According to the increase in the use of radiotherapy to cancer patients, many approaches have been tried to develop new agents for the protection of surrounding normal tissues. However, it is still few applied in the clinic as a radioprotector. We aim to find a representative parameter for radioprotection to easily predict the activity of in vivo experiment from the results of in vitro screening. The polysaccharide extracted from Panax ginseng was used in this study because the immunostimulator has been regarded as one of the radioprotective agent category and was already reported having a promising radioprotective activity through the increase of hematopoietic cells and the production of several cytokines. Mitogenic activity, AK cells activity and nitric oxide production were monitored for the in vitro immunological assay, and endogenous colony-forming unit (e-CFU) was measured as in vivo radioprotective parameter. The immunological activity was increased by the galactose contents of ginseng polysaccharide dependently. The result of this study suggests that mitogenic activity of splenocytes demonstrated a good correlation with in vivo radioprotective effect, and may be used as a representative parameter to screen the candidates for radioprotector.
The internal contamination screening method using gross beta measurement was performed for radioisotope workers. 24 h and spot urine samples from workers of medical isotope production facilities were collected and measured. Most of the results were similar with the background level of gross beta activity except for a specific worker. Gross beta activity was slightly increased in several hours after finishing work. And the environmental factor of production facilities causing internal contamination were estimated based on screening results. The additional detailed internal dose assessment must be followed after the screening for protection of workers. Moreover, a procedure was established to apply a simple internal contamination assessment for radiation workers.
Ha, Wi-Ho;Park, Seyoung;Yoo, Jaeryong;Yoon, Seokwon;Lee, Seung-Sook;Kim, Jungho;Kim, Jong Kyoung
Journal of Radiation Protection and Research
/
v.38
no.3
/
pp.143-148
/
2013
Operational nuclear facilities such as nuclear power plants and particle accelerators show various neutron spectra according to the type of facilities and specific position. Necessities of neutron dose management and neutron monitoring for radiation protection of radiation workers in such a kind of facilities have continuously increased in recent years. Bonner sphere spectrometers are widely used for measurement of neutron spectra. Data on response function of neutron detector, default neutron spectra and count rates of Bonner sphere spectrometer are required to obtain unfolded neutron spectra in specific workplaces. In this study, we carried out measurement of neutron spectra produced in MC50 cyclotron using Bonner sphere spectrometer with LiI scintillation detector. Additionally, we estimated quantitative data on neutron flux, mean neutron energy and ambient dose equivalent rate according to the incident proton energies and positions in MC50 cyclotron.
Interventional radiologists are not aware of the potential injury from procedures. The purpose of this study are to evaluate radiation exposure of interventional radiologist from intervention procedures and to develop guideline of the simple methods for decreasing their radiation exposure from intervention procedure. In this study, Dosimeters were used to monitor operator doses of radiation exposure in a broad range of procedures from 20 interventional radiologist during the periods of 3 months. And, we searched protection methods of each interventional radiologist. During TACE procedure, there was using 0.5 mmPb radiation protector decreased average 89.5 % of radiation exposure. Thicker radiation protector provide decreasing radiation exposure. And radiation exposure dose decreased average 47.7 % by using pulse fluoroscopic mode. Therefore, interventional radiologist should wear protective aprons, use active shielding, monitor their doses, and know how to poisoning themselves during the procedure and operate correct of the machines for minimum dose.
Kim, Kyotae;Kang, Sangsik;Noh, Sicheul;Jung, Bongjae;Cho, Changhoon;Heo, Yeji;Park, Jikoon
Journal of the Korean Society of Radiology
/
v.6
no.6
/
pp.483-487
/
2012
In 1895, the discovered X-ray is used for not only in this field of medicine wide but also field. The detection of radiation after, people realized the risk of the radiation exposured recommended the principle about the protection of radiation by the part of the effort for lowering the radiation exposure. In this recommendation, all unnecessary radiation exposure have to be prevented by All doses include the protection of radiation, general idea of applicable two kinds of that it has to low maintain. Presently, in the General X-ray room of the clinical, the lead (Pb) was used for the shielding, However, because it had the problem of the lead poisoning which is fatal in the human body, the alternatives was showed. and Among them, the material that it is the tungsten was presented. in this research, the absorbed spectrum according to the thickness in the continuous X-ray energy of the tungsten which is not harmful to the human body through the Monte Carlo simulation, tried to compare with the absorbed spectrum of the lead (Pb). The tungsten confirmed that simulation presumption than result lead in the whole domain that absorbed probability was higher and it is considered that tungsten shows the absorbed efficiency higher than the lead in particularly, 70 keV ~ 90 keV and the tungsten is more useful to the X-ray energy cover of the high energy diagnostic area.
