• Title/Summary/Keyword: Ramp compensation

Search Result 14, Processing Time 0.009 seconds

Sampled-Data Modeling and Dynamic Behavior Analysis of Peak Current-Mode Controlled Flyback Converter with Ramp Compensation

  • Zhou, Shuhan;Zhou, Guohua;Zeng, Shaohuan;Xu, Shungang;Cao, Taiqiang
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.190-200
    • /
    • 2019
  • The flyback converter, which can be regarded as a nonlinear time-varying system, has complex dynamics and nonlinear behaviors. These phenomena can affect the stability of the converter. To simplify the modeling process and retain the information of the output capacitor branch, a special sampled-data model of a peak current-mode (PCM) controlled flyback converter is established in this paper. Based on this, its dynamic behaviors are analyzed, which provides guidance for designing the circuit parameters of the converter. With the critical stability boundary equation derived by a Jacobian matrix, the stable operation range with a varied output capacitor, proportional coefficient of error the amplifier, input voltage, reference voltage and slope of the compensation ramp of a PCM controlled flyback converter are investigated in detail. Research results show that the duty ratio should be less than 0.5 for a PCM controlled flyback converter without ramp compensation to operate in a stable state. The stability regions in the parameter space between the output capacitor and the proportional coefficient of the error amplifier are enlarged by increasing the input voltage or by decreasing the reference voltage. Furthermore, the ramp compensation also can extend to the stable region. Finally, time-domain simulations and experimental results are presented to verify the theoretical analysis results.

A study on the ramp tracking servo controller using nonlinear friction compensator (비선헝 마찰 보상기를 이용한 램프추종 서보제어기에 관한 연구)

  • Choi, Seung-Hwan;Lim, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.426-428
    • /
    • 1998
  • In this paper, a ramp tracking controller design method is proposed for the systems with nonlinear frictions. The objective is to design a controller which is capable of tracking a ramp reference input without steady state error. The controller is composed of a linear controller, integrators for error compensation, and a friction compensator. The compensator estimates the parameters of friction model. The friction parameters are estimated using two different method. Simulation and experimental results show that the proposed method is effective.

  • PDF

Peak-Valley Current Mode Controlled H-Bridge Inverter with Digital Slope Compensation for Cycle-by-Cycle Current Regulation

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.1989-2000
    • /
    • 2015
  • In this paper, digital peak current mode control for single phase H-bridge inverters is developed and implemented. The digital peak current mode control is achieved by directly controlling the PWM signals by cycle-by-cycle current limitation. Unlike the DC-DC converter where the output voltage always remains in the positive region, the output of DC-AC inverter flips from positive to negative region continuously. Therefore, when the inverter operates in negative region, the control should be changed to valley current mode control. Thus, a novel control logic circuit is required for the function and need to be analyzed for the hardware to track the sinusoidal reference in both regions. The problem of sub-harmonic instability which is inherent with peak current mode control is also addressed, and then proposes the digital slope compensation in constant-sloped external ramp to suppress the oscillation. For unipolar PWM switching method, an adaptive slope compensation in digital manner is also proposed. In this paper, the operating principles and design guidelines of the proposed scheme are presented, along with the performance analysis and numerical simulation. Also, a 200W inverter hardware prototype has been implemented for experimental verification of the proposed controller scheme.

The Development of Control Algorithms of D-STATCON for Compensations of AC Voltage and DC Link Voltage and Harmonics Improve the Qeality of Electric Power (전력 품질 향상을 위한 배전용 STATCON의 AC전압, 직류결합 전압 및 고조파 보상 제어알고리즘 개발)

  • 오관일;전영수;이기선;추진부
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.333-337
    • /
    • 1999
  • This paper presents the DQ transfomation space space vector modulation method to devel control algorithm of distribu STATCON(STATic CONdenser) for line volt regulation, dc link voltage regulation harmonics compensation. The Performance an of a PI with ramp comparision and synchro reference frame current controller is carried Based on these analysis, the control perform are desirable to compensate the harmonics a regulate dc link and line voltage of Distrib line.

  • PDF

A High Performance Current Control Stratege for a BLDC Motor (BLDC 전동기를 위한 고성능 전류 제어 기법)

  • Kim, Sang-Hoon;Kim, Jin-Yong
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.125-132
    • /
    • 2002
  • In this paper, a high performance current control strategy for a Brushless DC Motor is presented. The proposed strategy is based on the ramp comparison PI current control with the predictive voltage compensation. The proposed strategy is compared with the hysteresis current control strategy. The proposed method can improve the current waveforms, and it can reduce the torque ripples. So the proposed strategy is suitable to a high performance current control strategy for a Brushless DC Motor. The simulation and experimental results for a laboratory Brushless DC motor drive system confirm the validity of the proposed strategy.

