• Title/Summary/Keyword: Rays

Search Result 2,337, Processing Time 0.028 seconds

The Study on Correlation between the Forward Head Posture and Spinal Alignment (전방머리자세(Forward Head Posture)의 정도와 척추 만곡 변형의 상관관계)

  • Jung, Hyun-Woo;Shin, Woo-Suk;Kim, Doo-Hee;Park, Won-Hyung;Cha, Yun-Yeop;Ko, Youn-Seok;Lee, Jung-Han;Chung, Won-Suk;Shin, Byung-Cheul;Song, Yun-Kyung;Go, Ho-Yeon;Sun, Seong-Ho;Jeon, Chan-Yong;Jang, Bo-Hyoung;Ko, Seong-Gyu
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.4
    • /
    • pp.195-202
    • /
    • 2013
  • Objectives This study was designed to investigate the correlation between the forward head posture and the spinal alignment. Methods We examined the whole spine x-rays of the 144 student sample. We measured the Craniovertebral angle (CVA), Cervical angle (CA), Thoracic kyphotic angle (TKA), lumbar lordosis angle (LLA) and Ferguson's angle (FA) of the students. We then analyzed the relationship between these angles. Results CVA had correlation with CA, but it was weak. There was significant correlation between CVA and TKA. There were no significant correlation among CVA, LLA and FA. Conclusions According to above results, there is a negative relationship between the CVA and the TKA - in that higher CVAs yielded lower TKAs. But CVA had no significant correlation with LLA or FA.

Diffuse Pulmonary Nodular Lesions Persisting for 5 Years (5년간 지속된 미만성 폐결절)

  • Kim, Kyung-Kyu;Kim, Byung-Kyu;Jeong, Ki-Hwan;Jeong, Hye-Cheol;Kim, Je-Hyeong;Park, Sang-Myen;Lee, Sin-Hyung;Shin, Chol;Cho, Jae-Youn;Shim, Jae-Jeong;In, Kwang-Ho;Kang, Kyung-Ho;Yoo, Se-Hwa;Oh, Yu-Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.802-807
    • /
    • 2000
  • Diffuse pulmonary nodular lesions have many causes. When they are caused by infection, the likely organisms are M. tuberculosis and various fungi. Silicosis, eosinophilic granuloma and pulmonary metastasis should be considered for differential diagnosis. Differential diagnosis needs detailed clinical history, physical examination and various laboratory tests. A case of persistent diffuse pulmonary nodular lesions which had persisted 5 years is reported. The patient was a 25 years old man with minimal pulmonary symptoms. Detailed past history and physical examination suggested thyroid tumor. Chest radiography showed numerous evenly sized well-defined nodules scattered in entire lung fields. Previous chest X-rays showed similar nodular lesions, which had lasted for 5 years. The number of nodules was slightly increased. Neck CT showed heterogenous mass in left lobe of thyroid gland and multiple lymphadenopathies along both internal jugular chains. Total thyroidectomy was performed. A case of lung metastasis which progressed slowly in papillary thyroid cancer is reported.

  • PDF

Changes of Optically Stimulated Luminescence Dosimeter Sensitivity with High Dose (고선량에 대한 광자극발광선량계의 방사선 민감도 변화 연구)

  • Han, Su Chul;Kim, Kum Bae;Choi, Sang Hyoun;Park, Seungwoo;Jung, Haijo;Ji, Young Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.98-104
    • /
    • 2016
  • We investigated the effect of high dose on the sensitivity of optically stimulated luminance dosimeters (OSLDs) on Co-60 gamma rays and used a commercial OLSD (Landauer, Inc., Glenwood, IL). New OSLDs were chosen arbitrarily and were irradiated with 1 Gy repeatedly. We confirmed the change in the radiation sensitivity after repeated irradiation. The OSLD sensitivity increased up to 3% after irradiating for seven times and decreased continuously after the eighth time. It dropped by approximately 0.35 Gy per irradiation. Finally, after irradiating for 30 times, the OSLD sensitivity decreased by approximately 7%. When the OSLDs were irradiated 10 times with 1 Gy after their irradiation using a high dose of 15 Gy and 30 Gy, their sensitivity decreased by 6% and 12%, respectively, compared to that before high-dose irradiation. The change in the OSLD sensitivity with a high dose could be modeled by an exponential equation. We confirmed the radiation sensitivity variation caused by a high dose, and the irradiation history of dosimeters was considered to reuse OSLDs irradiated with a high dose.

