• Title/Summary/Keyword: Rays

Search Result 2,337, Processing Time 0.027 seconds

Effects of Delayed Gamma-Irradiation and CA Storage on the Quality of Chestnuts (수확 후 지연 감마선 조사와 CA 저장이 밤의 품질에 미치는 영향)

  • 권중호;정형욱;김경은;정헌식;최종욱
    • Food Science and Preservation
    • /
    • v.8 no.1
    • /
    • pp.16-22
    • /
    • 2001
  • The study was performed to investigate the effects of delayed gamma-irradiation and CA storage on the keeping quality of chestnuts. Chestnuts peviously stored for 3 months at 0$^{\circ}C$ were irradiated at 0 to 0.25 kGy of Co$\^$60/ gamma rays and then stored for 6 months under CA conditions of 3% O$_2$ and 5% CO$_2$ or air at 0$^{\circ}C$. Delayed gamma-irradiation completely inhibited the sprouting of chestnuts, and tore reduced the rotting rate by the combination with CA storage. The weight loss was reduced by delayed gamma-irradiation and CA storage. Hunter L and b values of flesh surface of the chestnuts stored under CA were higher than those of samples stored under air regardless of gamma irradiation. Vitamin C, total sugar and reducing sugar contents decreased immediately after irradiation Vitamin C and reducing sugar contents after 6 months of storage were lower in the samples kept under CA than in those under air. Results indicated that delayed gamma-irradiation after harvest and subsequent CA storage showed inhibitory effects against the development of saluting and rotting and the loss of weights and surface flesh color changes in chestnuts.

  • PDF

Treatment and posttreatment changes following intrusion of maxillary posterior teeth with miniscrew implants for open bite correction (Miniscrew implant를 이용한 상악 구치부 압하와 개방교합 치료의 효과 및 안정성)

  • Lee, Han-Ah;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.31-40
    • /
    • 2008
  • Objective: This study investigated the skeletal and dentoalveolar changes after intrusion of maxillary posterior teeth using miniscrew implants during the treatment and posttreatment period. Method: The subjects consisted of 11 adults (1 male, 10 females) whose open bites were treated by posterior teeth intrusion with miniscrew. The lateral cephalometric x-rays of pre-treatment, post-treatment, and the retention period were evaluated. Results: The average intrusion of maxillary posterior teeth at the end of the treatment period was 2.22 mm (p < 0.001) and the average extrusion of maxillary posterior teeth at the end of the 17.4 month retention period was 0.23 mm (p = 0.359). The relapse rate was calculated at 10.36%. A decrease in overbite after the 17.4 month retention period was 0.99 mm (p < 0.05). The relapse rate was calculated at 18.10%. The skeletal changes and vertical height change of maxillary posterior teeth during the retention period was statistically insignificant, but there was a significant decrease in overbite (mean 0.99 mm, p < 0.05). The amount of intrusion and the overbite improvement from treatment significantly correlates to the degree of relapse. Conclusions: The results indicate that intrusion of the maxillary posterior teeth using miniscrews is an effective, non-surgical treatment modality which can reasonably be used to address adult open bite.

Evaluation of the mechanical properties and clinical efficacy of biphasic calcium phosphate-added collagen membrane in ridge preservation

