MOSFET Inverter에 의한 무방전력보상에 관한 연구 (A Study on the Compensation of Reactive Power by Power MOSFET INVERTER)

  • 이계호;김동필
    • 대한전기학회논문지
    • /
    • 제36권3호
    • /
    • pp.163-170
    • /
    • 1987
  • It is known that reactive component of AC power in the power system gives no energy to outside and cuses enlargiment of power apparatus, voltage fluctuation and unstability of power system. The power conversion system and control system which are composed of power semiconductor devices such as tyristor, transistor, GTO and so on have been appeared as new sources of reactive power. So the cmpensation of reactive power in power semiconductor systems is one of impending problem on the point of energy conservation and inprovement of power factor. This paper treates the fundamental review of the current type power compensation system that compensates the reactive power by MOSFET inverter. This inverter detects not only the reactive power of fundamental wave but also that of all harmoics created in the power semiconductor system and is scheduled to control by sampled value.

  • PDF

화학 플랜트에서의 비상발전기 용량선정 방안(PG3)에 관한 연구 (Study on Emergency Generator Capacity Selection(PG3) in the Chemical Plant)

  • 이승재;조만영;김세용;김은태;강병욱;박한민;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.55-60
    • /
    • 2015
  • PG and RG methods are widely known method for calculating the capacity of the emergency generator in construction electrical installation. PG and RG methods are mainly used as a saving a life, fire protection, fire fighting in construction. Because no long distance between the emergency generator and electric motor feeder, the relatively small motor power in construction electrical installation, the capacity of generator in PG and RG methods are little problem of voltage and reactive power of generator. However in many cases the application of the PG and RG method is difficult in the Chemical Plant because it is long distance between the generator and the motor Feeder and motor capacity is very large. Motor starting power factor is about 0.2 lagging power factor and motor starting current is about 6times during motor staring. Also Most of the staring current component is a reactive power component. therefore, it is many cases that lack of reactive power and excess of allowable voltage drop limit and After selection of emergency diesel generator, problems happen during motor starting. Therefore, to be selection of effective emergency generator, active generator power, reactive power and the required reactive power during large motor starting should be considered in chemical plant. It is also required of the verification process through simulation because hand calculation is very difficult considering study cases.

An ANN Controlled Three-Phase Auto-Tuned Passive Filter for Harmonic and Reactive Power Compensation

  • Sindhu, M.R.;Nair, Manjula;Nambiar, T.N.P.
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.403-409
    • /
    • 2009
  • Automatically tuned passive filters can improve power quality to a great extent in power systems. A novel three-phase shunt auto-tuned filter is designed to effectively compensate source current harmonics and to provide reactive power required by the non-linear load, which draws a highly reactive, harmonic-rich current from the supply. An artificial neural network (ANN) based controller selects filter component values in accordance with reactive power requirement and harmonic compensation. Traditional passive filters are permanently connected to the system and draw large amounts of source current even under light load conditions. By using auto-tuned filters, the passive filter components can be controlled according to load variations and, hence, draw only required source currents. The selection is done by the ANN with the help of a properly tuned knowledge base to provide instantaneous compensation using a digital controller.

전력시장 체제에서 발전기 무효전력 출력의 가치 평가에 관한 연구 (Evaluation of Generator's Reactive Power in Deregulated Electricity Market)

  • 나춘수;박종근;한태경;김문겸;김도한;이상호;이상성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.869-871
    • /
    • 2005
  • As deregulated electricity markets are being implemented in different countries, the remuneration of reactive power which contribute to ancillary services is one of the key issues, so it is necessary to evaluate the generator's reactive. In this paper, we focus on the evaluation of reactive power which contributes to reactive power balance. The idea is that the main usages of the reactive power of generator can be divided into two components. First one is physically required amounts for transmitting the real power and the second one is the amounts contributed to support the system, that is, to maintain the voltage profiles. In this paper, the second component is used to evaluate the effective amounts of the reactive power contributed to ancillary service.

