• Title/Summary/Keyword: Radiological Effects

Search Result 597, Processing Time 0.027 seconds

Effects of the Role Conflict, Ambiguity, and Job Satisfaction of the Health Professionals to Their Customer Orientation (의료종사자의 역할갈등, 모호성, 직무만족이 고객지향성에 미치는 영향)

  • Kim, Chang Tae;Kang, Su Man;Park, Cheol Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Recently in the health service the globalization and opening their market to foreigners are realized in Korea. So, it becomes necessary for the health service institutes to execute their management to focus on service quality to satisfy their customers. We examined the customer orientation of the individual health professional rather than the market orientation concept based on the health institute. For the market orientation of the health institute should require the individual health professional worked there. The hypotheses for the effect of the role conflict, ambiguity, and job satisfaction of the health professionals to their customer orientation were established based on the literature review and previous researches and tested to the 250 health professionals such as health technician, nurse, radiologist, and management clerk in D hospital located in Busan, in summer 2008. First, the hypothesis 'The role conflict between the individual health professionals might effect to the customer orientation' was rejected. Second, the hypothesis 'The role ambiguity of the individual health professional might effect to the customer orientation' was accepted. Third, the hypothesis 'The satisfaction of the individual health professional might effect to the customer orientation' was rejected. and the multiple regression analysis was taken with the dependent variables as each construct of customer orientation-responsiveness, empathy, tangibility, and reliability, and independent variables as role conflict, role ambiguity, and job satisfaction. With these analysis, we found also the role ambiguity effected to the customer orientation.

Congenital Midgut Malrotation : Radiological Findings (선천성 중장 회전 이상의 방사선학적 소견)

  • An, Jae-Hong;Hwang, Mi-Soo;Park, Bok-Hwan;Koh, Jung-Kon
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.2
    • /
    • pp.393-398
    • /
    • 1997
  • An accurate early diagnosis of congenital midgut malrotation is essential to prevention of catastrophic effects of volvulus. To evaluate the usefulness of radiologic examinations in diagnosing intestinal malrotation, we retrospectively analyzed radiologic findings and operation records of 17 intestinal malrotation patients, who were radiologically diagnosed. The age range of the patients studied were from 1day to 12years. The presenting symptoms were vomiting, vomiting with abdominal pain, abdominal distention, diarrhea and failure to thrive. The viewpoints of this analysis were the location of duodeno-jejunal flexure on barium meal and cecal location on barium enema. Sixteen of 17 patients, who were radiologically diagnosed, were surgically proven, but one patient with annular pancreas was false positive. In the case of 3 surgically proved patients, malrotation was suspected on barium meal prior to the barium enema, but final diagnosis was determined on barium enema examination. We concluded that a barium enema should be performed on all children with suspected malrotation where the initial upper gastro-intestinal study was normal or suspicious on account of the small incidence of false positive and false negative barium meals.

  • PDF

Design and Application of Acrylic Electron Wedge for Improving Dose Inhomogeneities at the Junction of Electron Fields (전자선 조사야 결합부분의 선량분포 개선을 위한 acrylic electron wedge의 제작 및 사용)

  • Kim, Young-Bum;Kwon, Young-Ho;Whang, Woong-Ku;Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.36-42
    • /
    • 1998
  • Treatment of a large diseased area with electron often requires the use of two or more adjoining fields. In such cases, not only electron beam divergence and lateral scattering but also fields overlapping and separation may lead to significant dose inhomogeneities(${\pm}20%$) at the region of junction of fields. In this study, we made Acrylic Electron Wedges to improve dose inhomogeneities(${\pm}5%$) in these junction areas and to apply it to clinical practices. All measurements were made using 6, 9, 12, 16, 20 MeV Electron beams from a linear accelerator for a $10{\times}10\;cm$ field at 100cm of SSD. Adding a 1 mm sheet of acryl gradually from 1 mm to 15 mm acquires central axis depth dose beam profile and isodose curves in water phantom. As a result, for all energies, the practical range was reduced by approximately the same distance according to the acryl insert, e.g. a 1 mm thick acryl insert reduces the practical range by approximately 1 mm. For every mm thickness of acryl inserted, the beam energy was reduced to approximately 0.2 MeV. These effects were almost Independent of beam energy and field size. The use of Acrylic Electron Wedges produced a small increase(less than 3%) in the surface dose and a small increase(less than 1%) in X-ray contamination. For acryl inserts, thickness of 3 mm or greater, the penumbra width increased nearly linear for all energies and isodose curves near the beam edge were nearly parallel with the incident beam direction at the point of penumbra width($35\;mm{\sim}40\;mm$). We decide heel thickness and angle of the wedge at this point. These data provide the information necessary to design Acrylic Electron Wedge which can be used to improve dose uniformity at electron field junctions and it will be effectively applied to clinical practices.