The purpose of this study is to check the extent to which "instruction of physician or dentist" defined in the Medical Service Technologists, etc. Act is applied in relation to radiography examination procedures for radiological technologists. In addition, it is intended to present basic data on the requirement to revise the Medical Service Technologists, etc. Act in the radiological technologist's duty area and scope of work, The subjects of this study were radiological technologists with license, and the response data were collected after sending the questionnaire link written on the online questionnaire form. The final number of respondents were 1,018, and the response rate was 6.8%. Most of the negative responses were "I have never received 'instruction' for radiologic examination by a physician or dentist, including a radiologist in a medical environment." There were a high perception that "the professionalism in radiation examination on radiological technologists are higher than that of a physician or dentist." They answered that the current continuing education has a great impact on maintaining and continuing professionalism and learning new knowledge in the radiology field. In addition, the radiological technologists provide a very high level of education in areas related to radiography procedure ethics such as patient care, patient safety, and patient privacy protection, as well as specialized fields such as radiation-related examination methods, radiography examination dose, and patient exposure dose. Radiological technologists replied that they were receiving it consistently. In conclusion, in the current medical environment, the 'instruction' of a physician or dentist cannot be seen as being realistically performed. The phrase 'instruction' of a physician or dentist as defined in the Medical Service Technologists, etc. Act is considered inappropriate in respect of the fact that the state recognizes the qualifications of the medical service technologist through a license. It is thought that revision to a new term suitable for the current medical environment is necessary.
Journal of Korea Entertainment Industry Association
/
v.14
no.7
/
pp.571-579
/
2020
This study was attempted to identify the analysis of educational needs and correlation between knowledge and attitude of radiation protection among emergency medical services students for life care to recognize the importance of radiation protection and provide the basic data for developing personalized educational programs for safety management in radiation protection for emergency medical services students. The result showed that the correlation between knowledge about radiation protection and attitude toward it, there was a positive correlation between attitude score and knowledge score regarding the radiation protection (r=.472, p<.000). In participation intention into the education about the radiation protection, 82% of the responders said that they had participation intention. In time when they are to be educated, 2nd graders was the highest at 54.9%, in instructional method, lecture with audiovisual materials was the highest at 59.04%, and in lecturer, radiological technologist was the highest at 77.45%. It could be found from such findings that emergency medical services students' life care of education needs for radiation protection and participation intention were high and concluded that safety management educational program development for radiation protection is required with accurate knowledge about radiation protection and positive attitude and to increase the educational effects, radiological technologist's utilizing the audiovisual materials for instruction is the most effective.
Proceedings of the Korea Institute of Fire Science and Engineering Conference
/
2011.11a
/
pp.413-416
/
2011
대용량 기기의 효율적인 전력 공급을 위해 부스닥트의 수요가 급증하고 있으며, 특히 컴팩트형 부스닥트는 케이블에 비해 무게와 부피가 가볍고 전력 효율도 25% 이상 우수하며, 기술의 핵심은 에폭시분체도료의 절연 특성 향상과 제작공정의 최적화와 안정화이다. 따라서 본 연구에서는 유동침적방식(Fluidized Bed Process)에 대한 최적화와 에폭시 분체도료의 절연설계 및 열화특성에 대해 실험 검토 하였다. 또한 전기화재의 주된 원인인 아크방전특성과 절연파괴 특성에 대한 분석과 더불어 다양한 상용제품들의 특성을 비교하였다.
We aim to evaluate safety of radiation by measuring leakage dose and patient(phantom) incident dose of ZEN-PX II dental portable equipment developed by G company. Measurement for leakage dose of equipment is conducted on the top, at the bottom, on the left, on the right and at the back. Dose measurement incident on the subject with the area dosimeter when using the phantom and measurement the leakage dose of equipment when using the phantom are evaluated. Comparing the right with the highest leakage dose as a 0 cm, 25 cm, 50 cm, 75 cm and 100 cm dose measurement at the measurement height of 100 cm, 64.2 uR was reduced to 47.3 uR in the senser mode 0.32sec. Even in film mode it was measured at 414.4 uR and about 27% lower at 162.6 uR. As the result of this study, when the irradiation time is 2 sec the right side dose is 290.5 uR and sensor mode is 0.32 sec the right side dose is 64.2 uR.
Bone mineral density is a examination to measure the amount of bone in patients with metabolic bone disease. It is a low dose, but may cause unnecessary exposure to the gonads and other organs located in the periphery when examining the lumbar and proximal femurs. Therefore, the purpose of this study was to evaluated the exposure dose for each organ exposed during the bone mineral density through simulation, and analyzed the applicability of the subject to radiation shielding devices using 3D printing materials. As a result, the highest dose was shown at 11.47 uSv in the breast during lumbar examination and 8.98 uSv in the testis during proximal femur examination. Also, the farther away from the examination site, the lower the effect of the scattering-ray. The shielding effect of using 3D printing shielding device showed high results in proportion to the effective atomic number and specific gravity of the printing material. Among the printing materials, ABS + W showed an effect of at least 78.72 to 96.3 9% compared to the existing lead material.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.