  • PDF

Compensation of Addressing Time at High Temperature in ac PDP.

  • Choi, Joon-Young;An, Jung-Soo;Kim, Hun-Hee;Lee, Ho-Jun;Lee, Hea-Jun;Kim, Dong-Hyun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.164-170
    • /
    • 2004
  • Misfiring is often observed during the high temperature quality assurance test of plasma display panel. This limits the productivity of PDP industry. In this paper, experimental observations on the misfiring at high panel temperature have been performed through time dependent discharge light output and static margin measurement. For the high temperature condition, firing voltage increment is found in both surface and facing discharges. This in turn increases time lag in address discharge, and results in increment of misfiring probability. In order to reduce this kind of misfiring, a new method that applies automatically different slope of ramp erasing pulse on the common electrode according to temperature variation is proposed. The experimental results show that controlling the slope of ramp erasing pulse is quite effective for compensating temperature-dependent variation of reset and address discharge.

  • PDF

Development of Control Algorithm of D-STATCON(Distribution STATic-CONden: Compensations of Voltage Flicker and Harmonics (전압 플리커 및 고조파 보상을 위한 배전용 STATCON의 제어알고리즘 개발)

  • Jeon, Y.S.;Oh, K.I.;Lee, K.S.;Choo, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1282-1286
    • /
    • 1999
  • This paper presents the DQ transfomation and space vector modulation method to develop a control algorithm of distribution STATCON(STATic CONdenser) for line voltage regulation, dc link voltage regulation and harmonics compensation. The Performance analysis of a PI with ramp comparision and synchronous reference frame current controller is carried out. Based on these analysis, the control performances are desirable to compensate the harmonics and to regulate de link and line voltage of Distribution line.

  • PDF

Neutral Line Current Compensation Method of Active Power Filter (전력용 능동 필터의 중성선 전류 저감 기법)

  • Min, Joon-Ki;Kim, Hyo-Sung;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.504-506
    • /
    • 2005
  • This paper proposes a new neutral current reduction method using PQR instantaneous power theory on the active power filter, unbalanced nonlinear load condition in three-phase four-wire systems. For reduction of neutral line current, the single phase active power filter is used and its performance is same with the three-phase four-wire active power filter. For fully-digital implementation, ramp comparison PWM method was adopted. Simulation results verify good performance of the proposed current control strategy on the shunt APFs.

  • PDF

A Study of Average Current Mode Control Boost Converter for Space Craft Power System (인공위성용 전원을 위한 평균전류형 제어 BOOST 컨버터에 관한 연구)

  • Kim, H.J.;Kim, Y.T.;Kim, I.G.;Choi, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.886-888
    • /
    • 1993
  • Recently current mode control is widely adopted in switching power converter because of inherent stablity and ability of parallel operating. There are several ways in current mode control. One of them, peak current control is chiefly employed. Peak current mode control converter usually senses and controls peak inductor current. But there is peak-to-average current errors. Therefore peak current control needs compensation ramp correcting the errors. Average current mode control eliminates these problems, and is constructed by simple structures. This paper will describe the behavior of a simple average current mode boost converter and introduce the design techniques.

  • PDF

Development of DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle (하이브리드 자동차 보조전원 공급용 DC-DC 컨버터 개발)

  • Kim, Jong-Cheol;Choi, Deok-Kwan;Park, Hae-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.261-265
    • /
    • 2005
  • This paper describes the DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle. DC-DC Converter is used for charging 12V auxiliary battery supplying electric power to head ramp, audio, ECU etc in automobiles. used DC-DC Converter Topology is PS-ZVS FB(Phase Shifted Zero Voltage Switching Full-Bridge) to reduce switching loss and EMI noise induced by high frequency operating condition. And For easy compensation and stable system response characteristic, current mode control method including slope compensation is employed. Constant current / constant voltage charging control method guarantee stable electric charging of auxiliary battery. Simulation toll PSIM6.0 is used for initial circuit parameter settings and H/W debuging. Thermal problems of Switching components in DC-DC Converter is improved by using Thermo Tracer.

  • PDF