• Title/Summary/Keyword: Radiologic imaging

Search Result 366, Processing Time 0.03 seconds

Radiologic Determination of Corpus Callosum Injury in Patients with Mild Traumatic Brain Injury and Associated Clinical Characteristics

  • Kim, Dong Shin;Choi, Hyuk Jai;Yang, Jin Seo;Cho, Yong Jun;Kang, Suk Hyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.2
    • /
    • pp.131-136
    • /
    • 2015
  • Objective : To investigate the incidence of corpus callosum injury (CCI) in patients with mild traumatic brain injury (TBI) using brain MRI. We also performed a review of the clinical characteristics associated with this injury. Methods : A total of 356 patients in the study were diagnosed with TBI, with 94 patients classified as having mild TBI. We included patients with mild TBI for further evaluation if they had normal findings via brain computed tomography (CT) scans and also underwent brain MRI in the acute phase following trauma. As assessed by brain MRI, CCI was defined as a high-signal lesion in T2 sagittal images and a corresponding low-signal lesion as determined by axial gradient echo (GRE) imaging. Based on these criteria, we divided patients into two groups for further analysis : Group I (TBI patients with CCI) and Group II (TBI patients without CCI). Results : A total of 56 patients were enrolled in this study (including 16 patients in Group I and 40 patients in Group II). Analysis of clinical symptoms revealed a significant difference in headache severity between groups. Over 50% of patients in Group I experienced prolonged neurological symptoms including dizziness and gait disturbance and were more common in Group I than Group II (dizziness : 37 and 12% in Groups I and II, respectively; gait disturbance : 12 and 0% in Groups I and II, respectively). Conclusion : The incidence of CCI in patients with mild TBI was approximately 29%. We suggest that brain MRI is a useful method to reveal the cause of persistent symptoms and predict clinical prognosis.

CD Copy Service to Enhance Customer Satisfaction Through Improved Flow Study - Based on QI Use - (CD Copy업무 flow개선을 통한 고객만족도 향상에 관한 연구 - QI 활용을 중심으로 -)

  • Choi, Sung-Hyun;Hwang, Sun-Kwang;Lee, Jong-Woong;Dong, Kyung-Rae;Kweon, Dae-Cheol;Goo, Eun-Hoe;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.127-132
    • /
    • 2011
  • This is to improve the complicate process of the existing CD copy flow in Department of Radiology. It is also to improve the medical service of the hospital to secure private information of patients. Survey: The patients who ask for CD copies in the Department of Radiology of this hospital(for 6 months in 2010). Time: Comparing the total amount of time of the previous and the modified CD copy flow. Using the SPSS 12.0 program for testing significance of independent two-samples t-test. Private information: Introducing the identification-system based on the medical law to supplement the security of personal information of patients. There was manifold complaints due to receipt and issuing the prescription in Admission and Discharging office and outpatient department. The time has been approximately 50% reduced from 70 mistunes to 32 mistunes due to simplifying the routes. The security of the personal information has been supplemented by let patients submit documentary evidence based on the medical law. The service in the hospital has been improved as a result of simplifying the whole process of the routes and receipt process. Therefore, the each stage of waiting time has been decreased. In addition, the personal information of the patients has been more secured.