  • Lee, Jung-Tae;Lee, Yoonsub;Lee, Dajung;Choi, Yusang;Park, Jinyoung;Kim, Sungtae
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.4
    • /
    • pp.238-250
    • /
    • 2020
  • Purpose: This study aimed to evaluate the biocompatibility and the mechanical properties of ultraviolet (UV) cross-linked and biphasic calcium phosphate (BCP)-added collagen membranes and to compare the clinical results of ridge preservation to those obtained using chemically cross-linked collagen membranes. Methods: The study comprised an in vitro test and a clinical trial for membrane evaluation. BCP-added collagen membranes with UV cross-linking were prepared. In the in vitro test, scanning electron microscopy, a collagenase assay, and a tensile strength test were performed. The clinical trial involved 14 patients undergoing a ridge preservation procedure. All participants were randomly divided into the test group, which received UV cross-linked membranes (n=7), and the control group, which received chemically cross-linked membranes (n=7). BCP bone substitutes were used for both the test group and the control group. Cone-beam computed tomography (CBCT) scans were performed and alginate impressions were taken 1 week and 3 months after surgery. The casts were scanned via an optical scanner to measure the volumetric changes. The results were analyzed using the nonparametric Mann-Whitney U test. Results: The fastest degradation rate was found in the collagen membranes without the addition of BCP. The highest enzyme resistance and the highest tensile strength were found when the collagen-to-BCP ratio was 1:1. There was no significant difference in dimensional changes in the 3-dimensional modeling or CBCT scans between the test and control groups in the clinical trial (P>0.05). Conclusions: The addition of BCP and UV cross-linking improved the biocompatibility and the mechanical strength of the membranes. Within the limits of the clinical trial, the sites grafted using BCP in combination with UV cross-linked and BCP-added collagen membranes (test group) did not show any statistically significant difference in terms of dimensional change compared with the control group.

Assessment of Effective Dose from Diagnostic X-ray Examinations of Adult (진단X선에 의한 성인의 진단행위별 유효선량평가)

  • Kim, Woo-Ran;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.155-164
    • /
    • 2002
  • Methodology to evaluate the effective doses to adults undergoing various diagnostic x-ray examinations were established by Monte Carlo simulation of the x-ray examinations. Anthropomorphic mathematical phantoms, the MIRD5 male phantom and the ORNL female phantom, were used as the target body and x-ray spectra were produced by the x-ray spectrum generation code SPEC78. The computational procedure was validated by comparing the resulting doses to the results of NRPB studies for the same diagnostic procedures. The effective doses as well as the organ doses due to chest, abdomen, head and spine examinations were calculated for x-rays incident from AP, PA, LLAT and RLAT directions. For instance, the effective doses from the most common procedures, chest PA and abdomen AP, were 0.029 mSv and 0.44 mSv, respectively. The fact that the effective dose from PA chest x-ray is far lower than the traditional value of 0.3 mSv(or 30 mrem), which results partly from the advances of technology in diagnostic radiology and partly from the differences in the dose concept employed, emphasizes necessities of intensive assessment of the patient doses in wide ranges of medical exposures. The methodology and tools established in this study can easily be applied to dose assessments for other radiology procedures; dose from CT examinations, dose to the fetus due to examinations of pregnant women, dose from pediatric radiology.

Medical Exposure of Korean by Diagnostic Radiology and Nuclear Medicine Examinations (진단방사선 및 핵의학 검사에 의한 한국인의 의료상 피폭)

  • Kwon, Jeong-Wan;Jeong, Je-Ho;Jang, Ki-Won;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.4
    • /
    • pp.185-196
    • /
    • 2005
  • Although medical exposure from diagnostic radiology procedures such as conventional x-rays, CT and PET scans is necessary for healthcare purposes, understanding its characteristics and size of the resulting radiation dose to patients is much of worth because medical radiation constitutes the largest artificial source of exposure and the medical exposure is in a trend of fast increasing particularly in the developed society. Annual collective doses and per-caput effective doses from different radiology procedures in Korea were estimated by combining the effective dose estimates per single medical procedure and the health insurance statistics in 2002. Values of the effective dose per single procedure were compiled from different sources including NRPB reports, ICRP 80, MIRDOSE3.1 code and independent computations of the authors. The annual collective dose reaches 27440 man-Sv (diagnostic radiology: 22880 man-Sv, nuclear medicine: 4560 man-Sv) which is reduced to the annual per-caput effective dose of 0.58 mSv by dividing by the national population of 47.7 millions. The collective dose is far larger than that of occupational exposures, in the country operated 16 nuclear power plants in 2002, which is no more than 70 man-Sv in the same year. It is particularly noted that the collective dose due to CT scans amounts 9960 man-Sv. These results implies that the national policy for radiation protection should pay much more attention to optimization of patient doses in medicine.

