Abstract
Automatic exposure control (AEC) is frequently used in many hospitals for Standing Whole Spine examination which is able to control radiation dose with respect to the body type such as body mass index (BMI) and we can measure dose area product (DAP) based on respective patient information. However, few studies have been conducted organ absorbed dose evaluation based on location of patient organ. The purpose of this study was to evaluate the relationships between BMI and organ absorbed dose along with location of patient organ. For that purpose, we calculated absorbed dose with selected 5 patient organ (thyroid, breast, heart, kidney, and pancreas) using a PCXMC simulation tool with measured DAP. According to the results, measured DAP increases with BMI and organ absorbed dose decreases with BMI in anterior organs such as thyroid, breast, and heart. On the other hand, there is no correlation between organ absorbed dose and BMI in posterior organs such as kidney and pancreas. In conclusion, our results demonstrated that the radiation effects are different with respect to BMI and location of patient organ in Standing Whole Spine examination.
Keywords
Standing whole spine examination; Organ absorbed dose; Body mass index (BMI); Dose area product (DAP); PCXMC;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Y. G. Lee and W. S. Lee, "Subjective Evaluation of Image Quality on Digital Image Processing of Chest CR Image", Journal of the Institute of Electronics Engineers of Korea, vol. 48-IE, no. 1, pp. 51-56, 2011.
2 J. S. Lee, S. J. KO, S. S. Kang, J. H. Kim, D. H. Kim and C. S. Kim, "Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image", The Korea Contents Association, vol. 13, no. 8, pp. 275-283, 2013.
3 G. Ullman, M. Sandborg, D. R. Dance, R. Hunt and G. A. Carlsson, "THE INFLUENCE OF PATIENT THICKNESS AND IMAGING SYSTEM ON PATIENT DOSE AND PHYSICAL IMAGE QUALITY IN DIGITAL CHEST IMAGING", Radiation Protection Dosimetry, vol. 114, no. 1-3, pp. 294-297, 2005.   DOI
4 J. C. Yanch, R. H. Behrman, M. J. Hendricks, and J. H. McCall, "Increased Radiation Dose to Overweight and Obese Patients from Radiographic Examinations", Radiology, vol. 252, no. 1, pp. 128-139, 2009.   DOI
5 J. Ector, O. Dragusin, B. Adriaenssens, W. Huybrechts, R. Willems, H. Ector and H. Heidbuchel, "Obesity is a major determinant of radiation dose in patients undergoing pulmonary vein isolation for atrial fibrillation.", Journal of the American College of Cardiology, vol 50, no. 3, pp. 234-242, 2007.   DOI
6 C. J. Tung, C. J. Lee, H. Y. Tsai, S. F. Tsai, and I. J. Chen, "Body size-dependent patient effective dose for diagnostic radiography.", Radiation Measurements, vol 43, no. 2, pp. 1008-1011, 2008.   DOI
7 T. Fujibuchi, N. Funabashi, M. Hashimoto, H. Kato, M. Kurokawa, H. M. Deloar and T. Sakae, "Estimate of organ radiation absorbed doses in clinical CT using the radiation treatment planning system.", Radiation protection dosimetry, vol 142, no. 2-4, pp. 174-183, 2010.   DOI
8 L. T. Dauer, R. Thornton, D. C. Boylan, B. Holahan, R. Prins, B. Quinn and J. S. Germain, "Organ and effective dose estimates for patients undergoing hepatic arterial embolization for treatment of liver malignancy.", Medical physics, vol. 38, no. 2, pp. 736-742, 2011.   DOI
9 Radiation safety series No. 19, "guideline for dignostic reference level at computed tomography", Ministry of Food and Drug Safety, no. 19, 2009.
10 H. Schlattl, M. Zankl and N. Petoussi-Henss, "Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures.", Physics in medicine and biology, vol. 52, no. 8, pp. 2123-2145, 2007.   DOI
11 R. Protection, "ICRP publication 103." Ann. ICRP, vol. 37 no. 2-4, 2007.
12 H. Kim, M. Park, S. Park, H. Jeong, J. Kim and Y. Kim, "Estimation of absorbed organ doses and effective dose based on body mass index in digital radiography.", Radiation protection dosimetry, vol. 153, no. 1, pp. 92-99. 2013.   DOI