  • PDF

Glomus Tumor of the Hand

  • Lee, Won;Kwon, Soon Beom;Cho, Sang Hun;Eo, Su Rak;Kwon, Chan
    • Archives of Plastic Surgery
    • /
    • v.42 no.3
    • /
    • pp.295-301
    • /
    • 2015
  • Background Glomus tumors were first described by Wood in 1812 as painful subcutaneous tubercles. It is an uncommon benign neoplasm involving the glomus body, an apparatus that involves in thermoregulation of cutaneous microvasculature. Glomus tumor constitutes 1%-5% of all hand tumors. It usually occurs at the subungual region and more commonly in aged women. Its classical clinical triad consists of pain, tenderness and temperature intolerance, especially cold sensitivity. This study reviews 15 cases of glomus tumor which were analyzed according to its anatomic location, surgical approach and histologic findings. Methods Fifteen patients with subungual glomus tumors of the hand operated on between January 2006 and March 2013, were retrospectively reviewed. Patients were evaluated preoperatively with standard physical examination including ice cube test and Love's test. Diagnostic imaging consisted of ultrasonography, computed tomography, and magnetic resonance imaging. All procedures were performed with tourniquet control under local anesthesia. Eleven patients underwent excision using the transungual approach, 3 patients using the volar approach and 1 patient using the lateral subperiosteal approach. Results Total of 15 cases were reviewed. 11 tumors were located in the nail bed, 3 in the volar pulp and 1 in the radial aspect of the finger tip. After complete excision, patients remained asymptomatic in the immediate postoperative period. In the long term follow up, patients exhibited excellent cosmetic results with no recurrence. Conclusions Accurate diagnosis should be made by physical, radiologic and pathologic examinations. Preoperative localization and complete extirpation is essential in preventing recurrence and subsequent nail deformity.

Mandibular Reconstruction and Dental Implantation after Segmental Mandibulectomy of Ameloblastoma of the Mandible (하악골 법랑질모세포종의 분절 하악절제술 후 하악 재건 및 치아 임플란트 시술)

  • Seo, Seung-Jo;Lee, Il-Jae;Lee, Jung-Geun;Lim, Hyo-Seob;Kim, Chee-Sun;Park, Myong-Chul
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.212-216
    • /
    • 2011
  • Purpose: Ameloblastomas are rare benign tumors of odontogenic origin, and compose about 1% of all oral and maxillomandibular cysts and tumors. Because this neoplasm has a high rate of local recurrence, segmental mandibulectomy with a 1~2 cm safety margin and immediate microsurgical reconstruction is an accepted treatment modality. The authors experienced four mandibular reconstruction cases that underwent secondary dental implantation. Here, the authors describe these cases and their long-term results. Methods: Four patients with ameloblastoma of the mandible underwent segmental mandibulectomy and reconstruction with a free fibula osseous flap from January 1999 to May 2005, followed by secondary dental implantation. Recurrence, bony union, implant osseointegration, and functional and aesthetic results were evaluated by radiologic imaging, by physical examination, and by using photographs. Results: All free flaps survived with no evidence of flap loss. To date, no recurrence has been noted clinically or radiologically. Imaging after mandibular reconstruction with a free fibular flap revealed satisfactory bony unions and mandibular contours. The patients achieved good aesthetic and functional results after the secondary implantation. Conclusion: Mandibular reconstruction using a fibular osseous flap and secondary dental implantation can produce good functional and aesthetic results after segmental mandibulectomy for ameloblastoma.

Effects of Contrast Agent Concentration on the Signal Intensity and Turbo Factor of TSE and Slice-selective IR in T1-weighted Contrast Imaging

  • Han, Yong Soo;Lee, Soo Chul;Lee, Dong Yong;Choi, Jiwon;Lee, Jong Woong;Kweon, Dae Cheol
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.115-124
    • /
    • 2016
  • The present study analyzes T1 TSE and T1 slice sel. IR (dark_fluid) signal strength according to the degree of gadolinium contrast agent dilution and analyzes the turbo factors with regard to changes in the maximum and overall signal strength to study correlations between changes and signal-to-noise ratios (SNRs) and compare peak-to-peak SNR (PSNR) enhancement in order to improve the quality of T1-weighted images. Enhancement TR (600 msec) evaluated to determine the T1 TSE turbo factor and obtain the maximum signal strength, T1WI were used sequentially to experiment with turbo factors_1-4. T1 slice sel. IR (dark-fluid) was used to sequentially test turbo factors_2-5 but not turbo factor_1 at a TR (1500 msec) and compare data at an increase in T1 of 900 msec. The T1 TSE was reduced according to the contrast agent concentration. Phantom signal strength increased, whereas turbo factors_1-4 exhibited maximum signal strength at a concentration of 3 mmol, followed by a gradual decrease. In the turbo factors_2-5, the signal strength increased sharply to maximum signal strength at 0.7 mmol, followed by a reduction. T1 TSE had a greater maximum signal strength than did T1 slice sel. IR (dark_fluid). A comparison of SNR found that T1 TSE imaging was superior (33.3 dB) in turbo factor_1 and T1 slice sel. IR (dark_fluid) was highest (33.9 dB) at turbo factor_5. A PSNR comparison analysis was not sufficient to distinguish between the images obtained with both techniques at 30 dB or higher under all experimental conditions.

