• Title/Summary/Keyword: Radiological

Search Result 7,256, Processing Time 0.028 seconds

Recognition difference and improvement direction of the radiological technologists and patient against medical service in department radiology - In-chon area in the object - (방사선과 보건의료서비스에 대한 방사선사와 환자의 인식차이 및 개선방향 - 인천지역을 중심으로 -)

  • An, Sung-Min;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.93-98
    • /
    • 2006
  • Satisfaction of the patient against the medical service in department of radiology and it evaluated the different recognition of radiological technologist and patient. and investigates it's improvement direction. It sent the reply the above the which is a usual result in question result of the most that, the receipt process it was complicated in the portion which is insufficient,"The receipt process is complicated", "waiting time is long"and "don't radiation protection for patient and guardian". Also these a facts was recognizing patients and radiological technologist all. And the effort of the radiological technologist is necessary with the method which reduces a recognition difference. The periodical medical service satisfaction investigates and must endeavor in reform measure preparation.

  • PDF

Intracerebral Hemorrhage Auto Recognition in Computed Tomography Images (CT 영상에서 뇌출혈의 자동인식)

  • Choi, Seok-Yoon;Kang, Se-Sik;Kim, Chang-Soo;Kim, Jung-Hoon;Kim, Dong-Hyun;Ye, Soo-Young;Ko, Seong-Jin
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.141-148
    • /
    • 2013
  • The CT examination sometimes fail to localize the cerebral hemorrhage part depending on the seriousness and may embarrass the pathologist if he/she is not trained enough for emergencies. Therefore, an assisting role is necessary for examination, automatic and quick detection of the cerebral hemorrhage part, and supply of the quantitative information in emergencies. the computer based automatic detection and recognition system may be of a great service to the bleeding part detection. As a result of this research, we succeeded not only in automatic detection of the cerebral hemorrhage part by grafting threshold value handling, morphological operation, and roundness calculation onto the bleeding part but also in development of the PCA based classifier to screen any wrong choice in the detection candidate group. We think if we apply the new developed system to the cerebral hemorrhage patient in his critical condition, it will be very valuable data to the medical team for operation planning.

In Vitro Genotoxicity Assessment of a Novel Resveratrol Analogue, HS-1793

  • Jeong, Min Ho;Yang, Kwangmo;Lee, Chang Geun;Jeong, Dong Hyeok;Park, You Soo;Choi, Yoo Jin;Kim, Joong Sun;Oh, Su Jung;Jeong, Soo Kyung;Jo, Wol Soon
    • Toxicological Research
    • /
    • v.30 no.3
    • /
    • pp.211-220
    • /
    • 2014
  • Resveratrol has received considerable attention as a polyphenol with various biological effects such as anti-inflammatory, anti-oxidant, anti-mutagenic, anti-carcinogenic, and cardioprotective properties. As part of the overall safety assessment of HS-1793, a novel resveratrol analogue free from the restriction of metabolic instability and the high dose requirement of resveratrol, we assessed genotoxicity in three in vitro assays: a bacterial mutation assay, a comet assay, and a chromosomal aberration assay. In the bacterial reverse mutation assay, HS-1793 did not increase revertant colony numbers in S. typhimurium strains (TA98, TA100, TA1535 and TA1537) or an E. coli strain (WP2 uvrA) regardless of metabolic activation. HS-1793 showed no evidence of genotoxic activity such as DNA damage on L5178Y $Tk^{+/-}$ mouse lymphoma cells with or without the S9 mix in the in vitro comet assay. No statistically significant differences in the incidence of chromosomal aberrations following HS-1793 treatment was observed on Chinese hamster lung cells exposed with or without the S9 mix. These results provide additional evidence that HS-1793 is non-genotoxic at the dose tested in three standard tests and further supports the generally recognized as safe determination of HS-1793 during early drug development.

