• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.042 seconds

An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode (MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계)

  • Oh, Jong-Kap
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.315-321
    • /
    • 2011
  • The goal of this study is to reduce patient exposure dose by providing image quality and radiation dose according to inspection methods. Volume Computed Tomography Dose Index(CTDIvol) and Dose Length Product(DLP) of prospective and retrospective ECG gating snapshot segment of Coronary CT angiography(CTA) were measured each snapshot segment methods. CT number, noise, uniformity, and resolution were also measured using phantom under the same condition of coronary CTA. The results showed that CT number, noise, uniformity and resolution are similar to each other. In terms of CTDIvol and DLP, however, measurement dose of prospective ECG gating snapshot segment was lower than the retrospective case by 37.5% and 40.3%. Therefore, it is highly recommended that in the coronary CTA, prospective ECG gating scan mode should be chosen to reduce patient dose.

Normal Lung Ventilation/Perfusion Scintigraphy in Miniature Pigs (미니돼지에서 정상 폐 환기/관류 신티그라피)

  • Kim, Se-Eun;Han, Ho-Jae;Shim, Kyung-Mi
    • Journal of Life Science
    • /
    • v.20 no.11
    • /
    • pp.1725-1728
    • /
    • 2010
  • Miniature pigs are widely used in experiments related to pulmonary disease because of their similarities with humans. However, there are not enough data about normal lung function in miniature pigs. Thus, in this study, we investigated normal lung function in miniature pigs with lung ventilation/perfusion scintigraphy and evaluated the availability of this method. Three male miniature pigs weighing 30-35 kg were used. After general anesthesia, ventilation scintigraphy was performed with 100 MBq of $^{99m}Tc$-pertechnetate (${O_4}^-$), after which perfusion scintigraphy was performed with intravenous injection of $^{99m}Tc$-macro aggregated albumin (MAA). The functional contribution of the right lung was about 55%, and left lung was about 45%, similar to humans. Lung ventilation/perfusion scintigraphy was very useful in evaluating the normal lung function of miniature pigs because it was a non-invasive procedure (no tissue damage was involved), took a short time and was easy to perform. In conclusion, miniature pigs are similar to humans in functional contributions of the lung, and this method will be helpful in future pulmonary disease studies involving miniature pigs.

Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography (디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건)

  • Lee, Won-Jeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.

Deep learning convolutional neural network algorithms for the early detection and diagnosis of dental caries on periapical radiographs: A systematic review

  • Musri, Nabilla;Christie, Brenda;Ichwan, Solachuddin Jauhari Arief;Cahyanto, Arief
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.237-242
    • /
    • 2021
  • Purpose: The aim of this study was to analyse and review deep learning convolutional neural networks for detecting and diagnosing early-stage dental caries on periapical radiographs. Materials and Methods: In order to conduct this review, the Preferred Reporting Items for Systematic Reviews and Meta-Analyses(PRISMA) guidelines were followed. Studies published from 2015 to 2021 under the keywords(deep convolutional neural network) AND (caries), (deep learning caries) AND (convolutional neural network) AND (caries) were systematically reviewed. Results: When dental caries is improperly diagnosed, the lesion may eventually invade the enamel, dentin, and pulp tissue, leading to loss of tooth function. Rapid and precise detection and diagnosis are vital for implementing appropriate prevention and treatment of dental caries. Radiography and intraoral images are considered to play a vital role in detecting dental caries; nevertheless, studies have shown that 20% of suspicious areas are mistakenly diagnosed as dental caries using this technique; hence, diagnosis via radiography alone without an objective assessment is inaccurate. Identifying caries with a deep convolutional neural network-based detector enables the operator to distinguish changes in the location and morphological features of dental caries lesions. Deep learning algorithms have broader and more profound layers and are continually being developed, remarkably enhancing their precision in detecting and segmenting objects. Conclusion: Clinical applications of deep learning convolutional neural networks in the dental field have shown significant accuracy in detecting and diagnosing dental caries, and these models hold promise in supporting dental practitioners to improve patient outcomes.

Prevalence and extension of the anterior loop of the mental nerve in different populations and CBCT imaging settings: A systematic review and meta-analysis

