• 제목/요약/키워드: Reaction parameter

검색결과 477건 처리시간 0.022초

연속식 PCR과 BCR에서 pH 변화에 따른 페놀 폐수의 오존처리특성에 관한 연구 (The Characteristics of the Ozonation of phenol wastewater by the variation of pH using the continuous PCR and BCR)

  • 안재동;김민수;김용대;최석규
    • 한국환경보건학회지
    • /
    • 제23권1호
    • /
    • pp.74-80
    • /
    • 1997
  • This study was performed to estimate the ozonation characteristics of phenol wastewater with increasing pH in the continuous packed column reactor (PCR) and the bubble column reactor (BCR). Among various influencing factors that affect phenol on decomposition through the ozonation, pH was chosen as reaction parameter. Upon increasing pH from 3 to 9, the phenol removal efficiency in PCR was improved approximately by 17% while in BCR approximately by 19.2%. The improvements in the phenol removal efficiency by increasing pH caused the enhancements in ozone utilization efficiency reaching almost 100% in PCR at pH 9. In conclusions, ozone has latent power for phenol wastewater treatment, and the performance of PCR was superior to that of BCR in the aspects of phenol removal and ozone utilization efficiency.

  • PDF

비선형 폐 가스 결합특성의 전기적 모델화 (Electrical Modelling of Nonlinear Blood-Gas Reaction)

  • 이준탁;정형환
    • 한국의학물리학회지:의학물리
    • /
    • 제2권2호
    • /
    • pp.175-182
    • /
    • 1991
  • 본 논문은 인공폐의 설계및 임상진단을 위한 허파기능의 연구 및 호흡생리의 요체인 폐모세 혈관내 혈액의 Hb와 가스상 산소의 비선형 결합특성을 규명할 수 있는 새로운 산소포화 모델을 전기적 등가회로에 기초하여 유도하였다. 새로이 유도된 산소포화 모텔은 종래의 모델에 비해 훨씬 간단하고, 광범위한 pH 및 각 생리 parameter 등의 변동에도 정확히 적용될 수 있었을 뿐 아니라, 결합반응과 등가인 2단 및 4단 RC 전기적 등가회로의 Simulation 결과로 부터, Hb 와 산소의 비선형 결합특성은 2단계의 복합 반응으로 취급하는 것이 타당함을 확인하였다.

  • PDF

자기축열식 저 NOx 연소기에서 배가스 재순환이 연소특성에 미치는 영향 (The Effect of Flue-gas Recirculation on Combustion Characteristics of Self Regenerative Low NOx Burner)

  • 강민욱;김종규;동상근;윤영빈
    • 한국연소학회지
    • /
    • 제8권1호
    • /
    • pp.17-24
    • /
    • 2003
  • The conventional regenerative system has a high thermal efficiency as well as energy saving using the high preheated combustion air. in spite of these advantages, it can not avoid high nitric oxide emissions. Recently, flameless combustion has received much attention to solve these problems. In this research, numerical analysis is performed for flow-combustion phenomena in the self regenerative burner. In this analysis we used Fluent 6.0 code. the that is developed for commercial use, Methane gas is used as a fuel and two-step reaction model for methane and Zeldovich mechanism for NO generation are used. the velocity of the preheated combustion air is used as a parameter and we analyze the characteristics of flow-field, temperature distributions and NO emissions. Due to the increased recirculation rate, the maximum temperature of flame is significantly increased and NOx emissions is reduced.

  • PDF

고 표면적-체적 비를 가지는 소형 연소실 환경에서의 연소특성 (Combustion characteristics in small combustion chamber that has high surface to volume ratio)

  • 이대훈;최권형;권세진
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.212-216
    • /
    • 2000
  • Combustion phenomenon in scale-downed combustor is investigated. As the combustor volume decreases surface to volume ratio increases. for increased surface to volume ratio means increased heat loss and this increased heat loss affects reaction in combustion chamber. Plastic mini combustor is made. Stoichiometricaly premixed Hydrogen I air gas is used as fuel. Initial chamber pressure and chamber size are varied and the effects are evaluated. Peak pressure decreases with the decrease in chamber height. As initial chamber pressure decreases peak pressure decreases. And this change is more important than scale down effect till the chamber height of 1mm. With this result and further information following the experiments design parameter for micro engine can be established.

  • PDF

신 열환원 공정에 의한 초미립 티타늄 카바이드 분말 합성 (Synthesis of Ultrafine Titanium Carbide Powder by Novel Thermo-Reduction Process)

  • 이동원;;배정현;김병기
    • 한국분말재료학회지
    • /
    • 제10권6호
    • /
    • pp.390-394
    • /
    • 2003
  • Ultra fine titanium carbide particles were synthesized by novel metallic thermo-reduction process. The vaporized TiC1$_4$+$CCl_4$ gases were reacted with liquid magnesium and the fine titanium carbide particles were then produced by combining the released titanium and carbon atoms. The vacuum treatment was followed to remove the residual phases of MgC1$_2$ and excess Mg. The stoichiometry, microstructure, fixed and carbon contents and lattice parameter were investigated in titanium carbide powders produced in various reaction parameters.

