엑티브 셀 밸런싱을 위한 새로운 전력 피드백 방식의 플라이백 토폴로지에 관한 연구 (Study on the Fly-back Topology of New Power Feed-back Method for Active Cell Balancing )

  • 강성용;송명진;박성미;박성준;고재하
    • 한국산업융합학회 논문집
    • /
    • 제26권6_2호
    • /
    • pp.1083-1095
    • /
    • 2023
  • Recently, the demand for low-voltage, high-capacity ESS is rapidly increasing due to the revitalization of the e-mobility industry, which is mainly powered by electricity. In addition, the demand for portable power banks is rapidly increasing due to the revitalization of leisure industries such as camping and fishing. The ESS with this structure consists of a small number of series cells and many parallel cells, resulting in a system with a large rated current. Therefore, the number of power devices for cell balancing configured in series is small, but a balancing device with a large current capacity is required. Construction of a constant temperature device in such a low-voltage, high-current ESS is difficult due to economic issues. The demand for an active balancing system that can solve the passive balancing heating problem is rapidly increasing. In this paper, propose a power feedback fly-back topology that can solve the balancing heating problem. The characteristic of the proposed topology is that a series-connected voltage sharing voltage is used as the input of the flyback converter, and the converter output is connected to one transformer. In this structure, the converter output for cell voltage balancing shares magnetic flux through one high-frequency transformer, so the cell voltage connected to the converter automatically converges to the same voltage.

비상 발전기를 이용한 유도전동기의 소프트 기동 시스템 (Soft Start System of Induction Motor using Emergency Generator)

  • 황보찬;고재하;이정환;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.433-441
    • /
    • 2022
  • In general, in an emergency generator system for an electric facility including an induction motor load, an emergency power generation facility larger than the facility load capacity is built due to the initial starting current of the induction motor. In order to reduce this economic burden, various methods to reduce the inrush current of induction motors are applied to suppress the additional expansion of generators due to the reduction of power generation facilities and the increase in electrical facilities. Among these methods, when a system with a built-in soft start function of an induction motor using an inverter is built, it is the best way to reduce the inrush current of the induction motor to less than the rated current. However, in this case, the installation cost of the inverter to drive the induction motor increases. This paper proposes a soft start method of an induction motor by expanding the frequency and voltage control operation area of an emergency generator. In addition, proposed a speed calculation method based on power factor information, which is essential information for stable soft start of an induction motor, and a method for generating a speed command value of the governor for starting with maximum torque.

기동시뮬레이션 방법에 의한 유도전동기 기동방식 선정 (Selection of Motor Starting Method by Numeric Simulation)

  • 장중구;서상진;이민용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.817-820
    • /
    • 2002
  • Since a squirrel cage induction motor by NEMA Design types is designed to withstand full-voltage starting, direct starting method can be the most economical one. Starting a squirrel cage motor from standstill by connecting it directly across the line may allow inush currents of approximately 500-600% of rated current at lagging power factor of 35-50%. For many of the large motors, the starting inrush current may be great enough to cause voltage dips, which may adversely affect the building's lighting system. Electric utilities also have restrictions on starting currents, so that voltage fluctuations can be held to prescribed limits. Therefore the need for choosing the most appropriate method of motor starting is quite essential. In this paper, we proposed a plan for the selection of the most appropriate motor starting method, first by way of numeric simulation using manufacturer's data and second by way of actual experience. So far, more often than not, the selection of motor starting method has been accomplished only as regards to the capacity of the motor and the frequency of starting and stopping. But nowadays such high-tech apparatus as soft starters are being developed, and we are on the position to give more attention to clarify the way of selection of the motor starting method.

  • PDF

인위적인 전자파에 의한 TTL IC의 오동작 및 파괴 특성 (Breakdown and Destruction Characteristics of the TTL IC by the Artificial Microwave)

  • 홍주일;황선묵;허창수
    • 한국안전학회지
    • /
    • 제22권5호
    • /
    • pp.27-32
    • /
    • 2007
  • We investigated the damage of the TTL ICs which manufactured five different technologies by artificial microwave. The artificial microwave was rated at a microwave output from 0 to 1000W, at a frequency of 2.45GHz. The microwave power was extracted into a standard rectangular waveguide(WR-340) and TTL ICs were located into the waveguide. TTL ICs were damaged two types. One is breakdown which means no physical damage is done to the system and after a reset the system is going back into function. The other is destruction which means a physical damage of the system so that the system will not recover without a hardware repair. TTL SN74S08N and SN74ALS08N devices get a breakdown and destruction occurred but TTL SN74LS08N, SN74AS08N and 74F08N devices get a destruction occurred. Also destructed TTL ICs were removed their surface and a chip conditions were analyzed by SEM. The SEM analysis of the damaged devices showed onchipwire and bondwire destruction like melting due to thermal effect. The tested results expect to be applied to the fundamental data which interprets the combination mechanism of the semiconductors from artificial microwave environment.