  • Hadilou, Mahdi;Gholami, Leila;Ghojazadeh, Morteza;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.141-153
    • /
    • 2022
  • Purpose: This study aimed to identify the prevalence and extension of the anterior loop (AL) of the mental nerve in different populations and according to different cone-beam computed tomography (CBCT) imaging settings. Materials and Methods: Medline/PubMed, Embase, Scopus, Web of Science, and ProQuest were searched. The main inclusion criterion was ALs evaluated in CBCT images. The quality of studies was assessed with the Joanna Briggs Institute risk of bias checklist. Subgroup analyses were conducted for sex, side, continent, voxel size, field of view, and type of CBCT-reconstruction images with a random-effects model. Results: Sixty-three studies with 13,743 participants (27,075 hemimandibles) were included. An AL was found in 40.6% (95% CI: 32.8%-48.9%, P<0.05) of participants and 36.0% (95% CI: 27.5%-45.5%, P<0.05) of hemimandibles, in 34.9% (95% CI: 25.1%-46.2%, P<0.05) of males and 34.5% (95% CI: 23.5%-47.4%, P<0.05) of females. The average length of ALs was 2.39 mm (95% CI: 2.07-2.70 mm, P<0.05). Their extension was 2.13 mm (95% CI: 1.54-2.73 mm, P<0.05) in males and 1.85 mm (95% CI: 1.35-2.36 mm, P<0.05) in females. Significant differences were observed regarding the prevalence and length of ALs among continents and for its measured length on different CBCT-reconstruction images, but not between other subgroups. Conclusion: AL was a relatively common finding. The voxel size and fields of view of CBCT devices were adequate for assessing AL; however, a 2-mm safety margin from anatomical structures(such as the AL) could be recommended to be considered when using CBCT imaging.

Brain Regions Associated With Anhedonia in Healthy Adults : a PET Correlation Study (정상 성인에서 양전자방출단층촬영을 통해 관찰한 무쾌감증 관련 뇌 영역)

  • Jung, Young-Chul;Seok, Jeong-Ho;Chun, Ji-Won;Park, Hae-Jeong;Lee, Jong-Doo;Kim, Jae-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.438-444
    • /
    • 2005
  • Purpose: Anhedonia has been proposed to be the result of a basic neurophysiologic dysfunction and a vulnerability marker that precede and contribute to the liability of developing schizophrenia. We hypothesized that anhedonia, as a construct reflecting the decreased capacity to experience pleasure, should be associated with decreased positive hedonic affect trait. This study examined the relationship between anhedonia and positive hedonic affect trait and searched for the brain legions which correlate with anhedonia in normal subjects. Materials and Methods: Using $^{18}F$-FDG PET scan, we investigated the brain activity of twenty one subjects during resting state. Questionnaires were administrated after the scan in order to assess the self-rated individual differences in physical/social anhedonia and positive/negative affect traits. Results: Negative correlation between physical anhedonia score and positive affect trait score was significant (Pearson coefficient =-0.440, p<0.05). The subjects physical and social anhedonia scores showed positive correlation with metabolic rates in the cerebellum and negative correlation with metabolic rates in the inferior temporal gyrus and middie frontal gyrus. In addition, the positive affect trait score positively correlated with various areas, most prominent with the inferior temporal gyrus. Conclusion: These results suggest that neural substrates, such as the inferior temporal gyrus and prefrontal-cerebellar circuit, which dysfunction has been proposed to be involved with the cognitive deficits of schizophrenia, may also play a significant role in the liability of affective deficits like anhedonia.

Effect of Noise on Density Differences of Tissue in Computed Tomography (컴퓨터 단층촬영의 조직간 밀도차이에 대한 노이즈 영향)

  • Yang, Won Seok;Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.403-407
    • /
    • 2018
  • Currently, the highest cancer death rate in Korea is lung cancer, which is a typical cancer that is difficult to detect early. Low-dose chest CT is being used for early detection, which has a greater lung cancer diagnosis rate of about three times than regular chest x-ray images. However, low-dose chest CT not only significantly reduces image resolution but also has a weak signal and is sensitive to noise. Also, air filled lungs are low-density organs and the presence of noise can significantly affect early diagnosis of cancer. This study used Visual C++ to set a circle inside a large circle with a density of 2.0, with a density of 1.0, which is the density of water, in which five small circle of mathematics have different densities. Gaussian noise was generated by 1%, 2%, 3%, and 4% respectively to determine the effect of noise on the mean value, the standard deviation value, and the relative noise ratio(SNR). In areas where the density difference between the large and small circles was greatest in the event of 1 % noise, the SNR in the area with the greatest variation in noise was 4.669, and in areas with the lowest density difference, the SNR was 1.183. In addition, the SNR values can be seen to be high if the same results are obtained for both positive and negative densities. Quality was also clearly visible when the density difference was large, and if the noise level was increased, the SNR was reduced to significantly affect the noise. Low-density organs or organs in areas of similar density to cancers, will have significant noise effects, and the effects of density differences on the probability of noise will affect diagnosis.

A Study on the Effective Half-life after the High Dose Radioactive Iodine (131I) Therapy for Thyroid Cancer Patients (갑상선암 환자에서 고용량 방사성요오드 치료 후 유효반감기에 대한 연구)

