• 제목/요약/키워드: Range Compensator

검색결과 96건 처리시간 0.027초

분산전원이 연계된 배전계통에 있어서 선로전압조정장치(SVR)의 전압제어 개선방안 (Improvement Method of SVR Control in Power Distribution System Interconnected Distributed Generator)

  • 이현옥;허재선;김병기;노대석;김재철
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.224-229
    • /
    • 2014
  • This paper presents the novel voltage control method in power distribution system with distributed generators. The voltage in distribution systems is regulated by Under Load Tap Changer(ULTC) of substation and pole transformer of primary feeders. Recently, Step Voltage Regulator(SVR) is getting located at distribution feeders to regulate effectively voltage of primary feeders. But the effectiveness of SVR decreases due to independent operation between SVR and ULTC, and also the existing Line Drop Compensator(LDC) method considering the distributed generators may be not able to regulate the proper voltage in a permissible range. Thus, this paper presents a optimal voltage control algorithm of SVR by using the secondary voltage data of main transformer in substation.

전력조류계산을 위한 SSSC모델의 개발과 연속조류계산 알고리듬에의 적용 (Development of SSSC Power Flow Model and its Implementation into Continuation Power Flow Algorithm)

  • 김슬기;송화창;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1158-1160
    • /
    • 1999
  • This paper proposes a SSSC(Static Synchronous Series Compensator) power flow model to be incorporated into power flow calculation for the steady state analysis of the power system. SSSC provides controllable compensating voltage, which is in quadrature with the line current, over an capacitive and an inductive range, independently of the magnitude of the line current. This SSSC model is obtained from the injection model for series connected VSC(Voltage Source Converter) by adding a constraint that the injected voltage should be in quadrature with the line current. In this paper the static model is implemented into the continuation power-flow (CPF) program. It is shown that SSSC has its intrinsic superiority over TCSC in controllable power flow range.

  • PDF

Phase-Locked Loop with Leakage and Power/Ground Noise Compensation in 32nm Technology

  • Kim, Kyung-Ki;Kim, Yong-Bin;Lee, Young-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권4호
    • /
    • pp.241-246
    • /
    • 2007
  • This paper presents two novel compensation circuits for leakage current and power supply noise (PSN) in phase locked loop (PLL) using a nanometer CMOS technology. The leakage compensation circuit reduces the leakage current of the charge pump circuit and the PSN compensation circuit decreases the effect of power supply variation on the output frequency of VCO. The PLL design is based on a 32nm predictive CMOS technology and uses a 0.9 V power supply voltage. The simulation results show that the proposed PLL achieves 88% jitter reduction at 440 MHz output frequency compared to the PLL without leakage compensator and its output frequency drift is little to 20% power supply voltage variations. The PLL has an output frequency range of 40 $M{\sim}725$ MHz with a multiplication range of 1-1023, and the RMS and peak-to-peak jitter are 5psec and 42.7 psec, respectively.

SPEED SENSORLESS FIELD-ORINTED CONTROL OF INDUCTION MOTORS WITH AN IMPROVED FLUX ESTMATOR

  • Shin, Myoung-Ho;Hyun, Dong-Seok;Cho, Soon-Bong;Choe, Song-Yul
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.392-397
    • /
    • 1998
  • This paper proposes a programmable low pass filter(LPF) to estimate stator flux for speed sensorless stator flux orientation control of induction motors. The programmable LPF is developed to solve the dc drift problem associated with a pure integrator and a LPF with fixed pole. The pole of the programmable LPF is located far from the origin to decrease the time constant as speed increases. The programmable LPF has the phase and the magnitude compensator to exactly estimate stator flux in a wide speed range. So, the drift problem is much improved and the stator flux is exactly estimated in the wide speed range.

