• Title/Summary/Keyword: Radiologic technologist

Search Result 53, Processing Time 0.024 seconds

Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography (복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향)

  • Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

Analyzing the Levels of Vocational key competencies Required by Radiological Technologist Job Description in Blind Hiring process (블라인드 채용 시 방사선사 직무기술서에서 요구하는 직업기초능력 수준 분석)

  • Jang, Hyon Chol;Lee, Myung Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.103-110
    • /
    • 2019
  • The objective of this study was to prepare the baseline data for vocational key competence of radiologists by analyzing the communication skills, problem-solving skills, self-development capability, interpersonal skills, and vocational ethics, which are required by NCS job descriptions for radiologists, of college students majoring in radiology. This study surveyed 79 sophomore and junior college students majoring in radiology at S University from Nov 19 to Nov 30, 2018, using questionnaires and analyzed the levels of vocational key competencies. The analysis results of vocational key competences levels showed that the level of interpersonal skills was the highest (71.2 points for juniors and 74.9 points for seniors). The levels of problem-solving skills and self-development capability were low. Conflict management capability, which is a sub-domain of interpersonal skills, was 77.5 and 80.5 points for juniors and seniors, respectively, which were the highest, while leadership ability was the lowest. When the sub-domains of self-development capability were analyzed, self-recognition capability was the highest (70.0 points for juniors and 74.8 points for seniors) and the career development capability was the lowest. Colleges are required to develop a customized regular curriculum that is well-linked to the clinic in order to improve the vocational key competencies required by the NCS job description to prepare for the blind hiring process. Colleges also put efforts to educate radiologists who can actively cope with rapidly changing medical environment by running various non-regular programs.

Cause and Solution of an Artifact Generation by Parameter in Computed Radiography System (Computed Radiography 영상에서 Parameter에 의한 Artifact 원인과 해결방안)

  • Dong, Kyung-Rae;Choi, Jun-Gu;Hong, Seong-Il
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.5
    • /
    • pp.145-155
    • /
    • 2009
  • There is a great deal of merit in CR system but artifact not produced in old system of film or screen newly is created. we studied 3 cases of artifact with CR system in one hospital, Gwangju. In the first case of the delay time and density, As the time was delayed, the density of the artifact was increased up to 67 percent in the natural radiation. The Second, Fading of the artifact decreased 33 percent in the rate of the emission after 10 hours, and the more the time was delayed, the less the quality of image was deteriorated. Third, Artifact was produced by the collimation when the radiologic technologist was performed, and by the Guiding plate and Suction cup when the radiation equipment was done. Therefore, when health care provider have to understand the artifact exactly and check regularly, the quality of the picture and the satisfaction of the medical examination is increased.

The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC (자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향)

  • Yoon, Seok-Hwan;Choi, Jun-Gu;Han, Dong-Kyoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

Reduction of the Useless Radiation Exposure to Patients and Improvement of the Skill to Manage the Test according to Minimizing Changes of Posture in Bone Mineral Density (골밀도 검사에서 환자 자세 변경 최소화에 따른 수검자의 불필요한 피폭선량 감소 및 생산성 향상)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Kim, Chang-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.228-235
    • /
    • 2009
  • As we recognize the health care, test of BMD is increased. There are various methods in BMD, Dual Energy X-ray absorptiometry (DEXA) which has high precision and accuracy, and low medical exposure dose has been widely used. To measure the changes of BMD, the test must be done as same posture at first and follow up study performed a year. we analyze the difference in the hour taken before and after the examination by radiologic technologist, frequency of scout scan, and the amount of the radiation exposure. The hour of the examination and frequency of the scout scan were shorten and the dose of the radiation exposure is reduced. As the numerical value of total subjects is converted into that of one person, the duration for the test was 52 seconds, the frequency for the scout scan 0.79 time, and the dose for the radiation exposure $13{\mu}Sv$. When the health care provider perform the precise and easy methods to minimize changes of posture and the skillful ability to manage the test, useless radiation is decreased.

Development and Application of Case-Based Learning Program for Occupational Personality Education of Health Care Worker (보건의료종사자 맞춤형 직업인성교육을 위한 사례기반학습 프로그램 개발 및 적용)

  • Yang, Eun Ju;Kim, Hye Ran;Chang, Jeong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.371-379
    • /
    • 2021
  • The personality education of the existing university is mainly focused on occupational ethics education or basic education, but the purpose and method of the personality education program is changed in preparation for the 4th industry and the related occupational personality education program is needed. In Korea, however, there is a lack of research on the development of educational programs for occupational personalities that Health care workers should have. Therefore, this study aims to confirm the effect by developing and applying a program for occupational personality education for Health care workers required for the 4th Industrial Revolution based on case-based learning. In this study, general cases and occupational cases were developed, and research tools were developed to verify the effectiveness of the occupational personality education program. The program developed in this study was provided four times for 52 students in the second and third grades college and university. This study was performed with a single group pre-post design. The data were analyzed by means of mean, standard deviation, and paired t-test. By applying the program developed in this study, accountability, honesty, consideration, collaboration, communication, and competency were improved. This confirmed the positive effect of vocational character education