Early Growth Changes in Juvenile Abalone Haliotis discus discus Produced by Irradiation with Low-dose 60Co Gamma Rays (저선량 60Co감마선 조사 후 생산된 둥근전복(Haliotis discus discus)치패의 초기성장 변화에 관한 연구)

  • Jwa, Min Seok;Yeo, In-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.2
    • /
    • pp.193-199
    • /
    • 2015
  • We observed that the growth and physiological change in Haliotis discus discus by low-dose irradiation with gamma ray.Irradiation with gamma ray was undertaken by using the low-level irradiation facility ($^{60}CO$) in cooperation with the Institute of Nuclear Science and Technology at Jeju National University. The parent abalones were attached one by one and then fixed by using the rubber band to the front side of the fabricated case for irradiation with gamma ray. The experimental plots of irradiation with gamma ray were set as 10, 15, 20 and 25 Gy and the 25 female abalones and 10 male abalones were utilized for each experimental plot. The sperms and eggs were fertilized by setting an interval for each dose to prevent mixing with other experimental plots when fertilizing the sperms and eggs for each dose of irradiation with gamma ray. As for the fertility, it was confirmed to be 85% the control and 10 Gy groups, whereas it was found to be 80%, 65% and 50% in the 15 Gy, 20 Gy and 25 Gy groups, respectively. As a conclusion, the hatching rate and attachment rate were higher at 10 and 15 Gy than the other experimental plots, and the growth rate was higher at 20 Gy than the other experimental plots. Also the changes in lysozyme activity in accordance with the stress of water temperature were found to have a significant increase in the other experimental plots as compared with the control plot at the end of 0 h. The changes in lysozyme activity have remained constant in all the experimental plots at the end of 12 h. These results allowed us to confirm that lysozyme was undertaking the biodefense action by reacting sensitively to the stress of water temperature in the control experimental plot. As for the other experimental plots, they are believed to avoid the biodefense mechanism due to the high degree of anti-parasite mechanism and anti-viral mechanism. Thus, it is believed that it would be imperative to conduct development and research on breeds that were potent for environmental tolerance by applying the method of irradiation with gamma ray to other marine animals and plants.

Dose Distribution of Wedge filter by Dose Rate in LINAC (선형가속기의 선량율에 따른 쐐기필터의 선량분포)

  • Gwon, Taehyeong;Kim, Seunguk;Yoon, Yonghak;Won, Doyeon;Jeong, Kyeonghwan;Jung, Jaeeun;Cho, Juneho
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.323-329
    • /
    • 2015
  • This study is aimed at assessing whether dynamic wedge filters are appropriate to be used instead of physical wedge filters. The X-ray energy generated from linear accelerator is commercialize 6 MV and 10 MV. $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ of physical wedge filter was irradiated by dose rate 100, 200, 300, 400, 500, and 600 MU/min for each angle and for comparison with a dynamic wedge filter, irradiate 96 times under the same conditions. The measurement conditions are as 100 cm source-film distance and $10{\times}10cm$ irradiated surface. A developed film was scanned and analyzed after a calibration through a dose analysis program and the dose rate was compared after calculating the standard deviation. Dynamic wedge filters make dose, scattered rays and treatment time reduced and very useful due to less irradiated doses to patients. The errors at each dose rate under the same conditions were irrelevant. Thus, treatment based on a high dose rate depending on the patient is expected to be feasible.

Thermoluminescene Properties of Li6Gd(BO3)3:Ce3+ Scintillation Single Crystal (리튬 가돌리늄 보레이트 섬광단결정의 열형광 특성)

