• Title/Summary/Keyword: Range of variation

Search Result 3,245, Processing Time 0.032 seconds

Performance Analysis of a Centrifugal Compressor for HFC-134a with Variation of Diffuser Vane Angle (디퓨저 베인 설치각 변화에 따른 R134a 원심압축기 성능 분석)

  • Park, Han-Young;Shin, You-Hwan;Lee, Yoon-Pyo;Kim, Kwang-Ho;Chung, Jin-Taek;Cho, Yong-Hun;Kim, Jong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2823-2828
    • /
    • 2007
  • Numerical simulation on the two-stage centrifugal compressor with Low Solidity Vaned Diffuser LSVD) for HFC-134a Turbo-chiller was performed using a commercial code. The comparative study with experimental results from other compressor was also investigated to testify the simulation schemes. The numerical analysis was separately simulated for each stage of the compressor and the effect of impeller-diffuser flow interaction was considered. Setting angle of the diffuser vane changed in the range of 15 deg. and the effects on its variation were discussed in detail including the flow analysis in the passage of the compressor. The vane setting angle obtained from the preliminary design was slightly adjusted to the optimal value by the performance enhancement in terms of pressure recovery and flow characteristics.

  • PDF

Variable Optical Attenuator using Optical Coupling between a Side Polished Fiber and Refractive Index Matching Liquid (측면 연마된 광섬유와 굴절률 정합액사이의 광결합을 이용한 가변 광 감쇠기)

  • Kim, Kwang-Taek;Song, Jae-Won
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.50-55
    • /
    • 1999
  • In this paper we proposed a variable optical attenuator using the side polished fiber coupled with a refractive index matching liquid. Small variation of refractive index of matching liquid can induce very large change of optical loss due to the coupling between the fiber mode and radiation mode. The thermo-optic effect of matching liquid was used to ontrol the optical attenuation. The side polished fiber block was fabricated using the silicon V gloove. Experimental results showed that $5^{\circ}C$ temperature variation was enough to adjust full range attenuation. The polarization dependent loss and insertion loss of the fabricated devices were 0.5dB and 0.2dB respectively.

  • PDF

Determination of Water Content in Ethanol by Miniaturized Near-Infrared (NIR) System

  • Cho, Soo-Hwa;Chung, Hoe-Il;Woo, Young-Ah;Kim, Hyo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.1
    • /
    • pp.115-118
    • /
    • 2005
  • The miniaturized NIR (Near-infrared) spectrometer has been utilized for the determination of water content (1-19% range) in ethanol that is the most popular organic solvent in pharmaceutical industries. It has many potential capabilities that can replace the conventional analyzers especially for the on-line measurement since it is compact, versatile and cost-effective. By using two dimensional (2D) correlation spectroscopy, it was preliminarily investigated to find any unforeseen spectral distortion among the spectra collected from the miniaturized spectrometer. The 2D study revealed that the spectral variation clearly followed the variation of water concentration without any spectral distortion or abnormality. PLS (Partial Least Squares) was employed to build the calibration model and the resulting prediction performance was acceptable and stable over several days. Even though the miniaturized NIR system was evaluated to fairly simple chemical matrix, the overall study demonstrates the sufficient feasibility for diverse practical and industrial applications.

Concentration Variations of Trace Elements in Gosan, Jeiu During the Polluted Period in November 2001 and the Yellow Sand Period in Spring 2002 (2001년 11월 오염시기와 2002년 봄 황사시기 제주도 고산에서의 미량원소 농도 변화)