The Utility of Chatbot for Learning in the Field of Radiology (방사선(학)과 분야에서 챗봇을 이용한 학습방법의 유용성)

  • Yoon-Seo Park;Yong-Ki Lee;Sung-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.411-416
    • /
    • 2023
  • The purpose of this study is to investigate the utilization of major learning tools among radiology science students and assess the accuracy of a conversational artificial intelligence service program, specifically a chatbot, in the context of the national radiologic technologist licensing exam. The survey revealed that 84.3% of radiology science students actively utilize electronic devices during their learning process. In addition, 104 out of 140 respondents said they use search engines as a top priority for efficient data collection while studying. When asked about their awareness of chatbots, 80% of participants responded affirmatively, and 22.9% reported having used chatbots for academic purposes at least once. From 2018 to 2022, exam questions from the first and second periods were presented to the chatbot for answers. The results showed that ChatGPT's accuracy in answering first period questions increased from 48.28% to 60%, while for second period questions, it increased from 50% to 62.22%. Bing's accuracy in answering first period questions improved from 55% to 64.55%, and for second period questions, it increased from 48% to 52.22%. The study confirmed the general trend of radiology science students utilizing electronic devices for learning and obtaining information through the internet. However, conversational artificial intelligence service programs in the field of radiation science face challenges related to accuracy and reliability, and providing perfect solutions remains difficult, highlighting the need for continuous development and improvement.

Evaluation of Usefulness of Assertive Devices to Improve the Accuracy in Skull lateral X-ray Projection (두개골 측방향 X-선 촬영에서 정확도 향상을 위한 촬영 보조 기구의 유용성 평가)

  • Bo-Seok Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.153-159
    • /
    • 2024
  • In X-ray projection, Unskilled radiologists become skilled through fail exam. This causes the patient to be exposed to unnecessary radiation. In this study, pre-position unskilled radiologic technologist presented ways to improve clinical proficiency. presented a skull lateral x-ray projection practice method using visual, spatial, and assistive devices. In addition, the accuracy and usefulness of the use of assistive devices were evaluated. When X-ray images were taken based on learning, the rotational spacing, which indicates image distortion, was 7.85 ± 1.45 mm and the tiliting spacing was 4.84 ± 0.5 mm. When practicing using visual aids, the rotational spacing is 4.4 ± 0.76 mm and the inclination spacing is 3.01 ± 0.87 mm. using a spatial compensation device, the rotational spacing is 5.2 ± 0.69 mm and the tiliting spacing is 3.33 ± 0.61 mm. Skull lateral X-ray Image distortion caused by empirical photography practice decreased by 5.4%, but image distortion caused by tilting increased by 1.2%. When practicing using a visual assistive devices, the degree of rotational spacing by 40.1% and the tiliting spacing decreased by 30.7% compared to the empirical x-ray exposure practice. When using spatial assistive devices, the rotation interval was reduced by 41.7% and the tilting interval by 23.7% compared to conventional empirical x-ray exposure practice. Therefore, if an unskilled radiologist practices using visual and spatial aids,the accuracy will be improved in skull lateral x-ray projection.

Survery on Business of the Departments of Radiology in Health Centers (보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Huh, Joon;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

Analysis of Influencing Factors Related to Health Promotion Behavior in Hospital Radiological Technologists (종합병원 방사선사의 건강증진행위 관련요인 분석)

  • Ko, Jong-Kyung;Kwon, Duk-Mun;Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.381-391
    • /
    • 2009
  • Purposes : The purpose of this study was to analyze factors that could affect health of radiological technologists, which is useful for health care and development of programs for health promotion. Methods : Subjects were 234 of radiological technologists who work in general hospitals. Some questionnaires were made about perceptions of health condition and promotional behavior of health for this study. The questionnaires of health perception were 20 items that consist of the present condition of health, health concern and sensitivity. The reliability was sufficient(Cronbach's $\alpha=0.79$). The other questionnaires about health promotion behavior were 47 items that consist of self-realization, health responsibility, exercise, nutrition, personal relationships, and stress management. The results turned out to bewas sufficient (Cronbach's $\alpha=0.93$). Every data was treated statistically, comparison of average(t-test, ANOVA), correlation, and multiple regression. Results : Related factors to health promotion behavior were age, marriage, salary, class of one's position, career, employment, and religion, in general features. In health life habit, related factors were smoke and exercise. Results of health promotion behavior was 2.90 of mean score, 0.37 of standard deviation. Correlations between factors of health perception and health promotion behavior was positive(p<0.01). Health promotion behavior were affected by sensitivity, presents condition of health, exercise, smoke, career. Sensitivity was the most affectable variable, which means that promotional behavior score became higher and higher as the score of sensitivity and present condition were increased. In addition, persons who exercise regularly, had been smoked, and has higher career showed higher score of promotional behavior. Conclusion : Radiological technologists have to keep their health, trying not to infected by a disease. Most of all, no smoking and regular exercise are the most important thing to all of members.

  • PDF