  • Kim, Sunghwan;Lee, Joonil
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.455-459
    • /
    • 2014
  • We grew the $Li_6Gd(BO_3)_3:Ce^{3+}$ scintillator and determined the scintillation and thermoluminescence properties for X-rays. The emission spectrum of $Li_6Gd(BO_3)_3:Ce^{3+}$ is located in the range of 370~500 nm, peaking at 423 nm an 455 nm, due to the $4f{\rightarrow}5d$ transition of $Ce^{3+}$ ions. The fluorescence decay time of the crystal is composed three components. The fast component is 60 ns (25%), the intermediate component is 787 ns (29%) and the slow component is $5.9{\mu}s$ (46%) of the crystal. The after-glow is caused by the electron and hole traps in the crystal lattice. We determined physical parameters of the traps in the crystal. The thermoluminescence trap are composed two traps. The determined activation energy (E), kinetic order (m) and frequency factor (s) of the first trap are 0.65 eV, 1.01 and $6.9{\times}10^8s^{-1}$. And, the determined activation energy, kinetic order and frequency factor of the second trap are 0.96 eV, 1.79 and $3.1{\times}10^{12 }s^{-1}$, respectively.

The Fabrication and Evaluation of HgI2 Semiconductor Detector as High Energy X-ray Dosimeter Application (고에너지 X선 선량계 적용을 위한 TiO2 첨가된 요오드화수은 반도체 검출기 제작 및 평가)

  • Choi, Il Hong;Noh, Sung Jin;Park, Jung Eun;Park, Ji Koon;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.383-387
    • /
    • 2014
  • In this paper, for a new detection system development with the better accurate dose evaluation and beam distribution imaging using the small field irradiation of linear accelerator, the compound semiconductor based detection sensors were fabricated and the performance evaluation was investigated. The special particle-in-binder sedimentation was used for a large area film sensor fabrication. The detection properties for high energy x-rays were investigated from a dark current, an output current, a rising time, a falling time, and response delay measurement. The experimental results, the $TiO_2$ mixed $HgI_2$ sensor showed the best electrical characteristics than $PbI_2$, PbO, pure $HgI_2$. Linearity, repeatability, and accuracy tests from LINAC were tested, the $TiO_2$ mixed $HgI_2$ sensor showed the better performance than the commercially available dosimetry devices.

Design and Fabrication of an Energy Saving LED-Fishing Lamp (에너지 절감형 LED 집어등의 설계 및 제작)

  • Choi, Sung-Kuk;Kim, Sun-Jae;Park, Dae-Won;Kil, Gyung-Suk;Choi, Chul-Young;Song, Sang-Bin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.515-521
    • /
    • 2010
  • This paper dealt with the design and fabrication of an energy saving light emitting diode (LED) fishing lamp. Most fishes such as a squid, horse mackerel, mackerel, sardine and scabbard fish have characteristics for phototaxis and fishing lamps have promoted the fishery efficiency using their photo-reaction. In these days, metal halide lamp (MHL) as the fishing lamp, which consumes 1.5 kW and radiates harmful ultraviolet rays are mainly used. To develop the LED-fishing lamp, the penetration depth in sea water and the photo-reaction of a squid as light wavelength were studied. The experimental results showed the both characteristics were existed in blue color around 470 nm. Based on the results, we manufactured a 160 W and blue LED-fishing lamp which is consume about one-nine of 1.5 kW MHL. As energy saving effect, the use of LED-fishing lamp can reduce 128 kWh per an hour which is correspond to $CO_2$ of 86 kg for a 22ton-fishing boat equipped with 80-1.5 kW MHL. Now, the prototype LED fishing lampsare being evaluated on two fishing boats.

Soft Plasma Flash X-ray Generator Utilizing a Vacuum Discharge Capillary

  • Sato, Eiichi;Hayasi, Yasuomi;Usuki, Tatsumi;Sato, Koetsu;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.400-403
    • /
    • 2002
  • The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments were primarily performed in order to generate line spectra such as x-ray lasers. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbo-molecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -10.8 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 ${\mu}$m aluminum filter were less than 30 ${\mu}$s, and we detected the aluminum characteristic x-ray intensity using a 6.8 ${\mu}$m aluminum filter. In the spectrum measurement, two sets of aluminum and titanium electrodes were employed, and we observed multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. In the case where the titanium electrode was employed, the line number decreased with corresponding decreases in the capillary length. Compared with incoherent visible light, these rays from the capillary were diffracted and diffused greatly after passing through two slits.

  • PDF

Quasi-monochromatic Parallel Radiography Achieved with a Polycapillary Plate

  • Sato, Eiichi;Komatsu, Makoto;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Ichimaru, Toshio;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.418-421
    • /
    • 2002
  • Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.

  • PDF