• 제목/요약/키워드: Radiological Protection

검색결과 433건 처리시간 0.024초

STUDY ON ENTRANCE SKIN DOSE AT PANORAMIC RADIOGRAPHY IN INCHEON, KOREA

  • Choi, Jung-Hyun;Kim, Sung-Chul;Han, Dong Kyoon
    • Journal of Radiation Protection and Research
    • /
    • 제39권4호
    • /
    • pp.182-186
    • /
    • 2014
  • Recently, the use of panoramic radiography has shown a constant increase, and significant research is underway. However, radiation exposure attracts less attention in dental radiography than in other types of radiography. We used an OSLD for measurement of the entrance skin dose in eyeballs and the thyroid region, both of which are not covered by examinations but are included in radiographical regions and are sensitive to radiation, as well as orally in Incheon and reported the results. The entrance skin dose was 0.0282 mSv on average for the oral region, and 0.0259 mSv on average for the eyeball, and 0.0261mSv on average, for thyroid gland. While there is no proper shielding method for the eyeball, a thyroid protector is not used by most hospitals and most hospitals are equipped with an apron and a thyroid protector separately; thus, it is necessary to use an integration of an apron and a thyroid protector and medical device manufacturers need to develop a method for controlling the length of the slit in the slit-type area of radiation occurrence in order to reduce unnecessary exposure.

유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구 (A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter)

  • 노성진;김효진;김현;정동혁;손태건;김정기;양광모;남상희;강영록
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.202-210
    • /
    • 2015
  • 저선량 조사는 낮은 선량을 지속적으로 장기간 조사시키기 때문에 조사되는 마우스들에 대한 선량분포를 정확히 알고 있어야만 한다. 본 연구는 저선량 방사선에 대한 생물학적 영향평가를 위하여 동남권원자력의학원 연구센터에 설치된 $^{137}Cs$ 조사장치에 대하여 마우스조사 실험 시 마우스에 원하고자 하는 선량을 전달하기 위한 방법에 대하여 연구를 수행하였다. 마우스에 원하고자 하는 정확한 선량을 전달하기 위하여 선원에 대하여 동일한 위치에 마우스 케이지 45개를 설치할 수 있는 아파트를 자체 개발하였으며, 개발된 마우스 아파트 시스템에 대한 선량평가를 하기 위하여 유리선량계(glass dosimeter)를 실험용 마우스 머리와 배에 삽입한 후 기존 조사 시스템과 자체 개발한 마우스 아파트 시스템에 대해 비교 선량평가를 수행하였다. 기존시스템의 조사방식에서 최대 42%의 선량차이를 보였으며 개발한 마우스 아파트 시스템은 6% 이내의 선량차이를 보였다. 본 연구를 통해 개발된 마우스 아파트를 활용한 저선량 방사선에 대한 생물학적 영향평가 연구는 전달하고자 하는 선량을 보다 정확하게 제공할 수 있으며, 생물학적 분석결과에 신뢰성을 확보할 수 있다.

경수로형 조사후핵연료의 수송중 사고결과 평가 (An Radiological Assessment Resulting from Accident during Transportation of Irradiated PWR Fuel)

  • 윤여창;하정우
    • Journal of Radiation Protection and Research
    • /
    • 제13권2호
    • /
    • pp.88-94
    • /
    • 1988
  • 조사된 경수로 핵연료의 도로 수송시, 방사선 영향을 INTERTRAN 코드로 평가하였다. 계산된 결과는 인구밀도로 구분한 각 지역의 소집단과 작업자에 따라 집단 선량당량으로 구하였다. 정상 수송과 수송 사고에 대한 평가 결과, 각 집단의 선량은 매우 낮은 수준을 나타내었다. 계산 프로그램은 다양한 입력 자료에 의하여 정량화 되므로 앞으로 입력 자료의 확보를 위한 연구가 필요하다.

  • PDF

선량평가 및 Display시스템 (A Rapid Dose Assessment and Display System Applicable to PWR Accident)

  • 문광남;육종철
    • Journal of Radiation Protection and Research
    • /
    • 제13권2호
    • /
    • pp.67-77
    • /
    • 1988
  • 원자력발전소의 비상사태 발생시 효과적인 비상대책 수립을 위하여 인근 주민에 대한 신속한 피폭선량 평가 시스템의 개발이 강조되고 있다. 여기서 개발한 시스템은 다양한 원전의 사고에 대해 인근 주민에 대한 방사선 영향의 신속한 평가 모델로서 마이크로 컴퓨터에 기초한 프로그램이며, 문답형의 메뉴방식의 사용자 입력구조를 가지고 있고 수행 결과의 출력은 표 또는 그래픽 형식의 구조를 가지고 있어서 신속한 피폭선량평가 수행뿐만 아니라 신속한 결과 판독이 가능하여 비상대책 활동을 위한 결정에 도움을 준다.

