• 제목/요약/키워드: Railroad Passenger Cabin

검색결과 17건 처리시간 0.043초

철도차량 냉방 및 난방장치의 환경성능 시험방안 연구 (Study on the environmental performance test of cooling and heating equipments' of passenger cabin)

  • 조영민;이준석;박덕신;권순박;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.223-228
    • /
    • 2009
  • Cooling and heating equipments of railroad passenger cabin is one of the most important part in keeping the good thermal comfort of the passengers. The bad performance of these equipments usually results in the comfort of the passengers. However, there is no testing method for cooling and heating equipments during manufacturing the passenger car, and calculation method is frequently used. Many railroad operators spend a lot of money for the maintenance. In this study, a new environmental performance test for railroad passenger cabin was suggested. The temperature of the chamber will be changed from $-40^{\circ}C$ to $60^{\circ}C$. The performance test of cooling and heating equipment in controlling the passenger cabin temperature was carried out under various temperature condition. The testing method to investigate the effect of artificial sunlight irradiation on the passenger cabin temperature was also suggested.

  • PDF

철도차량에서의 공기질 현황 및 PM10 오염원 분석 (Air Quality and PM10 Source Analysis on the Railway Vehicles)

  • 박덕신;김동술;조영민;권순박;박은영
    • 한국대기환경학회지
    • /
    • 제23권3호
    • /
    • pp.311-321
    • /
    • 2007
  • Nowadays, concerns have much more growing regarding indoor air quality (IAQ) on the public transportation including railway vehicles. Last year Korea Ministry of Environment (ME) set new guideline for public transportation. In this study several factors were analyzed which may affect comfortableness of railway passenger cabin, and we monitored IAQ parameters (PM10, CO, $CO_2$, VOCs, temperature and humidity) to investigate the present pollution in passenger cabin. In general, the railway air quality was satisfactory. The PM10 and $CO_2$ level on all passenger cabin were below the new guideline level 1 for PM10 $(200{\mu}g/m^3)\;and\;CO_2(2,000ppm)$. Clustering method was carried out to classify the air polluting pattern of the cabin. As a result, the pollutants could be classified to 4 clusters and the origin of pollution is soil, diesel exhaust gas, abrasion of rail and plume.

철도차량용 공기청정시스템 개발 (Development of Amenity-oriented Air Cleaning System for Railroad Passenger Cabin)

  • 박덕신;조영민;권순박;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1288-1292
    • /
    • 2007
  • Because the indoor spaces of the passenger cabin is generally airtight to secure the safety of passengers and enhance the efficiency of the cabin air conditioning performances, the contamination pattern of them are largely similar to that of general indoor spaces. Therefore, continuous supply of outdoor air is required to keep the amenity of indoor space. Heating, ventilation, and air-conditioning (HVAC) system is composed of air cleaning filter, heater and air conditioned, blower and ducts. To achieve the clean indoor environment, an integrated control of each HVAC equipment are required. In this study, we developed the air cleaning system to enhance the amenity of the railroad passenger cabin.

  • PDF

객차용 청정시스템 개발 (Development of Amenity-Oriented Air Cleaning System for Railroad Passenger Cabin)

  • 박덕신;조영민;권순박;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1234-1239
    • /
    • 2006
  • Because the indoors spaces of the passenger cabin is generally airtight to secure the safety of passengers and enhance the efficiency of the cabin air conditioning performances, the contamination pattern of them are largely similar to that of general indoor spaces. Therefore, continuous supply of outdoor air is required to keep the amenity of indoor space. Heating, ventilation, and air-conditioning (HVAC) system is composed of air cleaning filter, heater and air conditioned, blower and ducts. To achieve the clean indoor environment, an integrated control of each HVAC equipment are required. In this study, we developed the air cleaning system to enhance the amenity of the railroad passenger cabin.

  • PDF

이온교환한 제올라이트를 이용한 객실용 이산화탄소 저감방안 연구 (Study on the Removal of Carbon Dioxide in Passenger Cabin using Ion-Exchanged Zeolites)

  • 조영민;최진식;권순박;박덕신;이지윤;김희만
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.568-573
    • /
    • 2011
  • Carbon dioxide concentration of railroad passenger cabin is obliged to be kept lower than guideline values of 'Indoor air quality guideline for public transportations', but actual carbon dioxide concentration frequently exceeds this guideline value. Ventilation is most desirable to lower carbon dioxide concentration but there are some cases when the ventilation is not applicable. In this study, carbon dioxide concentration control method using adsorbents was presented. The cation of zeolites were exchanged with various kinds of cations, and the carbon dioxide adsorption performance of the zeolites were studied. The various kinds of cations, solvents, and zeolites were introduced, and it was found that some cation-exchanged zeolites showed good carbon dioxide adsorption performances. It is expected that the obtained results will be used to lower carbon dioxide concentration of railroad passenger cabin.