  • PDF

개선된 고정자 자속 추정을 통한 유도전동기의 속도센서리스 벡터제어 (Speed Sensorless Vector Control of Induction Motors with an Improved Stator Flux Estimator)

  • 신명호;현동석;조순봉;최종률
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.371-375
    • /
    • 1998
  • This paper proposes a programmable low pass filter(LPF) to estimate stator flux for speed sensorless stator flux orientation control of induction motors. The programmable LPF is developed to solve the dc drift problem associated with a pure integrator and an analog LPF with fixed pole. of the programmable LPF is located far from the origin in order to decrease the time constant as speed increases. The programmable LPF has the phase and the magnitude compensator to exactly estimate stator flux in a wide speed range. So, the drift problem is much improved and the stator flux is exactly estimated in the wide speed range. The validity of the proposed programmable LPF is verified by speed sensorless vector control of a 2.2[kW] three-phase induction motor.

  • PDF

2축 시스템의 비대칭 윤곽제어 (Asymmetrical Contouring Control of Biaxial System)

  • 이건복;심영복;정유철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.277-282
    • /
    • 1996
  • An asymmetrical cross-coupled compensator to improve the contouring performance is proposed. This is a refinement of the structure suggested by Koren. The position loop is closed with a proportional controller as in the uncoupled system. An additional input term proportional to the component of the contour error along the corresponding axis Is included. The controller gains are chosen to give an appropriate frequency response and an optimum range for the damping ratio. The effectiveness of the proposed controller is studied by means of digital simulations of the dynamics of the drives and the controller for 3 types of command trajectories; straight line contour, cornering contour, circular contour. Substantial improvement in contouring performance is obtained for a range of contouring conditions.

  • PDF

2축 시스템의 비대칭 윤곽제어 (Asymmetrical Contouring Control of Biaxial System)

  • 심영복;정유철;이건복
    • 한국정밀공학회지
    • /
    • 제14권8호
    • /
    • pp.65-72
    • /
    • 1997
  • An asymmetrical cross-coupled compensator to improve the contouring performance is proposed. This is a refinement of the structure suggested by Koren. The position loop is closed with a proportional controller as in the uncoupled system. An additional input term proportional to the component of the contour error along the corresponding axis is included. The controller gains are chosen to give an appropriate frequency response and an optimum range for the damping ratio. The effectiveness of the proposed controller is studied by means of digital simulations of the dynamics of the drives and the controller for 4 types of command trajectories: straight line contour, cornering contour, circular contour, elliptic contour. Substantial improvement in contouring performance is obtained for a range of contouring conditions.

  • PDF

Coordination Control of Voltage Between STATCOM and Reactive Power Compensation Devices in Steady-State

  • Park, Ji-Ho;Baek, Young-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.689-697
    • /
    • 2012
  • This paper proposes a new coordinated voltage control scheme between STATCOM (Static Synchronous Compensator) and reactive power compensation devices, such as shunt elements(shunt capacitor and shunt reactor) and ULTC(Under-Load Tap Changer) transformer in a local substation. If STATCOM and reactive power compensators are cooperatively used with well designed control algorithm, the target of the voltage control can be achieved in a suddenly changed power system. Also, keeping reactive power reserve in a STATCOM during steady-state operation is always needed to provide reactive power requirements during emergencies. This paper describes the coordinative voltage control method to keep or control the voltage of power system in an allowable range of steady-state and securing method of momentary reactive power reserve using PSS/E with Python. In the proposed method of this paper, the voltage reference of STATCOM is adjusted to keep the voltage of the most sensitive bus to the change of loads and other reactive power compensators also are settled to supply the reactive power shortage in out range of STATCOM to cope with the change of loads. As the result of simulation, it is possible to keep the load bus voltage in limited range and secure the momentary reactive power reserve in spite of broad load range condition.

원자힘 현미경 융합형 마이크로스폿 분광타원계 개발 (Development of a Microspot Spectroscopic Ellipsometer Compatible with Atomic Force Microscope)

