• Title/Summary/Keyword: Reaction Accuracy

Search Result 396, Processing Time 0.021 seconds

TWO-Point Reactor Kinetics for Large D$_2$O Reflected Systems (다량의 중수반사체 계통에 대한 2-점노 운동방정식)

  • Noh, T.W.;Oh, S.K.;Kim, S.Y.;Kim, D.H.
    • Nuclear Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.192-197
    • /
    • 1987
  • Two-point kinetic equations for a compact-core-with-bulky-D$_2$O-reflector system were developed. A unique feature of the system is that certain fission gammas create retarded photoneutrons in the D$_2$O reflector by (r, n) reaction. Coupling effect between the core and the reflector was investigated by simulating power transients with various ramp reactivity insertions. Special attention was paid to the phenomenon associated with spatial separation of photoneutrons and their precursors. Simulations show that accuracy of the two-point model is comparable with that of space-dependent approach. Also it is found that the explicily expressed photoneutron terms in the reflector equation slow down the power transient compared to non-photoneutron expressions. Detectors for reactor power control purpose prefer to be deployed in the core zone to be able to accurately perdict transient power.

  • PDF

Evaluation of Proposed Diagnostic System for Detection of Pan-enterovirus Using Reverse Transcription Nested PCR from Water Environment

  • Siwon Lee;Kyung Seon Bae;Jin-Ho Kim;Ji-Hyun Park;Ji Hye Kim;Ji-Yeon Park;Kyung-Jin Lee;Chae-Rin Jeon;Jeong-Ki Yoon;Soo-Hyung Lee;Eung-Roh Park
    • Biomedical Science Letters
    • /
    • v.29 no.2
    • /
    • pp.81-87
    • /
    • 2023
  • Pan-Enterovirus (Pan-EV) infects millions of children and infants worldwide every year. As severe infections have recently been reported, the need for monitoring has consequently intensified. Pan-EV is a categorical name for waterborne enteroviruses belonging to the Picornaviridae family, and includes a wide range of pathogens including Coxsackievirus (CoxV), Echovirus (EcoV) and Enterovirus (EV). In this study, we proposed an optimal RT-nested PCR method for diagnosis of various types of Pan-EV in an aquatic environment and developed a positive control. Considering detection sensitivity, specific reaction, and final identification, one condition capable of amplifying 478 bp among the four candidates in the 1st round PCR (RT-PCR) and one condition in the 2nd round PCR (nested PCR) were selected. Through the detection of nucleic acids extracted from 123 groundwater samples and the detection sensitivity test based on artificial spiking in the sample, the methods are optimal for non-disinfected water samples such as groundwater. We developed a positive control for Pan-EV detection that can be amplified to different sizes under the two conditions. Accuracy could be further improved by testing for contamination from the control group. The method proposed in this study and the positive control developed are expected to be used in monitoring Pan-EV in aquatic environments including groundwater through future research using more samples.

Rapid Detection of Streptococcus mutans Using an Integrated Microfluidic System with Loop-Mediated Isothermal Amplification

  • Jingfu Wang;Jingyi Wang;Xin Chang;Jin Shang;Yuehui Wang;Qin Ma;Liangliang Shen
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.8
    • /
    • pp.1101-1110
    • /
    • 2023
  • Streptococcus mutans is the primary causative agent of caries, which is one of the most common human diseases. Thus, rapid and early detection of cariogenic bacteria is critical for its prevention. This study investigated the combination of loop-mediated isothermal amplification (LAMP) and microfluid technology to quantitatively detect S. mutans. A low-cost, rapid microfluidic chip using LAMP technology was developed to amplify and detect bacteria at 2.2-2.2 × 106 colony-forming units (CFU)/ml and its detection limits were compared to those of standard polymerase chain reaction. A visualization system was established to quantitatively determine the experimental results, and a functional relationship between the bacterial concentration and quantitative results was established. The detection limit of S. mutans using this microfluidic chip was 2.2 CFU/ml, which was lower than that of the standard approach. After quantification, the experimental results showed a good linear relationship with the concentration of S. mutans, thereby confirming the effectiveness and accuracy of the custom-made integrated LAMP microfluidic system for the detection of S. mutans. The microfluidic system described herein may represent a promising simple detection method for the specific and rapid testing of individuals at risk of caries.

