• Title/Summary/Keyword: Raman 분석

Search Result 486, Processing Time 0.025 seconds

A Baseline Correction for Effective Analysis of Alzheimer’s Disease based on Raman Spectra from Platelet (혈소판 라만 스펙트럼의 효율적인 분석을 위한 기준선 보정 방법)

  • Park, Aa-Ron;Baek, Sung-June
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.1
    • /
    • pp.16-22
    • /
    • 2012
  • In this paper, we proposed a method of baseline correction for analysis of Raman spectra of platelets from Alzheimer's disease (AD) transgenic mice. Measured Raman spectra include the meaningful information and unnecessary noise which is composed of baseline and additive noise. The Raman spectrum is divided into the local region including several peaks and the spectrum of the region is modeled by curve fitting using Gaussian model. The additive noise is clearly removed from the process of replacing the original spectrum with the fitted model. The baseline correction after interpolating the local minima of the fitted model with linear, piecewise cubic Hermite and cubic spline algorithm. The baseline corrected models extract the feature with principal component analysis (PCA). The classification result of support vector machine (SVM) and maximum $a$ posteriori probability (MAP) using linear interpolation method showed the good performance about overall number of principal components, especially SVM gave the best performance which is about 97.3% true classification average rate in case of piecewise cubic Hermite algorithm and 5 principal components. In addition, it confirmed that the proposed baseline correction method compared with the previous research result could be effectively applied in the analysis of the Raman spectra of platelet.

A Review of SERS for Biomaterials Analysis Using Metal Nanoparticles (바이오 물질 분석을 위한 금속 나노입자를 이용한 SERS 분석 연구동향)

  • Jang, Eue-Soon
    • Ceramist
    • /
    • v.22 no.3
    • /
    • pp.281-300
    • /
    • 2019
  • Surface enhanced Raman scattering (SERS) was first discovered in 1974 by an unexpected Raman signal increase from Pyridine adsorbed on rough Ag electrode surfaces by the M. Fleishmann group. M. Moskovits group suggested that this phenomenon could be caused by surface plasmon resonance (SPR), which is a collective oscillation of free electrons at the surface of metal nanostructures by an external light source. After about 40 years, the SERS study has attracted great attention as a biomolecule analysis technology, and more than 2500 new papers and 500 review papers related to SERS topic have been published each year in recently. The advantages of biomaterials analysis using SERS are as follows; ① Molecular level analysis is possible based on unique fingerprint information of biomolecule, ② There is no photo-bleaching effect of the Raman reporters, allowing long-term monitoring of biomaterials compared to fluorescence microscopy, ③ SERS peak bandwidth is approximately 10 to 100 times narrower than fluorescence emission from organic phosphor or quantum dot, resulting in higher analysis accuracy, ④ Single excitation wavelength allows analysis of various biomaterials, ⑤ By utilizing near-infrared (NIR) SERS-activated nanostructures and NIR excitation lasers, auto-fluorescence noise in the visible wavelength range can be avoided from in vivo experiment and light damage in living cells can be minimized compared to visible lasers, ⑥ The weak Raman signal of the water molecule makes it easy to analyze biomaterials in aqueous solutions. For this reason, SERS is attracting attention as a next-generation non-invasive medical diagnostic device as well as substance analysis. In this review, the principles of SERS and various biomaterial analysis principles using SERS analysis will be introduced through recent research papers.

Thermal Annealing Effect on the Machining Damage for the Single Crystalline Silicon (단결정 실리콘의 기계적 손상에 대한 열처리 효과)

  • 정상훈;정성민;오한석;이홍림
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.8
    • /
    • pp.770-776
    • /
    • 2003
  • #140 mesh and #600 mesh wheels were adopted to grind (111) and (100) oriented single crystalline silicon wafer and the grinding induced change of the surface integrity was investigated. For this purpose, microroughness, residual stress and phase transformation were analyzed for the ground surface. Microroughness was analyzed using AFM (Atomic Force Microscope) and crystal structure was analyzed using micro-Raman spectroscopy. The residual stress and phase transformation were also analyzed after thermal annealing in the air. As a result, microroughness of (111) wafer was larger than that of (100) wafer after grinding. It was observed using Raman spectrum that the silicon was transformed from diamond cubic Si-I to Si-III(body centered tetragonal) or Si-XII(rhombohedral). Residual stress relaxation was also shown in cavities which were produced after grinding. The thermal annealing was effective for the recovery of the silicon phase to the original phase and the residual stress relaxation.

