• Title/Summary/Keyword: Rapid detection kit

Search Result 95, Processing Time 0.034 seconds

Rapid Detection of Infectious Bursal Disease Virus (IBDV) in Chickens by an Immunochromatographic Assay Kit

  • Choi, Kang-Seuk;Oh, Jin-Sik;Jeon, Woo-Jin;Na, Keon-Sok;Lee, Eun-Kyoung;Lee, Youn-Jeong;Sung, Hwan-Woo;Ha, Gun-Woo;Kwon, Jun-Hun
    • Korean Journal of Poultry Science
    • /
    • v.37 no.2
    • /
    • pp.167-172
    • /
    • 2010
  • An immunochromatograhy (IC) based infectious bursal disease virus (IBDV) detection kit, which employed two anti-IBDV VP2 monoclonal antibodies, was evaluated for rapid diagnosis of infectious bursal disease virus (IBD). The detection limit of the IC kit for IBDV was $10^{3.1}$ to $10^{3.9}$ $EID_{50}$/mL, indicating that the IC kit detected IBDV sensitively as same as double antigen capture ELISA but less than a RT-PCR assay. The IC kit did not detect other viral pathogens such as Newcastle disease virus, infectious bronchitis, avian influenza virus, and infectious larynotracheitis virus. When applied to tissue samples of experimental chickens died 3 or 4 days post infection after very virulent IBDV (strain Kr/D62) infection, the IC kit detected IBDV in all samples of the bursa of Fabricius, spleen, kidney, cecal tonsil and in 87.5%, 37.5% and 0% of liver, thymus and proventriculus samples. In particular, BF tissue samples showed stronger signal bands than other tissues. Positive signal was observed. All except for one thymus sample of samples having negative results by the IC kit showed the same result with DAS-ELISA but RT-PCR assay detected IBDV in some of IC kit negative samples of thymus and proventriculus. When swab samples from the bursa of Fabricius of dead chickens (n=231) on field farms were tested, the sensitivity and specificity of the IC assay relative to RT-PCR was 100% (109/109) and 97.5% (119/122), respectively and kappa value between both assay was 0.97. The kit can provide a useful aid for rapid detection of IBDV in chickens under field circumstances.

Comparison of Analytical Methods for the Detection of Paralytic Shellfish Toxins (PSTs) (마비성패류독소 검출을 위한 분석법 비교)

  • Lee, Ka Jeong;Kwon, Soon Jae;Jung, Yeoun Joong;Son, Kwang Tae;Ha, Kwang Soo;Mok, Jong Soo;Kim, Ji Hoe
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.6
    • /
    • pp.669-674
    • /
    • 2017
  • Paralytic shellfish toxins (PSTs) are produced by marine dinoflagellate phytoplankton Alexandrium spp. and Gymnodinium spp. These toxins accumulate in filter feeding organisms such as bivalves and the ingestion of contaminated shellfish can cause illness in humans. The mouse bioassay (MBA) has been the preferred PST testing method worldwide for more than 50 years. However, this assay has several disadvantages, such as detection limits, non-toxic-profiles, and the ethical issues of using animals. The aim of this study was to establish an alternative to the MBA method for testing for PSTs. We optimized the analysis conditions of a post-column oxidation-high performance liquid chromatography (PCOX-HPLC) method and the Scotia Rapid Test Kit, and then compared the accuracy of these methods to the MBA method. The results demonstrated a strong correlation between the PCOX-HPLC method and the MBA, although the PCOX-HPLC method required expensive equipment and standard material, and was time consuming. The Scotia Rapid Test Kit promises to be a useful tool, as it provided rapid and qualitative results, although the method sometimes gave a false positive result that could not be explained by toxin profiles.

Evaluation of the Clinical Usefulness of the Xeniss Rapid TB kit for the Diagnosis of Tuberculosis (결핵진단에서 Xeniss Rapid TB kit의 임상적 유용성)

