• Title/Summary/Keyword: Range control

Search Result 7,858, Processing Time 0.044 seconds

Description of crack growth behavior of SB41 steel in terms of J integral (J적분에 의한 SB41강의 피로균열 진전 특성 평가)

  • 배원호;김상태;이택순
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1568-1575
    • /
    • 1990
  • Fatigue crack growth behavior was investigated in the center cracked plate of KS SB41 steel and the relation between the crack growth rate and various mechanical parameters was studied at small scale yielding, large scale yielding and full scale yielding. The crack opening ratio U was about 0.6-0.8 and had the larger value in the case of load control than that of strain control. Effective stress intensity factor range, .DELTA.K$_{eff}$ and J integral range, .DELTA.J were obtained from the notion of crack opening, and the crack growth rate was expressed with these values. The value of J integral range increased rapidly at stress ratio, R=0 in full scale yielding of load control test. COD value also increased rapidly with the increase of ligament net stress at large scale yielding of load control test.t.

Stereotype for Control-display Relationship of Four-burner Range for Korean

  • Kee, Do-Hyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.389-394
    • /
    • 2011
  • The aims of this study are to investigate the Korean population stereotype for control-display linkage of four-burner gas-range, and to compare the results of this study with those of the existing studies. The investigation used a paper-pencil test using questionnaire with a sign code system for eliminating suggestive effect of sequential code. Two hundreds and eighty subjects participated in the investigation, among whom 254 subjects effectively responded to question for the gas-range stereotype. The results showed that type III(refer to Table 2) was chosen more frequently than type II, IV and V(p<0.01). The gender is not significant on responding rate for the type of control-burner linkage(p>0.92), while the age and occupation have significant effect on the rate(p<0.01). Based on this study, it appears that type III represents the population stereotype of control-burner arrangement for Korean. The stereotype was the same as that of Chinese, but different from that of American(type II or IV). The findings of this study would be helpful as basic data for ergonomically designing gas-range or similar products.

Accuracy of Paper-pencil Test used in Investigation of Control-display Stereotype - Focused on Stereotype for Control-burner Relationship of Four-stove Range - (조종장치-표시장치 스테레오타이프 조사를 위한 설문조사법의 정확성 - 4구 가스렌지 조종장치-버너 연결에 대한 스테레오타이프를 중심으로 -)

  • Kee, Dohyung
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.114-117
    • /
    • 2013
  • The purpose of this study is to empirically investigate accuracy of paper-pencil test used in surveying control-display stereotype. For doing this, three paper-pencil tests dealing with stereotype for control-burner relationship of four-stove gas range, in which three different gas range images were provided, were performed and the results were compared with those of existing studies. The result of the paper-pencil test using simple image composed of line and circle was different from that of the real model simulation, while the results of the other two tests and a previous study providing more realistic images were the same as that of the real model simulation. Furthermore, the proportion of responses coinciding with the real model simulation increased as images used became closer to real range. It is concluded that the paper-pencil tests well designed using realistic images may produce the same stereotype as the real model simulation.

Operating Characteristics Analysis Of Bi-Directional DC/DC Converter using PFM control with high efficiency at whole load range (전 부하 영역에서 고효율을 가지는 PFM 제어를 이용한 양방향 DC/DC 컨버터의 동작특성 분석)

  • Kim, Ji-Hwan;Hwang, Sun-Hee;Ryu, Dong-Gyun;Jung, Doo-Yong;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.29-30
    • /
    • 2012
  • In this paper, a performance of bi-directional DC/DC converter using PFM control at whole load range is analyzed. A bi-directional DC/DC converter using PFM control in this paper can be soft switching operation with LC series resonant circuit. It's difficult to expect a high efficiency at whole load range in general resonant converter because of limitation of soft switching area. Therefore converter used in this paper has a variable frequency PFM control to overcome a limitation of soft switching area and it makes a high efficiency at whole load range by implementing a soft switching at light load area of restricted soft switching. The high efficiency at whole load range is verified by simulation and experimental result.

  • PDF

A study for the system voltage and reactive power control (계통전압.무효전력 제어에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.14 no.3
    • /
    • pp.10-17
    • /
    • 1965
  • This paper presents a method of the voltage-reactive power control in the long and short range operations and introduces a conception, "optimum control pattern." The optimum control pattern, aiming at the over-all system control, is defined as the optimum voltage distribution which minimizes the system operating cost under the conditions that the specified power be supplied and the system voltage be kept within the specified bounds. The following procedure was adopted to obtain this optimum pattern. In the first place, a power system was divided into three blocks, namely, load, substation and generator. Lagrange's, multiplier method is applied to each block in turn, paying attention only at the operating voltage distribution. Phase angles at each bus are then modified so that the continuity of active power is maintained. This procedure may be called "block relaxation method with Lagrange's multipliers." In a long range operation, this control pattern determines the optimum installation capacity of reactive power sources. In a short range operation, it also gives the reference state of real time control and the optimum switching capacity of reactive power souces. The real time control problem is also studied from the standpoint of cooperation of control devices such as generators, shunt capacitors, shunt reactors and ratio load controllers. A proposal for the real time control will contribute to the automation of power system operation in the near future. in the near future.

