• Title/Summary/Keyword: Rate Test

Search Result 13,439, Processing Time 0.047 seconds

Burning Rate Characteristics of Solid Propellant at Extremely High Pressure (초고압에서 고체 추진제의 연소속도 특성)

  • Sung, Hong-Gye;Yoo, Ji-Chang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-66
    • /
    • 2006
  • Notable are the burning rate characteristics of solid propellant burning at extremely high pressure(10000-20000 psia). The burning rate test using closed bomb shows the discontinuous increment around 4000 psia so that the exponent of burning rate(n) is almost double, from 0.4 to 0.8. The pressure-increasing rate of the test motor is about 300 times as high as that of the motor operating at the conventional pressure, less than 2000 psia, is, therefor the burning rate is augmented about 5-50 times. The performance prediction reflecting the pressure-change-rate effect are fairly comparable with the test data at various test conditions.

Calculation of Uncertainty in Measuring Heat Release Rate in Room Corner Test (룸코너 시험기의 발열량 측정에 대한 불확도 산정)

  • Noh, Kwang-Chul;Kim, Chi-Hoon;Lee, Seung-Chul;Lee, Duck-Hee
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.16-22
    • /
    • 2012
  • In fire test, accurate heat release rate measurements provide important information to define the fire safety characteristics of products. The calculation of heat release rate depends on the errors of measuring parameters in experimental set-up. In this study, the uncertainty factors of heat release rate in the room corner test facility, which is installed at Korea Railroad Research Institute, were analyzed. Through the fire testings for the KTX interior materials, the uncertainties of heat release rate were calculated. Results showed that uncertainty was high in the initial stage of fire test and gradually decreased with the growth of fire. The oxygen concentration was a major factor contributing to the combined relative standard uncertainty.

A study on performance of outdoor air flow rate through viovent for hybrid ventilation equipment (자연급기구내 플리머필터 설치 시 외기 침기량 분석에 관한 연구)

  • Yi, Seong-Hwan;Choi, Jong-Ak
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1337-1342
    • /
    • 2009
  • This test was progressed in the test house of KICT as sectional research of Center for Sustainable Housing. It included a ventilation rate of hybrid ventilation equipment, temperature, and gas test using the SF-6. The purpose of this test is to demonstrate the performance of viovent by estimating an outdoor air flow rate through viovent which the flimmer filter is installed and decide the leakage after operating the constant airflow fan within a house. First, the outdoor airflow rate through viovent measured $130\;m^3/h$ more than a legal required ventilation rate, $104\;m^3/h$. And then it sufficiently satisfy a legal standard, 0.7 air change/h. Secondly, the result of this test exposes that the leakage in the residence is about $20{\sim}25%$. Especially, the outdoor air flowing through the gate occupies 50% of the total leakage.

  • PDF

A Study on Injection Rate Characteristics of a Diesel Injector (디젤 인젝터의 분사율 특성에 관한 연구)

  • Chung, Jaewoo;Kim, Namho;Lim, Chanhyun;Kim, Dugjin
    • Journal of ILASS-Korea
    • /
    • v.20 no.4
    • /
    • pp.217-222
    • /
    • 2015
  • In this study, Injection rate tests of a Diesel common-rail injector have been performed with injection volume measurement type injection rate test system EMI21 for construction of injector model can be used in an engine calibration mean valued model. The measuring principle of the test system is based on measurement of dispalcement of a movable measurement piston by the volume of fluid released by the injector. From these injection rate test results, the characteristics on shape of instantaneous injection rate and injection fuel amount have been investigated and injection fuel amount calculation equation based on test results has been newly constructed. This equation is very simple and calculation error is less than 5% with test results for wide range injection pressure (200~1800 bar) and injection duration ($200{\sim}1800{\mu}s$) conditions. So, it is anticipated that newly constructed simple injection fuel amount model in this study can be efficiently used on engine calibration and control model.

Leak Test for Propulsion System of Launch Vehicle (발사체 추진 시스템의 기밀시험)

  • Lim, Ha-Young;Han, Sang-Yeop;Yi, Moo-Keun
    • Aerospace Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.103-108
    • /
    • 2012
  • There is close correlation between the reliability of the launch vehicle and the leakage of the propellants or gases from the launch vehicle. This paper describes the definition of the leak rate to determine the quantity of the leakage and introduce the unit conversion of the leak rate. The main parameters for the leak rate were considered. The requirements for the gaseous for the leak test of launch vehicle and various leak test methods were introduced. Leak test method and procedure used in space launch vehicle were briefly described.

A Nonparametric Test for Clinical Trial with Low Infection Rate

  • Mark C. K. Yang;Donguk Kim
    • Communications for Statistical Applications and Methods
    • /
    • v.5 no.3
    • /
    • pp.707-722
    • /
    • 1998
  • This paper evaluates a new clinical trial designs for low infection rate disease. This type of sparse disease reaction makes the traditional two sample t-test or Wilcoxon rank-sum test inefficient compared to a new test suggested. The new test, which is based solely on the larger changes, is shown to be more effective than existing method by simulation for small samples. However, this test can be shown to be connected to the locally most powerful rank test under certain practical conditions. This design is motivated in testing the treatment effects in periodontal disease research.