Study on the properties of aluminum nitride sintered using an induction furnace without sintering additives (소결조제 없이 유도가열로를 이용해 소결된 질화알루미늄의 특성 연구)

  • Hyo Min Choi;Kyung-Pil Yin;Jong-Won Yoon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.34 no.3
    • /
    • pp.98-102
    • /
    • 2024
  • In this study, the crystal characteristics of commercial AlN powders with sizes of "㎛" and "nm" were selected through XRD analysis and then sintered at different temperatures through an induction heating furnace to investigate the optimized sintering temperature and physical properties. The sintering temperature was 1,500, 1,700, and 1,900℃ in the N2 atmosphere, and the optimized sintering temperature conditions were established for the sintered AlN pellets using SEM, XRD, and Raman analysis. Additionally, impedance analysis was performed to confirm the electrical properties of the optimized AlN pellet without sintering additives.

Identification of Microplastics in Sea Salts by Raman Microscopy and FT-IR Microscopy (라만 및 FT-IR 현미경을 이용한 천일염 중 미세플라스틱 분석)

  • Cho, Soo-Ah;Cho, Won-Bo;Kim, Su-Bin;Chung, Jae-Hak;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.243-251
    • /
    • 2019
  • Microplastics (MP) are found in large quantities in the oceans, posing a major threat to the ecosystem. In Korea, MPs have been reported to be detected in sea salts. In order to analyze MPs, information on their composition, size, and shape is required. FT-IR microscopy is used frequently to measure sizes larger than 20 ㎛. Recently, however, Raman microscopy, which can analyze ultrafine plastics below 20 ㎛, has been applied extensively. In this study, 10.0 g samples of commercially available salts were dissolved and filtered through a 45 ㎛ mesh filter with a size of 25.4 mm × 25.4 mm. These filtered samples were then analyzed by both FT-IR microscopy and Raman microscopy. A total of four MPs, including three polyethylene (PE) of size 70-100 ㎛ and a polypropylene (PP) of size 170 ㎛, were detected by FT-IR microscopy, while 10 MPs, including nine PE of size 10-120 ㎛ and one polystyrene (PS) of size 40 ㎛, were detected by Raman microscopy. Approximately, 1,000 MPs/kg was estimated, which was almost two times higher than the previous reported levels (~550-681 particles/kg in sea salts); this is because Raman microscopy can detect much smaller MPs than FT-IR microscopy. A total of 113 particles were found using Raman microscopy: Carbon (35, 31.5 %), minerals (28, 25 %), and glass (16, 14.4 %) were dominant, forming around 70% of the total, but MPs (10, 8.8 %) and cellulose (5, 4.5 %) were also found. Raman microscopy has great potential as an accurate method for measuring MPs, as it can measure smaller size MPs than FT-IR microscopy. It also has a reduced sample preparation time.

Study on the Possibility of Recycling Crankcase Soot from Diesel Engine (디젤 엔진에서 생성된 크랭크케이스 수트의 재활용 가능성 연구)

  • Kim, Soo-yang;Choi, Jae-Hyuk;Rho, Bum-Seok;Kim, Junsoo;Kang, Jun;Lee, Won-Ju
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.179-186
    • /
    • 2021
  • In this study, we attempted to comparatively analyze the structural characteristics of soot generated from marine engines to review the possibility of recycling crankcase soot by classifying it as exhaust soot and crankcase soot. The annealing procedure was performed in an argon gas atmosphere at 2,000℃ and 2,700℃, and Raman spectroscopy and High-Resolution Transmission Electron Microscopy(HRTEM) were used to analyze the structural properties of the samples. Furthermore, digital image processing techniques were utilized to quantitatively analyze the acquired HRTEM images. The Raman analysis demonstrated a relatively high G/D ratio in the exhaust soot and annealing conditions at 2,700℃. In the HRTEM images, both soot were able to identify similar forms of graphite nanostructures, but there were limitations in that they could not quantitatively derive differences in the degree of graphite depending on the type of soot and annealing temperature. Thus, digital image processing quantitatively analyzed the length and tortuosity of the fringe of the HRTEM image, which is consistent with the Raman analysis. This meant that the exhaust soot had a more graphite structure than the crankcase soot, and that annealing at a higher temperature improved the graphite structure. This study confirmed that both the crankcase soot and exhaust soot can be recycled as a graphite materials.