Application of Response Surface Methodology for Optimization of Nature Dye Extraction Process (천연색소 추출공정 최적화를 위한 반응표면분석법의 적용)

  • Lee, Seung Bum;Lee, Won Jae;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.29 no.3
    • /
    • pp.283-288
    • /
    • 2018
  • As the use of environmentally friendly and non-disease natural pigments grows, various methods for extracting natural pigments have been studied. The natural color was extracted from parsley, a vegetable ingredient containing natural dyes. Target color codes of green series of natural dyes extracted as variables #50932C (L = 55.0, a = -40.0, b = 46.0) were set with the pH and temperature of extracted natural color coordinates (of the extracted), and the quantitative intensities of natural dyes were analyzed. During the colorimetric analysis predicted by the reaction surface analysis method, a color coordinate analysis was conducted under the optimal conditions of pH 8.0 and extraction temperature of $60.9^{\circ}C$. Under these conditions, predicted figures of L, a, and b were 55.0, -36.3, and 36.8, respectively, while actual experimental ones confirmed were 69.0, -35.9, and 31.4, respectively. In these results, the theory accuracy and actual error rate were confirmed to be 73.0 and 13.8%, respectively. The theoretical optimization condition of the color difference (${\Delta}E$) was at the pH of 9.2 and extraction temperature of $55.2^{\circ}C$. Under these conditions the predicted ${\Delta}E$ figure was 12.4 while the experimental one was 13.0. The difference in color analysis showed 97.5% of the theoretical accuracy and 4.5% of the actual error rate. However, the combination of color coordinates did not represent a desired target color, but rather close to the targeted color by means of an arithmetic mean. Therefore, it can be said that when the reaction surface analysis method was applied to the natural dye extraction process, the use of color coordinates as a response value can be a better method for optimizing the dye extraction process.

Determination of finasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 finasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.345-351
    • /
    • 2011
  • A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) method was developed and validated for the determination of finasteride in human serum. Beclomethasone was used as internal standard (IS) and liquid-liquid extraction (LLE) using methyl tert-butyl ether (MTBE) was carried out to isolate analyte. The mass transitions monitored in multiple reaction monitoring (MRM) in positive ion mode were m/z 373.2${\rightarrow}$305.2 for finasteride and m/z 409.3${\rightarrow}$391.2 for IS. Retention times of finasteride and IS were 5.81 and 5.46 min, respectively. The limit of quantitation (LOQ) was 0.1 ng/mL and the calibration curve showed good linearity in the range of 0.1~20.0 ng/mL ($R^2$=0.9997). The intra-day assay precision and accuracy were in the range 6.3~10.6% and 97.3~103.6%, respectively, and the inter-day assay precision and accuracy were in the range 0.8~5.2% and 99.8~102.5%, respectively. The sample extract recovery of the method was 80~83%.

Analysis of dutasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 dutasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Jung, Ki-Kyung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.76-82
    • /
    • 2012
  • The determination and confirmation of dutasteride in human serum was performed by a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Beclomethasone as an internal standard (I.S.) was added to the serum and the mixed sample was pretreated by liquid-liquid extraction (LLE) with methyl tert-butyl ether (MTBE). The mass transitions of dutasteride and I.S. monitored in multiple reaction monitoring (MRM) were m/z 529.6${\rightarrow}$461.5 and m/z 409.3${\rightarrow}$391.2, respectively, and the retention times were 6.45 and 5.46 min, respectively. The calibration curve was linear in the concentration range of 0.5~30.0 ng/mL ($R^2$= 0.9999) and the limit of quantitation (LOQ) was found to be 0.5 ng/mL. The recovery of dutasteride was shown to be 66~72%. The intra-day assay precision and accuracy were in the range 3.5~5.5% and 85.7~89.9%, respectively, and the interday assay precision and accuracy were in the range 4.2~5.8% and 90.8~95.8%, respectively.