STS 304 발열선 착화기의 열전이 특성 (Thermal Transient Characteristics of Initiator with STS 304 Bridgewire)

  • 윤기은;류병태;최창선
    • 한국추진공학회지
    • /
    • 제10권4호
    • /
    • pp.19-25
    • /
    • 2006
  • STS 304 발열선과 $Zr-KCIO_4$ 기폭화약을 사용한 전기식 착화기에 대한 열전이 특성을 시험하고 Fitted Wire Model로 분석한 결과, 약 $300^{\circ}C$ 부근에서 기폭화약과 관련된 열전이 특성 파라미터가 급격하게 변화되었다. 이 현상은 기폭화약에 사용된 $KCIO_4$의 상변화로 인한 흡열반응에 의해 발생된 것으로 판단된다.

SOLUTION OF THE SUPER BESSEL WAVE EQUATION WITH INTEGRAL PARAMETER m

  • Lee, Nae-Ja;Liu, Chang-Keng
    • 대한수학회보
    • /
    • 제20권2호
    • /
    • pp.99-103
    • /
    • 1983
  • Internal heat generation is one of the insidious conditions affecting the quality of an industrial product after it is cast, coated, molded, forged or laminated. Frequently, the product is pressed into service before the exothermic chemical reactions in the generic material has been completed. The heat liberated from this continuing chemical reaction or the residual deformation from the rheological activities in the materials must be adequately removed or prevented, or the product may be discolored, warped, weakened or even "ignited" spontaneously. Numerous instances of premature structural failures, product-recalls, and/or system-malfunctions have been recorded in recent history. The Coulee Dam was poured with pre-chilled concrete just to negate this freakish encore. It is well-known that concrete (a non-isotropic conducting medium), for instance, takes 28 days to develop its full strength. During this period of curing it is conceivable that the processes of internal heat generation, heat conduction and heat dissipation take place simultaneously inside the medium.he medium.

  • PDF

HSDI 디젤엔진의 연료분사계와 연소현상을 연계한 수치해석 (Coupled Simulation of Common Rail Fuel Injection and Combustion Characteristics in a HSDI Diesel Engine)

  • 이석영;허강열
    • 한국연소학회지
    • /
    • 제15권1호
    • /
    • pp.1-11
    • /
    • 2010
  • In this study, the coupled simulation of fuel injection model and three-dimensional KIVA-3V code was tried to develop an algorism for predicting the effects of varying fuel injection parameter on the characteristics of fuel injection and emissions. The numerical simulations were performed using STAR-CD code in order to calculate the intake air flow, and the combustion characteristics is examined by KIVA-3V code linked with the conditional moment closure(CMC) model to predict mean turbulent reaction rate. Parametric investigation with respect to twelve relevant injection parameters shows that appropriate modification of control chamber orifice diameter, needle valve spring constant and nozzle chamber orifice diameter can significantly reduce NOx and soot emissions. Consequently, it is needed to optimize the fuel injection system to reduce the specific emissions such as NOx and soot.

스태거 배치 페어자석의 지지계(支持系), 안내계(案內系), 비간섭제제(非干涉制制)의 고찰(考察) (A Study of Staggered Magnet Pair Decoupling Control for a Levitation System)

  • 권병일;정전영개
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.84-1-84-4
    • /
    • 1988
  • To obtain both lift and guidance forces, either seperate vertical and horizontal reaction rails with a ssociated magnets may be used, or a pair of magnets each latterally staggered relative lo the rail center line may be empolyed. This paper deals with the latter design, and shows that the heave and sway motions arc decoupled by linearization for small heave and sway displacement and for large sway displacement. However. there are some cowpling factors because of parameter variation nonlinear effects, which are compensated.

  • PDF

고밀도 플라즈마에 의한 (Ba,Sr)$TiO_3$막의 식각특성 연구 (A study on the etching properties of (Ba,Sr)$TiO_3$ film by high density plasma)

  • 김승범;김창일;장의구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.798-800
    • /
    • 1998
  • (Ba,Sr)$TiO_3$ thin films were etched with $Cl_2$/Ar gas mixing ratio in an inductively coupled plasma (ICP) by varying the etching parameter such as f power, do bias voltage, and chamber pressure. The etch rate was $560{\AA}/min$ under Cl_2/(Cl_2+Ar)$ gas mixing ratio of 0.2, rf power of 600 W, do bias voltage of 250 V, and chamber pressure of 5 mTorr, At this time, the selectivity of BST to Pt, $SiO_2$ was respectively 0.52, 0.43. The surface reaction of the etched (Ba,Sr)$TiO_3$ thin films was investigated with X-ray photoelectron spectroscopy (XPS).

  • PDF