The Research for Scannogram (Scannogram, Whole Spine image 획득에 관한 연구)

  • Lee, Gwnag-Jae;Go, Shin-Guan;Kim, Uk-Dong;Kim, Shi-Don;Kim, Hyung-Seop
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • I.objective The composition method with acquiring 2${\sim}$5 image not only lack perfection in compensating the geometrical distortion but could also cause inaccurate connection problem of compensating the geometrical distortion but could also cause inaccurate connection problem of continuing bone structure due to the enlargement ratio difference of ruller and bone, density difference in image composition process. This paper studies those mentioned problems through the experiments. II. Object and method Experiment 1 After attaching 3 step wedge(Pb) on detector and 2 ruller on upper, lower part of the step wedge, we have exposed them to create density difference between 1st image and 2nd image, then examined if there were any errors. Experiment 2 1st 100cm ruller was attached on the center of detector, and by escalating the distance between 2nd 100cm ruller and detector 5cm, 10cm, 15cm respectively, we investigated if there any errors caused by enlargement ratio. Experiment 3 The ruller was placed on detector, a joint photographing was performed through spot photographing after fully operating the electric field photographing to include hip joint ${\sim}$ ankle joint part and we have compared the values from two methods. III. Result : A horizontal axis error was caused when photopraphing is not poerated in equal density since the image shifted horizontally in accordance with the difference of Pb step wedge 1 due to the density difference, as the result of Epperiment 1.

  • PDF

The Study of Difference on Each System for Reliance Security in SUV of PET/CT Images : Initial Study (PET/CT 영상에서의 표준섭취계수(SUV)의 신뢰성 확보를 위한 시스템별 차이에 관한 연구 : 초기 연구)

  • Park, Hoon-Hee;Park, Min-Soo;Kim, Jung-Yul;Lee, Seung-Jae;Sheen, Hee-Soon;Lim, Han-Sang;Kim, Sei-Young;Jang, Hye-Won;Oh, Ki-Back;Kim, Jae-Sam;Lee, Chang-Ho
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.5-6
    • /
    • 2008
  • In this study, using an experiment, in certified an error between each system of SUV (standardized uptake value) that is one of the main analyses to diagnose a tumor in PET/CT, so, it would assure reliability and help to diagnose any lesions accurately. That is, a detailed analysis progressed. as all images reconstructed every setting time, then, clinical reliability between each system was expressed numerically at MBq/mL and SUV. Therefore, this study is considered that flexibility of follow-up using diverse system was insured, and it helps to offer accurate and beneficial information for diagnosis of various fields.

  • PDF

Comparison of the Quality of Clavicle Fracture Three-dimensional Model Printing by Open Source and Commercial use Digital Imaging and Communications in Medicine Stereolithography File Conversion Program (공개용과 상업용 DICOM STL 파일변환 프로그램으로 출력한 삼차원 프린팅 쇄골 골절 모델의 품질비교)