Effective Method for Extraction of Cell-Free DNA from Maternal Plasma for Non-Invasive First-Trimester Fetal Gender Determination: A Preliminary Study

  • Lim, Ji-Hyae;Park, So-Yeon;Kim, Shin-Young;Kim, Do-Jin;Kim, Mee-Jin;Yang, Jae-Hyug;Kim, Moon-Young;Kim, Min-Hyoung;Han, Ho-Won;Choi, Kyu-Hong;Ryu, Hyun-Mee
    • Journal of Genetic Medicine
    • /
    • v.7 no.1
    • /
    • pp.53-58
    • /
    • 2010
  • Purpose: To find the most effective method for extraction of cell-free DNA (cf-DNA) from maternal plasma, we compared a blood DNA extraction system (blood kit) and a viral DNA extraction system (viral kit) for non-invasive first-trimester fetal gender determination. Materials and Methods: A prospective cohort study was conducted with maternal plasma collected from 44 women in the first-trimester of pregnancy. The cf-DNA was extracted from maternal plasma using a blood kit and a viral kit. Quantitative fluorescent-polymerase chain reaction (QF-PCR) was used to detect the SRY gene and AMEL gene. The diagnostic accuracy of the QF-PCR results was determined based on comparison with the final delivery records. Results: A total of 44 women were tested, but the final delivery record was only obtained in 36 cases which included 16 male-bearing and 20 female-bearing pregnancies. For the blood kit and viral kit, the diagnostic accuracies for fetal gender determination were 63.9% (23/36) and 97.2% (35/36), respectively. Conclusion: In non-invasive first-trimester fetal gender determination by QF-PCR, using a viral kit for extraction of cf-DNA may result in a higher diagnostic accuracy.

Test-Retest Reliability of Attention Network Test Scores in Schizophrenia (조현병 환자가 시행한 주의력 네트워크 검사 점수의 검사-재검사 신뢰도)

  • Lee, Jae-Chang;Kim, Ji-Eun;Kim, Min-Young;Yang, Jisun;Han, Myung-Hun;Kwon, Hyukchan;Kim, Kiwoong;Lim, Sanghyun;Jung, Eun-eui;Kim, Ji-Woong;Im, Woo-Young;Lee, Sang-Min;Kim, Seung Jun
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.25 no.2
    • /
    • pp.210-217
    • /
    • 2017
  • Objectives : Although the Attention Network Test(ANT) has been widely used to assess selective attention including alerting, orienting, and conflict processing, data on its test-retest reliability are lacking for clinical population. The objective of the current study was to investigate test-retest reliability of the ANT in healthy controls and patients with schizophrenia. Methods : Fourteen patients with schizophrenia and 23 healthy controls participated in the study. They are tested with ANT twice with 1 week interval. Test-retest reliability was analyzed with Pearson and Intra-class correlations. Results : Patients with schizophrenia showed high test-retest correlations for mean reaction time, orienting effect, and conflict effect. Also, they showed moderate to high test-retest correlations for mean accuracy and moderate test-retest correlations for alerting effect and conflict error rate. On the other hand, healthy controls revealed high test-retest correlations for mean reaction time and moderate to high test-retest correlations for conflict error rate. In addition, they revealed moderate test-retest correlations for alert effect, orienting effect, and conflict effect. Conclusions : The mean reaction time, alerting effect, orienting effect, conflict effect, and conflict error rate of ANT showed acceptable test-retest reliabilities in healthy controls as well as patient with schizophrenia. Therefore, the analyses of these reliable measures of ANT are recommended for case-control studies in patients with schizophrenia.

System Development for Measuring Group Engagement in the Art Center (공연장에서 다중 몰입도 측정을 위한 시스템 개발)