  • PDF

Estimation of Absorbed Dose for Anterior and Posterior Organs with Body Mass Index in Standing Whole Spine Examination (Standing Whole Spine 검사 시 체질량지수 (BMI)에 따른 전방 및 후방장기의 흡수선량 평가)

  • Shim, Ji Na;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.147-151
    • /
    • 2016
  • Automatic exposure control (AEC) is frequently used in many hospitals for Standing Whole Spine examination which is able to control radiation dose with respect to the body type such as body mass index (BMI) and we can measure dose area product (DAP) based on respective patient information. However, few studies have been conducted organ absorbed dose evaluation based on location of patient organ. The purpose of this study was to evaluate the relationships between BMI and organ absorbed dose along with location of patient organ. For that purpose, we calculated absorbed dose with selected 5 patient organ (thyroid, breast, heart, kidney, and pancreas) using a PCXMC simulation tool with measured DAP. According to the results, measured DAP increases with BMI and organ absorbed dose decreases with BMI in anterior organs such as thyroid, breast, and heart. On the other hand, there is no correlation between organ absorbed dose and BMI in posterior organs such as kidney and pancreas. In conclusion, our results demonstrated that the radiation effects are different with respect to BMI and location of patient organ in Standing Whole Spine examination.

Characteristic of Stress According to Student Clinical Training in Department of Radiology (방사선(학)과 학생 임상실습에 따른 스트레스 특성)

  • Baek, Chang-Moo;Chae, Soo-In;Kim, Jeong-Koo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.291-298
    • /
    • 2012
  • Department of radiology implements the hospital-based clinical training to accept medical treatment techniques and to adapt experiences for students. However, it might cause negative effects to training education, leading to doubt about major and pressure about training as lots of students experience clinical treatment and complex stress in unfamiliar environment. Regarding this, pressure element that students can experience and diverse variables of training were compared and analyzed. With students in department of radiology for 6 colleges and universities, from September 15th to October 25th in 2011. The degree of stress for students in training was shown high in the fields of cost(3.06) and trainers(3.02). Value and ideal(2.94), role and experiment(2.93), training environment(2.74) and relationships among trainees(2.64) were followed in the order. Except expense regarding stress from clinical training, but in all factors, women showed higher pressure level than men(P<.05) and in stress range according to BEPSI-K, a meaningful difference was shown in fields of training environment, relationships among trainees and role and experiment(P<.01, P<.001, P<.05). Therefore, It has been confirmed that there is correlation between stress of students and satisfaction for clinical training with each other closely.

An Implementation of Obesity Management System with Individually Adapted Complex Care (개인 맞춤형 통합 치료가 가능한 비만 관리 시스템 개발)

  • Noh, Si-Cheol;Kim, Ju-Young;Kim, Jin-Su;Kang, Sang-Sik;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.83-91
    • /
    • 2012
  • The obesity is a medical condition in which excess body fat has accumulated to the extent. It may have an adverse effect on health, leading to reduced life expectancy and increased health problems such as lifestyle disease, hypertension, and diabetes. Furthermore, it may cause the mental illness such as depression, bipolar disorder, anorexia, hyperphagia, and so on by shrinking psychologically. So, it is regarded as the serious worldwide social problem. Recently, although there are many general obesity care methods with various approaches, these can't be the radical obesity care because of the side effects such as surgery aftereffect, drug addiction, and so on. For these reasons, a methodical approach with a consideration of individual obesity pattern is strongly demanded. In this study, complex obesity care and management system which is overcome the weakness of non-surgical obesity treatment is proposed. And the individually adapted obesity treatment system with the far-infrared therapy module, oxygen therapy module, color therapy module, and microwave therapy module was developed. The complex obesity treatment system which is proposed in this study, could improve the efficiency of treatment by suggesting the various treatment protocols. And proposed system could be the foundation of the high quality obesity treatment system.