Analysis of Radioactivity Concentrations in Cigarette Smoke and Tobacco Risk Assessment (담배연기와 담뱃잎 내 함유된 방사능 농도분석 및 위해도 평가)

  • Lee, Se-Ryeong;Lee, Sang-Bok;Kim, Jeong-Yoon;Kim, Ji-Min;Bang, Yei-jin;Lee, Doo-Seok;Jo, Hyung-Joon;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.489-494
    • /
    • 2021
  • In this study, radioactivity quantitative analysis was performed on radon contained in cigarette, and the effective dose was calculated using the result value to determine the amount of exposure caused by smoking. A total of 5 types of cigarettes were sampled. Cigarette smoke was collected by using activated carbon, and tobacco were measured by homogenizing for quantitative analysis. For each sample, Bi-214 and Pb-214 were subjected to gamma nuclide analysis to observe the uranium-based radioactive material contained in cigarette, and a measurement time of 30,000 seconds was set for the sample based on the results of previous studies. As a result of measuring the radioactivity of tobacco, a maximum of 0.715 Bq/kg was derived, and in the case of cigarette smoke measured using activated carbon, a maximum of 3.652 Bq/kg was derived. Using this measurement, the average effective dose to the lungs is 0.938 mSv/y, and it was found that there is a possibility of receiving exposure up to 1.099 mSv/y depending on the type of tobacco. It was found that the exposure dose due to cigarette occupies a large proportion of the annual effective dose limit for the general public. Therefore, more diverse studies on radioactive substances in cigarette are needed, and measures to monitor and reduce the incidental exposure to radon should be established.

Doses of Pediatric and X-ray Examination Assistants according to Changes in Pediatric X-ray Exposure Conditions (소아 X선 촬영조건 변화에 따른 소아 및 촬영보조자 선량)

  • Beom-Jin Jang;Ha-Yun Nam;Hye-Min Shin;Dong-Min Yun;Seung-Kook Lee;In-Hwa Jang;Sungchul Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.409-415
    • /
    • 2023
  • Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ~ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.

Optimization of Non-Local Means Algorithm in Low-Dose Computed Tomographic Image Based on Noise Level and Similarity Evaluations (노이즈 레벨 및 유사도 평가 기반 저선량 조건의 전산화 단층 검사 영상에서의 비지역적 평균 알고리즘의 최적화)

  • Ha-Seon Jeong;Ie-Jun Kim;Su-Bin Park;Suyeon Park;Yunji Oh;Woo-Seok Lee;Kang-Hyeon Seo;Youngjin Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.39-48
    • /
    • 2024
  • In this study, we optimized the FNLM algorithm through a simulation study and applied it to a phantom scanned by low-dose CT to evaluate whether the FNLM algorithm can be used to obtain improved image quality images. We optimized the FNLM algorithm with MASH phantom and FASH phantom, which the algorithm was applied with MATLAB, increasing the smoothing factor from 0.01 to 0.05 with increments of 0.001 and measuring COV, RMSE, and PSNR values of the phantoms. For both phantom, COV and RMSE decreased, and PSNR increased as the smoothing factor increased. Based on the above results, we optimized a smoothing factor value of 0.043 for the FNLM algorithm. Then we applied the optimized FNLM algorithm to low dose lung CT and lung CT under normal conditions. In both images, the COV decreased by 55.33 times and 5.08 times respectively, and we confirmed that the quality of the image of low dose CT applying the optimized FNLM algorithm was 5.08 times better than the image of lung CT under normal conditions. In conclusion, we found that the smoothing factor of 0.043 among the factors of the FNLM algorithm showed the best results and validated the performance by reducing the noise in the low-quality CT images due to low dose with the optimized FNLM algorithm.

Multifocal nodular lymphoid hyperplasia of the lung

  • Lee, Gil Tae;Kim, Eun Kyoung;Cho, Eirie;Lee, Seung-Sook;Kim, Seo Yun;Kim, Cheol Hyeon;Kim, Hye-Ryoun
    • Journal of Yeungnam Medical Science
    • /
    • v.34 no.1
    • /
    • pp.84-87
    • /
    • 2017
  • Nodular lymphoid hyperplasia (NLH) is a benign lymphoproliferative disease that can affect the lung. Because of its rarity, little is known about the etiology and natural history of NLH. Most cases are usually asymptomatic and found incidentally on imaging studies. Imaging finding of NLH has shown most commonly as a solitary lesion, although multifocal pulmonary nodules may be seen. Surgical resection has proved curative in the cases previously described. We report a rare case of NLH in a 55 year-old man who presented with bilateral multiple pulmonary nodules on chest radiography. Open biopsy was performed from the upper and lower lobe of the left lung. The lesions were pathologically diagnosed as pulmonary NLH. Multifocal residual nodules in both lungs remain stable without spontaneous regression during the 3 years of follow-up.