  • Park, Seung-Kyu;Lee, Woo-Chul;Hwang, Soo-Hee;Kwon, Eun-Si;Lee, Hung-Soon;Lee, Duk-Hyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.389-400
    • /
    • 2002
  • Background : The rapid diagnostic tests for tuberculosis are needed to facilitate early treatment of tuberculosis and prevention of Mycobacterium tuberculosis transmission. The Xeniss Rapid TB kit is a rapid, card-based immunochromatographic test for the detection of antibodies directed against M. tuberculosis antigens including antigen 5(38-kDa antigen). The objective of this study was to evaluate the performance of the Xeniss Rapid TB kit for the diagnosis of active tuberculosis with serums from patients, asymptomatic healthy and close contact controls. Methods : 188 patients with active tuberculosis were tested; 177 with pulmonary tuberculosis(18 with combined pleurisy), and 11 with extrapulmonary tuberculosis. The control groups were composed of 82 close contacts and 57 healthy adults. Study subject were drawn from one national tuberculosis hospital for patients and close contacts, and another private hospital for healthy adults in Masan city, Korea. The Xeniss Rapid TB kit(Xeniss Life Science Co., Ltd., Seoul, Korea) was evaluated by using serum samples according to the instructions of the manufacturer by an investigator masked to the clinical and microbiological status of the study subjects. Results : The diagnostic sensitivity of the Xeniss Rapid TB kit was 73.9% in patients and specificities were 73.2% and 93.0% in close contact and healthy adults respectively. The positive predictive value in patients was 84.2% and the negative predictive value in controls was 85.8%. Conclusion : This study shows that the Xeniss Rapid TB test is a simple and fast method to diagnose active TB. The results of the sensitivity and specificites suggest that serodiagnosis using this point of care testing(POCT) device would be valuable and advantageous for screening tuberculosis in the clinical field.

Development of a Disperse Dye Immunoassay Technique for Detection of Antibodies against Neospora caninum in Cattle

  • Selahi, Fatemeh;Namavari, Mehdi;Hosseini, Mohammad Hossein;Mansourian, Maryam;Tahamtan, Yahya
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.1
    • /
    • pp.129-132
    • /
    • 2013
  • In this study a disperse dye immunoassay method was standardized and evaluated for detection of antibodies against Neospora caninum in cattle. Sera from 150 cattle with a recent history of abortion were collected and tested by commercial ELISA kit and a standardized in-house dye immunoassay system. The positivity rate for the sera used in this study was 34.6% for the disperse dye immunoassay (DDIA) compared to 32% obtained by ELISA kit. This study showed no significant difference between DDIA and ELISA. The results indicated that the DDIA provide an economic, simple, rapid and robust test for detection of N. caninum infection in cattle.

Development and Clinical Evaluation of a Rapid Serodiagnostic Test for Toxoplasmosis of Cats Using Recombinant SAG1 Antigen

  • Chong, Chom-Kyu;Jeong, Woo-Seog;Kim, Hak-Yong;An, Dong-Jun;Jeoung, Hye-Young;Ryu, Jeong-Eun;Ko, A-Ra;Kim, Yong-Joo;Hong, Sung-Jong;Yang, Zhaoshou;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.49 no.3
    • /
    • pp.207-212
    • /
    • 2011
  • Rapid serodiagnostic methods for Toxoplasma gondii infection in cats are urgently needed for effective control of transmission routes toward human infections. In this work, 4 recombinant T. gondii antigens (SAG1, SAG2, GRA3, and GRA6) were produced and tested for the development of rapid diagnostic test (RDT). The proteins were expressed in Escherichia coli, affinity-purified, and applied onto the nitrocellulose membrane of the test strip. The recombinant SAG1 (rSAG1) showed the strongest antigenic activity and highest specificity among them. We also performed clinical evaluation of the rSAG1-loaded RDT in 182 cat sera (55 household and 127 stray cats). The kit showed 0.88 of kappa value comparing with a commercialized ELISA kit, which indicated a significant correlation between rSAG1-loaded RDT and the ELISA kit. The overall sensitivity and specificity of the RDT were 100% (23/23) and 99.4% (158/159), respectively. The rSAG1-loaded RDT is rapid, easy to use, and highly accurate. Thus, it would be a suitable diagnostic tool for rapid detection of antibodies in T. gondii-infected cats under field conditions.