Spectroscopic Properties of a Silicon Photomultiplier-based Ce:GAGG Scintillation Detector and Its Applicability for γ-ray Spectroscopy (감마선 분광분석을 위한 실리콘 광 증배소자 기반 Ce:GAGG 섬광검출기의 분광특성 연구)

  • Park, Hye Min;Kim, Jeong Ho;Kim, Dong Seong;Joo, Koan Sik
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.73-78
    • /
    • 2015
  • In this study, a scintillation detector was fabricated using a silicon photomultiplier (SiPM) and a Ce:GAGG scintillator single crystal, and its spectroscopic properties were compared with those of commercially available LYSO and CsI:Tl scintillators using ${\gamma}$-ray spectroscopy. The energy resolutions of the self-produced scintillation detector composed of the scintillator single crystal (volume: $3{\times}3{\times}20mm^3$) and SiPM (Photosensitive area: $3{\times}3mm^2$) for standard ${\gamma}$-ray sources, such as $^{133}Ba$, $^{22}Na$, $^{137}Cs$ and $^{60}Co$ were measured and compared. As a result, the energy resolutions of the proposed Ce:GAGG scintillation detector for g-rays, as measured using its spectroscopic properties, were found to be 13.5% for $^{133}Ba$ 0.356 MeV, 6.9% for $^{22}Na$ 0.511 MeV, 5.8% for $^{137}Cs$ 0.662 MeV and 2.3% for $^{60}Co$ 1.33 MeV.

Gamma-ray-induced skin injury in the mini-pig: Effects of irradiation exposure on cyclooxygenase-2 expression in the skin (감마선조사에 의한 돼지 피부장애에 cyclooxygenase-2의 발현변화)

  • Kim, Joong Sun;Park, Sunhoo;Jang, Won Seok;Lee, Sun Joo;Lee, Seung Sook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.65-72
    • /
    • 2015
  • The basic concepts of radiation-induced skin damage have been established, the biological mechanism has not been studied. In this study, we have examined the effects of gamma rays on skin injury and cyclooxygenase(COX)-2 expression. Gamma irradiation induced clinicopathological changes in a dose- and time-dependent manner in mini-pig skin. The histological changes were consistent with the changes in gross appearance at 12 weeks after irradiation. After three days' irradiation, apoptotic cells in the basal layer were found more frequently in irradiated skin than in normal skin, with the magnitude of the effect being dose-dependent. The thickness of the epidermis transiently increased 3 days after irradiation, and then gradually decreased, although changes in the epithelial thickness of the irradiated field were not observed with irradiation doses over 50 Gy. In the epithelium, there was an initial degenerative phase, during which the rate of basal cell depletion was dependent on the radiation dose (20-70 Gy). One week after irradiation, COX-2 expression was mostly limited to the basal cell layer and was scattered across these cells. High COX-2 expression was detected throughout the full depth of the skin after irradiation. The COX-2 protein is upregulated after irradiation in mini-pig skin. These histological changes associated with radiation exposure dose cause the increased COX-2 expression in a dose-dependent fashion.

Early Life History of the Red Marbled Rockfish, Sebastiscus tertius (Barsukov et Chen) 1. Egg Morphology and Development of Larvae and Juveniles (붉은쏨뱅이, Sebastiscus tertius (Barsukov et Chen)의 초기생활사 1. 난의 형태 및 산출 자치어의 성장에 따른 형태발달)