  • PDF

$Al_2O_3$ 흡착제를 이용한 객실용 이산화탄소 흡착연구 (Study on the Adsorption of Carbon Dioxide in Passenger Cabin Using $Al_2O_3$ Adsorbent)

  • 조영민;최진식;이지윤;권순박;박덕신
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.138-141
    • /
    • 2011
  • Carbon dioxide concentration of railroad passenger cabin is obliged to be kept lower than guideline values of 'Indoor air quality guideline for public transportations', but actual carbon dioxide concentration frequently exceeds this guideline value during the morning and evening rush hours. For improving comfortability and satisfaction of passengers, concentration control method using $Al_2O_3$ adsorbents was presented. The adsorbent is made from $Al_2O_3$ and LiOH. $Al_2O_3$ perform as a frame and LiOH as a chemical adsorbent. The adsorbent performance experiment was carried out by measuring concentration change of Carbon dioxide in terms of flow, initial concentration and amount of adsorbent. It is expexted that the obtained results will be used to lower carbon dioxide concentration of railroad passenger cabin.

  • PDF

대중교통수단에서 PM10, PM2.5 및 CO2의 농도 현황과 저감기술 개발에 관한 연구 (Characteristics of PM10, PM2.5 and CO2 Concentration in Public Transportations and Development of Control Technology)

  • 박덕신;권순박;조영민;장성기;전재식;박은영
    • 한국입자에어로졸학회지
    • /
    • 제6권1호
    • /
    • pp.9-20
    • /
    • 2010
  • This study examined the concentration level of the major air pollutants in public transportation. The study was conducted between February 2009 and March 2008 at Suwon-Yeosu line in Korea. $PM_{10}$ concentration level was $100{\mu}g/m^3$ on average. The $PM_{2.5}$ to PM10 ratio in transport is 0.37, which was lower than the results published by other researches. The result also demonstrated that outdoor $PM_{10}$ concentration was about 56~60% level compared to that of the cabin. $CO_2$ concentration level in the cabin was 1,359ppm, which does not exceed 2,000ppm, which is the guideline concentration level according to the Ministry of Environment. $CO_2$ concentration level in the cabin was $CO_2=23.4{\times}N+460.2$, and about 23.4ppm in $CO_2$ concentration level increased every time one passenger was added on. The experiment conducted on the train demonstrated that the average $PM_{10}$ concentration level was $100{\mu}g/m^3$ in case of the reference cabin while average $PM_{10}$ concentration level of the modified vehicle was $68{\mu}g/m^3$. Likewise, effect of the particle reduction device for the reduction of $PM_{10}$ concentration level was approximately 21%. Meanwhile there was almost no difference in the concentration level between reference and modified cabin in case of $PM_{2.5}$. Using zeolite as an adsorbent was made to reduce the $CO_2$ concentration level in the cabin. Number of passengers was factored in, to calculate the effect of the adsorption device, which demonstrated that about 36% of $CO_2$ concentration level was reduced in the modified cabin effect of the $CO_2$ reduction device. This research analyzed the current status concerning the quality of air in the public transportation and technologies were developed that reduces major air pollutants.

난방기 출력에 따른 철도차량 객실 내부 온도 분포 분석 (Study on the Temperature Distribution of Cabin under Various Car Heating Modes)

  • 조영민;윤영관;박덕신;김태욱;권순박;정우성;김희만
    • 한국철도학회논문집
    • /
    • 제15권6호
    • /
    • pp.558-565
    • /
    • 2012
  • 최근 기후변화에 따른 이상 기상현상이 증가하고 있는데, 특히 동절기의 혹한은 승객의 열적 쾌적성을 크게 저하할 우려가 있다. 이에 본 연구에서는 철도차량 실대형 환경챔버를 이용하여 저온 조건에서 철도차량의 난방장치 가동시 객실 내부의 온도변화 및 분포를 알아보았다. 실험결과 난방시스템 가동 직후에는 객실 내부온도가 급격하게 증가하였으나, 일정 시간 경과 후에는 더 이상 증가하지 않았으며, 객실의 위쪽이 아래쪽보다 온도가 더 높게 나타났다. 이러한 결과들을 통해 승객의 온열 쾌적감 저하를 최소화할 수 있는 방안을 제시하고자 하였다.

터널을 통과하는 열차의 객실 내 압력 변동 해석 (NUMERICAL SIMULATION OF PRESSURE CHANGE INSIDE CABIN OF A TRAIN PASSING THROUGH A TUNNEL)

  • 권혁빈;윤수환;남성원
    • 한국전산유체공학회지
    • /
    • 제17권1호
    • /
    • pp.23-28
    • /
    • 2012
  • The pressure transient inside the passenger cabin of high-speed train has been simulated using computational fluid dynamics(CFD) based on the axi-symmetric Navier-Stokes equation. The pressure change inside a train have been calculated using first order difference approximation based on a linear equation between the pressure change ratio inside a train and the pressure difference of inside and outside of the train. The numerical results have been assessed for the KTX train passing through a 9km long tunnel of Wonju-Kangneung line at the speed of 250km/h assuming that the train is satisfying the train specification for airtightness required by the regulation.