  • PDF

s-Triazine계 반응성 염료에 관한 연구 (제3보). 2개의 발색단을 포함한 Monofluorotriazine 반응성 염료에 합성 (Studies on the s-Triazinyl Reactive Dyes (III). Synthesis of Dichromophoric Monofluorotriazinyl Reactive Dye)

  • 남계춘;김원태;박상우
    • 대한화학회지
    • /
    • 제27권3호
    • /
    • pp.218-223
    • /
    • 1983
  • 새로운 반응성염료 개발의 일환으로 trifluoro-s-triazine을 반응성분으로 이용하여 한 분자에 2개의 서로 다른 chromophore를 가지는 반응성염료를 합성한 다음, 이의 가수분해속도와 면섬유에 대한 염색성을 조사하였다. 이 염료의 유사 일차 가수분해속도상수, $k_w$는 pH=10.0, 온도 $60{\circ}C$에서 k_w=2.6{\times}10^{-2}min^{-1}$로서 monochlorotriazine 반응성염료보다 높은 값을 보였으며 염착률과 고착율 역시 monochlorotriazine 계 염료보다 우수하였다. 얻어진 반응성 염료는 황색계열로서 수율은 75%였다.

  • PDF

Real Time Implementation of Active Power Filters for Harmonic Suppression and Reactive Power Compensation using dSPACE DS1104

  • Kumar, Seethapathy;Umamaheswari, B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.373-378
    • /
    • 2008
  • In this paper, an Active Power Filter (APF) is implemented using a dSPACE DS1104 processor to compensate harmonics and reactive power produced by nonlinear load. The reference source current is computed based on the measurement of harmonics in the supply voltage and load current. A hysteresis based current controller has been implemented in a DSP processor for injecting the compensating current into the power system, so that APF allows suppression of the harmonics and reactive power component of load current, resulting in a supply current that is purely sinusoidal. Simulation and experimental results of the proposed APF to meet the IEEE-519 standards are presented.

콘크리트용 골재의 알카리-실리카 반응의 함량 최악조건 (An Introduction of Pessimum Program for the Identification of Alkali-Aggregate Reaction)

  • 이상완;김수만;이평석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.363-368
    • /
    • 2000
  • This paper is an introduction of pessimum program for the identification of alkali-silica reaction of alkali-aggregate reaction which is known as one of a major factor of concrete deterioration. A series of gel-pat testing program was undertaken to observe the reactivity of potentially alkali-silica reactive concrete aggregates which were found to be reactive by previous petrographic examination (ASTM C 295). And then a pessimum program was performed in accordance with mortar-bar test method (ASTM C 227) with different percentage of those reactive components included in the fine aggregate source to determine the pessimum quantity. Chert and quartzite were found to be major components of reactive mineral/rock, and the pessimum condition for chert was about 3%, even though the test was performed with up to 25% of the component. In the case of quartzite, however, the mortar-bar expansion appeared to be directly proportional to the amount of quartzite sample with increasing tested quantity up to 35%. Both of the expansion results were well 3 and 6 month specified maximum limitation of 0.05% and of 0.1% respectively.

  • PDF

반응형 음이온화제의 정전기적 인력에 의한 베르베린 색소의 염착성 향상 (Dyeability Improvement of Berberine Colorant by Electrostatic Attractive Force of a Reactive Anionic Agent)

  • 김태경;윤석한;임용진;손영아
    • 한국염색가공학회지
    • /
    • 제15권6호
    • /
    • pp.47-54
    • /
    • 2003
  • To be dyed with cationic Berberine, the cotton fiber was modified with reactive anionic agent. The Berberine, a natural cationic colorant of pure yellow, is the major component of Amur Cork tree extract and also can be employed as a natural antimicrobial agent due to its characteristic of cationic quaternary ammonium salt. By LC/MS analysis, it became obvious that the Berberine was contained in Amur Cork tree extract as a major color component. The adsorption of the Berberine on the cotton fabrics pretreated with the anionic agent was greatly increased comparing to that of untreated fabric. Because the anionic agent was colorless, it did not cause unintended color change of the dyeings. The dyed fabric with the Berberine has strong antimicrobial activity showing 99.5% of reduction of bacteria against Staphylococcu aureus.

조상용량을 고려한 부하모델링 (Component-Based Load Modeling Including Capacitor Banks)

  • 지평식;이종필;임재윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.181-183
    • /
    • 2002
  • Complete load model of the substation not only should include the performances of the load components, but also should take into consideration the core losses of transformers, the line losses and the capacitor banks. In an actual distribution system, the control scheme of capacitor banks are so complex and is difficult to identify actual values for the reactive powers of capacitor banks. This research improves on this drawback by applying component-based modeling method including a capacitor banks in distribution systems. Initial differences between the model results and the actual values for reactive powers are later decreased by the proposed method.

  • PDF