• Title/Summary/Keyword: Reaction Board

Search Result 95, Processing Time 0.02 seconds

Synthesis of Sulfonated POF-g-Styrene ion Exchange Fibers by Radiation-Induced Polymerization and Properties of Ammonia Adsorption (방사선 중합에 의한 설폰화 POF-g-Styrene 이온교환 섬유의 합성 및 암모니아 흡착)

  • Cho, In-Hee;Baek, Ki-Wan;Lee, Chang-Soo;Nho, Young-Chang;Yoon, Soo-Kyung;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • In this study, the sulfonated ion exchange fiber was synthesized by $Co^{60}\;{\gamma}-ray$ radiation-induced graft copolymerization. Degree of grafting (DG) increased with increasing the total dose and showed the highest value at 50 v/v% styrene monomer. And also, the degree of sulfonation (DS) increased with increasing the DG and reaction temperature. DS showed the maximum value at 20 min. Ion exchange capacity and swelling ratio of ion exchange fibers increased with increasing the DS and their maximum values were 4.76 meq/g and 23.5%, respectively. Ammonia adsorption increased as increasing the ammonia concentration and ion exchange capacity and remained constant over 10 cycles.

A implementation of system which checks the vehicle oil identification and quantitative gas (자동차 석유 및 정량주유 체크 시스템의 구현)

  • Jeong, Da-Woon;Baek, Sung-Hyun;Jang, Jong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.6
    • /
    • pp.1277-1282
    • /
    • 2011
  • Recently, many car drivers were damaged by gas station which support similar oil product and not quantitative gas. It were expected to increase above-mentioned damages. By using similar oil products, caused damage are working of lubrication in the fuel line, elf-cleaning function, the part of the early deterioration, impure accumulation in the fuel line, toxicity material in exhaust emissions and unidentified chemical reaction. To prevent these damages, proposed system use in-vehicle state data with OBD-II protocol, measure quantitative gas and similar oil. In this paper, there have implemented similar oil identification and quantitative gas system through OBD-II scanner to provide WiFi communcation by using WinCe development Board.

Characteristics of Bio-oil derived from Quercus Acutissima in a Fluidized Bed Pyrolyser (유동층 열분해로에 의하여 생산된 상수리나무 바이오오일의 특성)

  • Lee Sun-Hoon;Eom Min-Seop;Yoo Kyung-Seun;Lee Young-Soo;Kim Nam-Chan;Lee See-Hoon;Lee Jae-Goo;Kim Jae-Ho
    • Resources Recycling
    • /
    • v.15 no.1 s.69
    • /
    • pp.3-11
    • /
    • 2006
  • Fast pyrolysis of Quercus acutissima was carried out in a fluidized bed pyrolyser and then the physicochemical properities of obtained bio-oil were analyzed using GC/MS. The yields of bio-oil of Quercus acutissima and Larix leptolepis from a fluidized bed pyrolyzer were maximized at $350^{\circ}C\;and\;400^{\circ}C$, respectively. This is due to the difference or cellulose content between the two tree species. Above the optimum temperature, the yields of char and oil decreased as the reaction temperature increased, but the yield of gas-phase and water fraction increased. It is concluded that this phenomenon is occured by secondary pyrolysis in the free board. The feeding rate of the sample in a fluidized bed pyrolyser did not affect the yields and composition of products, because of a sufficient mixing between bed materials and sand.

The Effects of Simultaneous Hand Washing by Nurse and Child Before IV Injection (아동과 간호사의 손씻기 프로그램이 정맥주사와 관련한 아동의 불안, 동통과 피부손상에 미치는 효과)