  • PDF

A study on Sensorless Vector Control for Spindle Induction Motor (스핀들용 유도전동기 센서리스 벡터제어에 관한 연구)

  • Park, S.H.;Yoon, J.M.;You, J.S.;Shin, S.C.;Won, C.Y.;Choi, C.;Lee, S.H.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.119-124
    • /
    • 2004
  • A new control method of spindle induction motor drive is proposed in this paper. In a conventional control method, the vector control was employed in the low speed range, while the constant V/f(volt-per-hertz) PWM control was employed in the high speed range. The two control modes were automatically selected at an intermediate speed. In a proposed control method, the direct vector-control with an encoder is employed in the low speed range(from 0 to 8,000rpm), and the vector control without an encoder is employed in th high speed(from 8,000 to 15,000rpm) by using flux observer and speed estimator. This paper describes problem of control method in a conventional spindle induction motor drive and proposes contort method as variation of motor speed.

  • PDF

Design of the Anti-windup and Bumpless Transfer Controller with Application to Nonlinear Boiler Systems (누적방지 무충돌 전환 제어기의 설계와 비선형 보일러 시스템 적용)

  • Lee, Young-Sam;Lee, Myung-Eui;Kwon, Oh-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.4
    • /
    • pp.247-253
    • /
    • 2000
  • In this paper, we deal with the full range control problem of nonlinear boiler systems subject to complex actuator constraints. Firstly, $H\infty$ loop shaping design procedure[10] is used for the controller design. Secondly, modified high-gain feedback[11] for the loop shaping controller is adopted for the anti-windup function and the bumpless transfer technique between controllers is proposed for the full range control of nonlinear systems. Finally, the performance of the proposed controller is demonstrated through the simulation studies.

  • PDF

Control Valve Positioner and Its effect on a Gas Turbine MW Control (공정제어루프 최종 조작부의 동작특성에 관한 연구)

  • Kim, Jong-An;Shin, Yoon-Oh
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.728-730
    • /
    • 1998
  • The control valve positioner is a high gain plain proportional controller which measures the valve stem position and compares it to its setpoint which is the primary controller output. The positioner in effect is the cascade slave of the primary controller. In order for a cascade slave to be effecttive, it must be fast enough compared to the speed of its set point change. This paper describes the positioner transfer function and its effect on the entire control loop characteristic based on the simulation results. The result showed that the control valve and positioner determined the gain and phase angle in the high frequency range, while the primary controller and process determined those of the low frequency range. We can also anticipate the combined characteristics in the whole frequency range when each element's frequency response is known.

  • PDF

A Study on the Mode Conversion of Control in the Single Phase Switched Reluctance Motor (단상 SRM의 제어 모드 변환에 관한 연구)

  • Go, Sung-Chul;Ahn, Joon-Seon;Kim, Sol;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.635-636
    • /
    • 2006
  • A pulse with modulation(PWM) that keeps a constant angle of dwell and adjust duty ratio is a good method to control a speed of SRM. And a method of one pulse control is proper a operation on range of high speed in SRM for a good energy efficiency. Because PWM method is more safety than one pulse method, conversion of those is best choice according the speed range. So, some algorithm is need for smooth conversion of the mode of control. This paper presents a factor of conversion that proper the conversion of control mode between PWM and one pulse method This factor is from estimation of torque and proper at the variable range of conversion and show the better conversion characteristic than constant factor of conversion.

  • PDF

A Study on the Improvement of Optimal Load Range for Sliding Pressure Operation of coal-fired Power Plant (석탄화력 발전소 최적 변압운전 부하 범위 개선에 대한 연구)

  • Lee, Sang-Hun;Wang, Min-Seok;Wee, Sang-Bong;Son, Yung-Deug
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.675-680
    • /
    • 2019
  • The coal-fired power plant is operated by a combined operation method, which is operated by sliding pressure operation under low load and by fixed pressure operation under high load for improved efficiency. The combined operation is divided into two and three valve open modes. Each plant is operated by selecting the turbine control valve mode in accordance with the manufacturer's recommendation, but is not really operating at the optimal sliding pressure operation according to load range, also Load range of each plant is configured differently. The internal efficiency of the high-pressure turbines is reduced due to loss of the turbine valves and the plant efficiency is reduced. To solve these problems, In this paper, the optimum load range is selected through the analysis method of thermal performance by each load in order to improve the optimum variable pressure operation load range by turbine control valve mode.