  • Han J.S;Ghim Y.S;Moon K.J;Ahn J.Y;Kim J.E;Ryu S.Y;Kim Y.J;Kong B.J;Lee S.J
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.143-151
    • /
    • 2004
  • The chemical composition of PM$_{2.5}$ was measured at Gosan, Jeju for two weeks each in November 2001 and spring 2002. In the latter part of the measurement period of November 2001, designated as the polluted period in this work, secondarily formed ion components as well as primarily emitted elemental carbon were high. PM$_{2.5}$ mass concentration was also high in this polluted period compared with the yellow sand period, in which daily average of PM $_{10}$ peaked up to 520 $\mu\textrm{g}$/㎥. Increase of major components of anthropogenic origin in the polluted period was not correlated with the variation in sea salt components while increase of crustal components in the yellow sand period was highly correlated with the variation in sea salt components. Trace elements were generally higher in the yellow sand period; however, toxic heavy metals such as zinc, cadmium and lead were the highest in the polluted period.d.d.d.

Preliminary Study on Magnetic Resonance Temperature Measurement using Brain-Metabolite Phantom (뇌 대사물질 팬텀을 이용한 뇌의 자기공명 온도측정법에 관한 기초 연구)

  • Han, Yong-Hee;Jang, Moo-Young;Mun, Chi-Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.412-416
    • /
    • 2010
  • In this study, we measured the chemical shift change of metabolite peaks in the brain-metabolite phantom according to the temperature variation using nuclear magnetic resonance(NMR). The temperature range in NMR system was controled from 25 to 80 (5 step) by internal temperature controller. Temperature coefficients of each metabolite peaks were also calculated from the measured chemical shift depending on the temperature. The chemical shift changes depending on temperature were validated by linear regression method for each metabolite peaks. The temperature coefficients of $_{tot}Cr$, Cho, Cr, NAA, and Lac were 0.0086, 0.0088, 0.0091, 0.0089, and 0.0088ppm/$^{\circ}C$, respectively. This study shows that chemical shift change of brain metabolite and temperature variation have linear relationship each other. This also makes authors believe that brain temperature measurement is possible using MR spectroscopic imaging technique.

상동중석광산 광미에 함유된 중금속의 수직분포도 조사

  • 정명채;강만희;정문영;최연왕
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.52-55
    • /
    • 2003
  • The objective of this study is to investigate the vertical variation of heavy metals in tailings from the Sangdong W mine. Tailings samples were taken at 6 drilling sites with 50cm intervals up to 21meters in depth and dried at room temperature. The pH value, loss-on-ignition and water contents were measured. In addition, chemical compositions of the samples were determined by AAS after 0.1N HC1 leaching and ICP-AES after aqua regia leaching. The pH values were in the range of 7.2 to 8.5 due to chemical reactions of carbonate minerals. The ranges of heavy metals (mg/kg) extracted by 0.1N HC1 were from 0.17 to 0.93 for Cd, 0.04 to 4.39 for Cu, 0.03 to 10.9 for Pb and 0.06 to 14.1 for Zn and those extracted by aqua regia were 3.10~10.5, 23.61 ~251, 63.7~337 and 42.6~134 for Cd, Cu, Pb and Zn, respectively. Generally, the metal concentrations in tailings do not change with depth, with they have a tendency to decrease with depth in some case.

  • PDF

Thermal and Mineralogical Characterization of Ca-Montmorillonite from Gampo Area (감포지역(甘浦地域) Ca-몬모릴로나이트의 열적(熱的) 및 광물학적(鑛物學的) 특성(特性))

  • Moon, Hi-Soo;Choi, Sun Kyung;Kim, Moon Young
    • Economic and Environmental Geology
    • /
    • v.21 no.2
    • /
    • pp.175-184
    • /
    • 1988
  • Ten under 2 micron size fractions of the montmorillonite from Yongdongri area, Gyeongsangbug-Do were studied using X-ray powder diffraction, cation exchange measurement, differential thermal analysis, thermogravimetric analysis, differential thermal scanning calorimetry and chemical analysis. Montmorillonites occurring at same deposit show limited variation in chemical composition whereas in thermal properties they do not. Their dehydroxylation endothermic peaks are "abnormal" type with a small range of variation of peak temperature reflecting tetrahedral substitution of Al for Si. Data from DSC show that divalent-cation saturated montmorillonite has relatively a higher endothermic heat capacity than monovalent-cation saturated montmorillonite, indicating that cations with higher electronegativity hold more water molecules.