  • 김광수;임상구;한경호;오성현;노병율
    • Journal of Aquaculture
    • /
    • v.12 no.1
    • /
    • pp.15-24
    • /
    • 1999
  • From January 1997 to May, the red marbled rockfish, Sebastiscus tertius (Barsukov et Chen) was reared in the laboratory, and observed the morphological characteristies of egg and development of larvae and juveniles. The egg is spherical in shape colorless and transparent, measuring 0.72~0.80mm in diameter (mean 0.75mm, n=50). The naturally bearing larvae were 3.79~3.97mm in total length with 7~8+15~16=22~24 myomeres, and mouth and anus were open. Melanophores were present on the yolk of the larva and ventral margins of the tail. The 1~2 days after bearing larvae measured 3.90~4.13mm in total length, and transformed to postlarval stage, and yolk sac were completely resorbed. On the lower jaw melanophores were present. Total length of the larvae was 4.23~4.60mm in total length (11 days after bearing), number of elongated pectoral fin rays was 9~10, and melanophores distributed on the top of head, around the intestine tube, ventral margins of the tail and on the pectoral fin. In 21 days after bearing, the larva were 5.83~7.10mm in total length, and the caudal notochord flex $45^{\circ}$. Individuals of 9.80~12.36mm in total length (33 days after bearing) are regarded to have reached to the juvenile stage with all the fins were developed.

  • PDF

Usefulness of Vibration Response Imaging (VRI) for Pneumonia Patients (폐렴환자에서 진동 공명 영상 검사(VRI)의 유용성)

  • Park, Eu-Gene;Park, Jung-Hee;Hong, Mi-Jin;Kim, Won-Dong;Lee, Kye-Young;Kim, Sun-Jong;Kim, Hee-Joung;Ha, Kyoung-Won;Chon, Gyu-Rak;Kim, Hyun-Ai;Yoo, Kwang-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.1
    • /
    • pp.30-36
    • /
    • 2011
  • Background: Pneumonia is commonly seen in outpatient clinics. it is widely known as the most common cause of death from infectious disease. Pneumonia has been diagnosed by its typical symptoms, chest X-ray and blood tests. However, both chest X-rays and blood tests have limitations in diagnosis. Thus primary care clinicians usually have been constrained due to a lack of adequate diagnostic tools. Vibration response imaging (VRI) is a newly emerging diagnostic modality, and its procedure is non-invasive, radiation-free, and easy to handle. This study was designed to evaluate the diagnostic usefulness of the VRI test among pneumonia patients and to consider its correlation with other conventional tests such as Chest X-ray, laboratory tests and clinical symptoms. Methods: VRI was performed in 46 patients diagnosed with pneumonia in Konkuk University Medical Center. VRI was assessed in a private and quiet room twice: before and after the treatment. Sensors for VRI were placed on a patient's back at regular intervals; they detected pulmonary vibration energy produced when respiration occurred and presented as specific images. Any modifications either in chest X-ray, C-reactive protein (CRP), white blood cell count (WBC) or body temperature were compared with changes in VRI image during a given time course. Results: VRI, chest X-ray and CRP scores were significantly improved after treatment. Correlation between VRI and other tests was not clearly indicated among all patients. But relatively severe pneumonia patients showed correlations between VRI and chest X-ray, as well as between VRI and CRP. Conclusion: This study demonstrates that VRI can be safely applied to patients with pneumonia.

A Study On Characteristics Of Forged Sealing Made Of Photosensitive Resin (감광성 수지로 제작된 위조 인영의 특성에 관한 연구)

  • Han, Sang-Deog;Jeong, Yang-Kwon;Choi, Jae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1385-1391
    • /
    • 2012
  • The authenticity of a document is recognized only when sealing on the document can be recognized to be the same as the original seal of a person who drew up the document. But forge in various ways is prevalent; forge through stamp-copy, forge through photocopying, forge through computer seal sculpture machine, forge through photosensitive resin, etc. Among the methods above, a method of making a forged seal with photosensitive resin panels, which is one of the easiest forging methods, enables making a forged seal the same as the original seal through the work of projecting ultraviolet rays on a resin panel on which negative film is stuck after making it using the original seal. But as research into this reality has not been sufficiently carried on, it is difficult to identify forged sealing through photosensitive resin seals, indeed. For this reason, unless regulations about making forged seals using resin machine for print are enforced, crimes related to forged seals using photosensitive resin are expected to increase in the future. Thus, after stamping 10 resin seals made based on an original seal carved of thick and thin strokes of characters, this paper intends to clarify that there are differences between original sealing and forged sealing through sealing identification method. Consequently, we verified the significant difference in the statistics between original sealing and forged sealing.