인버터 구동 유도전동기에서 과도전압의 측정과 분석 (Measurement and Analysis of Transient Voltage for an Inverter-fed Induction Motor)

  • 길경석;류길수;박대원;조영진;천상규;최수연
    • 한국철도학회논문집
    • /
    • 제10권6호
    • /
    • pp.650-654
    • /
    • 2007
  • 유도전동기는 전기차량의 주요 동력원으로 광범위하게 사용되고 있으며, 유도전동기의 속도제어에 펄스변조 방식을 이용한 인버터의 사용이 증가하고 있다. 본 논문에서는 유도전동기의 인버터 구동시 발생하는 과도전압에 대해 연구하였다. 전원 케이블의 길이에 따른 과도전압의 크기를 측정하였으며, 시간변화율과 운전주파수에 의한 영향을 분석하였다. 실험결과, 케이블의 길이가 길어짐에 따라 과도전압의 최대값이 증가하였으며 50m 케이블에서 과도전압의 크기는 최대 3.3PU까지 측정되었다. 이러한 현상은 진행파의 반사와 투과에 의해 발생하며, 유도전동기의 인버터 구동시 케이블의 길이에 따른 과도전압의 영향을 고려하여 유도전동기의 절연을 설계해야 할 것이다.

BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가 (An Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion)

  • 박성철;하주완;김환용;송영학
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.669-679
    • /
    • 2018
  • Energy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics.

온실가스감축효과를 고려한 태양광 연계형 에너지저장장치(ESS) 보급전략에 대한 연구 (A Research on PV-connected ESS dissemination strategy considering the effects of GHG reduction)

  • 이원구;김강원;김발호
    • 에너지공학
    • /
    • 제25권2호
    • /
    • pp.94-100
    • /
    • 2016
  • 에너지저장장치(ESS)는 전력수급 불균형 해소, 신재생에너지의 출력안정, 주파수 조정용 등 전력공급 안정성 향상 및 효율적 전기에너지사용 등에 기여하는 중요자원으로, 전세계적으로 '23년까지 '14년 설치용량의 약 30배가 증가한 55.9GWh의 보급이 전망되고 있다. 이와 같이 급증하는 세계시장에서 국내 ESS 업계의 경쟁력 확보를 위해서는 자국내 설치실적(Track Record) 확보가 필요한데, 우리나라는 주파수 조정용(FR용(用))과 그간 지속되어 왔던 전력수급 불균형 상황에 대비하기 위한 부하이동용 중심으로 ESS를 보급하여 왔다. 하지만, 주파수 조정용의 경우 통상적으로 화력발전소 정격용량의 약 5% 범위에서 설치효용이 발생하는 것으로 평가되고 있어, 화력발전이 비약적으로 증가하지 않는 한 국내 시장의 확장성이 부족하다고 할 수 있으며, 여유로운 예비력 확보정책에 따라 부하이동용에 대해서도 보급필요성이 저하되고 있는 바, 새로운 방식의 보급확대 대상이 필요하다고 할 수 있다. 유망한 신규보급대상은 간헐적 출력의 약점은 있으나, 신기후체제 대응과 산업육성을 위해 지속적으로 추진예정인 신재생에너지와의 연계설치를 통해 신재생에너지의 출력을 안정화 하고, 신재생에너지 발전량의 계통투입시기 조절을 통한 이산화탄소 저감효과를 기대할 수 있는 분야라고 할 수 있다. 본 연구에서는 향후 에너지정책의 최대 화두인 신기후체제 대응을 위한 온실가스 감축수단을 활용할 수 있도록, 태양광 연계형 ESS 충방전모드를 온실가스 저감효과를 고려토록 설계한 후, 투자유도를 위한 REC 가중치 산정방법에 대한 정책대안을 제시하였다.