  • 인선자;이민호;조성용;홍준선;백인호;권용현;윤희규;김상열
    • 한국광학회지
    • /
    • 제33권5호
    • /
    • pp.201-209
    • /
    • 2022
  • 기존 마이크로스폿 분광타원계의 집속광학계를 개선하여 원자힘 현미경(atomic force microscope, AFM) 헤드를 장착할 수 있도록 한 AFM 융합형 마이크로스폿 분광타원계를 개발하였다. 빔의 워블에 의한 영향을 최소화하기 위해 편광자-시료-보정기-검광자 배치에서 회전보정기 구동방식을 채택하고 이상적인 4분파장 위상지연 특성으로부터 벗어나는 비색성 위상지연자를 사용할 수 있도록 측정이론을 제시하였다. 개발된 마이크로스폿 분광타원계는 AFM 헤드를 장착한 상태에서도 20 ㎛ 이하의 스폿 사이즈를 가지며 190-850 nm의 파장대역에 걸쳐 구동하고 δΔ ≤ 0.05°와 δΨ ≤ 0.02°의 측정정밀도를 가지는 것을 확인하였다. 연속회전하는 스테핑 모터의 속도와 분광계를 정밀하게 동기화시켜 ≤3 s/sp의 빠른 측정속도를 구현하였다. AFM과 융합된 마이크로스폿 분광타원계는 초미세 패턴시료의 구조 및 광학물성 분석에 유용하게 사용될 수 있을 것으로 기대한다.

양성자 치료계획에서 fiducial marker의 density override 방법에 따른 선량변화 비교 : Planning study (Comparing the dosimetric impact of fiducial marker according to density override method : Planning study)

  • 성두영;박세준;박지현;박용철;박희철;최병기
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.19-26
    • /
    • 2017
  • 목 적: 양성자 치료계획에서 metal 재질의 fiducial marker에 의한 선량 계산오차를 최소화하려면 density override의 적용은 매우 중요하다. 하지만 실제 metal 재질로 density override을 할 경우 정확한 contouring 및 range compensator 제작에 어려움이 있기에 본 연구에서는 fiducial marker의 주변 재질로 density override를 시행하고 fiducial marker의 위치, 재질, beam의 개수에 따른 선량분포를 비교, 분석하여 평가하고자 한다. 대상 및 방법: Water phantom을 이용하여 fiducial marker의 위치를 proton beam의 최대 비정 끝에서부터 1.5, 2.5, 4.0, 6.0 cm로 설정하고 재질로는 gold, steel, titanium으로 설정하여 실제 metal 재질 및 주변 재질로 density override를 적용한 치료계획을 세웠다. 또한 본원에서 양성자치료를 받은 간암 환자 1명을 선정하여 proton beam의 최대 비정 끝에서부터 0, 1.5, 3.5 cm로 설정하고 재질로는 gold, steel, titanium으로 설정하여 치료계획을 세웠다. Fiducial marker의 재질, 위치 및 beam의 개수에 따른 PTV 내에 Homogeneity Index(HI), Conformity Index(CI), 종양에 가장 근접한 Organ At Risk(OAR)인 Esophagus의 maximum dose을 평가 지표로 설정하고 비교 분석하였다. 결 과: Water phantom 및 간암 환자를 대상으로 한 치료계획에서 fiducial marker의 위치에 따른 Homogeneity Index를 분석한 결과 실제 metal 재질로 density override 했을 때보다 주변 재질로 density override했을 때 Homogeneity Index가 감소했으며 주변 재질의 density override에서 하나의 beam에 대해서는 최대 비정 끝에서 멀리 위치할수록, 두 개 이상의 beam에서는 isocenter에 가까이 위치할수록 Homogeneity Index가 증가하였다. Fiducial marker의 위치에 따른 Conformity Index 및 종양 주위 OAR의 maximum dose를 분석한 결과 주변 재질로 density override 했을 때 Conformity Index는 1에 가까웠으며 OAR의 maximum dose는 크게 감소했다. 결 론: 일반적으로 임상에서 사용하는 작은 fiducial marker에 대해서 실제 metal 재질이 아닌 주변 재질로 density override 했을 때 선량 균등도 및 target coverage를 높이는 동시에 주변 정상조직에 대한 선량을 줄일 수 있었다. 따라서 fiducial marker을 최대한 피해서 치료계획을 세우는 것이 바람직하지만 beam path 상에 fiducial marker가 있는 경우 주변 재질의 density override 시행함으로써 보다 정밀한 양성자 치료 효과를 기대할 수 있을 것으로 사료된다.

  • PDF