A Monte Carlo Study of Dose Enhancement with kilovoltage and megavoltage photons (몬테칼로 기법을 이용한 kV, MV X선에서의 선량증가 효과 비교 평가)

  • Hwang, ChulHwan;Im, In-Chul;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2017
  • Monte Carlo simulations were used to assess dose enhancement effects for 60-, 90-, 120-, and 150-kV X-rays, and for 6- and 15-MV X-rays. The MCNPX code was used for a computer simulation of the ICRU slab phantom, and gold, gadolinium, and iron oxide (Fe2O3) were employed as dose enhancement agents. In consideration of the buildup region of the incident energy, agent concentrations of 5, 10, 15, and 20 mg/g were inserted on the surface of the phantom at a depth of 5 cm. Based on baseline values obtained in the absence of dose enhancement agents, a quantitative analysis was performed by evaluating depth-dependent changes in the absorbed energy and the dose enhancement factor (DEF). A higher concentration of dose enhancement agents led to a greater dose enhancement effect with iron oxide, gadolinium, and gold in descending order. For kilovoltage (kV) X-rays, as the incident energy was decreased and as the energy became closer to the ionization potential of the atoms in the enhancement agent, the dose enhancement effect increased. In the megavoltage (MV) X-ray range, dose enhancement was higher at 6 MV compared with 15 MV. However, the overall dose enhancements were significantly lower compared to the results obtained with kV X-rays.

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.

Transport parameters in a-Se:As films for digital X-ray conversion material using the moving-photocarrier-grating technique (moving-photocarrier-grating 기술을 이용한 디지털 X-선 변환물질 a-Se:As의 수송변수)

  • Park, Chang-Hee;Nam, Sang-Hee;Kim, Jae-Hyung
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.267-272
    • /
    • 2005
  • The effects of As addition in amorphous selenium (a-Se) films for digital X-ray conversion material have been studied using the moving photocarrier grating (MPG) technique. This method utilizes the moving interference pattern generated by the superposition of the two frequency shifted laser beams for the illumination of the sample. This moving intensity grating induces a short circuit current, jsc in a-Se:As film. The transport parameters of the sample are extracted from the grating-velocity dependent short circuit current induced in the sample along the modulation direction. The electron and hole mobility, and recombination lifetime of a-Se films with arsenic (As) additions have been obtained. We have found an increase in hole drift mobility and recombination lifetime, especially when 0.3% As is added into a-Se film, whereas electron mobility decreases with As addition due to the defect density. The transport properties for As doped a-Se films obtained by using MPG technique have been compared with X-ray sensitivity for a-Se:As device. The fabricated a-Se(0.3% As) device film exhibited the highest X-ray sensitivity out of 5 samples.

  • PDF

Influence to the Doppler Images by the Defects of Piezoelectric Elements of the Probe of Medical Ultrasonic Scanners (Focusing on the Impact of an Increase in the Defects of Piezoelectric Elements) (초음파 프로브 소자 결함이 도플러 영상에 미치는 영향 (소자 결함 증가에 따른 영향을 중심으로))

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. This work was implemented that the quality of Doppler images depended on the extent and location of the probe element defected. The probe performance was rated in terms of the number of piezoelectric elements lost and this was studied in the experiment by electrical disconnection to the elements. The results showed that Doppler velocity became rapidly reduced as the defected elements encountered with the element group activated at the Doppler mode, not as the flow velocity. The effect of the probe defect is decreased when the defects occurred at the element group activated for Doppler mode, as was increased the number of the elements. It was observed that the higher the flow velocity of Doppler flow phantom is, the wider the spectrum of Doppler is. And the Doppler velocity soared up and the dispersion of image brightness is increased when the defected elements got out of the elements activated at Doppler mode. The result showed that TADVP(time-average-Doppler-velocity-profile) is decreased with the increase of the probe element defect, especilly in the region of high frequency. It is expected that the research of various defects of probe elements are needed, and this study can be practical tools for probe based ultrasonic QA in the future.