Characterization of beer-spoilage microorganism and its rapid detection by specific PCR primer (맥주오염미생물의 동정과 specific PCR primer의한 신속한 검출 방법)

  • Lee, Taek-In;Choi, Shin-Geon
    • Journal of Industrial Technology
    • /
    • v.28 no.A
    • /
    • pp.141-147
    • /
    • 2008
  • Several contaminated bacteria such as Lactobacillus brevis and Pediococcus damnosus in beer production cause beer spoilage by producing off flavours and turbidity. Detection of these organisms is complicated by the strict anaerobic conditions and lengthy incubation times required for their cultivation, consequently there is a need for more rapid detection methods. Recently, two contaminated strains were isolated from vessel of beer production and identified as Lactobacillus species by API kit identificaton as well as 16S-23S ITS sequencing analyses. Two isolated strains were named as Lactobacillus sp. HLA1 and Lactobacillus HLB2, respectively. A polymerase chain reaction (PCR) method was developed for the rapid and specific detection of Lactobacillus sp.. Two sets of primer pairs (HLA1-F/HLA1-R and HLB2-F/HLB2-R) were designed for the amplification of a 1576 base pair (bp) fragment of the HLA1 16S-23S rRNA gene and 1888 bp fragement of the HLB2 16S-23S rRNA. Amplified PCR products were highly specific to detect corresponding bacteria when other contaminated strains were used as PCR templates. However, detection of both strains were limited when $100{\mu}{\ell}$ of cultured samples were mixed with $100m{\ell}$ of beer sample in arbitrary manner. The sensitivity of the assay still needs to be improved for direct detection of the small amounts of bacteria present in beer.

  • PDF

Comparative Analysis of the Multiple Test Methods for the Detection of Pandemic Influenza A/H1N1 2009 Virus

  • Choi, Young-Jin;Nam, Hae-Seon;Park, Joon-Soo;Kim, Hwi-Jun;Park, Kyung-Bae;Jeon, Min-Hyok;Kim, Chang-Jin;HwangBo, Young;Park, Kwi-Sung;Baek, Kyoung-Ah
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.10
    • /
    • pp.1450-1456
    • /
    • 2010
  • Accurate and rapid diagnosis of Pandemic Influenza A/H1N1 2009 virus (H1N1 2009) infection is important for the prevention and control of influenza epidemics and the timely initiation of antiviral treatment. This study was conducted to evaluate the performance of several diagnostic tools for the detection of H1N1 2009. Flocked nasopharyngeal swabs were collected from 254 outpatients of suspected H1N1 2009 during October 2009. This study analyzed the performances of the RealTime Ready Inf A/H1N1 Detection Set (Roche), Influenza A (H1N1) Real-Time Detection Kit (Bionote), Seeplex Influenza A/B OneStep Typing Set [Seeplex Reverse Transcriptase PCR (RT-PCR)], BinaxNow Influenza A & B Test Kit [Binax Rapid Antigen Test (RAT)], and SD BIOLINE Influenza Ag kit (SD RAT). Roche and Bionote real-time RT-PCR showed identical results for the H1N1 2009 hemagglutinin gene. Compared with real-time RT-PCR, the sensitivities and specificities were 83.7% and 100% for Seeplex RT-PCR, 64.5% and 94.7% for Binax RAT, and 69.5% and 100% for SD RAT. The sensitivities of Seeplex RT-PCR, Binax RAT, and SD RAT in patients aged over 21 years were 73.7%, 47.4%, and 57.9%, respectively. The sensitivities of Seeplex RT-PCR, Binax RAT, and SD RAT on the day of initial symptoms were mostly lower (68.8%, 56.3%, and 31.3%, respectively). In conclusion, multiplex RT-PCR and RAT for the detection of H1N1 2009 were significantly less sensitive than real-time RT-PCR. Moreover, a negative RAT may require more sensitive confirmatory assays, because it cannot be ruled out from influenza infection.

Development of the rapid detection kit for Salmonella spp. using immunochromatographic assay (면역크로마토그라피 기법을 이용한 Salmonella 속균 신속 검출킷트 개발)

  • Jung, Byeong-yeal;Jung, Suk-chan
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.2
    • /
    • pp.191-197
    • /
    • 2005
  • An immunochromatographic (IC) strip for the rapid detection of Salmonella spp. in the enriched sample was developed. Affinity purified Salmonella polyclonal antibody was conjugated with 40 nm colloidal gold particles which were prepared by citrate method in our laboratory. The antigen-antibody-gold complex was captured by Salmonella antibody attached to test line of nitrocellulose membrane during the capillary migration of sample. Specificity of the IC strip was calculated to be 100% (12/12) and sensitivity was 97.6% (41/42) in the test with pure cultured bacteria. Salmonella was artificially inoculated into raw pork macerated with enrichment broth. And then it was 10-fold diluted from $5.2{\times}10^{8}CFU/ml$ to 5.2 CFU/ml. The IC strip could detect $5.2{\times}10^{6}CFU/ml$ before enrichment. However, the lowest limit of detection was 5.2 CFU/ml after overnight incubation. The results indicated that the IC assay was a rapid, economical and simple method with high specificity and sensitivity for the detection of Salmonella spp. without using any equipment.