  • Ryu, Joon Mo;Choi, Il Young;Choi, Lee Kwon;Kim, Jae Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.3
    • /
    • pp.45-58
    • /
    • 2014
  • The Korean Culture Contents spread out to Worldwide, because the Korean wave is sweeping in the world. The contents stand in the middle of the Korean wave that we are used it. Each country is ongoing to keep their Culture industry improve the national brand and High added value. Performing contents is important factor of arousal in the enterprise industry. To improve high arousal confidence of product and positive attitude by populace is one of important factor by advertiser. Culture contents is the same situation. If culture contents have trusted by everyone, they will give information their around to spread word-of-mouth. So, many researcher study to measure for person's arousal analysis by statistical survey, physiological response, body movement and facial expression. First, Statistical survey has a problem that it is not possible to measure each person's arousal real time and we cannot get good survey result after they watched contents. Second, physiological response should be checked with surround because experimenter sets sensors up their chair or space by each of them. Additionally it is difficult to handle provided amount of information with real time from their sensor. Third, body movement is easy to get their movement from camera but it difficult to set up experimental condition, to measure their body language and to get the meaning. Lastly, many researcher study facial expression. They measures facial expression, eye tracking and face posed. Most of previous studies about arousal and interest are mostly limited to reaction of just one person and they have problems with application multi audiences. They have a particular method, for example they need room light surround, but set limits only one person and special environment condition in the laboratory. Also, we need to measure arousal in the contents, but is difficult to define also it is not easy to collect reaction by audiences immediately. Many audience in the theater watch performance. We suggest the system to measure multi-audience's reaction with real-time during performance. We use difference image analysis method for multi-audience but it weaks a dark field. To overcome dark environment during recoding IR camera can get the photo from dark area. In addition we present Multi-Audience Engagement Index (MAEI) to calculate algorithm which sources from sound, audience' movement and eye tracking value. Algorithm calculates audience arousal from the mobile survey, sound value, audience' reaction and audience eye's tracking. It improves accuracy of Multi-Audience Engagement Index, we compare Multi-Audience Engagement Index with mobile survey. And then it send the result to reporting system and proposal an interested persons. Mobile surveys are easy, fast, and visitors' discomfort can be minimized. Also additional information can be provided mobile advantage. Mobile application to communicate with the database, real-time information on visitors' attitudes focused on the content stored. Database can provide different survey every time based on provided information. The example shown in the survey are as follows: Impressive scene, Satisfied, Touched, Interested, Didn't pay attention and so on. The suggested system is combine as 3 parts. The system consist of three parts, External Device, Server and Internal Device. External Device can record multi-Audience in the dark field with IR camera and sound signal. Also we use survey with mobile application and send the data to ERD Server DB. The Server part's contain contents' data, such as each scene's weights value, group audience weights index, camera control program, algorithm and calculate Multi-Audience Engagement Index. Internal Device presents Multi-Audience Engagement Index with Web UI, print and display field monitor. Our system is test-operated by the Mogencelab in the DMC display exhibition hall which is located in the Sangam Dong, Mapo Gu, Seoul. We have still gotten from visitor daily. If we find this system audience arousal factor with this will be very useful to create contents.

Effects and optimum conditions of pre-reductant in the analysis of inorganic arsenic by hydride generation-atomic absorption spectrometry (HG-AAS에 의한 무기비소 분석 시 예비환원제의 최적화 조건과 분석에 미치는 영향)

  • Song, Myung Jin;Park, Kyung Su;Kim, Young Man;Lee, Won
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.396-402
    • /
    • 2005
  • We try to look for optimum conditions of pre-reductants like L-Cysteine, KI and $FeSO_4$ when analyzing inorganic arsenic by using hydride generation-atomic absorption spectrometry, and run a comparative study of effect in the analysis of them. Also, we separated and analyzed only inorganic arsenic by using $H_2SO_4$-trap to eliminate organic arsenic which are MMA(monomethylarsonate) and DMA(dimethylarsinate). Under the conditions of mixture acid of 1.8 M HCl and 0.08 M $HNO_3$, arsenic standard solution of 20 ppb have more higher absorbance than without adding acid. In case of L-Cysteine, As(V) completely reduces into As(III) when 0.5 g of L-Cysteine is reacted more than 30 mins. in weak acid condition of approximately 0.07 M $HNO_3$ or HCl. In the event of KI, As(V) completely reduces into As(III) when 3 g of KI is reacted more than 1hour in acid condition of 0.8 M $HNO_3$. On the occasion of $FeSO_4$, the inside of tube is blocked by precipitation by mixture reaction of $NaBH_4$ and $Fe^{2+}$, therefore, comparing to other pre-reductants, reproducibility of efficiency of reducing As(V) to As(III) is low. To evaluate the accuracy of the analytical results, we use NIST SRM 1643C Trace Elements in Water ($82.1{\pm}1.2ng/mL$). The results are satisfactory.