  • Oh, Wang-Kyun;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.61-66
    • /
    • 2018
  • The recent 3D printing technology is used in various medical, manufacturing, and education fields and is more efficient in terms of production process, time, and cost than existing production. Especially in fracture surgery, interest and research have been focused on improving accuracy, shortening of operation time and recovery time, and reducing reoperation. However, because of the financial and technical problems of the 3D printer and the file conversion program, the 3D printing is made directly at the hospital, and it is not generally used for diagnosis of fracture and surgical research. In this study, to solve those problems, clavicle CT imaging was switched into Osirix Open Source DICOM Viewer, Stereolithography file conversion programs and commercial Terarecon 3D DICOM Viewer, file conversion programs, and then clavicle fracture model was directly made through 3D printer of fused filament fabrication wire additive processing method, and then the accuracy of the shape was compared and analyzed. Clavicle fracture models printed in two methods were blind-tested on clinicians of general hospitals' orthopedics and radiologic technicians with over 10 years of experiences, and then their analysis opinions of resolution reviews were analyzed. The result showed no difference. The 3D printing model with open source DICOM STL file conversion program used was applicable to clinical, so it is considered useful in precision diagnosis of fracture and operation plans.

A Case of Intradural-Extramedullary Form of Primary Spinal Cysticercosis Misdiagnosed as an Arachnoid Cyst

  • Yoo, Minwook;Lee, Chang-Hyun;Kim, Ki-Jeong;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.4
    • /
    • pp.226-229
    • /
    • 2014
  • We describe a rare case of intradural-extramedullary primary spinal cysticercosis. A 42-year-old man visited our institute for lower back pain. He denied having consumed raw meet. Magnetic resonance (MR) images revealed an intradural pure cystic mass at the L3-L4 level. A radiologic diagnosis of spinal arachnoid cyst was established. Three years later, he complained of aggravated back pain, and follow-up MR examination showed a markedly expanded cyst, occupying the subarachnoid space from the T11 to the S1 level. L2 hemilaminectomy was performed, and a yellowish infected cyst bulged out through the dural opening. The cyst was removed en bloc. The histopathological findings of the cyst were consistent with parasitic infection. Serum enzyme-linked immunosorbent assay (ELISA) confirmed the presence of spinal cysticercosis. As there was no intracranial lesion, the final diagnosis was primary spinal cysticercosis, which is very rare. MR imaging is a sensitive diagnostic tool for detecting cystic lesions in the spine; however, it is difficult to distinguish cysticercosis from non-infectious cysts such as an arachnoid cyst without using gadolinium enhancement. Clinicians treating spinal cysts with an unusual clinical course should include cysticercosis as a differential diagnosis. We recommend contrast-enhanced MR imaging and serum ELISA in the diagnostic work-up of such cases.

Radiation measurement and imaging using 3D position sensitive pixelated CZT detector

  • Kim, Younghak;Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1417-1427
    • /
    • 2019
  • In this study, we evaluated the performance of a commercial pixelated cadmium zinc telluride (CZT) detector for spectroscopy and identified its feasibility as a Compton camera for radiation monitoring in a nuclear power plant. The detection system consisted of a $20mm{\times}20mm{\times}5mm$ CZT crystal with $8{\times}8$ pixelated anodes and a common cathode, in addition to an application specific integrated circuit. The performance of the various radioisotopes $^{57}Co$, $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ was evaluated. In general, the amplitude of the induced signal in a CZT crystal depends on the interaction position and material non-uniformity. To minimize this dependency, a drift time correction was applied. The depth of each interaction was calculated by the drift time and the positional dependency of the signal amplitude was corrected based on the depth information. After the correction, the Compton regions of each spectrum were reduced, and energy resolutions of 122 keV, 356 keV, 511 keV, and 662 keV peaks were improved from 13.59%, 9.56%, 6.08%, and 5%-4.61%, 2.94%, 2.08%, and 2.2%, respectively. For the Compton imaging, simulations and experiments using one $^{137}Cs$ source with various angular positions and two $^{137}Cs$ sources were performed. Individual and multiple sources of $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ were also measured. The images were successfully reconstructed by weighted list-mode maximum likelihood expectation maximization method. The angular resolutions and intrinsic efficiency of the $^{137}Cs$ experiments were approximately $7^{\circ}-9^{\circ}$ and $5{\times}10^{-4}-7{\times}10^{-4}$, respectively. The distortions of the source distribution were proportional to the offset angle.