  • Lee, Ae-Ran;Park, Min-Im;Lee, Hyo-Soon;Kim, So-Hyun;Park, Jin-Kyong;Kim, Ji-Soo
    • Child Health Nursing Research
    • /
    • v.14 no.2
    • /
    • pp.129-137
    • /
    • 2008
  • Purpose: To examine the effects on skin injury, pain, and anxiety when nurses and children simultaneous wash their hands before IV injections. Method: A nonequivalent control group, non-synchronized design study was used with 61 children. For a month and a half, children in the experimental group(30) following hand-washing guidelines, washed their hands with nurses before IV insertion. Anxiety and pain were observed and recorded during IV insertion using the Anxiety Reaction Scale and FACES pain scale. After 48-72 hours on IV therapy with an arm-board, skin condition was checked by a research assistant according to guidelines for assessing skin injury developed by the researcher. t-test, ${\chi}^2$-test, Pearson correlation, and Kendall's tau b were used to analyze data with the SPSS program. Results: Children who washed their hands with the nurse before IV insertion showed less pain (p =.021) and skin injury (p <.001) compared to the control group. Conclusion: This finding suggests that simultaneous hand washing by nurse and child before IV injection has a strong effect on skin injury caused by arm-boards used to maintain IV therapy as well as on pain during IV insertion. This program demonstrates an effective intervention to prevent skin injuries in children on IV therapy.

  • PDF

A design and implement vehicle similar oil identification and quantitative gas (자동차 유사석유제품 및 정량주유 판별 시스템의 설계 및 구현)

  • Jeong, Da-Woon;Baek, Sung-Hyun;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.281-284
    • /
    • 2011
  • Recently, many drivers was the damage caused by similar oil product sales and gas station by not using quantitative gas. so, these damages is expected to rise damages by increasing these problem. By using similar oil products, caused damage in the fuel lines' working of lubrication and self-cleaning function for the occurred trouble in the part of the early obsolescence and the accumulation of impurities in the fuel lines, combustion rate due to the difference between retail gasoline engine, the burden of weight, Toxic substances in exhaust emissions, engine oil and unresolved issue is the chemical reaction can occur. to prevent these damages, using the system use in-vehicle state data with OBD-II protocol and measure quantitative gas and similar oil. In this paper, there implement similar oil identification and quantitative gas system through OBD-II scanner to provide WiFi communcation by using WinCe development Board.

  • PDF

Research on the Thermal Comfort Heating Mode Considering Psychological and Physiological Response of Automobile Drivers (운전자의 심리·생리 반응을 고려한 승용차 쾌적 난방 모드에 관한 연구)

  • Kim, Min Soo;Kum, Jong Soo;Park, Jong Il;Kim, Dong Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.149-157
    • /
    • 2018
  • In this research, the psychological and physiological reactions of the driver were measured during winter to evaluate thermal comfort. The experiment was conducted using 3 different cases which are hot air heating, warm-wire seat heating and hot air & warm-wire seat heater operating simultaneously. With regard to psychological reaction, the warm-wire heating mode was the most preferred. The reason is that it is dry in other cases. With regard to EEG response, thermal comfort increased by 37% in warm air mode heating. In addition, when the warm-wire heating mode and the hot air & warm-wire heating mode were simultaneously operated, the thermal comfort continuously increased by between 17% and 20% for 20 minutes after boarding. Under the change of the autonomic nervous system, the thermal stress level increased by 23% after 15 minutes on board in the hot air heating mode and decreased continuously by 13% during the warm-wire seat heating mode. We recommended the hot air heating mode is only used for a short time to raise the inside temperature during the early boarding period and that warm-wire seat heating mode be actively utilized.

A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION (복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고-)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

Polarization Behaviors of SnCu Pb-Free Solder Depending on the P, Ni, Addition (SnCu계 무연솔더의 Ni, P 첨가에 따른 분극거동)