Effects of silicon-on-insulator(SOI) substrates on the residual stress within 3C-SiC/Si thin films (Silicon-on-insulator(SOI) 기판이 3C-SiC/Si 박막 내의 잔류응력에 미치는 영향)

  • 박주훈;이병택;장성주;송호준;김영만;문찬기
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.151-151
    • /
    • 2003
  • 열화학기상증착법(Thermal-CVD)을 이용하여 SOI(snilicon-on-insulator)기판과 실리콘기판 상에 단결정 3C-SiC 이종박막을 동시에 성장하고, 그 특성을 비교 분석하였다. 결정성 평가로는 X-선 회절(XRD)분석과 Raman 산란 분광분석, 그리고 투과전자현미경을 이용하였고, 잔류 웅력 비교 분석으로는 laser scanning 방법 과 Raman 산란 분광분석의 3C-SiC LO peak의 위치변화, 그리고 X-선 회절분석의 3C-SiC(004) peak의 위치변화를 이용하였다. 그 결과 SOI 기판과 실리콘 기판상에 고품위의 단결정 3C-SiC 박막이 성장됨을 확인하였고, SOI 기판을 사용한 경우 실리콘 기판에 비해 성장된 3C-SiC 이종박막의 잔류 응력이 실제로 감소됨을 확인하였다.

  • PDF

The Study of Two-dimensional Chemical Distribution about Soil using Laser Spectroscopy (레이저 분광법을 활용한 토양 2차원 화학적 분포도 검출 연구)

  • Yang, Jun-Ho;Yoh, Jai-Ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.6
    • /
    • pp.523-530
    • /
    • 2017
  • Laser-Induced Breakdown Spectroscopy (LIBS) which a plasma is irradiated at a specific wavelength depending on the material when a high-energy laser is irradiated, and a Raman spectroscopy which measures rotation and vibration in molecules as light-scattering phenomenon occurs, are attracting attention as a space exploration technology because of the advantages of high accuracy and real-time analysis, and the ability to perform long-range detection. In this study, the tendency of the laser spectrum according to the change of the soil component was analyzed by laser spectroscopy and the two - dimensional chemical distribution was conducted based on the trend of laser spectrum. We have also established the environment of Mars (4-7 torr) and lunar atmosphere (<1 torr) in experimental setup, to prove that it is possible to measure by difference of soil chemical composition using LIBS and Raman spectroscopy even in artificial space environment.

Identification of High Pressure-High Temperature Treated Gem Diamonds using a Micro-Raman Spectroscopy (고압고온 처리된 보석용 다이아몬드의 마이크로라만 분석에 의한 감별 연구)

  • Song, Oh-Sung;Kim, Jong-Ryul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.817-822
    • /
    • 2006
  • Diamonds have been widely employed as polishing media for precise machining and noble substrates for microelectronics. The recent development of the split sphere press has led to the enhancement of low quality natural diamonds. Synthesized and treated diamonds are sometimes traded deceptively as high quality natural diamonds because it is hard to distinguish among these diamonds with conventional gemological characterization method. Therefore, we need to develop a new identification method that is cheap, fast, and non-destructive. We proposed using a new method of micro-Raman spectroscopy for checking the local HPHT residual stress to distinguish these diamonds from natural ones. We observe unique ~10f compressive and tensile strains at Type I and Type II diamonds after HPHT treatment. Our result implies that our proposed methods may be appropriate fur identification of the treated diamonds with appropriate reference samples.

  • PDF

A Study on the Characteristics of High Energy Nitrogen ion Implanted CdS Thin Films (고에너지 질소 이온 주입된 CdS 박막 특성에 관한 연구)

  • 이재형;홍석주;양계준
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.712-718
    • /
    • 2003
  • The effects of nitrogen ion implantation on vacuum evaporated cadmium sulphide (CdS) thin films were investigated by X-ray diffraction, optical transmittance spectra, and Raman scattering studies. The as-deposited CdS films have a hexagonal structure with preferential (0 0 2) orientation. Formation of Cd metallic clusters was observed in ion implanted films from the XRD patterns. The band gap of N+ implanted films decreased, whereas the optical absorption coefficient values increased with the increase of implantation dose. The Raman peak position appeared at 299 cm-1 and the FWHM increased with the ion dose. A decrease in the area of Raman peak of CdS Al(LO) mode is seen on implantation.