Use of rapid diagnostic kit for the diagnosis of Korean native calf diarrhea (신속 진단 킷트를 활용한 한우 송아지의 설사증 원인체 검사)

  • Choe, Changyong;Jung, Young-Hun;Do, Yoon-Jung;Cho, Ara;Kim, Seong-Bum;Kang, Hee-Sung;Yoo, Jae-Gyu;Park, Jinho
    • Korean Journal of Veterinary Service
    • /
    • v.40 no.1
    • /
    • pp.61-66
    • /
    • 2017
  • Calf diarrhea is a disease experienced by almost all of calves after birth and is one of the representative causes of damage to farmers due to mass mortality and of economic losses to them by inhibiting normal growth. In this study, we conducted quick detection of etiologic agents of diarrhea by using a rapid diagnostic kit to multiply diagnose antigens of five etiologic agents of calf diarrhea (rotavirus, coronavirus, Escherichia coli, Cryptosporidium, Giardia) in Hanwoo (Korean native cattle) calves. When the positive antigen proportion of the calf diarrheal feces for each farm was analyzed, rotavirus, coronavirus, Escherichia coli, Cryptosporidium, and Giardia showed antigen positive rates of 0~67%, 0~20%, 0~60%, 0~20%, and 0~67%, respectively. With regard to the antigen positive rate by age in days after birth, 1-week-old calves showed the antigen positive rate of 20% in rotavirus and 20% in Giardia, and 2-week-old calves showed that of 50% in rotavirus. In addition, 4-week-old calves showed the antigen positive rate of 10% in rotavirus, 10% in coronavirus, 10% in Escherichia coli, and 30% in Giardia, and 8-week-old calves showed the antigen positive rate of 17% in coronavirus, 50% in Escherichia coli, 17% in Cryptosporidium, and 33% in Giardia. Based on the results of this study, the etiologic agents of diarrhea in Hanwoo calves for each farm are widely distributed. Although younger than 2-week-old calves were strongly positive for rotavirus, older than 4-week-old calves were highly positive for Giardia and Escherichia coli. In conclusion, we considered that a rapid diagnostic kit is an effective method for quick detection of etiologic agents and would be helpful for cattle farmers and veterinarians to select appropriate therapeutic method.

Comparison of a PCR Kit and a Selective Medium to Detect Pathogenic Bacteria in Eggs (PCR Kit와 선택배지를 이용한 계란의 병원성세균 검출 비교 평가)

  • Kim, Dong-Ho;Yun, Hye-Jeong;Song, Hyun-Pa;Lim, Sang-Yong;Jo, Min-Ho;Jo, Cheo-Run
    • Food Science and Preservation
    • /
    • v.16 no.6
    • /
    • pp.965-970
    • /
    • 2009
  • PCR technology has been widely used to detect and quantify microbial pathogens in foodstuffs, because the technique is rapid, sensitive, and selective. In this study, detection of contaminating pathogenic bacteria on shells of chicken eggs was performed using both a commercial multiplex polymerase chain reaction (PCR) kit and a viable count method employing a selective medium. The PCR kit was capable of detecting Campylobacter jejuni, Escherichia coli O157:H7, Staphylococcus aureus, Bacillus cereus, Vibrio parahaemolyticus, Listeria monocytogenes, Yersinia enterocolitica, Salmonella species, and Shigella species. Using the PCR method, five bacterial species were detected from 30 samples (33.3%) of 90 batches of eggs commercially available in a market. PCR products from B. cereus, S. aureus, L. monocytogenes, Y. enterocolitica, and E. coli O157:H7 were detected, and the numbers and frequencies of positive samples were 17 (18.8%), 12 (13.3%), 15 (16.6%), 16 (17.7%),and 4 (4.4%), respectively. None of any Salmonella species, C. jejuni, V. parahaemolyticus, or Shigella species was detected in this study. The results of PCR testing were confirmed using a typical viable count method employing a selective medium. We suggest that the multiplex polymerase chain reaction (mPCR) assay is a rapid and reliable method for detection of pathogenic bacteria contaminating eggs.