  • Hong Won Sik;Kim Whee Sung;Park Sung Hun;Kim Kwang-Bae
    • Korean Journal of Materials Research
    • /
    • v.15 no.8
    • /
    • pp.528-535
    • /
    • 2005
  • It is inclined to increase that use of hazardous substances such as lead(Pb), mercury (Hg), cadmium(Cd) etc. are prohibited in the electronics according to environmental friendly policies of an advanced nation for protecting environment of earth. As this reasons, many researches for ensuring the reliability were proceeding in Pb free soldering process. n the flux remains on the PCB(printed circuit board) in the soldering process or the electronics exposed to corrosive environment, it becomes the reasons of breakdown or malfunction of the electronics caused by corrosion. Therefore in this studies we researched the polarization and Tafel properties of Sn40Pb and SnCu system solders based on the electrochemical theory. The experimental polarization curves were measured in distilled ionized water and 1 mole $3.5 wt\%$ NaCl electrolyte of $40^{\circ}C$, pH 7.5. Ag/AgCl and graphite were utilized by reference and counter electrodes, respectively. To observe the electrochemical reaction, polarization test was conducted from -250mV to +250mV. From the polarization curves composed of anodic and cathodic curves, we obtained Tafel slop, reversible electrode potential(Ecorr) and exchange current density((cow). In these results, we compared the corrosion rate of SnPb and SnCu solders.

Reliability and validity of pelvic mobility measurement using a cushion sensor in healthy adults

  • Jung, Seung-Hwa;Kim, Su-Kyeong;Lee, Ji-Hyun;Choi, Soo-Ih;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.2
    • /
    • pp.74-81
    • /
    • 2020
  • Objective: To prevent low back pain, an objective evaluation tool to evaluate pelvic mobility and exercise to improve the flexibility of the lumbar region is needed. The purpose of this study was to compare the results of pelvic mobility measurements using the Wii Balance Board (WBB) and Sensbalance Therapy Cushion (STC), evaluate the usefulness of the STC as a tool for measuring pelvic mobility. Design: Cross-sectional study. Methods: Fifty healthy subjects participated in this study. The subjects performed pelvic mobility range, proprioception, reaction time and reach of the arm using the STC. The pelvic movement parameter was measured two times to determine the intra-rater reliability. To measure the correlation between lumbar muscle tension and pelvic mobility, Myovision was used to measure tension of L4, L5 level erector spinae muscle. Correlations between measured variables were checked to determine the validity of the pelvic mobility assessment tool. Results: STC showed high test-retest reliability in pelvic tilt measurement and reaching task [intraclass correlation coefficients (3,1)=0.804-0.915]. The relationship between WBB and STC showed a significant positive correlation with the pelvic tilt and reaching task (p<0.05). Posterior tilt and erector spinae activation (Lt. L5) showed a significant negative correlation (p<0.05). Left, right tilt and erector spinae activation (L5) showed a significant negative correlation (p<0.05). Conclusions: This study confirmed the advantages of the STC and found efficiency as an objective measuring device of pelvic mobility.

A Survey on the Current Status of Human Research Protection Program Settlement and Subject Protection Activities in Korea (국내 임상시험 및 대상자 보호프로그램 도입 현황과 안전관 리체계에 대한 설문조사 연구)

  • Park, Sinyoung;Cho, Su Jin;Seo, Kyung Jeong;Kim, Jin Seok
    • The Journal of KAIRB
    • /
    • v.3 no.2
    • /
    • pp.28-36
    • /
    • 2021
  • Purpose: The purpose of this study is to assess the status of the Human research Protection Program (HRPP) within a hospital or a research institute in Korea. Methods: Survey was conducted during June 12th-21th 2019. Survey was distributed to the members of Korean Association of IRB (KAIRB) through each IRB office. Descriptive statistics were performed using SPSS ver. 26. Results: A total of 86 people responded, and 75 (87.0%) answered that they have perceived the HRPP. Seventy out of 86 respondents (81.4%) were conducting internal audit, several institutions were operated simultaneously the other form of audits such as IRB audit, system audit. Regarding the management of Suspected Unexpected Serious Adverse Reaction (SUSAR), 62.8% answered that they have regulation that can decide to suspend the study when there is a risk to subject safety. Among the respondents, 66.3% performed 'Help desk.' Conclusion: In this study, we assessed the current status of HRPP operation at each research institution based on Ministry of Food and Drug Safety (MFDS) HRPP guidelines. The HRPP accredited institution operated the subject protection activities according to this program, and even if the HRPP was not officially operated, the related activities were conducted focusing on the cases that could have a significant impact on the safety of research subjects. In order to ensure the quality of domestic clinical trials and to stably establish the HRPP, efforts at the individual institution level will be required.

  • PDF