Study Radiological Defense Interrelationship Research in Career (경력에 따른 방사선방어 상관성 연구)

  • Kim, Jean Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.135-138
    • /
    • 2012
  • Purpose : This research the isotope of handling was to an actual act of the radiological defense which it follows in career of the clinical pathological companies in order to inquire the interrelation for a radiological defense. Materials and Methods : The tool of this research with question from 2010 October until November did electrification Chwung Cheng and the Seoul isotope thread clinical pathological company with the object person and it investigated in direct question or mail method, the data which is collected used SPSS19.0 programs and frequency and percentage and t-test, ANOVA, it used it analyzed a multiple regression analysis method. Results : The interrelationship of the radiological defense which it follows in career was visible the interrelation which considers statistically (p<0.01). But the correlation coefficient appeared lowly with 0.196. With the variable who affects in radiological defense act it appeared with worker providing by law educations and RI license acquisitions. Conclusion : There is to business progress and the radiological defense act respects a worker safety stands the unit only is the fact which is important. Consequently a possibility of saying that the radiation worker education is necessary, it executes the education which is continuous, RI license acquisitions, there is.

  • PDF

Comparison of Factors Affecting Job Stress and Satisfaction of Medical Technician : Focus on Incheon Area (의료기사의 직무스트레스와 만족도의 영향요인 비교 : 인천지역을 중심으로)

  • Lee, Eun_Mo;Ahn, Sung_Min
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.627-635
    • /
    • 2018
  • The purpose of this study was to compare the job stress, job satisfaction, turnover intention, and job performance feelings of radiological technologists, physical therapists, and medical laboratory technologists working at university hospitals and general hospitals. The subjects were 114 general practitioners and 217 university hospital workers who are engaged in occupations of radiological technologists, physical therapists, and medical laboratory technologists in the age groups 20-50 years living in Incheon Metropolitan City. Data collection was conducted from April 1, 2017 to April 30, and data analysis was performed using the SPSS/WIN 23 statistical program. There were statistically significant difference in the job stress of medical technician by age, marriage, occupation, hospital size, position, parenting form, employment type, and lunch break. Job stress by occupation was highest in medical laboratory technologists, followed by radiological technologists and physical therapists. Job satisfaction was the highest among physical therapists. followed by radiological technologists and medical laboratory technologists. There were significant differences in age, occupation, parenting form, type of employment, and lunch break according to demographic characteristics. In order to reduce the job stress and job satisfaction of the medical technician working at the hospital, the development of the job environment should be sought and the hospital should also be removed from the authoritarian management system.

Real-time monitoring of ultra-high dose rate electron beams using bremsstrahlung photons

  • Hyun Kim;Dong Hyeok Jeong;Sang Koo Kang;Manwoo Lee;Heuijin Lim;Sang Jin Lee;Kyoung Won Jang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3417-3422
    • /
    • 2023
  • Recently, as the clinically positive biological effects of ultra-high dose rate (UHDR) radiation beams have been revealed, interest in flash radiation therapy has increased. Generally, FLASH preclinical experiments are performed using UHDR electron beams generated by linear accelerators. Real-time monitoring of UHDR beams is required to deliver the correct dose to a sample. However, it is difficult to use typical transmission-type ionization chambers for primary beam monitoring because there is no suitable electrometer capable of reading high pulsed currents, and collection efficiency is drastically reduced in pulsed radiation beams with ultra-high doses. In this study, a monitoring method using bremsstrahlung photons generated by irradiation devices and a water phantom was proposed. Charges collected in an ionization chamber located at the back of a water phantom were analyzed using the bremsstrahlung tail on electron depth dose curves obtained using radiochromic films. The dose conversion factor for converting a monitored charge into a delivered dose was determined analytically for the Advanced Markus® chamber and compared with experimentally determined values. It is anticipated that the method proposed in this study can be useful for monitoring sample doses in UHDR electron beam irradiation.