타워와 블레이드의 탄성효과를 고려한 부유식 해상풍력발전기의 동적거동해석 (Dynamic Behavior Analysis of Floating Offshore Wind Turbine Including Flexible Effects of Tower and Blade)

  • 정혜영;손정현
    • 대한기계학회논문집A
    • /
    • 제36권8호
    • /
    • pp.905-911
    • /
    • 2012
  • 부유식 해상풍력발전기의 시뮬레이션을 위해서 본 연구에서는 2MW 육상 풍력발전기에 부유구조물인 Tension Leg Platform(TLP) 구조를 추가하였다. 기상청 관측데이터와 해수면으로부터의 높이에 대해 풍속을 정의하는 지수법칙을 이용하여 풍하중을 산출하고 블레이드와 타워에 일정한 높이간격으로 적용하였다. 상대모리슨 방정식을 이용하여 파랑하중을 모델링하였다. 블레이드의 회전속도를 정격속도인 18rpm 으로 고려하고, 풍하중과 파랑하중 작용 시 2MW의 부유식 해상풍력기의 동적거동 해석을 수행하였다. 파랑하중에 대한 해상풍력기의 공진특성을 조사하기 위해 타워와 블레이드의 탄성체 모델을 구성하여 해상풍력기의 고유진동수를 계산하였다. 타워와 블레이드의 탄성효과가 해상풍력기의 거동에 미치는 영향을 분석하기 위해 타워만 탄성체로 구성된 탄성타워모델과 타워와 블레이드가 탄성체로 고려된 탄성타워 블레이드모델을 각각 강체 모델과 비교하였다.

1MWh급 레독스흐름전지의 부하이전용 최적운전에 따른 전기요금 절감효과 분석 (Analysis of Electricity Cost Saving Effect by the Optimal load shifting Operation with 1MWh Redox Flow Battery)

  • 백자현;고은영;강태혁;이한상;조수환
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1151-1160
    • /
    • 2016
  • In recent years, the energy storage systems such as LiB, NaS, RFB(Redox-Flow Battery), Super- capacitor, pumped hydro storage, flywheel, CAES(Compressed Air Energy Storage) and so on have received great attention as practical solutions for the power supply problems. They can be used for various purpose of peak shaving, load leveling and frequency regulation, according to the characteristics of each ESS(energy storage system). This paper will focus at 1 MWh RFB system, which is being developed through the original technology project of energy material. The output of ESS is mainly characterized by C-rate, which means that the total rated capacity of battery will be delivered in 1 hour. And it is a very important factor in the ESS operation scheduling. There can be several options according to the operation intervals 15, 30 and 60minutes. The operation scheduling is based on the optimization to minimize the daily electricity cost. This paper analyzes the cost-saving effects by the each operating time-interval in case that the RFB ESS is optimally scheduled for peak shaving and load leveling.

노후화된 누전차단기의 과전류 동작 특성에 관한 연구 (A Study on the Operating Characteristics of the Aged ELCB according to the Overcurrent)

  • 박예진;강신동;김재호
    • 한국안전학회지
    • /
    • 제38권5호
    • /
    • pp.1-7
    • /
    • 2023
  • This study analyzes the operational characteristics of 311 aged and non-aged residual current circuit breakers (RCCBs) in low-voltage consumer contexts. It investigates the influence of external temperature and harmonics based on the rated current multiples. To simulate temperature variations, a convectional oven was used around the circuit breakers. Additionally, the generation of harmonic reference signals and data measurement for overcurrent experiments were conducted using NI SCXI, myDAQ, and LabVIEW. An observation revealed that as the ambient temperature increased, the operating time of RCCBs decreased in the time delay region. This was attributed to the faster response or bending of the bimetal, which is the tripping element. However, aged RCCBs encountered challenges with tripping outside the protective curve. The operating time of the circuit breakers exhibited an acceleration influenced by the order and content of harmonic currents, potentially leading to malfunctions. Aged RCCBs demonstrated faster operating times than their non-aged counterparts. However, the difference in operating time varied based on the manufacturer's and operating environment of the RCCBs. Frequent malfunctions of RCCBs can result in power outages. In cases where these circuit breakers fail to operate, they can lead to secondary damages, including electrical fires and shocks. Consequently, it is imperative to consider the operating environment of RCCBs and provide appropriate replacement cycles to mitigate these risks.