  • Kim, Seongcheol;Gwon, DaYeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.597-603
    • /
    • 2017
  • High-dose $^{131}I$ therapy has been generally carried out to remove remaining thyroid tissue or to cure metastasize lesion of patients who received full thyroidectomy due to differentiated thyroid cancers. In case high-dose $^{131}I$ therapy is carried out for a patient, the patient should be hospitalized being isolated for a certain period in order to restrict the amount of exposure to radiation of people at large from the patient within the limit of a level of radiation. Effective half-life is an important value to calculate how family members are exposed to radiation from a patient or to decide the period of isolation of the patient from the family members. Therefore, in this study we calculated the effective decay constant, effective half-life and period of isolation of high-dose $^{131}I$ therapy patient using NM670 SPECT/CT. As a result of carrying out this study, the effective half-life of high-dose $^{131}I$ therapy patients was derived and the time to reach the discharge level of 1.2 GBq was confirmed. When they were compared with each other in each of curative doses, the effective half-life did not have significant difference, but the time when the level of radiation remaining in the interior of the body to reach the criteria of isolation and discharge showed significant difference and it could be confirmed that the higher the curative dose the longer the period of isolation becomes. When the effective half-lives in each type of preparation were compared with each other, they did not show significant difference. However, When the times to reach the level of radiation that is the criteria of isolation and discharge in each type of preparations, they showed significant difference. The cause of the shortening of the isolation period for rhTSH patients group is decided to be low curative dose. Accordingly, if the current national health insurance (the insurance is applied to using of rhTSH in 3.7 GBq or lower) is maintained, while discerning them in each of types of preparation, we would be able to discharge patients at the time earlier than the current period of isolation (2 nights and 3 days).

Study of Failure Mode and Effect Analysis in Brachytherapy (근접방사선치료에 관한 사고유형과 영향분석 연구)

  • Lee, Soon Sung;Park, Dong Wook;Shin, Dong Oh;Kim, Dong Wook;Kim, Kum Bae;Oh, Yoon-Jin;Kim, Juhye;Kwon, Na Hye;Kim, Kyeong Min;Choi, Sang Hyoun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.627-635
    • /
    • 2017
  • Brachytherapy is generally performed in conjunction with external radiation therapy, and the treatment course is very complicated, which can lead to radiation accidents. In order to solve this problem, we designed the process map by applying the failure mode and effects analysis (FMEA) method to the Brachytherapy and scored the risk priority number (RPN) for each treatment course based on this process map. The process map consisted of five steps, Patient consulting", "Brachytherapy simulation", "CT simulation", "Brachytherapy treatment planning" and "Treatment". In order to calculate the RPN, doctor, medical physicist, dose planners, therapist, and nurse participated in the study and evaluated occurrence, severity, and lack of detectability at each detail step. Overall, the process map is preceded by a patient identification procedure at each treatment stage, which can be mistaken for another patient, and a different treatment plan may be established to cause a radiation accident. As a result of evaluating the RPN for the detailed steps based on the process map, overall "Patient consulting" and "Brachytherapy treatment planning" step were evaluated as high risk. The nurses showed a tendency to be different from each other, and the nurses had a risk of 55 points or more for all the procedures except "Treatment", and the "Brachytherapy simulation" step was the highest with 88.8 points. Since the treatment stage differs somewhat for each medical institution performing radiotherapy, it is thought that the risk management should be performed intensively by preparing the process map for each institution and calculating the risk RPN.

Evaluation of Roadmap Image Quality by Parameter Change in Angiography (혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가)

  • Kong, Chang gi;Song, Jong Nam;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • The purpose of this study is to identify factors affecting picture quality in Roadmap images, which were studied by varying the dilution rate, collimation field and flow rate of contrast medium. For a quantitative evaluation of the quality of the picture, a 3mm vessel model Water Phantom was self-produced using acrylic, a roadmap image was acquired with a self-produced vascular model Water Phantom, and the SNR(Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were analyzed. CM:N/S In the study on the change of dilution rate, CM:N/S dilution rate changed to (100%~10%:100%), and the measurement of the roadmap image taken using the vascular model Water Phantom showed that the measurement value of SNR gradually decreased as the N/S dilution rate was increased, and the measurement of CNR was gradually reduced. It was confirmed that the higher the dilution rate of CM:N/S, the lower the SNR and CNR, and also significant image can be obtained at the dilution rate of CM:N/S (100%~70:30%). The study showed the value of SNR and CNR in Roadmap image was increased as the Collimation Field was narrowed to the center of the vascular phantom; the Collimation Field was narrowed to the center of the vessel model by 2cm intervals to 0cm through 12cm. To verify the relationship with Roadmap image and Flow Rate, volume of the autoinjector was kept constant at 15 and the flow rate was gradually increased 1, 2, 3, 4, 5, 6, 7, 8, 9, 10. The value of SNR and CNR of images taken by using water Phantom gradually decreased as the Flow Rate increased, but at Flow Rate 9 and 10, the SNR and CNR value was increase. It was not possible to confirm the relationship with SNR and CNR by ROI mean value and Background mean value. It is considered that further study is needed to evaluate the correlation about Roadmap image and Flow Rate. In conclusion, as the dilution rate of N/S in contrast medium was increased, the value of SNR and CNR was decreased. The narrower the Collimation Field, the higher image quality by increasing value of SNR and CNR. However, it is not confirmed the relationship Roadmap image and Flow Rate. It is considered that appropriate contrast medium concentration to minimize the effects of kidney and proper Collimation Field to improve contrast of image and reduce exposure X-ray during procedure is needed.