  • PDF

먹는 샘물의 방사성물질 측정 및 유해성 평가 (Evaluation of Radioactive Substance and Measurement of Harmfulness in Drinking Water)

  • 조정원;이상복;남조현;노은정;백현우;이예진;이준세;최지원;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.247-252
    • /
    • 2021
  • As the number of single-person households increases, the consumption of bottled water is increasing. In addition, as the public's interest in radioactivity increases, interest in the field of living radioactivity is also increasing. Since drinking water is an essential element in our daily life, it must be safe from radioactivity. In this study, gamma radiation of drinking spring water was measured and internal exposure dose evaluation was performed to determine its harmfulness. K-40 and uranium-based radioactivity analysis was performed through a high-purity germanium detector, and as a result, drinking water was detected somewhat higher than that of mixing water. Since there is no regulation on the natural radioactivity concentration in Korea, it was compared with the U.S. Environmental Protection Agency Drinking Water Regulations and World Health Organization standard. As a result, there were some items that exceeded standards. Internal exposure was evaluated according to the effective dose formula of ICRP 119. As the result was derived that a maximum of 1.17 mSv per year could be received. This result means that the dose limit for the general public may be exceeded, and it was judged that it is necessary to set an appropriate standard value and present a recommendation value through continuous monitoring in the future.

ICRP신권고에 따른 직무피폭에서의 선량제약치 국내 적용 방안 연구 (A Study on the Implementation of Dose Constraints in Occupational Dose According to ICRP 103 Recommendations in Korea)

  • 김용민;조건우
    • Journal of Radiation Protection and Research
    • /
    • 제36권3호
    • /
    • pp.127-133
    • /
    • 2011
  • 국제방사선방호위원회에서는 2007년에 방사선방호에 관한 권고(ICRP 103)를 개정하였다. 이에 따라 국제원자력기구에서도 전리방사선 방호에 관한 국제기본안전기준을 개정하고 있으며 국내에서도 신권고의 내용을 국내요건에 반영하기 위한 연구가 진행 중이다. 신권고가 기존 권고에서 크게 변화되지 않았지만 방사선산업의 성장으로 인해 작은 변화에도 큰 영향을 가져올 수 있기 때문에 신권고의 내용을 국내 반영하기 위한 준비가 필요하다. ICRP 103의 주요 특징중 하나는 기존 권고에 비해 방호최적화를 한 단계 더 강조한 것이다. 이를 위해 계획피폭상황에서 선량제약치를, 기존 및 비상피폭상황에서 참조준위를 사용할 것을 권고하였다. 선량제약치는 전망적이고 선원중심적 제한값으로서 개인에 대한 방호의 기본 수준을 제공하며, 그 선원에 대한 방사선방호 최적화에 상한 선량 역할을 하게 된다. 이에 따라 국내에서도 원자력 및 방사선이용시설에 대해 선량제약치 운영이 요구될 것이다. 규제기관과의 협력과 더불어 직무피폭에 관한 선량제약치를 사업자가 설정하고 운영함으로써 최적화가 더 강조될 수 있을 것으로 예상된다. 선량제약치가 규제도구가 아닌 방사선방호최적화를 위한 절차로 국내 적용되기 위한 방안을 도출하였다.

Preliminary Radiological Considerations for X-ray Free Electron Laser Project at PAL

  • Lee, Hee-Seock;Hong, Suk-Mo;Kim, Min-Ho
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2004년도 추계학술발표회 발표논문집
    • /
    • pp.1190-1191
    • /
    • 2004
  • New $4^{th}$ generation synchrotron facility, XFEL, is almost similar to previous $3^{rd}$ generation synchrotron facility in the view of radiological aspects and most important positions are a dump and synchrotron radiation beam line. In this paper, tile radiation protection solutions for them and undulator are suggested and discussed.

  • PDF

금전계수 도출을 위한 경제학적 방법론 연구 (A Study on Economic Methodology for Deriving Money Coefficients)

  • 백민희
    • 방사선산업학회지
    • /
    • 제17권1호
    • /
    • pp.111-118
    • /
    • 2023
  • The International Commission on Radiological Protection (ICRP) 103 recommends a cost-benefit analysis method as an auxiliary tool for scientific and rational decision-making for the principle of optimization of radiological protection. In order to conduct a cost-benefit analysis, the safety improvement of nuclear power by regulation must be measured and converted into monetary terms. The improvement of nuclear safety can be measured by reducing the radiation exposure dose of the people, and it is necessary to determine the coefficient to convert the radiation exposure dose into money. The monetary coefficient is calculated as the product of the statistical life value (VSL) and the nominal risk coefficient. In order to derive the monetary coefficient, the willingness to pay (WTP) can be estimated using the contingent valuation method (CVM), which quantifies the value of non-market goods by converting them into monetary units. WTP can be estimated based on the random utility model, which is the basic model for bivariate selection type conditional value measurement data. Statistical life value can be calculated using the estimated WTP and reduction in early mortality, and a monetary coefficient can be derived.