  • PDF

Variation of Inter-Ring Gas Pressure in Internal Combustion Engine (내연기관 피스톤 링들 사이 가스압력 변동)

  • Yun, J.E.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.238-249
    • /
    • 1995
  • The gas pressure acting on the rings in internal combustion engine influences the friction and wear characteristics. Inter-ring pressure variation during engine operation results from cylinder gas flow through a piston-ring pack. The flow passages consist of ring end gaps and clearances between the ring and the piston groove. The gas flow in the clearance between the ring and the groove is directly affected by the axial motion of the ring in the groove. In this paper the asperity contact force is newly considered in the prediction of the clearence between the ring and the groove surface. This term must be taken into account physically in case that the clearance get narrow rather than asperity height between the ring and the groove surface. Finally, comparisons of calculated inter-ring gas pressures based on the analytical method are made with the measured ones. The agereement was found to be good below midium engine speed, 3000rpm. In order to obtain accurate analytical results to the extend of high rpm range, it is recommended to include oil ring motion as well as top and second ring in analytical model.

  • PDF

A Conduction Band Control AC-DC Buck Converter for a High Efficiency and High Power Density Adapter (고효율, 고전력밀도 아답터를 위한 도통밴드 제어 AC-DC 벅 컨버터)

  • Moon, SangCheol;Chung, Bonggeun;Koo, Gwanbon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.38-39
    • /
    • 2017
  • This paper proposes a new control method for an AC-DC Buck converter which is utilized as a front-end converter of a 2-stage high power density adapter. In the conventional adapter applications, 2-stage configuration shows higher power transfer efficiency and higher power density than those of the single stage flyback converter. In the 2-stage AC-DC converter, the boost converter is widely used as a front-end converter. However, an efficiency variation between high AC line and low AC line is large. On the other hand, the proposed conduction band control method for a buck front-end converter has an advantage of small efficiency variation. In the proposed control method, switching operation is determined by a band control voltage which represents output load condition, and an AC line voltage. If the output load increasesin low AC line, the switching operation range is expanded in half of line cycle. On the contrary, in light load and high line condition, the switching operation is narrowed. Thus, the proposed control method reduces switching loss under high AC line and light load condition. A 60W prototype which is configured the buck and LLC converter with the proposed control method is experimented on to verify the validity of the proposed system. The prototype shows 92.16% of AC-DC overall efficiency and 20.19 W/in 3 of power density.

  • PDF

The Kinematic Comparison and Analysis between National Long Jumpers and Foreign long Jumpers with record of over 8 meter (국외 8m 이상 멀리뛰기 선수와 국내 선수들의 운동학적 비교 분석)

  • Ryu, Jae-Kyun;Chang, Jae-Kwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.133-142
    • /
    • 2005
  • The purpose of this study was to compare of the kinematic variables from takeoff preparation to takeoff used by long jumpers who recorded over 8meters in 2002 Busan Asian Game and 2003 Daegu Universiade and 2001 national championship. The kinematic characteristics from the last three stride to takeoff at the takeoff board were analyzed such as velocities, heights and angles. The conclusion were as follows; In order to record over 8meters the national long jumpers should have under 5cm height variation at the penultimate stride of the run-up. In the approach phase the horizontal velocity of the jumpers should reach to 10m/s in touchdown at takeoff board The vertical velocity must have 3.75m/s simultaneously in order to record 8meters. The jumpers need to continue talent of the horizontal velocity in touchdown at takeoff board and require jumping power of the takeoff leg at takeoff board The appropriate body variation range ratio between takeoff and touchdown should be 1.2 vs 1 and the trunk angle at touch down on the board should be close to the erect posture for higher body flight.