  • PDF

A Study of Correlation between Electromyography(EMG) and the Heart Rate Variability(HRV) Test, and Their Role as Predicting Factors for Peripheral Facial Palsy Prognosis (말초성 안면신경마비 환자에서 EMG(Electromyography)와 HRV(Heart Rate Variability)의 임상적 예후인자로서의 유용성 및 상관성 연구)

  • Kim, Chan-Young;Kim, Jong-In;Lee, Sang-Hoon;Park, Dong-Suk;Koh, Hyung-Kyun
    • Journal of Acupuncture Research
    • /
    • v.25 no.2
    • /
    • pp.189-197
    • /
    • 2008
  • Objectives : This study was performed in order to investigate the effectiveness of electromyography and the Heart Rate Variability(HRV) test as prognosis factors, and to clarify correlation between Electromyography and the Heart Rate Variability test. Methods : 44 Bell's palsy patients who were graded V on the House-Brackmann scale and underwent HRV and EMG testing were retrospectively reviewed based on medical records. Results from both tests were analyzed via simple linear regression, and bivariate correlation analysis was performed to investigate the correlation between results from the two tests. The severity of the facial palsy at onset and at 2 weeks after treatment were evaluated with the H-B grade and Yanagihara grading system, and was converted into improvement scores. Results : Mean axonal loss according to electromyography showed a statistically significant correlation in predicting peripheral facial palsy improvement(p<0.01). HR, SDNN, TP, LF, HF, VLF, and LF/HF ratio on the Heart Rate Variability test showed no significant correlation in predicting peripheral facial palsy improvement. Mean axonal loss determined by electromyography, and HR, SDNN, TP, LF, HF, VLF, and LF/HF ratio recorded with the Heart Rate Variability test was analyzed with the bivariate correlation analysis method. Mean axonal loss and SDNN showed a statistically significant correlation(p<0.01) Conclusions : The Heart Rate Variability test has no statistical significance in predicting peripheral facial palsy improvement. SDNN has a statistically significant correlation with mean axonal loss as determined by electromyography.

  • PDF

Calculation of Sample Size for Guided Missile Considering Test Method and Reliability Growth (유도무기 시험평가 방법과 신뢰성 성장을 고려한 시험 수량 산출)

  • Lee, Youn-ho;Kim, Jae-hwang;Lee, Kye-shin;Lee, Jong-sin;Lee, Myoung-jin;Kim, Doo-hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.844-852
    • /
    • 2017
  • Since guided weapon is high-cost and one-shot device which is non-reusable, it requires a lot of resources to prove required accuracy as a part of reliability demonstration. Once a test for proving accuracy rate of guided missile fails, it causes an additional cost and delay of schedule. This study introduces an equation for proper sample size and plan for guided-missile accuracy rate test in order to minimize the risk of test failure. Proper sample size for the test is derived by considering the reliability growth. Furthermore, each task for accuracy rate test is defined according to the development step. Therefore, this study can contribute to reduce sample size for accuracy rate test in order to meet the reliability requirement and assure transparency in the test process.

Evaluation of Material Properties Variations of Cementitious Composites under High Strain Rate by SHPB Test and Image Analysis (SHPB 시험 및 영상분석을 통한 고변형율 속도 하의 시멘트 복합체 물성 변화 평가)

  • Cho, Hyun-Woo;Lee, Jang-Hwa;Min, Ji-Young;Park, Jung-Jun;Moon, Jae-Heum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.83-91
    • /
    • 2015
  • Under impact or blast loads, concrete behaves with different mechanical properties comparing to the static loading conditions. In other words, with high strain rate, mechanical properties of concrete vary significantly. To evaluate the compressive characteristics of concrete with high strain rate, SHPB(Split Hopkinson Pressure Bar) test is typically used. However, because SHPB test method has been developed for metallic materials, it is necessary to verify the applicability of SHPB for brittle materials such as concrete. Also, there have been little researches on the evaluations of mechanical characteristics of UHPC under high strain rate conditions. This study has been performed to evaluate and analyse the compressive characteristics of plain concrete and UHPC with SHPB test apparatus. Also, to verify the applicability of SHPB test for concrete, direct displacement image analysis with high speed camera was performed for the comparisons with analytical solutions for SHPB test.

Detection of Alternaria spp. in Carrot Seeds and Effect of the Fungi on Seed Germination and Seedling Growth of Carrot

  • Kim, Wan-Gyu;MatHur, Suaresh-Behari
    • The Plant Pathology Journal
    • /
    • v.22 no.1
    • /
    • pp.11-15
    • /
    • 2006
  • Five seed samples of carrot were tested to detect Alternaria spp. by blotter method. A. alternata and A. radicina were detected from all the seed samples as high as $25.8-70.5\%$ and $37.5-63.5\%$, respectively. A. dauci was detected from four seed samples as low as $0.5-7.5\%$. The three Alternaria spp. were detected from the pericarp and the seed coat and endosperm of the carrot seeds but not from the embryo by component plating test. A. alternata and A. radicina were much more detected from the pericarp than the seed coat and endosperm. A. dauci was detected from the pericarp and the seed coat and endosperm at similar rate. The seed sample which was most severely infected with A. radicina showed the lowest rate of germination in the test on top of paper (TP). In the TP test, differences in total infection rate of A. radicina and A. dauci of the seed samples were very closely correlated with those in incidence of seedling rot on the seed samples. However, there was no correlation between infection rate of A. alternata and rate of germination or seedling rot of the seed samples. Soil test for seedling growth revealed that there was no correlation between differences in total infection rate of A. radicina and A. dauci and those in rate of normal seedlings of the seed samples.